Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VOLTAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Impact of Solar Array Designs on High Voltage Operations

As power levels of advanced spacecraft climb above 25 kW, higher solar array operating voltages become attractive. Even in today s satellites, operating spacecraft buses at 100 V and above has led to arcing in GEO communications satellites, so the issue of spacecraft charging and solar array arcing remains a design problem. In addition, micrometeoroid impacts on all of these arrays can also lead to arcing if the spacecraft is at an elevated potential. For example, tests on space station hardware disclosed arcing at 75V on anodized A1 structures that were struck with hypervelocity particles in Low Earth Orbit (LEO) plasmas. Thus an understanding of these effects is necessary to design reliable high voltage solar arrays of the future, especially in light of the Vision for Space Exploration of NASA. In the future, large GEO communication satellites, lunar bases, solar electric propulsion missions, high power communication systems around Mars can lead to power levels well above 100 kW. As noted above, it will be essential to increase operating voltages of the solar arrays well above 80 V to keep the mass of cabling needed to carry the high currents to an acceptable level. Thus, the purpose of this paper is to discuss various solar array approaches, to discuss the results of testing them at high voltages, in the presence of simulated space plasma and under hypervelocity impact. Three different types of arrays will be considered. One will be a planar array using thin film cells, the second will use planar single or multijunction cells and the last will use the Stretched Lens Array (SLA - 8-fold concentration). Each of these has different approaches for protection from the space environment. The thin film cell based arrays have minimal covering due to their inherent radiation tolerance, conventional GaAs and multijunction cells have the traditional cerium-doped microsheet glasses (of appropriate thickness) that are usually attached with Dow Corning DC 93-500 silicone adhesive. In practice, these cover glasses and adhesive do not cover the cell edges. Finally, in the SLA, the entire cell and cell edges are fully encapsulated by a cover glass that overhangs the cell perimeter and the silicone adhesive covers the cell edges providing a sealed environment. These three types of blanket technology have been tested at GRC and Auburn. The results of these tests will be described. For example, 15 modules composed of four state-of-the-art 2x4 cm GaAs solar cells with 150 pm cover glasses connected in two-cell series strings were tested at high voltage, in plasma under hypervelocity impact. A picture of one of the modules is shown in figure 1. These were prepared by standard industry practice from a major supplier and had efficiencies above 18%. The test results and other fabrication factors that influenced the tests will be presented. In addition, results for SLA segments tested under the same conditions will be presented. Testing of thin film blankets at GRC will also be presented. Figure 1 : Typical GaAs Solar Cell Module These results will show significant differences in resistance to arcing that are directly related to array design and manufacturing procedures. Finally, the approaches for mitigating the problems uncovered by these tests will be described. These will lay the foundation for future higher voltage array operation, even including voltages above 300-600 V for direct drive SEP applications.

Brandhorst, Henry W., Jr.↗

High-Voltage, Low-Power BNC Feedthrough Terminator

This innovation is a high-voltage, lowpower BNC (Bayonet Neill-Concelman) feedthrough that enables the user to terminate an instrumentation cable properly while connected to a high voltage, without the use of a voltage divider. This feedthrough is low power, which will not load the source, and will properly terminate the instrumentation cable to the instrumentation, even if the cable impedance is not constant. The Space Shuttle Program had a requirement to measure voltage transients on the orbiter bus through the Ground Lightning Measurement System (GLMS). This measurement has a bandwidth requirement of 1 MHz. The GLMS voltage measurement is connected to the orbiter through a DC panel. The DC panel is connected to the bus through a nonuniform cable that is approximately 75 ft (approximately equal to 23 m) long. A 15-ft (approximately equal to 5-m), 50-ohm triaxial cable is connected between the DC panel and the digitizer. Based on calculations and simulations, cable resonances and reflections due to mismatched impedances of the cable connecting the orbiter bus and the digitizer causes the output not to reflect accurately what is on the bus. A voltage divider at the DC panel, and terminating the 50-ohm cable properly, would eliminate this issue. Due to implementation issues, an alternative design was needed to terminate the cable properly without the use of a voltage divider. Analysis shows how the cable resonances and reflections due to the mismatched impedances of the cable connecting the orbiter bus and the digitizer causes the output not to reflect accurately what is on the bus. After simulating a dampening circuit located at the digitizer, simulations were performed to show how the cable resonances were dampened and the accuracy was improved significantly. Test cables built to verify simulations were accurate. Since the dampening circuit is low power, it can be packaged in a BNC feedthrough.

