Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ampere”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Some experience with arc-heater simulation of outer planet entry radiation

An electric arc heater was operated at 800 amperes and 100,000 pa (1 atm) with hydrogen, helium, and two mixtures of hydrogen and helium. A VUV-scanning monochromator was used to record the spectra from an end view while a second spectrometer was used to determine the plasma temperature using hydrogen continuum radiation at 562 nm. Except for pure helium, the plasma temperature was found to be too low to produce significant helium radiation, and the measured spectra were primarily the hydrogen spectra with the highest intensity in the pure hydrogen case. A radiation computer code was used to compute the spectra for comparison to the measurements and to extend the study to simulation of outer planet entry radiation. Conductive cooling prevented ablation of phenolic carbon material samples mounted inside the arc heater during a cursory attempt to produce radiation absorption by ablation gases.

Wells, W. L.↗

Discussion of the SAGE anomaly

The performance of a nine-ampere-hour, nickel cadmium cell operating in a satellite power system is examined. Data for battery average dissipation, voltage profiles, battery temperatures, and the percent of recharge versus orbit are presented. The occurence of undervoltage and increased recharge/orbit percentages are examined and suggestions are made as to their causes.

Baer, D.↗

NASA 50 amp hour nickel cadmium battery waste heat determination

A process for determining the waste heat generated in a 50-ampere-hour, nickel cadmium battery as a function of the discharge rate is described and results are discussed. The technique involved is essentially calibration of the battery as a heat transfer rate calorimeter. The tests are run at three different levels of battery activity, one at 40-watts of waste heat generated, one at 60, and one at 100. Battery inefficiency ranges from 14 to 18 percent at discharge rates of 284 to 588 watts, respectively and top-of-cell temperatures of 20 C.

Mueller, V. C.↗

The LDEF heat pipe experiment power systems

A heatpipe experiment for a long duration exposure facility is described. The design and configuration of the power system of the spacecraft is reported with emphasis placed on its solar array panels, 12-ampere hour 18-cell nickel battery, and its electronic controller.

Tiller, S. E.↗

Nickel hydrogen cell characterization test results

Charge control studies on nickel hydrogen cells are discussed. Characterization test data for the cells are presented in graphical form. The test areas covered were capacity versus temperature, ampere-hour cycling efficiency, and the charge method which involved voltage level with current limiting.

Otzinger, B.↗

F-5F Shark Nose radome lightning test

A unique F-5F radome wtih a geometry similar to a Shark Nose profile was tested with a high voltage Marx generator, 1,200,000 volts in order to demonstrate the effectiveness of the lightning protection system with currents from 5,000 amperes or greater. An edge discontinuity configuration is a characteristic feature in the forward region of the radome and occasionally serves as an attachment point. The results of nineteen attachment tests at various aspect angles with an air gap of one meter indicated that no damage occurred to the dielectric material of the radom. The test proved the effectiveness of the lightning protection system.

Scott, G. W.↗

Pulse charging of lead-acid traction cells

Pulse charging, as a method of rapidly and efficiently charging 300 amp-hour lead-acid traction cells for an electric vehicle application was investigated. A wide range of charge pulse current square waveforms were investigated and the results were compared to constant current charging at the time averaged pulse current values. Representative pulse current waveforms were: (1) positive waveform-peak charge pulse current of 300 amperes (amps), discharge pulse-current of zero amps, and a duty cycle of about 50%; (2) Romanov waveform-peak charge pulse current of 300 amps, peak discharge pulse current of 15 amps, and a duty of 50%; and (3) McCulloch waveform peak charge pulse current of 193 amps, peak discharge pulse current of about 575 amps, and a duty cycle of 94%. Experimental results indicate that on the basis of amp-hour efficiency, pulse charging offered no significant advantage as a method of rapidly charging 300 amp-hour lead-acid traction cells when compared to constant current charging at the time average pulse current value. There were, however, some disadvantages of pulse charging in particular a decrease in charge amp-hour and energy efficiencies and an increase in cell electrolyte temperature. The constant current charge method resulted in the best energy efficiency with no significant sacrifice of charge time or amp-hour output. Whether or not pulse charging offers an advantage over constant current charging with regard to the cell charge/discharge cycle life is unknown at this time.

Smithrick, J. J.↗

Pioneer Venus Orbiter Electron Temperature Probe

The Orbiter Electron Temperature Probe (OETP) instrumentation and measurement technique has been designed to perform in-situ measurements of electron temperature and electron and ion density in the ionosphere of Venus. Adaptive sweep voltage circuitry continuously tracks the changing electron temperature and spacecraft potential while auto-ranging electrometers adjust their gain in response to the changing plasma density. Control signals used in the instrument to achieve this automatic tracking provide a continuous monitor of the ionospheric parameters without telemetering each volt-ampere curve. Internal data storage permits high data rate sampling of selected raw characteristic curves for low rate transmission to earth. These curves are used to verify or correct the inflight processed data. Sample in orbit measurements are presented to demonstrate instrument performance.

Krehbiel, J. P.↗

Nickel-cadmium batteries for the Modular Power Subsystem

Nickel-cadmium batteries of 20 and 50 ampere-hour (AH) capacity have been developed and qualified. These batteries provide an energy storage capability of 40 to 150 AH for the Modular Power Subsystem, which is the power source for NASA's Multimission Modular Spacecraft. Battery fabrication is rigidly controlled to assure uniform performance from battery to battery. A unique feature of the battery design is that cells from various manufacturers can be used for battery assembly without modification. Both 20 and 50-AH batteries have been delivered, and an MPS module with three 20-AH batteries is currently operating satisfactorily in low earth orbit. Design characteristics and performance of the batteries are described.

