Endurance test of helium circulator for HTR-PM - 18531

High-temperature Gas-cooled Reactor Pebble-bed Module (HTR-PM) will be built as the world's first pebble-bed type modular HTGR commercial demonstration plant according to Chinese National science and technology program. HTR-PM will be expected to begin generating electricity in the end of 2017 in Shidao bay of China. Helium circulator is one of critical component of HTR-PM, which circulates reactor coolant through the reactor core and steam generators. The helium circulator was designed to be a vertical layout and its rotor was supported by active magnet bearings (AMBs). The whole circulator including motor and cooler was sealed in a pressure vessel. Since it is a large mechanical and electrical equipment and the design is totally advanced integrated with many new technologies, experiment study of helium circulator would be significant for safe and reliable operation of HTR-PM plant in the future. For the lack of engineering experience of this equipment, it was necessary to manufacture a prototype for tests. Meanwhile, Engineering Test Facility- Helium Circulator. ETF-HC was built in Institute of Nuclear and New Energy Technology (INET) for the tests. The prototype is completely same as the real machine for the plant. After prototype fabrication, nitrogen test was firstly conducted in the factory by the manufacturer, designer and users. After successful factory test, the prototype was delivered to INET to be tested in ETF-HC. Although nitrogen simulation test had been completed successfully, helium endurance test has been continually carried out in ETF-HC for one and half years because of several sealing problems caused by helium. After solving all kinds of problem in the field, helium circulator run continuously 50 hours under rated condition. Furthermore, 50 service cycles test was conducted in ETF-HC. More than 500 operation hours was accumulated during endurance test. Throughout the final performance test, a conclusion can be made that the helium circulator performance met the design requirements and its feasibility, availability and reliability was verified. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Inferring subsurface heterogeneity from push-drift tracer tests

In this study, we consider the late-time tailing in a tracer test performed with a push-drift methodology (i.e., quasi-radial injection followed by drift under natural gradient). Numerical simulations of such tests are performed on 1000 multi-Gaussian 2-D log-hydraulic conductivity field realizations of varying heterogeneity, each under eight distinct mean flow directions. The ensemble pdfs of solute return times are found to exhibit power law tails for each considered variance of the log-hydraulic conductivity field, σ$2\atop{ln K}$. The tail exponent is found to relate straightforwardly to σ$2\atop{ln K}$ and, within the parameter space we explored, to be independent of push-phase pumping rate, pumping duration, and local-scale dispersivity. We conjecture that individual push-drift tracer tests in wells with screened intervals much greater than the vertical correlation length of the aquifer will exhibit quasi-ergodicity and that their tail exponent may be used to infer σ$2\atop{ln K}$. Lastly, we calibrate a predictive relationship of this sort from our Monte Carlo study, and apply it to data from a push-drift test performed at a site of approximately known heterogeneity—closely matching the existing best estimate of heterogeneity.

58 GEOSCIENCES↗

Self-Lubricating Bushing Testing for John Day Dam Ka plan Turbine Replacement

The goal of this testing program is to find suitable self-lubricated alternatives to replace the in use oil lubricated grooved-bronze bushing in Kaplan runner hubs that are currently being utilized at John Day Dam operated by the U.S. Army Corps of Engineers (USACE). Scaled bushing testing utilizing a Pacific Northwest National Laboratory designed, fabricated, and operated Bushing Test Stand under the direction and funding from USACE determined that self-lubricated bushings tested appear capable of outperforming the current oil-lubricated bronze bushings. Performance tests are focused on durability which includes cyclic load bearing properties and articulations under various loading scenarios. This testing was performed at nominally 1/5 th scale. A scaling sensitivity analysis determined that scaled testing results apply to prototypic size. This report shows the direct comparison between the current baseline bronze bushing to self-lubricated bushings from various manufacturers. Bushing data like coefficient of friction and bushing material loss (associated with bushing wear) was determined. Self-lubricated bushings tested include products manufactured specifically for hydropower applications by the following companies: Trelleborg, Kamatics, Anonymous, and Tenneco/Deva.

