Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transducers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Update on the Investigation of Commercial Drying Cycles Using the Advanced Drying Cycle Simulator

The purpose of this report is to document updates on the apparatus to simulate commercial vacuum drying procedures at the Nuclear Energy Work Complex at Sandia National Laboratories. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system during subsequent storage and disposal. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates well-designed investigations of drying process efficacy and water retention. Scaled tests that incorporate relevant physics and well-controlled boundary conditions are essential to provide insight and guidance to the simulation of prototypic systems undergoing drying processes. This report documents a new test apparatus, the Advanced Drying Cycle Simulator (ADCS). This apparatus was built to simulate commercial drying procedures and quantify the amount of residual water remaining in a pressurized water reactor (PWR) fuel assembly after drying. The ADCS was constructed with a prototypic 17×17 PWR fuel skeleton and waterproof heater rods to simulate decay heat. These waterproof heaters are the next generation design to heater rods developed and tested at Sandia National Laboratories in FY20. This report describes the ADCS vessel build that was completed late in FY22, including the receipt of the prototypic length waterproof heater rods and construction of the fuel basket and the pressure vessel components. In addition, installations of thermocouples, emissivity coupons, pressure and vacuum lines, pressure transducers, and electrical connections were completed. Preliminary power functionality testing was conducted to demonstrate the capabilities of the ADCS. In FY23, a test plan for the ADCS will be developed to implement a drying procedure based on measurements from the process used for the High Burnup Demonstration Project. While applying power to the simulated fuel rods, this procedure is expected to consist of filling the ADCS vessel with water, draining the water with applied pressure and multiple helium blowdowns, evacuating additional water with a vacuum drying sequence at successively lower pressures, and backfilling the vessel with helium. Additional investigations are expected to feature failed fuel rod simulators with engineered cladding defects and guide tubes with obstructed dashpots to challenge the drying system with multiple water retention sites.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Material Characterization of Grade 91 Steel Welds using, Micro-resolution Ultrasonic Imaging System

Grade 91 (9Cr-1Mo-V) steel is a common structural material for fossil-fuel fired and nuclear power plants because of its creep strength and oxidation resistance at high temperatures. In this research, we studied the feasibility of correlating the high-resolution images obtained from the immersion ultrasonic imaging technique to microstructure regions in Grade 91 steel plate weldments. The high-resolution ultrasonic images presented in this paper were generated using a 20-MHz focused transducer as the transmitter, and a laser vibrometer as the receiver in the through transmission configuration to produce longitudinal and shear waves. This nondestructive evaluation (NDE) method was used to identify the Fusion Zone (FZ), Heat-Affected Zone (HAZ), and Base Metal (BM) regions of Grade 91 cold metal transfer (CMT) and flux core arc welds (FCAW). The ultrasonic imaging results were analyzed using beam propagation amplitudes and homogeneity, which in turn were used to relate the different microstructure regions of the FCAW and CMT welded samples. With this study, we were able to identify highly susceptible microstructures in the weld that could potentially promote creep type failures.

20 FOSSIL-FUELED POWER PLANTS↗

Maturation of Rhodobacter capsulatus Multicopper Oxidase CutO Depends on the CopA Copper Efflux Pathway and Requires the cutF Product (Final Report)

The goal is to achieve a comprehensive understanding of the nature, mechanism of function and biogenesis of c-type cytochromes and their oligomeric complexes. These cytochrome are ubiquitous heme proteins that are required for cellular bioenergetics, including photosynthesis (Ps) and respiration (Res), which are central to chemical energy (ATP) production by oxidative- and photophosphorylation. We contribute to the molecular characterization of individual and membrane-integral cytochromes as parts of Ps and Res electron transport (ET) pathways, using the facultative phototrophic bacteria of as excellent models for multidisciplinary investigations. Supported by this grant we discovered novel membrane-bound cytochromes and cyts c complexes that are important for Ps- and Res-ET. We worked out their biogenesis including maturation (covalent heme addition) and assembly of mature subunits into complexes. These involve fundamental process found virtually in all organisms and are fundamental processes with major significance to the “Photosynthetic Systems” program of DOE-BES, because the cytochromes are integral components of natural energy production systems. Elucidation of basic principles, and the knowledge gained by their study greatly impact on our ability to design, engineer, and create new natural, bio-hybrid, bio-inspired and artificial systems to better capture light, transduce and store its energy with improved efficacy and are of broad significance.

