Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transducers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Thin film strain transducer

A strain transducer system and process for making same is disclosed wherein a beryllium-copper ring having four strain gages disposed thereon is electrically connected in Wheatstone bridge fashion to output instrumentation. Tabs are bonded to a balloon or like surface with strain on the surface causing bending of the ring and providing an electrical signal through the gages proportional to the surface strain. A figure is provided which illustrates a pattern of a one-half ring segment as placed on a sheet of beryllium-copper for chem-mill etch formation, prior to bending and welding of a pair of the segments to form a ring structure.

Rand, J. L.↗

Broadband Ultrasonic Transducers

New geometry spreads out resonance region of piezoelectric crystal. In new transducer, crystal surfaces made nonparallel. One surface planar; other, concave. Geometry designed to produce nearly uniform response over a predetermined band of frequencies and to attenuate strongly frequencies outside band. Greater bandwidth improves accuracy of sonar and ultrasonic imaging equipment.

Heyser, R. C.↗

Acoustic Levitation With One Transducer

Higher resonator modes enables simplification of equipment. Experimental acoustic levitator for high-temperature containerless processing has round cylindrical levitation chamber and only one acoustic transducer. Stable levitation of solid particle or liquid drop achieved by exciting sound in chamber to higher-order resonant mode that makes potential well for levitated particle or drop at some point within chamber.

Barmatz, Martin B.↗

In-flight measurement of ice growth on an airfoil using an array of ultrasonic transducers

Results from three research flights to obtain in-flight ultrasonic pulse-echo measurements of airfoil ice thickness as a function of time using an array of eight ultrasonic transducers mounted flush with the leading edge of the airfoil are presented. The accuracy of the thickness measurements is found to be within 0.5 mm of mechanical and stereophotograph measurements of the ice accretion. The ultrasonic measurements demonstrate that the ice growth rate typically varies during the flight, with variations in the ice growth rate for dry ice growth being primarily due to fluctuations in the cloud liquid water content. Discrepancies between experimental results and results predicted by an analytic icing code underline the need for a better understanding of the physics of wet ice growth.

Hansman, R. John, Jr.↗

In-flight measurement of ice growth on an airfoil using an array of ultrasonic transducers

Results of preliminary tests to measure ice growth on an airfoil during flight icing conditions are presented. Ultrasonic pulse echo measurements of ice thickness are obtained from an array of eight ultrasonic transducers mounted flush with the leading edge of the airfoil. These thickness measurements are used to document the evolution of the ice shape during the encounter in the form of successive ice profiles. Results from 3 research flights are presented and discussed. The accuracy of the ultrasonic measurements is found to be within 0.5 mm of mechanical and stereo photograph measurements of the ice accretion.

Hansman, R. John, Jr.↗

Shock tube investigation of dynamic response of pressure transducers for validation of rotor performance measurements

For some time now, NASA has had a program under way to aid in the validation of rotor performance and acoustics codes associated with the UH-60 rotary-wing aircraft; and to correlate results of such studies with those obtained from investigations of other selected aircraft rotor performance. A central feature of these studies concerns the dynamic measurement of surface pressure at various locations up to frequencies of 25 KHz. For this purpose, fast-response gauges of the Kulite type are employed. The latter need to be buried in the rotor; they record surface pressures which are transmitted by a pipette connected to the gauge. The other end of the pipette is cut flush with the surface. In certain locations, the pipette configuration includes a rather sharp right-angle bend. The natural question has arisen in this connection: In what way are the pipettes modifying the signals received at the rotor surface and subsequently transmitted to the sensitive Kulite transducer element. The basic details and results of the program performed and recently completed in the High Pressure Shock Tube Laboratory of the Department of Aeronautics and Astronautics at Stanford University are given.

