Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Well Locations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Structural and biochemical characterization of the mitomycin C repair exonuclease MrfB

Mitomycin C (MMC) repair factor A (mrfA) and factor B (mrfB), encode a conserved helicase and exonuclease that repair DNA damage in the soil-dwelling bacterium Bacillus subtilis. Here we have focused on the characterization of MrfB, a DEDDh exonuclease in the DnaQ superfamily. We solved the structure of the exonuclease core of MrfB to a resolution of 2.1 Å, in what appears to be an inactive state. In this conformation, a predicted α-helix containing the catalytic DEDDh residue Asp172 adopts a random coil, which moves Asp172 away from the active site and results in the occupancy of only one of the two catalytic Mg 2+ ions. We propose that MrfB resides in this inactive state until it interacts with DNA to become activated. By comparing our structure to an AlphaFold prediction as well as other DnaQ-family structures, we located residues hypothesized to be important for exonuclease function. Using exonuclease assays we show that MrfB is a Mg 2+ -dependent 3'–5' DNA exonuclease. We show that Leu113 aids in coordinating the 3' end of the DNA substrate, and that a basic loop is important for substrate binding. This work provides insight into the function of a recently discovered bacterial exonuclease important for the repair of MMC-induced DNA adducts.

59 BASIC BIOLOGICAL SCIENCES↗

Likelihood-based interactive local docking into cryo-EM maps in ChimeraX

The interpretation of cryo-EM maps often includes the docking of known or predicted structures of the components, which is particularly useful when the map resolution is worse than 4 Å. Although it can be effective to search the entire map to find the best placement of a component, the process can be slow when the maps are large. However, frequently there is a well-founded hypothesis about where particular components are located. In such cases, a local search using a map subvolume will be much faster because the search volume is smaller, and more sensitive because optimizing the search volume for the rotation-search step enhances the signal to noise. A Fourier-space likelihood-based local search approach, based on the previously published em_placement software, has been implemented in the new emplace_local program. Tests confirm that the local search approach enhances the speed and sensitivity of the computations. An interactive graphical interface in the ChimeraX molecular-graphics program provides a convenient way to set up and evaluate docking calculations, particularly in defining the part of the map into which the components should be placed.

59 BASIC BIOLOGICAL SCIENCES↗

Analysis of the Value Proposition of High-Efficiency, Multijunction Solar Modules for Residential Rooftop Installations

Utilizing detailed bottom-up models, we analyze the potential markets for high-efficiency photovoltaic modules in the United States. We first estimate the fraction of area-constrained residential rooftops that could benefit from increasing the availability of high-efficiency systems. We then model the impact of efficiency on installed system costs in these area-constrained scenarios. Finally, we explore the value proposition of high-efficiency, fixed-tilt micro-concentrator photovoltaic modules in a series of case studies of residential customers, modeling the levelized cost of energy, payback period, and annual bill savings. We find that efficiency can provide significant savings in installed system cost and improve value to the solar system owner. The improvement in value depends on location and the size of the rooftop, as well as the ability of a given technology to collect diffuse light and achieve low module costs.

14 SOLAR ENERGY↗

Tropical root traits in response to global changes from 1984 to 2023

This dataset is a compilation of tropical root traits data in response to different global changes in tropical sites, considering 23.50N and S as latitudinal boundaries. The global changes considered are warming, drought, flooding, cyclones, nitrogen addition, CO2 fertilization, and fire. This dataset contains 266 root trait observations from 93 studies across 24 tropical countries. The full citation from where the data was taken from is provided in the dataset, as well as the global change, the ecosystem type, location, coordinates, the root traits measured, and the direction of their response after the global change. Additional information such as the duration of the experiment, the intensity of the global change, the soil layers from where the roots were collected, the root orders, and the type of experiment are also shown. We obtained this dataset by performing a systematic literature review on Web of Science using standardized keywords in English, Spanish, and Portuguese (Yaffar, Lugli et al. in press).