Bearden, Douglas↗

Hybrid-PIC Modeling of a High-Voltage, High-Specific-Impulse Hall Thruster

The primary life-limiting mechanism of Hall thrusters is the sputter erosion of the discharge channel walls by high-energy propellant ions. Because of the difficulty involved in characterizing this erosion experimentally, many past efforts have focused on numerical modeling to predict erosion rates and thruster lifespan, but those analyses were limited to Hall thrusters operating in the 200-400V discharge voltage range. Thrusters operating at higher discharge voltages (V(sub d) >= 500 V) present an erosion environment that may differ greatly from that of the lower-voltage thrusters modeled in the past. In this work, HPHall, a well-established hybrid-PIC code, is used to simulate NASA's High-Voltage Hall Accelerator (HiVHAc) at discharge voltages of 300, 400, and 500V as a first step towards modeling the discharge channel erosion. It is found that the model accurately predicts the thruster performance at all operating conditions to within 6%. The model predicts a normalized plasma potential profile that is consistent between all three operating points, with the acceleration zone appearing in the same approximate location. The expected trend of increasing electron temperature with increasing discharge voltage is observed. An analysis of the discharge current oscillations shows that the model predicts oscillations that are much greater in amplitude than those measured experimentally at all operating points, suggesting that the differences in oscillation amplitude are not strongly associated with discharge voltage.

Hall Thrusters↗

Architecture, Voltage, and Components for a Turboelectric Distributed Propulsion Electric Grid

The development of a wholly superconducting turboelectric distributed propulsion system presents unique opportunities for the aerospace industry. However, this transition from normally conducting systems to superconducting systems significantly increases the equipment complexity necessary to manage the electrical power systems. Due to the low technology readiness level (TRL) nature of all components and systems, current Turboelectric Distributed Propulsion (TeDP) technology developments are driven by an ambiguous set of system-level electrical integration standards for an airborne microgrid system (Figure 1). While multiple decades' worth of advancements are still required for concept realization, current system-level studies are necessary to focus the technology development, target specific technological shortcomings, and enable accurate prediction of concept feasibility and viability. An understanding of the performance sensitivity to operating voltages and an early definition of advantageous voltage regulation standards for unconventional airborne microgrids will allow for more accurate targeting of technology development. Propulsive power-rated microgrid systems necessitate the introduction of new aircraft distribution system voltage standards. All protection, distribution, control, power conversion, generation, and cryocooling equipment are affected by voltage regulation standards. Information on the desired operating voltage and voltage regulation is required to determine nominal and maximum currents for sizing distribution and fault isolation equipment, developing machine topologies and machine controls, and the physical attributes of all component shielding and insulation. Voltage impacts many components and system performance.

electric faults↗

Impact of Distribution Feeders that do not have Voltage Regulators on the number of Charged Electric Vehicles using IEEE 34 Bus Test Feeder

Voltage regulators help maintain an acceptable voltage profile for the system. This paper discusses the effect of installing voltage regulators to the system to fix the voltage drop resulting from the electrical vehicles loading increase when they are being charged. The effect will be studied in the afternoon, when the peak load occurs, using the IEEE 34 bus test feeder. First, only one spot node is used to charge the electric vehicles while a voltage regulator is present. Second, five spot nodes are loaded at the same time to charge the electric vehicles while voltage regulators are installed at each node. After that, the impact of electric vehicles on distribution feeders that do not have voltage regulators will appear.