42 ENGINEERING↗

Results of the 1000 Hour Rotary Microfilter Endurance Test

David Herman gives an overview of the 1000 Hour Rotary Microfilter Endurance Test performed at SRNL. The SpinTek Rotary Microfilter was tested with sludge washing and evaluated using performance metrics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Report on FY19 Testing in Support of Integrated EPP-SMT Design Methods Development

Experiments in support of the development of the integrated Elastic–Perfectly Plastic (EPP) analysis and Simplified Model Test (SMT) design methodology continued in FY 2019. Major progress was made in the verification of the newly developed two-bar SMT and single-bar SMT (SBSMT) methods by performing tests on Alloy 617 and SS 316H at high temperatures. Comparable results were achieved when the materials were tested under same conditions using both techniques. Because of its simple test configuration, SBSMT was the preferred testing technique used to evaluate elastic follow-up effect and generate data in support of SMT-based design curves. Evaluation of elastic follow-up was started with testing SS 316H at 815°C using SBSMT in this reporting period. As a result of this effort, the basic procedure and test protocol to provide data in support of the development of SMT-based design curves were established. This report also summarizes recent test results for the pressurization SMT using test articles with key features on Alloy 617 at intermediate strain ranges and at a low temperature of 850°C. Although more test results are needed in order to fully understand the effect of primary load on SMT creep-fatigue (CF) life, the limited test data indicate that the primary load reduced the SMT life at intermediate strain ranges and high temperatures. Recognizing the advantages of the newly developed SBSMT method, a new test geometry was designed to allow the elevation of the primary load effect on SMT CF life with the SBSMT technique. Additionally, selected tests were performed on SS 316H (heat 101076) to provide basic information about the heat of material. The tests performed included high-temperature tensile, fatigue, creep fatigue, and thermomechanical experiments. The results will be used to support the verification of the material constitutive model developed at Argonne National Laboratory.

36 MATERIALS SCIENCE↗

Cold crucible induction melter studies for making glass ceramic waste forms: A feasibility assessment

Glass ceramics are being developed to immobilize fission products, separated from used nuclear fuel by aqueous reprocessing, into a stable waste form suitable for disposal in a geological repository. This work documents the glass ceramic formulation at bench scale and for a scaled melter test performed in a pilot-scale (approximately 1/4 scale) cold crucible induction melter (CCIM). Melt viscosity, electrical conductivity, and crystallization behavior upon cooling were measured on a small set of compositions to select a formulation for melter testing. Property measurements also identified a temperature range for melter operation and cooling profiles necessary to crystallize the targeted phases in the waste form. Bench scale and melter run results successfully demonstrate the processability of the glass ceramic using the CCIM melter technology.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance and Health Test Procedure for Grid Energy Storage Systems

A test procedure to evaluate the performance and health of field installations of grid-connected battery energy storage systems (BESS) is described. Performance and health metrics captured in the procedures are: round-trip efficiency, standby losses, response time/accuracy, and useable energy/state of charge at different discharge/charge rates over the system's lifetime. The procedures are divided into reference performance tests, which require the system to be put in a test mode and are to be conducted in intervals, and real-time monitoring tests, which collect data during normal operation without interruption. The procedures can be applied on a wide array of BESS with little modification and can thus support BESS operators in the management of BESS field installations with minimal interruption and expenditure. Simulated results based on a detailed system simulation of a prototype system are provided as guideline.

25 ENERGY STORAGE↗

ASX O-ring Life Testing Using a LAW High Bound Melter Feed Simulant (Final Report)