Bershader, Daniel↗

Low power consumption current transducer

A low power consumption current transducer utilizes a saturable core reactor which includes a pair of opposed gate windings and a control winding. The control winding of the saturable reactor is arranged to receive the current to be measured. A square wave generator is connected to the gate winding of the transformer connected across the square wave generator and the secondary connected in series with the gate windings of the reactor. A full wave rectifier is connected to the gate windings and a resistor is connected across the rectifier to provide a DC voltage to cross it representative of the current flow through the control winding. A DC power supply is provided to supply power to the square wave voltage source. A diode is connected between each end of the primary winding of the transformer and one polarity of the DC power supply to commutate the reactive current resulting from the counter emf generated in the reactor back to the DC supply to eliminate potentially damaging reactive voltage spikes which would otherwise appear at the output of the square wave generator and conserve energy.

W T McLyman↗

A free-trailing vane flow direction indicator employing a linear output Hall effect transducer

The Hall effect vane (HEV) was developed to measure flow angularity in the NASA 40-by-80-foot and 80-by-120-foot wind tunnels. This indicator is capable of sensing flow direction at air speeds from 5 to 300 knots and over a + or - 40 deg angle range with a resolution of 0.1 deg. A free-trailing vane configuration employing a linear output Hall effect transducer as a shaft angle resolver was used. The current configuration of the HEV is designed primarily for wind tunnel calibration testing; however, other potential applications include atmospheric, flight or ground research testing. The HEV met initial design requirements.

Zell, Peter T.↗

Liquid-membrane coupling response of submersible electrostatic acoustic transducer

A mathematical model was developed for the liquid-membrane coupling response of the submersible electrostatic acoustic transducer (ESAT) described by Cantrell et al. (1979). The model accounts for the ESAT's rolloff response and predicts the essential features of the ESAT frequency response. Model predictions were found to agree well with measurements taken over the frequency range from 1 to 11 MHz.

Cantrell, John H.↗

Improved Ultrasonic Transducer For Measuring Cryogenic Flow

Improved ultrasonic transducer used to measure flow of cryogenic fluid. Includes wedge made nonintrusive by machining it out of bulk material of duct carrying fluid. Skewed surfaces of wedge suppress standing waves, thus reducing ringing and increasing signal-to-noise ratio. Increases accuracy of measurements of times of arrival of ultrasonic pulses, from which times flow inferred.

Barkhoudarian, Sarkis↗

Sparsely Sampled Phase-Insensitive Ultrasonic Transducer Arrays

Three methods of interpretation of outputs from sparsely sampled two-dimensional array of receiving ultrasonic transducers used in transmission experiments investigated. Methods are: description of sampled beam in terms of first few spatial moments of sampled distribution of energy; use of signal-dependent cutoff to limit extent of effective receiver aperture; and use of spatial interpolation to increase apparent density of sampling during computation. Methods reduce errors in computations of shapes of ultrasonic beams.

Patrick H. Johnston↗

Absolute ultrasonic displacement amplitude measurements with a submersible electrostatic acoustic transducer

An experimental technique for absolute measurement of ultrasonic wave particle displacement amplitudes in liquids is reported. The technique is capable of measurements over a frequency range of two decades with a sensitivity less than one angstrom. The technique utilizes a previously reported submersible electrostatic acoustic transducer (ESAT) featuring a conductive membrane stretched over a recessed electrode. An uncertainty analysis shows that the displacement amplitude of an ultrasonic plane wave incident on the ESAT can be experimentally determined to better than 2.3-4 percent, depending on frequency, in the frequency range of 0.5-15 MHz. Membranes with lower and more uniform areal densities can improve the accuracy and extend the operation to higher frequencies.

Yost, William T.↗

Elongation Transducer For Tensile Tests

Extensometer transducer measures elongation of tensile-test specimen with negligible distortion of test results. Used in stress-versus-strain tests of small specimens of composite materials. Clamping stress distributed more evenly. Specimen clamped gently between jaw and facing surface of housing. Friction force of load points on conical tips onto specimen depends on compression of spring, adjusted by turning cover on housing. Limp, light nylon-insulated electrical leads impose minimal extraneous loads on measuring elements.

