Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Validation Studies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

A Study of Cloud Radiative Forcing and Feedback

The main objective of the grant proposal was to participate in the CERES (Cloud and Earth's Radiant Energy System) Satellite experiment and perform interdisciplinary investigation of NASA's Earth Observing System (EOS). During the grant period, massive amounts of scientific data from diverse platforms have been accessed, processed and archived for continuing use; several software packages have been developed for integration of different data streams for performing scientific evaluation; extensive validation studies planned have been completed culminating in the development of important algorithms that are being used presently in the operational production of data from the CERES. Contributions to the inter-disciplinary science investigations have been significantly more than originally envisioned. The results of these studies have appeared in several refereed journals and conference proceedings. They are listed at the end of this report.

Ramanathan, Veerabhadran↗

Sexual Functioning Among Endometrial Cancer Patients Treated With Adjuvant High-Dose-Rate Intra-Vaginal Radiation Therapy

Purpose: We used the Female Sexual Function Index (FSFI) to investigate the prevalence of sexual dysfunction (SD) and factors associated with diminished sexual functioning in early stage endometrial cancer (EC) patients treated with simple hysterectomy and adjuvant brachytherapy. Methods and Materials: A cohort of 104 patients followed in a radiation oncology clinic completed questionnaires to quantify current levels of sexual functioning. The time interval between hysterectomy and questionnaire completion ranged from <6 months to >5 years. Multivariate regression was performed using the FSFI as a continuous variable (score range, 1.2-35.4). SD was defined as an FSFI score of <26, based on the published validation study. Results: SD was reported by 81% of respondents. The mean ({+-} standard deviation) domain scores in order of highest-to-lowest functioning were: satisfaction, 2.9 ({+-}2.0); orgasm, 2.5 ({+-}2.4); desire, 2.4 ({+-}1.3); arousal, 2.2 ({+-}2.0); dryness, 2.1 ({+-}2.1); and pain, 1.9 ({+-}2.3). Compared to the index population in which the FSFI cut-score was validated (healthy women ages 18-74), all scores were low. Compared to published scores of a postmenopausal population, scores were not statistically different. Multivariate analysis isolated factors associated with lower FSFI scores, including having laparotomy as opposed to minimally invasive surgery (effect size, -7.1 points; 95% CI, -11.2 to -3.1; P<.001), lack of vaginal lubricant use (effect size, -4.4 points; 95% CI, -8.7 to -0.2, P=.040), and short time interval (<6 months) from hysterectomy to questionnaire completion (effect size, -4.6 points; 95% CI, -9.3-0.2; P=.059). Conclusions: The rate of SD, as defined by an FSFI score <26, was prevalent. The postmenopausal status of EC patients alone is a known risk factor for SD. Additional factors associated with poor sexual functioning following treatment for EC included receipt of laparotomy and lack of vaginal lubricant use.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Millimeter-Wave Imaging Radiometer (MIR) Data Processing and Development of Water Vapor Retrieval Algorithms

This document describes the final report of the Millimeter-wave Imaging Radiometer (MIR) Data Processing and Development of Water Vapor Retrieval Algorithms. Volumes of radiometric data have been collected using airborne MIR measurements during a series of field experiments since May 1992. Calibrated brightness temperature data in MIR channels are now available for studies of various hydrological parameters of the atmosphere and Earth's surface. Water vapor retrieval algorithms using multichannel MIR data input are developed for the profiling of atmospheric humidity. The retrieval algorithms are also extended to do three-dimensional mapping of moisture field using continuous observation provided by airborne sensor MIR or spaceborne sensor SSM/T-2. Validation studies for water vapor retrieval are carried out through the intercomparison of collocated and concurrent measurements using different instruments including lidars and radiosondes. The developed MIR water vapor retrieval algorithm is capable of humidity profiling under meteorological conditions ranging from clear column to moderately cloudy sky. Simulative water vapor retrieval studies using extended microwave channels near 183 and 557 GHz strong absorption lines indicate feasibility of humidity profiling to layers in the upper troposphere and improve the overall vertical resolution through the atmosphere.