Mueller, V. C.↗

Nickel-hydrogen battery integration study for the Multimission Modular Spacecraft

A study has been performed to determine the feasibility of using nickel-hydrogen batteries as replacements for the nickel-cadmium batteries currently used for energy storage in the Multimission Modular Spacecraft under a contract with NASA Goddard Space Flight Center. The battery configuration was selected such that it meets volumetric and mounting constraints of the existing battery location, interfaces electrically with existing power conditioning and distribution equipment, and maintains acceptable cell operating temperatures. The battery contains 21, 50 ampere-hour cells in a cast aluminum structural frame. Cells used in the battery design are those developed under the Air Force's Aero Propulsion Laboratory funding and direction. Modifications of the thermal control system were necessary to increase the average output power capability of the Modular Power Subsystem.

Mueller, V. C.↗

Vehicles testing of near-term batteries

Vehicles test results are reported for nickel-iron, nickel-zinc, and improved lead-acid batteries developed under the Near-Term Battery Program sponsored by the Department of Energy. The batteries have demonstrated a range improvement of up to 90% over current lead-acid batteries due to improved energy density and ampere-hour capacity, combined with relatively small weight and volume. However, the nickel-iron battery requires a substantial development effort in packaging the circulating electrolyte system and handling the generated hydrogen volume, while the nickel-zinc batteries tested suffer from short cycle life.

Conover, R. C.↗

JPL's electric and hybrid vehicles project: Project activities and preliminary test results

Efforts to achieve a 100 mile urban range, to reduce petroleum usage 40% to 70%, and to commercialize battery technology are discussed with emphasis on an all plastic body, four passenger car that is flywheel assisted and battery powered, and on an all metal body, four passenger car with front wheel drive and front motor. For the near term case, a parallel hybrid in which the electric motor and the internal combustion engine may directly power the drive wheels, is preferred to a series design. A five passenger car in which the electric motor and the gasoline engine both feed into the same transmission is discussed. Upgraded demonstration vehicles were tested using advanced lead acid, nickel zinc, nickel iron, and zinc chloride batteries to determine maximum acceleration, constant speed, and battery behavior. The near term batteries demonstrated significant improvement relative to current lead acid batteries. The increase in range was due to improved energy density, and ampere hour capacity, with relatively 1 small weight and volume differences.

Barber, T. A.↗

The characteristics and limitations of the MPS/MMS battery charging system

A series of tests was conducted on two 12 ampere hour nickel cadmium batteries under a simulated cycle regime using the multiple voltage versus temperature levels designed into the modular power system (MPS). These tests included: battery recharge as a function of voltage control level; temperature imbalance between two parallel batteries; a shorted or partially shorted cell in one of the two parallel batteries; impedance imbalance of one of the parallel battery circuits; and disabling and enabling one of the batteries from the bus at various charge and discharge states. The results demonstrate that the eight commandable voltage versus temperature levels designed into the MPS provide a very flexible system that not only can accommodate a wide range of normal power system operation, but also provides a high degree of flexibility in responding to abnormal operating conditions.

Ford, F. E.↗

Radiated and conducted EMI from a 30-cm ion thruster

In order to properly assess the interaction of a spacecraft with the EMI environment produced by an ion thruster, the EMI environment was characterized. Therefore, radiated and conducted emissions were measured from a 30-cm mercury ion thruster. The ion thruster beam current varied from zero to 2.0 amperes and the emissions were measured from 5 KHz to 200 MHz. Several different types of antennas were used to obtain the measurements. The various measurements that were made included: magnetic field due to neutralizer/beam current loop; radiated electric fields of thruster and plume; and conducted emissions on arc discharge, neutralizer keeper and magnetic baffle lines.

Whittlesey, A. C.↗

Acceptance tests and manufacturer relationships for 20 amphere-hour sealed nickel-cadmium cells using discharge parameters

One hundred and forty-six 20 ampere-hour sealed nickel cadmium cells from five manufacturers were detected using preliminary tests which do not require life testing and do not reduce the expected life of the cells. Differences between individual cells were also detected, using these tests, allowing a comparison of variability of cell construction by and between manufacturers.

Leibecki, H. F.↗

Performance of a magnetic multipole line-cusp argon ion thruster

A 17 cm diameter line cusp ion thruster was evaluated with inert gases which are candidate propellants for on orbit and orbit transfer propulsion functions for Large Space Systems. A semiempirical relationship was generated to predict thruster beam current in terms of plasma parameters which would allow initial thruster optimization without ion extraction and the associated large vacuum facilities. The sensitivity of performance to changes in discharge electrode configurations and magnetic circuit was evaluated and is presented. After final optimization a propellant utilization efficiency of 0.9 at a discharge chamber power expenditure of about 260 w per beam ampere was obtained. These performance parameters are the highest yet achieved with argon propellant.

Sovey, J. S.↗

Li/SO2 Cell lot to lot variations and some design comparisons

Data collected from an investigation of Li/SO2 cells are presented. Two different cell designs are discussed: the standard cell, which has very high Li/SO2 ratios (1.5 or 2:1); and the balanced design, where the Li/SO2 ratio is 0.9:1 on an ampere hour basis.

Walk, C. R.↗

The CMG Nickel Electrode

The development and design of the Controlled Microgeometry electrode are described. Advantages of the electrode over others in existance include a higher number of ampere hours per kilogram and the ability to make them over a wide range of thicknesses. The parameters that control the performance of the electrode can be individually controlled over a wide range. Therefore, the electrode may be designed to give the optimum performance for a given duty cycle.

Depaul, R. A.↗