Roberts, Paul W.↗

Improved Micromachined Transducers

Sensor systems of proposed type incorporate micromachined silicon-based structures as electrostatic force and displacement actuators and micromachined quantum-mechanical-tunneling electrodes as one form of displacement transducers, along with electronic circuits providing multiple electrical stimuli to displacement electrodes for measurement, calibration, monitoring of sensor status, and adjustment. Concept applicable to accelerometers, seismometers, geophones, magnetometers, pressure gauges, and other sensors in which phenomena of interest measured in terms of forces on, and/or displacements of, structural components. Provides completely remote measurement, control, health monitoring, treatment, and like, using telemetry commands.

Hartley, Frank T.↗

Broadband, High-Temperature Ultrasonic Transducer

Materials chosen for endurance at high temperatures and acoustic coupling and damping. Acoustic transducer designed to exhibit broad frequency response and to survive temperatures close to melting points of brazing alloys. Attached directly and continuously to hot object monitored ultrasonically: for example, it can be attached to relatively cool spot on workpiece during brazing for taking ultrasonic quality-control measurements.

Parker, F. Raymond↗

Instrument For Simulation Of Piezoelectric Transducers

Electronic instrument designed to simulate dynamic output of integrated-circuit piezoelectric acceleration or pressure transducer. Operates in conjunction with external signal-conditioning circuit, generating square-wave signal of known amplitude for use in calibrating signal-conditioning circuit. Instrument also useful as special-purpose square-wave generator in other applications.

Mcnichol, Randal S.↗

Single Transducer Ultrasonic Imaging Method that Eliminates the Effect of Plate Thickness Variation in the Image

This article describes a single transducer ultrasonic imaging method that eliminates the effect of plate thickness variation in the image. The method thus isolates ultrasonic variations due to material microstructure. The use of this method can result in significant cost savings because the ultrasonic image can be interpreted correctly without the need for machining to achieve precise thickness uniformity during nondestructive evaluations of material development. The method is based on measurement of ultrasonic velocity. Images obtained using the thickness-independent methodology are compared with conventional velocity and c-scan echo peak amplitude images for monolithic ceramic (silicon nitride), metal matrix composite and polymer matrix composite materials. It was found that the thickness-independent ultrasonic images reveal and quantify correctly areas of global microstructural (pore and fiber volume fraction) variation due to the elimination of thickness effects. The thickness-independent ultrasonic imaging method described in this article is currently being commercialized under a cooperative agreement between NASA Lewis Research Center and Sonix, Inc.

Roth, Don J.↗

The Evolution of Energy-Transducing Systems. Studies with Archaebacteria

The dicyclohexyl carbodiimide (DCCD)- binding site of the membrane ATPase from Halobacterium saccharovorum was investigated during earlier periods of this Cooperative Agreement and was localized to a cyanogen bromide fragment of subunit 2 from amino acids 379 (Glu) to 442 (Met). Although the exact position of the reactive amino acid (probably a glutamic acid) has not yet been determined, the data, together with recently obtained immuno reactions and sequences of Cyanogen Bromide (CNBr) fragments from E.coli F-ATPase, suggested subunit interactions in the halobacterial ATPase which had not been recognized before. They also provided evidence for the presence of a gamma subunit in the halobacterial ATPase, and for a stretch of a amino acids similar to the 'catch' between beta and gamma in bovine F-ATPase. The evolutionary implications of these findings are twofold: first, halobacterial (or archaebacterial) ATPases appear as complex as those from higher organisms - no simpler versions of these membrane enzymes are known to date; second, a monophyletic origin of the energy-transducing ATPases is becoming more apparent, and - together with other data - the split into V- and F-ATPases may have occurred much later than had been previously thought (i.e., after the split into Archaea and Bacteria). Other work included the characterization of an extremely halophilic isolate (Halococcus salifodinae ) from Permian salt sediments. This organism appeared to be an autotrophic halobacterium; its incorporation of C02 was investigated.

Stan-Lotter, Helga↗