Chang, L. Aron↗

Resonance Self-Shielding Methodologies in SCALE 6

SCALE 6 includes several problem-independent multigroup (MG) libraries that were processed from the evaluated nuclear data file ENDF/B using a generic flux spectrum. The library data must be self-shielded and corrected for problem-specific spectral effects for use in MG neutron transport calculations. SCALE 6 computes problem-dependent MG cross sections through a combination of the conventional Bondarenko shielding-factor method and a deterministic continuous-energy (CE) calculation of the fine-structure spectra in the resolved resonance and thermal energy ranges. The CE calculation can be performed using an infinite medium approximation, a simplified two-region method for lattices, or a one-dimensional discrete ordinates transport calculation with pointwise (PW) cross-section data. This paper describes the SCALE-resonance self-shielding methodologies, including the deterministic calculation of the CE flux spectra using PW nuclear data and the method for using CE spectra to produce problem-specific MG cross sections for various configurations (including doubly heterogeneous lattices). It also presents results of verification and validation studies.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Baseline Face Detection, Head Pose Estimation, and Coarse Direction Detection for Facial Data in the SHRP2 Naturalistic Driving Study

Keeping a driver focused on the road is one of the most critical steps in insuring the safe operation of a vehicle. The Strategic Highway Research Program 2 (SHRP2) has over 3,100 recorded videos of volunteer drivers during a period of 2 years. This extensive naturalistic driving study (NDS) contains over one million hours of video and associated data that could aid safety researchers in understanding where the driver s attention is focused. Manual analysis of this data is infeasible, therefore efforts are underway to develop automated feature extraction algorithms to process and characterize the data. The real-world nature, volume, and acquisition conditions are unmatched in the transportation community, but there are also challenges because the data has relatively low resolution, high compression rates, and differing illumination conditions. A smaller dataset, the head pose validation study, is available which used the same recording equipment as SHRP2 but is more easily accessible with less privacy constraints. In this work we report initial head pose accuracy using commercial and open source face pose estimation algorithms on the head pose validation data set.

Paone, Jeffrey R↗

Modeling of frequency-sweeping Alfvén modes in the TJ-II stellarator

Alfvénic activity has been observed in the TJ-II stellarator which resembles the frequency sweeping demonstrated by Alfvén cascade modes in tokamaks. A numerical validation study was conducted using a reduced magnetohydrodynamic (MHD) model to show that such modes could only have been observed in discharges where the rotational transform profile was non-monotonic. During experiments, coil current was varied which resulted in shifting of the minimum value of the rotational transform profile. To mimic this effect, we study the Alfvénic activity predicted by the reduced MHD model for a set of input rotational transform profiles with varying minima. A mode is found whose toroidal and poloidal mode numbers match those predicted in experiments which sweeps downward/upward in frequency as the minimum value of the rotational transform profile is increased/decreased. The results serve as a demonstration of the validity and utility of MHD spectroscopy.

Alfvén cascades↗

Satellite-Based Stratospheric and Tropospheric Measurements: Determination of Global Ozone and Other Trace Species

This grant is an extension to our previous NASA Grant NAG5-3461, providing incremental funding to continue GOME (Global Ozone Monitoring Experiment) and SCIAMACHY (SCanning Imaging Absorption SpectroMeter for Atmospheric CHartographY) studies. This report summarizes research done under these grants through December 31, 2002. The research performed during this reporting period includes development and maintenance of scientific software for the GOME retrieval algorithms, consultation on operational software development for GOME, consultation and development for SCIAMACHY near-real-time (NRT) and off-line (OL) data products, and participation in initial SCIAMACHY validation studies. The Global Ozone Monitoring Experiment was successfully launched on the ERS-2 satellite on April 20, 1995, and remains working in normal fashion. SCIAMACHY was launched March 1, 2002 on the ESA Envisat satellite. Three GOME-2 instruments are now scheduled to fly on the Metop series of operational meteorological satellites (Eumetsat). K. Chance is a member of the reconstituted GOME Scientific Advisory Group, which will guide the GOME-2 program as well as the continuing ERS-2 GOME program.