54 ENVIRONMENTAL SCIENCES↗

Macquarie Island Cloud and Radiation Experiment (MICRE) Field Campaign Report

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility, the Australian Antarctic Division (AAD), and the Australian Bureau of Meteorology (BOM) collaborated in deploying a variety of ground instrumentation to Macquarie Island between March 2016 and March 2018. Macquarie Island is located at 54.5° S, 158.9° E and is well situated for studying clouds over the Southern Ocean. The primary objective of the March 2016 to March 2018 deployment, hereafter the Macquarie Island Cloud and Radiation Experiment (MICRE), was to collect observations of surface radiation, cloud, precipitation, and aerosol properties. This report describes the instruments deployed and data sets collected, along with a summary of key data quality issues and information on some value-added products that are being developed to assist scientists in using the data.

54 ENVIRONMENTAL SCIENCES↗

Hanford Waste Treatment Plant Low Activity Waste Facility Stack Effluent Monitoring - Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant low activity waste (LAW) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAW stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAW stacks are 815–55,758 scfm for LV-S1, 980–112,078 scfm for LV-S2, 264–22,901 scfm for LV-S3, and 981–79,832 scfm for LV-C2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAW facility. Flow angle results were primarily less than 10°, except for one LV-S2 Fan A result, which was 13.2°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 1.5 COV and 9.2% COV, which were all within the range of the target % COV values from the scale model tests. Based on these stack verification test results, the four LAW filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan operating conditions for LV-S1 and LV-S2, dual-fan operations for LV-S3 at both the continuous air monitor and record sampler locations, and both the single-fan as well as the dual-fan operations for LV-C2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Remote Deployment and Setup of VOLTTRON Instances

The goal of this project is to increase the pool of people who can install and configure applications in the Intellimation platform. This will be accomplished with a joint development effort between Intellimation and PNNL to create a set of services to simplify the process for the onsite client as well as the Intellimation staff at a centralized location. Intellimation’s tagging capability, hosted in their cloud, will be leveraged to create an autoconfiguration process for selected PNNL applications such as Intelligent Load Control and AIRCX. The results of the configuration process will be sent to Intellimation field units which host the applications locally. This will allow these applications to be configured remotely and with greatly reduced effort on the part of Intellimation staff. Consequently, this will enable a greater usage of these applications and greater impact to energy efficiency than would be possible without this effort. The use of these newly developed services would allow Intellimation to reduce the cost of installation and allow them to offer the service to new and existing clients.

97 MATHEMATICS AND COMPUTING↗

Methodology to Generate the Decay Gamma Source for a Second Target Station Target Wedge

This report details the specifics of applying the Position-Averaged Method methodology for the calculation of the rotating lasagna-style target wedge activation and the resulting decay gamma source terms. The methodology uses MCNP® Code Version 6.2.0 with the RNUCS patch coupled with CINDER2008 from the AARE V1.0 package. The process begins with model preparations that include ensuring impurities are included in the materials in the regions of interest along with segmentation of the geometry in order to capture the decay gamma source gradients. This report also details the physics models and other MCNP®, CINDER2008, and ADVANTG 3.2.0 related options used to calculate the decay gamma source terms. ADVANTG 3.2.0 is used to generate a weight window set to aid in convergence of the neutron fluxes in the initial MCNP® protons-on-target particle transport calculation to calculate the neutron fluxes and spallation products in the regions of interest. The neutron fluxes and spallation products are then used in the CINDER2008 transmutation calculation, and the decay gamma sources are generated by the AARE_GAMMA_SOURCE_SCRIPT as a part of the AARE V1.0 package. These decay gamma sources include the energy distributions as well as the necessary distributions to sample the location of the source using the cell rejection method. The gamma sources that are produced using the methodology may be used for a wide variety of analysis involving the target wedge. This report includes the material specifications, physics options, proton source term description, geometrical configuration, and post-processing details.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nominal and adversarial synthetic PMU data for standard IEEE test systems