14 SOLAR ENERGY↗

Acoustic Travel-Time Tomography for Wind Energy

New remote sensing technologies for direct observation of the atmospheric flow in the proximity of operating wind turbines are necessary for the advancement of wind turbine design, wind plant control, and the validation of high-fidelity numerical models; fundamental goals of the DOE Wind Energy Technology Office's (WETO's) A2e program. Modern remote sensing technologies for commercial and research applications rely on the backscatter of light or sound waves, which limits spatial and temporal resolution and cannot produce reliable flow estimates near solid bodies or reflective surfaces. Acoustic tomography (AT) is an innovative sensing technology based on fundamental thermodynamic properties of the atmosphere and an inverse algorithm that can reconstruct both velocity and temperature fields within a network of acoustic transducers. AT relies on the direct travel path of acoustic signals between speakers and microphones in the network and can achieve much higher resolutions than conventional backscatter technologies. For wind energy R&D applications, AT represents an extremely economical option over other remote sensing technologies, integrating mature and commonly available acoustic and signal processing hardware. This report is intended as an update on the development of the AT array on the NREL Flatirons Campus (FC) and includes a brief review of the instrumentation, the calibration of equipment, signal processing, and resulting flow field estimates. Designs for future AT systems and applications are detailed in this report, including summaries of new capabilities, engineering and theoretical challenges, and anticipated costs help to outline future directions for AT technology R\&D. The potential for application of AT to utility-scale turbines is also discussed. Investing in the development of the proposed instrument will establish AT as a transformational RS technique that represents a significant advance in measurement instrumentation, enabling new fundamental insights into the structure of the atmospheric boundary layer and supporting applications for wind energy, pollution transport, and resource characterization. AT is also an extremely economical option over other RS instruments, integrating mature and commonly available acoustic and signal processing hardware.

17 WIND ENERGY↗

Silicon Tetrafluoride Vapor Pressure Study

The vapor pressure (VP) of silicon tetrafluoride (SiF4) was evaluated using three different cryogenic cold baths and multiple pressure transducers (PTs). Through this experiment, the known range of VP has been extended to a low temperature of 122 K. A functional relationship for the VP has been developed for the range between 122 and 159.6 K. This relationship was also used to estimate a VP value at 88 K, which was below observable levels with a 0.1 torr gauge.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surface Acoustic Wave Sensors for Refrigerant Leak Detection: Compact, Inexpensive, Selective and Sensitive Sensors

Pacific Northwest National Laboratory (PNNL), in collaboration with Parker and Hannifin, is developing a compact, inexpensive, and highly sensitive and selective surface acoustic wave sensor coated with fluorophillic sorbent for detecting fluorocarbon leaks from HVAC systems. Having a highly effective sorbent sensitive to fluorocarbon refrigerant vapors provides a means to develop a sensing device for leak detection. Surface acoustic wave (SAW) sensors with a gas sensing film deposited between the delay lines or on the interdigital transducer have been used to detect gas and vapor molecules in harsh environments with high sensitivity. As part of this project, PNNL screened several sorbent materials that are shown to be selective towards fluorocarbon refrigerant (R32) molecule. The identified sorbent materials were synthesized, characterized, and tested towards R32 using various spectroscopic technique. Next, the sorbent material was coated on a SAW sensor as a thin film using vapor deposition and drop coating methods. The coated thin film was further characterized and tested towards the detection of pure R32 and R32 in ambient air at room temperature to demonstrate the SAW response towards R32 in presence of other competing gases and vapors in air.