Chance, Kelly↗

Root angle in maize influences nitrogen capture and is regulated by calcineurin B-like protein (CBL)-interacting serine/threonine-protein kinase 15 ( ZmCIPK15 )

Crops with reduced nutrient and water requirements are urgently needed in global agriculture. Root growth angle plays an important role in nutrient and water acquisition. A maize diversity panel of 481 genotypes was screened for variation in root angle employing a high-throughput field phenotyping platform. Genome-wide association mapping identified several single nucleotide polymorphisms (SNPs) associated with root angle, including one located in the root expressed CBL-interacting serine/threonine-protein kinase 15 (ZmCIPK15) gene (LOC100285495). Reverse genetic studies validated the functional importance of ZmCIPK15, causing a approximately 10° change in root angle in specific nodal positions. A steeper root growth angle improved nitrogen capture in silico and in the field. OpenSimRoot simulations predicted at 40 days of growth that this change in angle would improve nitrogen uptake by 11% and plant biomass by 4% in low nitrogen conditions. In field studies under suboptimal N availability, the cipk15 mutant with steeper growth angles had 18% greater shoot biomass and 29% greater shoot nitrogen accumulation compared to the wild type after 70 days of growth. We propose that a steeper root growth angle modulated by ZmCIPK15 will facilitate efforts to develop new crop varieties with optimal root architecture for improved performance under edaphic stress.

59 BASIC BIOLOGICAL SCIENCES↗

Developing the hybrid scenario in DIII-D and KSTAR for W-compatible long-pulse operation

Long-pulse, high-performance operation with tungsten plasma-facing components is a crucial challenge for achieving steady-state (SS) goals in ITER and future fusion devices. This paper presents a joint international effort between the DIII-D and KSTAR tokamaks aimed at demonstrating the compatibility of the high q 95 ~ 6 hybrid scenario with a tungsten divertor and superconducting coils. A DIII-D hybrid scenario recipe is successfully tailored to KSTAR’s operational constraints, which facilitates cross-device studies. The results show successful 30 s long-pulse operation in KSTAR at a normalized beta (β N = 2.4) with a benign m/n = 4/3 mode and effective mitigation of tungsten accumulation. Despite this success, the KSTAR scenario exhibits a greater than 25% reduction in thermal confinement compared to the DIII-D reference. To investigate this discrepancy, we performed a predictive TGYRO validation study, which suggests that the difference is likely caused by a weaker temperature pedestal in the KSTAR discharge due to a higher and narrower density pedestal. In addition, such lower thermal confinement leads to higher impurity accumulation, possibly due to a change in neoclassical transport with increased inward pinch, which further degrades global confinement. We also report that stationary, long-pulse operation with sustained thermal confinement requires consistent fueling and wall conditioning. These findings highlight the importance of optimized fueling and real-time wall conditioning in achieving a high temperature pedestal and strong global confinement during stable long-pulse operation. We propose potential approaches toward fully SS, long-pulse operation, including real-time wall conditioning using an impurity dropper in KSTAR and future tokamaks.