GridSTAGE (Spatio-Temporal Adversarial scenario GEneration) is a framework for the simulation of adversarial scenarios and the generation of multivariate spatio-temporal data in cyber-physical systems. GridSTAGE is developed based on Matlab and leverages Power System Toolbox (PST) where the evolution of the power network is governed by nonlinear differential equations. Using GridSTAGE, one can create several event scenarios that correspond to several operating states of the power network by enabling or disabling any of the following: faults, AGC control, PSS control, exciter control, load changes, generation changes, and different types of cyber-attacks. Standard IEEE bus system data is used to define the power system environment. GridSTAGE emulates the data from PMU and SCADA sensors. The rate of frequency and location of the sensors can be adjusted as well. Detailed instructions on generating data scenarios with different system topologies, attack characteristics, load characteristics, sensor configuration, control parameters are available in the Github repository - https://github.com/pnnl/GridSTAGE. There is no existing adversarial data-generation framework that can incorporate several attack characteristics and yield adversarial PMU data. The GridSTAGE framework currently supports simulation of False Data Injection attacks (such as a ramp, step, random, trapezoidal, multiplicative, replay, freezing) and Denial of Service attacks (such as time-delay, packet-loss) on PMU data. Furthermore, it supports generating spatio-temporal time-series data corresponding to several random load changes across the network or corresponding to several generation changes. A Koopman mode decomposition (KMD) based algorithm to detect and identify the false data attacks in real-time is proposed in https://ieeexplore.ieee.org/document/9303022. Machine learning-based predictive models are developed to capture the dynamics of the underlying power system with a high level of accuracy under various operating conditions for IEEE 68 bus system. The corresponding machine learning models are available at https://github.com/pnnl/grid_prediction.

99 GENERAL AND MISCELLANEOUS↗

Investigation of the Effect of Injected CO 2 on the Morrow B Sandstone through Laboratory Batch Reaction Experiments: Implications for CO 2 Sequestration in the Farnsworth Unit, Northern Texas, USA

About one million tons of CO 2 have been injected into the Farnsworth unit to date. The target reservoir for CO 2 injection is the Morrow B Sandstone, which is primarily made of quartz with lesser amounts of albite, calcite, chlorite, and clay minerals. The impact of CO 2 injection on the mineralogy, porosity, and pore water composition of the Morrow B Sandstone is a major concern. Although numerical modeling studies suggest that porosity changes will be minimal, significant alterations to mineralogy and pore water composition are expected. Given the implications for CO 2 storage effectiveness and risk assessment, it is crucial to verify the accuracy of theoretical model predictions through laboratory experiments. To this end, batch reaction experiments were conducted to model conditions near an injection well in the Morrow B Sandstone and at locations further away, where the CO 2 has been diluted by formation water. The laboratory experiments involved submerging thin sections of both coarse- and fine-grained facies of the Morrow B Sandstone in formation water samples with varying levels of CO 2 . The experiments were conducted at the reservoir temperature of 75 °C. Two experimental runs were conducted, one lasting for 61 days and the other for 72 days. The initial fluid composition used in the second run was the same as in the first. The mineralogy changes in the thin sections were analyzed using SEM and the Tescan Integrated Mineral Analyzer (TIMA), while changes in the composition of the formation water were determined using ICP-AES. During each experiment, a thin layer of white fine-grained particles consisting mainly of dolomite and silica formed on the surface of the thin sections, leading to significant reductions in Ca, Mg, and Sr in the formation water. This outcome is consistent with numerical model predictions that dolomite would be the primary mineral that would react with injected CO 2 and that silica would be oversaturated in the formation water. Changes in mineral abundance in the thin sections themselves were much less systematic than in the theoretical modeling experiments, perhaps reflecting heterogeneities in the mineral grain size surface area to volume ratios and mineral distributions in the thin sections not considered in the numerical models.