42 ENGINEERING↗

Ultrasonic Measurements of Temperature Profile and Heat Fluxes in Coal-Fired Power Plants (Final Report)

Many industrial processes are inaccessible or inhospitable to characterization by traditional temperature measurement methods, such as thermocouples, especially over prolonged exposure to harsh environments. Ultrasound is an established characterization technology with diverse applications ranging from medical imaging to therapies to flaw detection to nondestructive evaluation. Ultrasound may characterize solid materials and components noninvasively as a nondestructive evaluation modality and obtain internal measurements of material properties. For example, the speed of ultrasound propagation changes with Young’s modulus and Poisson’s ratio, which can be found from its measurements. Traditional ultrasonic characterization assumes all material properties remain constant with the position. When this assumption holds, a property of interest may be measured by relating it to the speed of ultrasound propagation (or a speed of sound, SOS) and measuring the SOS by timing the ultrasound propagation through a known distance. However, when a property of interest is spatially distributed, the propagation time depends on the SOS changing with the position along the ultrasound propagation path. The multiple temperature distributions may lead to an identical time of flight (TOF). Temperature is one property that impacts the speed of ultrasound and often cannot be assumed to remain constant with the position. Previously, in the context of temperature, we addressed the challenge of ultrasonic characterization of spatially distributed properties by developing a method for measuring segmental temperature distributions (MSTD). This method divides the ultrasonic propagation into segments bound by echogenic features. These features provide ultrasonic interfaces where some energy is reflected toward the receiving transducer, and the rest continues through the medium. The time-of-flight between the echoes reflected from echogenic features characterizes the spatial distribution in the properties of interest in the corresponding segment of the ultrasonic propagation path. This project demonstrated the application of the MSTD method in industrial conditions of the coal-fired power plant. We implemented the MSTD using metals and alloys waveguides, which may be the existing structure for which the temperature distribution is characterized or purposefully designed waveguides added to the structure by welding or other means specifically to quantify thermal properties using the MSTD method. Previous iterations of the MSTD method used ceramic and cementitious waveguides, which significantly attenuate ultrasound. On the other hand, low attenuation in metallic waveguides creates interactions between echogenic features which compilates the signal analysis in the segmental TOF measurements. We have established the WG design principles that minimize the interferences between trailing and primary echoes and, in some cases, eliminate them. The waveguides in which echoes do not interfere improve the timing accuracy and the robustness of ultrasonic measurements of the spatial distributions in material properties. Our emphasis remained on the estimation of the temperature distributions. We have developed general recommendations for designing ultrasonically segmented waveguides with the reduced influence of trailing echoes. Two of our waveguide designs were tested in the industry. The first waveguide was designed for insertion into a combustion zone of the utility-scale coal-fired power plant boiler. The second design allows the characterization of temperature distribution in the direction normal to the boiler’s water wall, a large heat exchanger converting the chemical energy released during combustion to the steam driving the electrical power generation turbines. These waveguides were designed to operate within a restrictive space of thermally insulated water wall and incorporate densely located echogenic features while combatting the influence of trailing echoes. The project has successfully demonstrated the feasibility of using the developed method for accurate, continuous, and robust temperature measurements in extreme environments of power generation and other industrial processes. It, therefore, has achieved its overarching goal of advancing the technology readiness level of the novel Ultrasound Measurements of Segmental Temperature Distribution (US-MSTD) method for real-time measurements of the temperature distribution and heat fluxes closer to commercial availability, developing a prototype multipoint measurement system, and validating its performance on coal-fired utility boilers. The success of this project was achieved in collaboration with the power generator, Rocky Mountain Power, and set the stage for the transfer of this technology from the laboratory to the industry.

01 COAL, LIGNITE, AND PEAT↗

Moore Machine Motion Controls Refurbishment Statement of Work and Specification

Diamond Turning Machines known as “Moore” machines are used in the production of Potassium diHydrogen Phosphate (KDP) optics required for the National Ignition Facility (NIF). These machines are owned by the Department of Energy, as provided by Lawrence Livermore National Security LLC (LLNS). Moore Machines 1 and 2 are located at the Gooch & Housego (G&H) facility in Highland Heights, OH. The existing Aerotech motion controllers, motor drivers/amplifiers, input/output (I/O) hardware, control computer, software user interface, human machine interface (HMI), cabling, and encoders are beyond service life and require replacement. This Statement of Work (SoW) defines the motion control system refurbishment requirements for the Moore diamond turning machines designated Moore 1 and Moore 2. The motion controls system design shall include a motion control computer, control software, motor drive amplifiers and controllers, linear scale encoders, rotary encoders, HMI, power distribution, emergency stop (E-Stop) and interlocks, cabling, switches, solenoids, transducers, sensors, actuators, ancillary system interfaces, and related components necessary for a complete machine tool control system. The Subcontractor shall include effort to standardize systems between the two machines if reasonably possible.