DIII-D↗

Risk of Crew Adverse Health Event Due to Altered Immune Response

Determining the effect of space travel on the human immune system has proven to be extremely challenging. Limited opportunities for in-flight studies, varying mission durations, technical and logistical obstacles, small subject numbers, and a broad range of potential assays have contributed to this problem. Additionally, the inherent complexity of the immune system, with its vast array of cell populations, sub-populations, diverse regulatory molecules, and broad interactions with other physiological systems, makes determining precise variables to measure very difficult. There is also the challenge of determining the clinical significance of any observed immune alterations. Will such a change lead to disease, or is it a transient subclinical observation related to short-term stress? The effect of this problem may be observed by scanning publications associated with immunity and spaceflight, which began to appear during the 1970s. Although individually they are each valid studies, the comprehensive literature to date suffers from widely varying sampling methods and assay techniques, low subject counts, and sometimes a disparate focus on narrow aspects of immunity. The most clinically relevant data are derived from in-flight human studies, which have demonstrated altered cell-mediated immunity and reactivation of latent herpes viruses. Much more data are available from post-flight testing of humans, with clear evidence of altered cytokine production patterns, altered leukocyte distribution, continued latent viral reactivation, and evidence of dramatically altered virus-specific immunity. It is unknown if post-flight assessments relate to the in-flight condition or are a response to landing stress and readaptation. In-flight culture of cells has clearly demonstrated that immune cells are gravity-sensitive and display altered functional characteristics. It is unknown if these data are related to in vivo immune cell function or are an artifact of microgravity culture. Ground analog testing of humans and animals, as well as microgravity-analog cell culture, has demonstrated utility. However, in all cases, it is not known with certainty if these data would reflect similar testing during space travel. Given their ready availability, ground analogs may be extremely useful for assay development and the evaluation of potential countermeasures. In general, the evidence base suffers from widely disparate studies on small numbers of subjects that do not directly correlate well with each other or spaceflight itself. Also lacking are investigations of the effect of gender on adaption to spaceflight. This results in significant knowledge 'gaps' that must be filled by future studies to completely determine any clinical risk related to immunity for human exploration-class space missions. These gaps include a significant lack of in-flight data, particularly during long-duration space missions. The International Space Station represents an excellent science platform with which to address this knowledge gap. Other knowledge gaps include lack of a single validated ground analog for the phenomenon and a lack of flight-compatible laboratory equipment capable of monitoring astronauts (for either clinical or research purposes). However, enough significant data exist, as described in this manuscript, to warrant addressing this phenomenon during the utilization phase of the ISS. A recent Space Shuttle investigation has confirmed the 31 in-flight nature of immune dysregulation, demonstrating that it is not merely a post-flight phenomenon. Several current studies are ongoing onboard the ISS that should thoroughly characterize the phenomenon. NASA recognizes that if spaceflight-associated immune dysregulation persists during exploration flights in conjunction with other dangers, such as high-energy radiation, the result may be a significant clinical risk. This emphasizes the need for a continued integrated comprehensive approach to determining the effect of prolonged spaceflight, separated from transient launch and landing stresses, on human immunity. After such studies, the phenomenon will be understood, and, hopefully, a monitoring strategy will have been developed that could be used to monitor the effectiveness of countermeasure

Crucian, Brian↗

BIOCOMPATIBLE FLUORESCENT MICROSPHERES: SAFE PARTICLES FOR MATERIAL PENETRATION STUDIES

Biocompatible polymers with hydrolyzable chemical bonds have been used to produce safe, non-toxic fluorescent microspheres for material penetration studies. The selection of polymeric materials depends on both biocompatibility and processability, with tailored fluorescent properties depending on specific applications. Microspheres are composed of USFDA-approved biodegradable polymers and non-toxic fluorophores and are therefore suitable for tests where human exposure is possible. Micropheres were produced which contain unique fluorophores to enable discrimination from background aerosol particles. Characteristics that affect dispersion and adhesion can be modified depending on use. Several different microsphere preparation methods are possible, including the use of a vibrating orifice aerosol generator (VOAG), a Sono-Tek atomizer, an emulsion technique, and inkjet printhead. Applications for the fluorescent microspheres include challenges for biodefense system testing, calibrants for biofluorescence sensors, and particles for air dispersion model validation studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Validation of the Computational Fluid Dynamics Method using the Aboveground Configuration of the Dry Cask Simulator

Dry cask applicants submit their spent nuclear fuel dry storage and transportation cask designs to the U.S. Nuclear Regulatory Commission (NRC) for certification under Title 10 of the Code of Federal Regulations (10 CFR) Part 72, 'Licensing Requirements for the Independent Storage of Spent Nuclear Fuel, High-Level Radioactive Waste, and Reactor-Related Greater Than Class C Waste'. The NRC staff performs its technical review of these designs in accordance with 10 CFR Part 72 and NUREG-1536, 'Standard Review Plan for Spent Fuel Dry Storage Systems at a General License Facility,' Revision 1, issued July 2010. To ensure that the cask and fuel material temperatures of the dry cask storage system remain within the allowable limits or criteria for normal, off-normal, and accident conditions, the NRC staff performs a thermal review as part of the technical review. Recent applications increasingly have used thermalhydraulic analyses using computational fluid dynamics (CFD) codes (e.g., ANSYS FLUENT) to demonstrate the adequacy of the thermal design. The NRC performs validation studies of the FLUENT CFD code to assist it in making regulatory decisions to ensure adequate protection for storage and transportation casks. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a cask in part by increasing the efficiency of internal conduction pathways and by increasing the internal convection through greater canister helium pressure. In efforts to further validate these designs, the NRC in conjunction with the Department of Energy and Sandia National Laboratories (SNL) are conducting an experiment to capture the effects of elevated helium pressures and accurately portray the external convection of aboveground and belowground canister dry cask systems.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of the Integrated Medical Model Predictions to Real World ISS and STS Observations