58 GEOSCIENCES↗

Baltimore Ecosystem Study: Stream chemistry for core sites in Gwynns Falls

In the Baltimore urban long-term ecological research (LTER) project, (Baltimore Ecosystem Study, BES) we use the watershed approach to evaluate integrated ecosystem function. The LTER research is centered on the Gwynns Falls watershed, a 17,150 ha catchment that traverses a gradient from the urban core of Baltimore, through older urban residential (1900 - 1950) and suburban (1950- 1980) zones, rapidly suburbanizing areas and a rural/suburban fringe. Our long-term sampling network includes four longitudinal sampling sites along the Gwynns Falls as well as several small (40 - 100 ha) watersheds located within or near to the Gwynns Falls. The longitudinal sites provide data on water and nutrient fluxes in the different land use zones of the watershed (rural/suburban, rapidly suburbanizing, old suburban, urban core) and the small watersheds provide more focused data on specific land use areas (forest, agriculture, rural/suburban, urban). Each of the gaging sites is continuously monitored for discharge and is sampled weekly for chemistry. Additional chemical sampling is carried out in a supplemental set of sites to provide a greater range of land use. Weekly analyses includes nitrate, phosphate, total nitrogen, total phosphorus, chloride and sulfate, turbidity, fecal coliforms, temperature, dissolved oxygen and pH. Cations, dissolved organic carbon and nitrogen and metals are measured on selected samples. Streamflow data for this site are posted at: http://waterdata.usgs.gov/md/nwis/nwisman?site_no=015835701

Groffman, Peter M (ORCID:0000000183716255)↗

Enhancing Worker Safety During Off-Site Construction of Energy-Efficient, Low-Carbon Exterior Envelope

The construction industry is not doing enough to embrace off-site modular construction. It is a missed opportunity for optimized energy efficiency because prefabricated exterior wall envelopes are lower in cost and faster and easier to install. Factory off-site construction offers improved safety for construction workers because work is done in a controlled environment, but lack of intent, understanding, and data is also a missed opportunity for enhancing worker safety. This research looks specifically at the prefabricated wall exterior envelope in the context of safety. The research question is "off-site factories build with ease of energy efficiency and lowered carbon emissions, but is the process safer?" This research was funded by NREL Student Training in Applied Research (STAR) program, University Partnerships Program, and Wells Fargo Bank. Key finding is that modular and prefabricated construction are perceived to be safer, but the accident rates are much higher than in the general construction and manufacturing industries. Proposed solutions to decrease accidents in off-site prefabricated construction includes safety training for workers, provide movable kiosks with PPE at workstations, ensure tools are well-maintained and place safety posters in visible locations. Future work includes improving worker safety to increase worker productivity, perform pilot demonstration, work with factory designers for new modular layout for worker safety, i.e., easy access to PPE kiosks, and work closely with OSHA so that they take notice of this safety niche.

drywall↗

Y-12 Groundwater Protection Program Monitoring Well Inspection and Maintenance Plan