42 ENGINEERING↗

A Review: PFAS Adsorption, Sensing, and Remediation with Engineered Nanoporous Materials

Per- and polyfluoroalkyl substances (PFAS) are among the most abundant environmental contaminant species. They are widespread due to uncontrolled industrial and commercial use and have been linked to health risks such as cancer. With rising global concerns about the public health effects of PFAS, there is an incentive to develop strategies for reliable monitoring and effective PFAS removal, particularly in drinking water. Traditional PFAS sensing techniques are inefficient due to long measurement times, high labor input, high costs, and limitations to ex situ analysis. Current commercially available sorbents for PFAS removal generally lack the ability to capture PFAS components rapidly and quantitatively. Furthermore, existing sorbents are notably inefficient in removing the more toxic, smaller PFAS chemical chains. Large-scale applications of these methods tend to be costly and resource-intensive. Pacific Northwest National Laboratory has developed unique strategies for PFAS sensing and removal with capture probe technology that has an affinity for fluorocarbons, including PFAS. For both sensing and removal, the customizable capture probes can target specific PFAS compounds since they used a metal-organic framework (MOF)-based technology that can be fine-tuned and molecularly tailored. This tailoring of the materials enables high PFAS sensitivity, selectivity, and faster uptake. PNNL’s capture probe materials have been developed into a sensing technique based on the interactions of the capture probes with PFAS at the molecular level and further transduced that to a quantifiable electrochemical response. The materials have been integrated into a sensor platform developed by New Jersey Institute of Technology (NJIT). Tunable capture probes with a range of detection sensitivities allow for faster and more sensitive PFAS detection limits as low as what appears to be 0.5 ng/L (compared to the U.S. Environmental Protection Agency health advisory level of 70 ng/L). Customization of the capture probe results in improved sorption capacities (fast kinetics and high capacities) compared to commercial granular activated carbons. This research applied various experimental and modeling tools to improve understanding the molecular level interactions between the sorbents towards PFAS adsorption properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Studying light–matter interactions and energy transfer at the nanoscale with a trapped–ion quantum computer

A grand challenge in materials sciences is to control energy transduction, transfer and dissipation at the nanoscale. Meeting this challenge requires progress in nanoscale fabrication and synthesis, but equally importantly, also progress in our understanding of how nanoscale structure influences these phenomena. Although detailed quantum mechanical models exist that capture the structure and physics of materials and molecular species, solving these models to calculate the relevant emergent phenomena, which often occur over vastly different time and energy scales, has so far proven difficult. In this project, we studied how to model energy transfer and light-matter interactions using trapped-ion quantum computers. Our studies focused on emulation of critical processes in natural systems, such as the well-known photosynthetic pigment-protein complexes responsible for capturing and transducing light to electrons. In addition, we implemented proof-of-principle experiments demonstrating that such calculations are possible on trapped-ion quantum computing hardware. These studies and experiments pave the way to investigate energy transport and transduction in a detail not accessible with classical computing technologies. We expect that our studies will allow to extract important guiding principles on how to improve the efficiency of nano-scale light-harvesting and transduction devices.

36 MATERIALS SCIENCE↗

FRET Based Biosensors for CBRN Threat Detection

Biosensors are devices used to detect the presence/concentration of a biological analyte. Biosensors consist of three parts: 1) a component that recognizes the analyte and produces a signal, 2) a signal transducer, and 3) a reader device. A multiplexed biosensor combines different biosensors for increased detection capabilities.