The Hanford Tank Waste Treatment and Immobilization Plant (WTP) is planning to utilize an Isolok sampler to sample the contents of the Low Activity Waste (LAW) and High Level Waste (HLW) Melter Feed Preparation Vessels (MFPV) as well as the contents of the LAW Concentrate Receipt Vessel (CRV). Over the course of testing, it has been recognized that the long term reliability of the o-ring seals in the Isolok sampler are an important component in sampling. The Isolok sampler will be collecting samples of melter feed that contain a high percentage of highly abrasive particles which can impact the life of the o-rings. Although o-ring life in normal service is typically several hundred thousand cycles (such as in the air cylinders and other non-abrasive environments), no data are available for the life of the o-ring seals in this abrasive environment. To address this concern, a Test Exception was issued to perform testing to determine whether the o-rings in an Isolok sampler will continue to function through one year of projected HLW MFPV sampler operation, or approximately 7,000 sampler piston cycles. This final report provides results of the o-ring testing that was performed with the ASX sampler.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance and Health Test Procedure for Grid Energy Storage Systems: Preprint

A test procedure to evaluate the performance and health of field installations of grid-connected battery energy storage systems (BESS) is described. Performance and health metrics captured in the procedures are: Round-trip efficiency, Standby losses, Response time/accuracy, and Useable Energy/ State of Charge at different discharge/charge rates over the system's lifetime. The procedures are divided into Reference Performance Tests, which require the system to be put in a test mode and are to be conducted in intervals, and Real-time Monitoring tests, which collect data during normal operation without interruption. The procedures can be applied on a wide array of BESS with little modifications and can thus support BESS operators in the management of BESS field installations with minimal interruption and expenditures.can be applied on a wide array of BESS with little modifications and can thus support BESS operators in the management of BESS field installations with minimal interruption and expenditures.

25 ENERGY STORAGE↗

Test beam performance measurements for the Phase I upgrade of the CMS pixel detector

A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. Here in this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is $99.95\pm0.05\,\%$, while the intrinsic spatial resolutions are $4.80\pm0.25\,\mu \mathrm{m}$ and $7.99\pm0.21\,\mu \mathrm{m}$ along the $100\,\mu \mathrm{m}$ and $150\,\mu \mathrm{m}$ pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-High Operation Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR) enabled by additive manufacturing: Test Facility & Performance Evaluations

Solar Heat for Industrial Processes (SHIP) cavity receivers are capable of generating electricity or industrial process heat by absorbing thermal energy from solar radiation, focused on a small area. The concentration of solar radiation on the small area of the receiver enables the achievement of high temperatures (ranging from 400°C to 1,100°C) of a working fluid, thus making the SHIP technology thermodynamically comparable with conventional power plants. A volumetric receiver consists of a porous structure-generally made of silicon carbide or metal, which absorbs solar radiation and converts it into heat energy. Heat energy from the porous materials is then transferred to the fluid following through them. A volumetric receiver acts as a convective heat exchanger, transferring heat to the fluid through convection. Open-loop volumetric receivers work with air at atmospheric pressure and are suitable for single-cycle or multi-cycle energy plants. A Model Based Systems Engineering (MBSE) approach was used to develop a test bed at Sandia national Laboratories (SNL) capable of demonstrating an open-loop volumetric air receiver developed by General Electric Aerospace (GE Aerospace). This paper presents the development of the various MBSE methods, test bed, and testing operations for the GE air receiver, which was experimentally demonstrated to achieve 1,350°C for over 3 hours of operation and an approximate 70% receiver efficiency. By being able to achieve such high temperatures >1,000°C, this work provides the potential to support many SHIP industrial use cases.

14 SOLAR ENERGY↗

Passive Noise Analysis for Advanced Tamper Indication. End of Year Report 2015

Idaho National Laboratory (INL) is part of a multi-lab project assessing front-end electronics for unattended measurement (FEUM) being developed for the International Atomic Energy Agency (IAEA) unattended systems. The FEUM development activity provides an opportunity to address tampering detection between FEUM and the detector, signal integrity from FEUM to the data acquisition systems, and data validity – long-standing challenges for the IAEA. This report summarizes the INL activities in Fiscal Year (FY) 2015 to characterize and test passive noise analysis as a potential tamper-indicating approach for implementation into FEUM or as a stand-alone method. The project’s primary objectives in FY-15 were to (1) determine detectable tamper scenarios using four pre-amplifier/detector systems, (2) perform tests of tampering scenarios with three common cable types used by the IAEA, (3) separate radio-frequency-induced events from inherent effect by means of an anechoic chamber, and (4) perform tests at an industrial facility. General conclusions were reached in several areas.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Technical Requirements for Application of Operator Support Technology across Multiple Plant Systems