This plan describes the systematic approach for: inspecting the physical condition of monitoring wells at Y-12, determining maintenance needs that extend the life of a well, and identifying those wells that no longer meet acceptable monitoring well design or well construction standards and require plugging and abandonment. The inspection and maintenance of groundwater monitoring wells is one of the primary management strategies of the Y-12 Groundwater Protection Program (GWPP) Management Plan, that is, the “proactive stewardship of the extensive monitoring well network at Y-12" (Consolidated Nuclear Security, L.L.C. [CNS], 2018). Effective stewardship, and a program of routine inspections of the physical condition of each monitoring well, ensures that representative water-quality samples and hydrologic data are obtained from the well network and protects the subsurface environment. In accordance with the Y-12 GWPP Monitoring Optimization Plan (MOP) for Groundwater Monitoring Wells at the Y-12 National Security Complex, Oak Ridge, Tennessee (CNS, 2017), the status designation (active or inactive) for each well determines the scope and extent of well inspections and maintenance activities. This plan, in conjunction with the above document, formalizes the GWPP approach to focus available resources on monitoring wells which provide the most useful data, and for that reason the GWPP inspects and performs maintenance on the wells sampled by the GWPP. This plan applies to groundwater monitoring wells installed at Y-12 and the related waste management facilities located within the three hydrogeologic regimes: (1) the Bear Creek Hydrogeologic Regime (Bear Creek Regime), (2) the Upper East Fork Poplar Creek Hydrogeologic Regime (East Fork Regime), and (3) the Chestnut Ridge Hydrogeologic Regime (Chestnut Ridge Regime). The Bear Creek Regime encompasses the section of Bear Creek Valley (BCV) immediately west of Y-12. The East Fork Regime encompasses most of the Y-12 process, operations, and support facilities in BCV west of Scarboro Road. The Chestnut Ridge Regime is directly south of Y-12 and encompasses a section of Chestnut Ridge that is bounded to the west by a surface drainage feature (Dunaway Branch, located immediately west of Industrial Landfill II) and by Scarboro Road to the east. The GWPP maintains an extensive database of geographic and construction details and related information for the monitoring wells in each hydrogeologic regime in the Updated Subsurface Database for Bear Creek Valley, Chestnut Ridge, and Parts of Bethel Valley on the U.S. DOE Oak Ridge Reservation (CNS, 2019). A detailed description of the hydrogeologic framework at Y-12 can be found in the GWPP Management Plan (CNS, 2018).

54 ENVIRONMENTAL SCIENCES↗

Wellbore Fracture Imaging Using Inflow Detection Measurements

One of the most striking measurements taken during DOE’s EGS Collab project at the 4850-foot depth location was the so-called ‘sewer cam’, which enabled direct visualization of the flow of water into the production well through fractures during the stimulation. The ability to see directly which fractures were flowing and (roughly) how much was a breakthrough in understanding the topology of the created fracture network. Achieving this kind of fracture flow imaging at FORGE would be more challenging because of the 225°C temperature, but equally or even more valuable if it could be achieved. In 2017, a joint project between Sandia and Stanford developed a downhole tool concept to measure the enthalpy of multiphase fluid entering a geothermal well from individual fractures (Gao et al., 2017). For the FORGE project, measuring enthalpy is of less interest because the fluid is expected to be single-phase liquid water. However, the foundation of the device was the measurement of chloride ion concentration, which could form the basis for a direct measurement of inflow from fractures. During the 2017 project, this novel chloride sensing system was implemented into a laboratory test instrument, and we confirmed the capability of the system to measure the ion concentration of fluid entering a model wellbore through a small entry port. The wellbore was a 6-inch diameter model well, and the port was approximately 0.08 inch (2mm) in diameter. The device could measure the chloride concentration accurately even when the well was flowing in a bubbly flow. Given its accuracy, the tool should be able to identify locations of water entering the wellbore even if the ion concentration differs only slightly from that of the water in the well. It is likely that different fractures may flow slightly different chloride concentrations, which would make it feasible to detect individual fractures as well as to estimate the volume of their flow. Ultimately, we could also recognize different fractures flowing back significantly different ion concentrations after fracturing in the FORGE wells. This could be realized by adding different ions in the fracturing fluids in different fractures created at different stages of stimulation (and modifying the tool to include different ion specificity). Sandia’s tool was shown during the study to have the capability to withstand the 225°C temperature, and the electrochemical sensing elements were tested in the laboratory to 225°C at 1500 psia for 24 hours. An early implementation of the fully integrated downhole electrochemical tool, including high-temperature electronics, robust housing, and wireline truck interface, had previously been constructed and tested successfully at Sandia; thus, hardware development tasks focused on advancing the technology readiness level (TRL) of this promising technology for FORGE deployment, rather than on developing a new scientific basis for its operation. The data collection electronics in this tool allowed for several other sensors (pressure, temperature, flow spinner) to be implemented in parallel as well. The research was a new collaboration between Stanford and Sandia to modify and refine the tool for FORGE deployment, to make the downhole measurements, and to characterize the evolving fractures.