Allehyani, Ahmed↗

Voltage control utilizing multiple PWM patterns

A power-delivery system may comprise a load device and a direct-current converter configured to deliver current to the load device when the direct-current converter is in an on state. The power-deliver system may comprise a voltage-measurement system configured to measure, at a beginning of each measurement cycle in a cyclic measurement pattern, a voltage at the load device. The power-deliver system may comprise a power controller configure to receive, at the beginning of each measurement cycle, the measurement of the voltage, and to perform, at the beginning of a control cycle in a cyclic control pattern, a voltage-control decision in response to a change in the measurement of the voltage being below a voltage-change threshold. The voltage-control decision may comprise whether to switch the state of the first direct-current converter. The cyclic control pattern may operate at a first frequency, and the measurement pattern may operate at a second frequency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Voltage control utilizing multiple PWM patterns

A power-delivery system may comprise a load device and a direct-current converter configured to deliver current to the load device when the direct-current converter is in an on state. The power-deliver system may comprise a voltage-measurement system configured to measure, at a beginning of each measurement cycle in a cyclic measurement pattern, a voltage at the load device. The power-deliver system may comprise a power controller configure to receive, at the beginning of each measurement cycle, the measurement of the voltage, and to perform, at the beginning of a control cycle in a cyclic control pattern, a voltage-control decision in response to a change in the measurement of the voltage being below a voltage-change threshold. The voltage-control decision may comprise whether to switch the state of the first direct-current converter. The cyclic control pattern may operate at a first frequency, and the measurement pattern may operate at a second frequency.

Ferencz, Andrew↗

Understanding What Limits the Voltage of Polycrystalline CdSeTe Solar Cells

The origin of voltage deficits in polycrystalline cadmium selenide telluride (CdSeTe) solar cells is unclear. Here, we present a comprehensive voltage loss analysis performed on state-of-the-art CdSeTe devices - fabricated at Colorado State University and First Solar - using photoluminescence techniques, including external radiative efficiency (ERE) measurements. More specifically, we report the thermodynamic voltage limit Voc,ideal, internal voltage iVoc and external voltage Voc of partially and fully finished cells fabricated with different dopant species, dopant concentrations and back contacts. Arsenic-doped aluminium-oxide-passivated cells made at Colorado State University present remarkably high ERE (>1%) - translating into iVoc above 970 mV - but suffer from poor back-contact selectivity. On the other hand, arsenic-doped devices from First Solar present almost perfect carrier selectivity (Voc=iVoc), leading to Voc above 840 mV, and are limited by recombination in various parts of the device. Thus, development of contact structures that are both passivating and selective in combination with highly luminescent absorbers is key to reducing voltage losses.

CdSeTe devices↗

An FPGA-Based Voltage Balancing Control for Multi-HV-IGBTs in Series Connection

The series connection of insulated gate bipolar transistors (IGBTs) allows operation at voltage levels higher than the rated voltage of one IGBT and has less power semiconductor costs compared to multilevel topologies. However, voltage unbalance during the switching transient is a challenge for series-connected device application. This paper presents an field-programmable gate array (FPGA)-based voltage balancing strategy for multiseries-connected high-voltage (HV)-IGBTs including an FPGA-based active voltage balancing control (AVBC) circuit integrated into the gate driver and the control for multiseries-connected IGBTs. As a result, the effectiveness of the control has been experimentally validated in a prototype using four 4.5 kV HV-IGBTs in series connection.

42 ENGINEERING↗

Negative Medium-Voltage Direct Current Discharges in Air under Simulated Sub-Atmospheric Pressures for All-Electric Aircraft

The increase in the global temperature due to greenhouse gas emissions is a major concern to the world. To achieve the goal of zero emissions by 2050 in the USA the practical realization of all-electric vehicles, particularly all-electric aircraft (AEA), is important. For the design of electrical power systems (EPSs) in all-electric aircraft, a bipolar medium-voltage direct current (MVDC) system of ±5 kV is being investigated. However, several challenges manifest when using such voltages in a low-pressure environment. One of the main challenges is the partial discharge (PD) behavior of the insulation. It is important to study the PD behavior of the insulation by simulating the aviation environment in the lab. This work aimed to study the partial discharge behavior of air under a negative DC voltage in a needle-to-plane electrode geometry by simulating the aviation pressures in the lab. The partial discharge inception voltage (PDIV) and the breakdown voltage (BDV) show an obvious pressure-dependent variation. Regression analysis was performed to better understand the relationship between the PDIV and pressures. Plots were drawn for the average discharge current at each voltage step until breakdown. This paper’s findings can provide valuable insight into the design of EPS for an AEA. To the best of our knowledge, such a study has not been carried out to date.