Argonne National Laboratory (ANL) and Idaho National Laboratory (INL) are jointly developing and evaluating operator aids to: (i) facilitate more timely response to plant faults and grid disturbances; (ii) achieve better management of plant upsets and improved operator performance; and (iii) ultimately improve nuclear plant safety, production, and cost management. The overall objective of the collaborative effort in this third and final year of the project was to conduct human performance tests using nuclear plant operators in the Human Systems Simulation Laboratory (HSSL) control room at INL to assess the value of a computerized operator support system (COSS) as an aid to the operator. This report describes the work performed by ANL. A companion report describes the work performed by INL and the results of the human performance tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Corrosion Behavior of Steels in Supercritical CO 2 for Power Cycle Applications

In order to understand issues with corrosion of heat exchanger materials in direct supercritical carbon dioxide (sCO 2 ) power cycles, a series of autoclave exposure experiments and electrochemical experiments have been conducted. Corrosion behaviors of 347H stainless steel and P91 martensitic-ferrtic steel in sCO 2 environment have been compared. In autoclave exposure tests performed at 50°C- 245°C and 80 bar. Mass change measurements, surface characterization, and corrosion product analysis have been conducted to understand the corrosion behavior of steels in sCO 2 containing H 2 O and O 2 . Electrochemical tests performed at room temperature and 50°C, a simulation environment of water condensation phase with dissolved CO 2 was prepared to evaluate the corrosion resistance of materials. From both types of experiments, generally 347H showed higher corrosion resistance than P91.

01 COAL, LIGNITE, AND PEAT↗

Excerpt from Oxygen Monitor Clean Testing Report Performed in 2010

The Rosemount X-STREAM Series X2GP is a paramagnetic oxygen analyzer with a 0-25% oxygen measurement range. It claims a drift less than 2% of span (0.10% volume oxygen) per week, and a response time of less than 5 seconds (for the analyzer to report 90% of a step change). Our test equipment was set-up such that the same gas was running through each oxygen analyzer at the same time. This allowed Calibration Error, Calibration Drift, and Loss of Power Testing to be run on all monitors at the same time, eliminating any variability between the analyzers from tolerances in the gas cylinder, ambient temperature, ambient pressure, test duration, etc. An APTech pressure regulator was placed on the gas cylinder manifold and a 23 psia Paroscientific pressure transducer measured the regulator’s outlet pressure. This did not give the inlet pressure on any one analyzer but outlet pressure from the manifold before the stream was split. The APTech pressure regulator was used to keep operating conditions consistent. A DWYER rotameter was installed on each oxygen monitor’s outlet piping. With the exception of Variation of Flow Rate Testing, the rotameter was left fully open for all testing. The flow rate through each oxygen monitor was controlled by a Swagelok needle valve that was installed on each analyzer’s inlet piping. Additionally, a filter was installed in the each monitor’s inlet piping to keep particles from the measurement cells and a Swagelok ball valve was installed on each monitor’s outlet piping to isolate each monitor between tests. No pumps were installed. Each of the cylinders used was at a pressure greater than ambient room barometric pressure. This pressure differential was used to move gas through the testing equipment. The flow rate through each analyzer was controlled by the Swagelok needle valve installed on each analyzer’s inlet piping. Finally, for all tests, a Paroscientific Digiquartz Barometer was used to measure ambient room barometric pressure and a Fluke Thermo-hygrometer was used to measure ambient room temperature.