15 GEOTHERMAL ENERGY↗

Dynamic modeling studies of basin-scale pressure interference and CO 2 plume evolution in multi-well geologic CO 2 storage

This research employs numerical modeling to analyze how CO 2 plumes and pressure fronts evolve when CO 2 is injected into a single storage formation from multiple projects located in proximity. Here, this analysis also evaluates the extent to which injection well spacing alleviates pressure buildup in the absence of active pressure management tactics. The simulation approach was based on a single, homogenous saline aquifer in which CO 2 injection occurs under a one-injector baseline case and several multi-well cases where well spacing varies. Analysis results show that the extent of pressure buildup is in the range of tens or a few hundreds of kilometers and contingent upon the defining pressure buildup demarcating the front edge. For the geological setting evaluated in this paper, our analysis suggests that without active basin pressure management strategies, commercial-scale projects would likely need to be sited far apart to avoid pressure interference from one another. Analysis results show the radius of CO 2 plume varies approximately from 2 to 3 km from injection wells (each injecting 1 Mt/year for 30 years) depending on cases and modeling parameters assumed. Given the pressure interference, this paper thus draws attention to the importance of greater coordination among storage operators and regulatory stakeholders. Because this analysis assumes a very specific geologic setting, this exploratory analysis bears further investigations across other geologic scenarios.

42 ENGINEERING↗

Behavior and mechanisms of Doppler wind lidar error in complex terrain: stable flow case study at Perdigão

A numerical experiment is carried out investigating the magnitude of biases in ground-based lidar measurements in complex flow conditions. Biases assessed include those arising from flow curvature and from the interaction of turbulence with the wind field reconstruction (WFR) algorithms used by a WindCube lidars and anemometers. RANS-CFD and WRF-LES simulations were performed for the Perdig˜ao Field Experiment site for a range of atmospheric conditions. Virtual anemometer and lidar data were generated for four locations: two near exposed ridge tops and two in low-speed regions in the valley. The LES data at these four locations show that the scalar inflation terms (the relation between scalar and vector averaged wind speed) for virtual lidar and virtual cups agree very well with predictions using perturbation theory. While the lidar errors vary greatly with location and height, the contribution from the flow curvature tends to be larger than the differences arising from scalar inflation. For one lidar/mast pair near the ridge top, comparisons between simulations and measurements are carried out for a resonant mountain wave event on June 14th, 2017, and for the whole duration of the Perdigão campaign for winds perpendicular to the ridges. The lidar error during the mountain wave, a period of strong stability and low inversion height, is significantly larger than the campaign average. The sensitivity of the lidar error to atmospheric stability is confirmed by the RANS simulations, which suggests strong sensitivity of flow curvature error to stability conditions and to the shape of the wind speed profile near the top of the boundary layer.

17 WIND ENERGY↗

Parameter space mapping of the Princeton magnetorotational instability experiment

Extensive simulations of the Princeton Magnetorotational Instability (MRI) Experiment with the Spectral/Finite Element code for Maxwell and Navier-Stokes Equations (SFEMaNS) have been performed to map the MRI-unstable region as a function of inner cylinder angular velocity and applied vertical magnetic field. The angular velocities of the outer cylinder and the end-cap rings follow the inner cylinder in fixed ratios optimized for MRI. Here, we first confirm the exponential growth of the MRI linear phase using idealized conducting vertical boundaries (end caps) rotating differentially with a Taylor-Couette profile. Subsequently, we run a multitude of simulations to scan the experimental parameter space and find that the normalized volume-averaged mean-square radial magnetic field, our main instability indicator, rises significantly where MRI is expected. At various locations, the local radial components of fluid velocity and generated magnetic field are well correlated with the volume-averaged indicator. Based on this correlation, a diagnostic system that will measure the radial magnetic field at several locations on the inner cylinder is proposed as the main comparison between simulation and experiment. A detailed analysis of poloidal mode structures in the SFEMaNS code indicates that MRI, rather than Ekman circulation or Rayleigh instability, dominates the fluid behavior in the region where MRI is expected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