air discharge↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Conservation Voltage Reduction with Distributed Energy Resource Management System, Grid-Edge, and Legacy Devices

Distribution utilities use conservation voltage reduction (CVR) to obtain energy savings and lower peak demand by reducing bus voltages. Traditionally, the CVR is accomplished by controlling the legacy assets such as load tap changers, voltage regulators, and capacitor banks. The deployment of the advanced distribution management system (ADMS) and distributed energy resource management system (DERMS) enables the integration of distributed energy resources into the distribution networks and provide the grid services including CVR. This paper studies the coordinated operation of an ADMS and a DERMS in achieving CVR and voltage regulation. A commercial ADMS uses legacy devices and Edge-of-Network Grid Optimization (ENGO) devices to obtain energy savings through CVR. A prototype DERMS dispatches the photovoltaic smart inverters based on real-time optimal power low to ensure voltage regulation across the feeder. The results show that the coordinated operation of ADMS and DERMS is effective in achieving CVR and voltage regulation. Specifically, energy savings of up to 4.7% are observed in the real utility distribution system used in this study.

advanced distribution management system↗

Nonradiative Recombination Dominates Voltage Losses in Cu(In,Ga)Se 2 Solar Cells Fabricated using Different Methods

Voltage losses reduce the photovoltaic conversion efficiency of thin‐film solar cells and are a primary efficiency limitation in Cu(In,Ga)Se 2 . Herein, voltage loss analysis of Cu(In,Ga)Se 2 solar cells fabricated at three institutions with variation in process, bandgap, absorber structure, postdeposition treatment (PDT), and efficiency is presented. Nonradiative voltage losses due to Shockley–Read–Hall charge carrier recombination dominate and constitute >75% of the total compared to <25% from radiative voltage losses. The radiative voltage loss results from nonideal absorption and carriers in band tails that stem from local composition‐driven potential fluctuations. It is shown that significant bulk lifetime improvements are achieved for all alkali PDT processed absorbers, chiefly associated with reductions in nonradiative recombination. Primary voltage loss contributions (radiative and nonradiative) change little across fabrication processes, but variation in submechanisms (bulk lifetime, net acceptor concentration, and interface recombination) differentiate nonradiative loss pathways in this series of solar cells.

14 SOLAR ENERGY↗

A centralized-based method to determine the local voltage control strategies of distributed generator operation in active distribution networks

The increasing penetration of distributed generators (DGs) exacerbates the risk of voltage violations in active distribution networks (ADNs). The var capacity provided by DG inverters is a potential solution for voltage regulation. The conventional centralized control strategies limited by computation and communication burdens are difficult to meet the requirement of rapid voltage control. However, the local control strategies based on real-time measurements have a fast response to the frequent fluctuations of DG outputs. The performance of these local controllers depends on the tuning of the control parameters. This paper proposes a centralized-based method to determine the local voltage control strategies for DGs. A centralized parameter tuning model of control curves is built, in which and curves of DG inverters are mathematically formulated based on piecewise linearization. The original mixed-integer nonlinear programming (MINLP) model is converted into an effectively solved mixed-integer second-order cone programming (MISOCP) model using convex relaxation. The potential benefits of DG inverters are explored to regulate both reactive and curtailed active power, based on local voltage measurements. Case studies on a modified PG&E 69-node distribution system are carried out to verify the effectiveness of the proposed method. Results show that power losses of ADNs are significantly reduced and voltage profiles are also improved.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact Studies and Cooperative Voltage Control for High PV Penetration