The Human Research Program funded the development of the integrated medical model (IMM) to quantify the medical component of overall mission risk. The IMM uses Monte Carlo methodology to integrate space flight and ground medical data to assess the probability of mission medical outcomes and resource utilization. To determine the credibility of IMM output the IMM project team completed two validation studies that compare IMM output to observed medical events from a selection of Shuttle Transportation System (STS) and International Space Station (ISS) missions.

validation↗

Implementation of new PRODIAG algorithm and simulation-based acceptance test - 219

This paper presents the improvement of an automated-reasoning computer program for nuclear power plant diagnosis, namely PRODIAG. PRODIAG, first developed at the Argonne National Laboratory, uses confluence-based reasoning to perform fault diagnosis in engineering systems that can be described by the conservation laws for mass, energy, and momentum. Therefore, unlike other plant configuration-dependent rule-based diagnosis algorithms, the code is generally applicable to a wide variety of plant configurations by simply replacing the plant instrumentation diagram (PID) database. The need for improvement was raised when the original PRODIAG failed to provide the requisite degree of extensibility and maintainability for new applications. These shortcomings have been addressed through a new code architecture that uses an objected-oriented logic-programming language in place of the original Prolog language and uses an open-source automated reasoning engine in place of the original hardwired rule-evaluation sequence. This paper presents the architecture and implementation details of the code transition. Verification and validation studies were performed for the new PRODIAG, which involved re-running the distinct fault cases defined at the time the code was originally developed. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Final Report of the Simulation Optimization Task Force

This is the final report of the ATLAS Simulation Optimization Task Force, establishedin June of 2007. This note justifies the selected Geant4 version, physics list, and range cuts to be used by the default ATLAS simulation for initial data taking and beyond. The current status of several projects, including detector description, simulation validation, studies of additional Geant4 parameters, and cavern background, are reported.

79 ASTRONOMY AND ASTROPHYSICS↗

Assessing Tsunami Vulnerabilities of Geographies with Shallow Water Equations

Tsunami preparedness is crucial for saving human lives in case of disasters that involve massive water movement. In this work, we develop a framework for visual assessment of tsunami preparedness of geographies. Shallow water equations (also called Saint Venant equations) are a set of hyperbolic partial differential equations that are derived by depth-integrating the Navier-Stokes equations and provide a great abstraction of water masses that have lower depths compared to their free surface area. Our specific contribution in this study is to use Microsoft's XNA Game Studio to import underwater and shore line geographies, create different tsunami scenarios, and visualize the propagation of the waves and their impact on the shore line geography. Most importantly, we utilized the computational power of graphical processing units (GPUs) as HLSL based shader files and delegated all of the heavy computations to the GPU. Finally, we also conducted a validation study, in which we have tested our model against a controlled shallow water experiment. We believe that such a framework with an easy to use interface that is based on readily available software libraries, which are widely available and easily distributable, would encourage not only researchers, but also educators to showcase ideas.