47 OTHER INSTRUMENTATION↗

Full-Scale Testing of the Ambient Pressure, Acid-Dissolution Front-End Process for the Current Mo-99 Recovery Processes

The Global Threat Reduction Initiative (GTRI) Conversion Program is actively developing technologies for the conversion of civilian facilities using high enriched uranium (HEU) to low enriched uranium (LEU) fuels and targets. The conversion of conventional HEU targets to LEU for 99 Mo production requires approximately five times the uranium in a target to maintain the 99 Mo yield on a per target basis. Under GTRI, Argonne is developing two front-end options for current 99 Mo production processes to allow the use of LEU-foil targets. In both processes, the aim is to produce a front-end product that is compatible with current 99 Mo purification operations and will provide the same or higher yield of 99 Mo for the same number of irradiated targets. The two front-end processes under development as part of this project are (1) the dissolution of irradiated LEU foil (up to 250 g in a single batch) and nickel fission recoil barrier in nitric acid at ambient pressure and (2) the electrochemical dissolution of LEU foil in a series of steps that produces an alkaline (basic) solution feed for 99 Mo purification. This report describes the results of performance tests and design optimization of the ambient pressure, nitric acid dissolver system. The design, fabrication, and performance test planning for this system are described in more detail in previous reports (Jerden et al. 2011a,b, 2012). Full-scale demonstrations of both of the front-end processes using irradiated uranium foils are planned to be performed at Oak Ridge National Laboratory this fiscal year.

Jerden, James↗

Full-Scale Testing of the Ambient Pressure, Acid-Dissolution Front-End Process for the Current 99 Mo Recovery Processes

The Global Threat Reduction Initiative (GTRI) Conversion Program is actively developing technologies for converting civilian facilities that use high enriched uranium (HEU) to low enriched uranium (LEU) fuels and targets. The conversion of conventional HEU targets to LEU for the production of 99 Mo production requires approximately five times the uranium in a target to maintain the 99 Mo yield on a per-target basis. Under GTRI, Argonne National Laboratory (Argonne) is developing two frontend options for current 99 Mo production processes to allow the use of LEU-foil targets. In both processes, the aim is to produce a frontend product that is compatible with current 99 Mo purification operations and will provide the same or a higher yield of 99 Mo for the same number of irradiated targets. The two frontend processes under development as part of this project are (1) the dissolution of irradiated LEU foil (up to 250 g in a single batch) and nickel fission recoil barrier in nitric acid at ambient pressure; and (2) the electrochemical dissolution of LEU foil in series of steps that produces an alkaline (basic) solution feed for 99 Mo purification. This report describes results from performance tests and design optimization of the ambient pressure, nitric-acid-dissolver system. The design, fabrication, and performance test planning for this system are described in more detail in previous reports (Jerden et al. 2011a,b, 2012). Full-scale demonstrations of both of the frontend processes using irradiated uranium foils are planned to be performed at Oak Ridge National Laboratory this fiscal year.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Design, analysis and testing of a parallel-kinematic high-bandwidth XY nanopositioning stage

This paper presents the design, analysis, and testing of a parallel-kinematic high-bandwidth XY nanopositioning stage driven by piezoelectric stack actuators. The stage is designed with two kinematic chains. In each kinematic chain, the end-effector of the stage is connected to the base by two symmetrically distributed flexure modules, respectively. Each flexure module comprises a fixed-fixed beam and a parallelogram flexure serving as two orthogonal prismatic joints. With the purpose to achieve high resonance frequencies of the stage, a novel center-thickened beam which has large stiffness is proposed to act as the fixed-fixed beam. The center-thickened beam also contributes to reducing cross-coupling and restricting parasitic motion. To decouple the motion in two axes totally, a symmetric configuration is adopted for the parallelogram flexures. Based on the analytical models established in static and dynamic analysis, the dimensions of the stage are optimized in order to maximize the first resonance frequency. Then finite element analysis is utilized to validate the design and a prototype of the stage is fabricated for performance tests. According to the results of static and dynamic tests, the resonance frequencies of the developed stage are over 13.6 kHz and the workspace is 11.2 μm × 11.6 μm with the cross-coupling between two axes less than 0.52%. It is clearly demonstrated that the developed stage has high resonance frequencies, a relatively large travel range, and nearly decoupled performance between two axes. For high-speed tracking performance tests, an inversion-based feedforward controller is implemented for the stage to compensate for the positioning errors caused by mechanical vibration. The experimental results show that good tracking performance at high speed is achieved, which validates the effectiveness of the developed stage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