The drastically increasing penetration of photovoltaic (PV) has posed tremendous challenges in operation, control, and protection in distribution networks. The over-voltage issue is one of major concerns for extremely high PV penetration (e.g. 100%). It is critical to identify the most sensitive locations to high PV penetration and apply effective methods to mitigate the over-voltage issue. This paper introduced a novel greedy search algorithm to locate worst-case scenarios of over-voltage in both distributed and centralized PV configurations, as well as a cooperative voltage control method to mitigate over-voltage. The search algorithm has the computational advantage over existing stochastic approach and provides more insights in impact studies. The cooperative control method relies upon reactive power compensation to converge system voltage to a predefined value within standard limits. Moreover, a clustering strategy is applied to divide the network into several clusters, within which all nodes share information with neighboring nodes following a scalable communication architecture. The control algorithms and communication hierarchies presented in this paper have been implemented into OpenDSS to form the Multi Agent (MA) OpenDSS package, which has been made available to the reader. The effectiveness of developed methods are demonstrated through simulation studies on the IEEE 123-node test feeder under four different load levels.

Cooperative control↗

Focusing ions at atmospheric pressure using nonlinear DC voltage sequences applied to a stacked ring ion guide

Many modern ion mobility (IM) and mass spectrometers (MS) operate under low pressure (= 10 Torr) and employ high voltage radiofrequencies (RF) to provide ion confinement. Unfortunately, RF effectiveness drastically decreases as pressure increases, and few techniques for focusing ions at elevated pressures exist. Here we demonstrate a new approach for focusing ions at atmospheric pressure (AP) by applying nonlinear DC voltage sequences following quadratic and power (exponential) functions to a stacked ring ion guide. In this work, we used ion trajectory simulations to rigorously explore how ions react to nonlinear electric fields and validate the simulations with a set of ion current measurements performed at AP. Ion trajectory simulations show that ions initially defocus near the entrance of the device but then become intensely focused as they travel through the device. Contour plots for both nonlinear voltage sequences show electric field lines that increasingly curve inwards as a function of distance, resulting in spatial ion focusing. Experimental ion current and spot size measurements were performed at AP using a 10-cm stacked ring ion guide and a segmented Faraday cup detector. Quadratic sequences produced ~5% smaller spot sizes (~22.8 mm) and ~25% higher ion current compared to a linear voltage sequence (~24.0 mm). Alternatively, power sequences produced ~64% smaller spot sizes (~8.7 mm), albeit with ~10x lower ion current. However, both nonlinear voltage sequences produced similar ion currents at the center of the Faraday cup detector, indicating that higher ion densities are achieved when using nonlinear voltage gradients. These results demonstrate a new way to focus ions at AP, and the capabilities demonstrated here provide fundamental insights on how to keep ions inside analytical devices at elevated pressures without RF.

47 OTHER INSTRUMENTATION↗

Stable cycling of high-voltage lithium metal batteries in ether electrolytes

The development of functional electrolytes that are stable with both the lithium (Li) anode and the 4-V cathode is of significant importance to enable long-term cycling stability of high-voltage Li metal batteries. Due to their limited oxidative stability (< 4 V), ethers have been excluded from being used in high-voltage batteries for a long time, in spite of their superior reductive stability against Li metal compared to the conventional organic carbonate electrolytes. Here we report a concentrated dual-salt/ether electrolyte design that can form stable interfacial layers on both the high-voltage LiNi1/3Mn1/3Co1/3O2 cathode and the Li metal anode, thus realizing an unprecedented capacity retention >90% over 300 cycles with a charge cut-off voltage of 4.3 V. This study offers a promising approach to enabling ether electrolytes for high-voltage applications, expanding a new spectrum of solvent choices for high-voltage Li metal batteries.

Ether electrolyte, high concentration, high voltag↗

Voltage-controlled spin–orbit torque switching in W/CoFeB/MgO

Voltage control of magnetism and spintronics have been highly desirable but rarely realized. In this work, we show voltage-controlled spin–orbit torque (SOT) switching in W/CoFeB/MgO films with perpendicular magnetic anisotropy (PMA) with voltage administered through SrTiO 3 with a high dielectric constant. We show that a DC voltage can significantly lower PMA by 45%, reduce switching current by 23%, and increase the damping-like torque as revealed by the first- and second-harmonic measurements. These are characteristics that are prerequisites for voltage-controlled and voltage-select SOT switching spintronic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