Aras, Rifat↗

Neutrino Interaction Identification for the DUNE Trigger

The DUNE will be a long baseline neutrino oscillation experiment using a high purity muon neutrino beam and near detector, both located at the FNAL, and a far detector hosted 1300 km downstream at the SURF. The 10 kt fiducial mass of LAr will allow DUNE to have a rich off-beam neutrino physics programme, including the study of neutrino signals from core collapse supernovae. The SP DUNE FD module will read out ionisation data at a rate of 1.2 TB\textsuperscript{-1} whilst only a total data volume of 30 PB per year can be permanently stored. DUNE will make use of FPGA resources in the front-end of the DAQ as part of the necessitated triggering system. This thesis presents a validation study of the FPGA-based TPG in the front-end DAQ using data collected by the ProtoDUNE experiment hosted at the CERN. The FPGA-based TPG was utilised as the first stage of a baseline SNB trigger whose performance was evaluated using simulated neutrino interactions for a $11.2 m_\odot$ progenitor star. The efficiency of the baseline SNB trigger was determined to have a lower limit of $97.7\substack{+ 0.2\\ -0.3}\%$ for supernovae at a distance of 20kpc, achieving the technical requirements set out for DUNE. To improve the performance of the SNB trigger at greater SNB distances, the use of a bounding box proposal network, YOLOv3, was explored. This was found to improve the efficiency of the SNB trigger to 100\% up to the far side of the Milky Way galaxy and to $92.5\substack{+ 0.5\\ -0.5}\%$ at the Large Magellanic Cloud.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

VMAT QA: Measurement-guided 4D dose reconstruction on a patient

Purpose: To develop and validate a volume-modulated arc therapy (VMAT) quality assurance (QA) tool that takes as input a time-resolved, low-density ({approx}10 mm) cylindrical surface dose map from a commercial helical diode array, and outputs a high density, volumetric, time-resolved dose matrix on an arbitrary patient dataset. This first validation study is limited to a homogeneous 'patient.'Methods: A VMAT treatment is delivered to a diode array phantom (ARCCHECK, Sun Nuclear Corp., Melbourne, FL). 3DVH software (Sun Nuclear) derives the high-density volumetric dose using measurement-guided dose reconstruction (MGDR). MGDR cylindrical phantom results are then used to perturb the three-dimensional (3D) treatment planning dose on the patient dataset, producing a semiempirical volumetric dose grid. Four-dimensional (4D) dose reconstruction on the patient is also possible by morphing individual sub-beam doses instead of the composite. For conventional (3D) dose comparison two methods were developed, using the four plans (Multi-Target, C-shape, Mock Prostate, and Head and Neck), including their structures and objectives, from the AAPM TG-119 report. First, 3DVH and treatment planning system (TPS) cumulative point doses were compared to ion chamber in a cube water-equivalent phantom ('patient'). The shape of the phantom is different from the ARCCHECK and furthermore the targets were placed asymmetrically. Second, coronal and sagittal absolute film dose distributions in the cube were compared with 3DVH and TPS. For time-resolved (4D) comparisons, three tests were performed. First, volumetric dose differences were calculated between the 3D MGDR and cumulative time-resolved patient (4D MGDR) dose at the end of delivery, where they ideally should be identical. Second, time-resolved (10 Hz sampling rate) ion chamber doses were compared to cumulative point dose vs time curves from 4D MGDR. Finally, accelerator output was varied to assess the linearity of the 4D MGDR with global fluence change. Results: Across four TG-119 plans, the average PTV point dose difference in the cube between 3DVH and ion chamber is 0.1 {+-} 1.0%. Average film vs TPS {gamma}-analysis passing rates are 83.0%, 91.1%, and 98.4% for 1%/2 mm, 2%/2 mm, and 3%/3 mm threshold combinations, respectively, while average film vs 3DVH {gamma}-analysis passing rates are 88.6%, 96.1%, and 99.5% for the same respective criteria. 4D MGDR was also sufficiently accurate. First, for 99.5% voxels in each case, the doses from 3D and 4D MGDR at the end of delivery agree within 0.5%local dose-error/1 mm distance. Moreover, all failing voxels are confined to the edge of the cylindrical reconstruction volume. Second, dose vs time curves track between the ion chamber and 4D MGDR within 1%. Finally, 4D MGDR dose changes linearly with the accelerator output: the difference between cumulative ion chamber and MGDR dose changed by no more than 1% (randomly) with the output variation range of 10%. Conclusions: Even for a well-commissioned TPS, comparison metrics show better agreement on average to MGDR than to TPS on the arbitrary-shaped measurable 'patient.' The method requires no more accelerator time than standard QA, while producing more clinically relevant information. Validation in a heterogeneous thoracic phantom is under way, as is the ultimate application of 4D MGDR to virtual motion studies.

60 APPLIED LIFE SCIENCES↗