Demers, Steven M.↗

Excerpt from Oxygen Monitor Clean Testing Report Performed in 2010

The Rosemount X-STREAM Series X2GP is a paramagnetic oxygen analyzer with a 0-25% oxygen measurement range. It claims a drift less than 2% of span (0.10% volume oxygen) per week, and a response time of less than 5 seconds (for the analyzer to report 90% of a step change). Our test equipment was set-up such that the same gas was running through each oxygen analyzer at the same time. This allowed Calibration Error, Calibration Drift, and Loss of Power Testing to be run on all monitors at the same time, eliminating any variability between the analyzers from tolerances in the gas cylinder, ambient temperature, ambient pressure, test duration, etc. An APTech pressure regulator was placed on the gas cylinder manifold and a 23 psia Paroscientific pressure transducer measured the regulator’s outlet pressure. This did not give the inlet pressure on any one analyzer but outlet pressure from the manifold before the stream was split. The APTech pressure regulator was used to keep operating conditions consistent. A DWYER rotameter was installed on each oxygen monitor’s outlet piping. With the exception of Variation of Flow Rate Testing, the rotameter was left fully open for all testing. The flow rate through each oxygen monitor was controlled by a Swagelok needle valve that was installed on each analyzer’s inlet piping. Additionally, a filter was installed in the each monitor’s inlet piping to keep particles from the measurement cells and a Swagelok ball valve was installed on each monitor’s outlet piping to isolate each monitor between tests. No pumps were installed. Each of the cylinders used was at a pressure greater than ambient room barometric pressure. This pressure differential was used to move gas through the testing equipment. The flow rate through each analyzer was controlled by the Swagelok needle valve installed on each analyzer’s inlet piping. Finally, for all tests, a Paroscientific Digiquartz Barometer was used to measure ambient room barometric pressure and a Fluke Thermo-hygrometer was used to measure ambient room temperature.

47 OTHER INSTRUMENTATION↗

Thiol-based pathways in the thylakoid lumen and their role in photoprotection

The long-term goal of this research is to elaborate the catalysis of thiol-disulfide transactions in the thylakoid lumen, a compartment required for transducing energy via photophosphorylation. The molecular identity of the redox players catalyzing thiol-disulfide exchanges, their relevant targets of action in vivo and how thiol-disulfide chemistry in general controls photosynthesis are the experimental questions this research aims to address. Through previous work, we documented the requirement of catalyzed disulfide formation and reduction for the biogenesis of two photosynthetic enzymes, namely Photosystem II and the cytochrome b6f complex. We established that dedicated trans-thylakoid pathways operate in these processes by delivering reducing and oxidizing power to cysteine-containing subunits of the photosynthetic complexes, which are localized in the lumen compartment. Here we focused on CCDA, CCS4 and CCS5/HCF164, the components of the disulfide-reducing pathway which maintains the heme binding cysteines of apoforms of plastid cytochrome c in the reduced form prior to covalent heme ligation. We showed that CCS4 and CCS5 operate in functionally redundant pathways for the supply of reducing power and postulate a role for CCS4 in recruiting the source of reductants to CCDA or controlling the CCDA-dependent transduction of reducing equivalents. We also demonstrate the disulfide reducing pathway operates to counter thiol oxidation of the heme-binding cysteines by disulfide forming enzyme LTO1 in the thylakoid lumen.

59 BASIC BIOLOGICAL SCIENCES↗

Measuring thermal profiles in high explosives using neural networks

We present a new method for calculating the temperature profile of high explosive (HE) material using a Convolutional Neural Network (CNN). To train/test the CNN, we have developed a hybrid experiment/simulation method for collecting acoustic and temperature data. We experimentally heat cylindrical containers of HE material until detonation/deflagration, where we continuously measure the acoustic bursts through the HE using multiple acoustic transducers lined around the exterior container circumference. However, measuring the temperature profile in the HE in an experiment would require inserting a large number of thermal probes, which would disrupt the heating process. Thus, we use two thermal probes, one at the HE center and one at the wall. We then use numerical simulation of the heating process to calculate the temperature distribution and correct the simulated temperatures based on the experimental center and wall temperatures. We calculate temperature errors on the order of 15 °C, which is ~12% of the range of temperatures in the experiment. We also investigate how the algorithm’s accuracy is affected by the number of acoustic receivers used to collect each measurement and the resolution of the temperature prediction. This work provides a means of assessing the safety status of HE material, which cannot be achieved using existing temperature measurement methods. In addition, it has implications for a range of other applications where internal temperature profile measurements would provide critical information. These applications include detecting chemical reactions, observing thermodynamic processes such as combustion, monitoring metal or plastic casting, determining the energy density in thermal storage capsules, and identifying abnormal battery operations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantification of Residual Water in Spent Fuel Dry Storage Canisters Using Mass Spectrometry

The purpose of this report is to document updates on the apparatus to simulate commercial vacuum drying procedures at the Nuclear Energy Work Complex at Sandia National Laboratories. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system during subsequent storage and disposal, such as fuel degradation; cladding corrosion, embrittlement, or breaching; and the creation of a flammable environment via radiolysis of water. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates well-designed investigations of drying process efficacy and water retention. Scaled tests that incorporate relevant physics and well-controlled boundary conditions are essential to provide insight and guidance to the simulation of prototypic systems undergoing drying processes. This report documents details on the quantification of residual water in the Advanced Drying Cycle Simulator (ADCS), an apparatus built to simulate commercial drying procedures and quantify the amount of residual water remaining in a pressurized water reactor (PWR) fuel assembly after drying. The ADCS was constructed with a prototypic 17×17 PWR fuel skeleton and waterproof heater rods to simulate decay heat. The ADCS is outfitted with thermocouples to measure the thermal response of the ADCS to simulated decay heats and internal helium fill pressures relevant to commercial drying procedures. The ADCS is also instrumented with pressure transducers to measure the pressures and vacuum levels observed during simulated commercial drying. The most unique instrumentation used for quantifying residual water in the ADCS is a Hiden Analytical HPR-30 mass spectrometer (MS), which measures gas compositions of the ADCS internal free volume, based on partial pressures calculated from relative proportions of gas molecules detected by the MS. This report details the methodology used to implement MS measurements in quantifying residual water in the ADCS. This methodology includes the calibration of the HPR-30 MS to a Buck Research Instruments CR-4 chilled mirror hygrometer, which itself is calibrated to a NIST-traceable standard. Data collected by both the MS and the chilled mirror hygrometer from water/helium mixtures ranging from 150 to 500,000 ppmv water in helium were used to generate calibration curves, establishing a source of verification of MS measured water contents. Details regarding water content measurement uncertainties are included in this report, defining the accuracy and verifiability of the HPR-30 MS in measuring residual water content in simulated dry storage canister environments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Blue Canyon Dome: Development of a Small-Scale Testbed for Monitoring Underground Explosions

This report documents the development of the Blue Canyon Dome (BCD) testbed, including test site selection, development, instrumentation, and logistical considerations. The BCD testbed was designed for small-scale explosive tests (~5 kg TNT equivalence maximum) for the purpose of comparing diagnostic signals from different types of explosives, the assumption being that different chemical explosives would generate different signatures on geophysical and other monitoring tools. The BCD testbed is located at the Energetic Materials Research and Testing Center near Socorro, New Mexico. Instrumentation includes an electrical resistivity tomography array, geophones, distributed acoustic sensing, gas samplers, distributed temperature sensing, pressure transducers, and high-speed cameras. This SAND report is a reference for BCD testbed development that can be cited in future publications.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Temperature and Pressure Instrumentation for LYNM PE1 Chemical Explosive Testing

Underground chemical explosive testing has been conducted at the Nevada National Security Site under the Physics Experiment 1 (PE1) to validate explosive computer modeling and, ultimately, improve the accuracy of subsurface explosive detection. This SAND Report describes the dynamic temperature and pressure measurements within the chamber induced by the chemical explosive for the first of three experiments, PE1-A. The report details the instrumentation used for the experiment, the emplacement of the hardware, and the measured results. Dynamic temperature measurements were accomplished with the use of optical spectrometers and dynamic pressure was measured with a series of high-rated pressure transducers. This report includes details of the design and results of four cavity sensor systems used to measure early-time temperature, early-time pressure, late-time temperature, and late time pressure. The outcomes of PE1-A were used to inform the design of the remaining PE1 series experiments, PE1-B and PE1-DL.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