Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Prandtl-Meyer flow tables for parahydrogen at total temperatures from 30K to 290K and for nitrogen at total temperatures from 100K to 300K at total pressures from 1 ATM to 10 ATM

The dependency of Mach number on the Prandtl-Meyer function was numerically determined by iterating the Prandtl-Meyer function and applying the Muller method to converge on the Mach number for flows in cryogenic parahydrogen and nitrogen at various total pressures and total temperatures. The results are compared with the ideal diatomic gas values and are presented in tabular form.

Haut, R. C.↗

Turbine Blade Temperature Measurements Using Thin Film Temperature Sensors

The development of thin film temperature sensors is discussed. The technology for sputtering 2 micron thin film platinum versus platinum 10 percent rhodium thermocouples on alumina forming coatings was improved and extended to applications on actual turbine blades. Good adherence was found to depend upon achieving a proper morphology of the alumina surface. Problems of adapting fabrication procedures to turbine blades were uncovered, and improvements were recommended. Testing at 1250 K at one atmosphere pressure was then extended to a higher Mach No. (0.5) in combustor flow for 60 hours and 71 thermal cycles. The mean time to failure was 47 hours accumulated during 1 hour exposures in the combustor. Calibration drift was about 0.1 percent per hour, attributable to oxidation of the rhodium in the thin films. An increase in film thickness and application of a protective overcoat are recommended to reduce drift in actual engine testing.

Grant, H. P.↗

Influence of deformation behavior, oxydation, and temperature on the long time cyclic stress behavior of high temperature steels

The influence of different parameters on the creep-fatigue behavior of several steel alloys was investigated. The higher the temperature the lower the crack initiation value. Pauses during the cycle reduce the damage. Oxidation reduces and protective gas increases the lifetime. Prior loading and prior deformation reduce the lifetime. Short annealing slightly affects the cycle stress behavior. The test results do not satisfactorily agree with methods of extrapolation and damage accumulation.

Maile, K.↗

A study of enhancing critical current densities (J(sub c)) and critical temperature (T(sub c)) of high-temperature superconductors

The development of pure phase 123 and Bi-based 2223 superconductors has been optimized. The pre-heat processing appears to be a very important parameter in achieving optimal physical properties. The synthesis of pure phases in the Bi-based system involves effects due to oxygen partial pressure, time, and temperature. Orientation/melt-sintering effects include the extreme c-axis orientation of Yttrium 123 and Bismuth 2223, 2212, and 2201 phases. This orientation is conductive to increasing critical currents. A procedure was established to substitute Sr for Ba in Y-123 single crystals.

Vlasse, Marcus↗

Insertion loss and noise-temperature contribution of high-temperature superconducting bandpass filters centered at 2.3 and 8.45 GHz

Two superconducting Tl-Ca-Cu-Ba-O bandpass filters were fabricated for JPL by Superconductor Technologies Incorporated, Santa Barbara, California. The filters were designed to operate at 2.3 GHz (S-band) with a 0.5-dB bandwidth of 60 MHz and at 8.45 GHz (X-band) with a 0.5-dB bandwidth of 150 MHz. The structure selected for both filters incorporates half-wavelength thin-film resonators in a stripline configuration. The S-band filter uses an edge-coupled interdigital design and the X-band filter uses an end-coupled design. The insertion loss and the noise-temperature contribution were measured at 12 K for both filters.

Prater, J. L.↗

Experimental Measurements of Temperature and Heat Flux in a High Temperature Black Body Cavity

During hypersonic flight, high temperatures and high heat fluxes are generated. The Flight Loads Laboratory (FLL) at Dryden Flight Research Center (DFRC) is equipped to calibrate high heat fluxes up to 1100 kW/sq m. There are numerous uncertainties associated with these heat flux calibrations, as the process is transient, there are expected to be interactions between transient conduction, natural and forced convection, radiation, and possibly an insignificant degree of oxidation of the graphite cavity. Better understanding, of these mechanisms during the calibration process, will provide more reliable heat transfer data during either ground testing or flight testing of hypersonic vehicles.

Abdelmessih, Amanie N.↗

Using Pressure- and Temperature-Sensitive Paint for Global Surface Pressure and Temperature Measurements on the Aft-Body of a Capsule Reentry Vehicle

Pressure Sensitive Paint (PSP) and Temperature Sensitive Paint (TSP) were used to visualize and quantify the surface interactions of reaction control system (RCS) jets on the aft body of capsule reentry vehicle shapes. The first model tested was an Apollo-like configuration and was used to focus primarily on the effects of the forward facing roll and yaw jets. The second model tested was an early Orion Crew Module configuration blowing only out of its forward-most yaw jet, which was expected to have the most intense aerodynamic heating augmentation on the model surface. This paper will present the results from the experiments, which show that with proper system design, both PSP and TSP are effective tools for studying these types of interaction in hypersonic testing environments.

Watkins, A. Neal↗

NASA PS400: A New Temperature Solid Lubricant Coating for High Temperature Wear Applications

A new solid lubricant coating, NASA PS400, has been developed for high temperature tribological applications. This plasma sprayed coating is a variant of the patented PS304 coating and has been formulated to provide higher density, smoother surface finish and better dimensional stability than PS304. PS400 is comprised of a nickel-molybdenum binder that provides strength, creep resistance and extreme oxidative and dimensional stability. Chromium oxide, silver and barium-calcium fluoride eutectic are added to the binder to form PS400.Tribological properties were evaluated with a pin-on-disk test rig in sliding contact to 650 C. Coating material samples were exposed to air, argon and vacuum at 760 C followed by cross section microscopic analysis to assess microstructure stability. Oil-Free microturbine engine hot section foil bearing tests were undertaken to assess PS400 s suitability for hot foil gas bearing applications. The preliminary results indicate that PS400 exhibits tribological characteristics comparable to the PS304 coating but with enhanced creep resistance and dimensional stability suitable for demanding, dynamic applications.

DellaCorte, C.↗

Fiber Optic Temperature Sensor Insert for High Temperature Environments

A thermal protection system (TPS) test plug has optical fibers with FBGs embedded in the optical fiber arranged in a helix, an axial fiber, and a combination of the two. Optionally, one of the optical fibers is a sapphire FBG for measurement of the highest temperatures in the TPS plug. The test plug may include an ablating surface and a non-ablating surface, with an engagement surface with threads formed, the threads having a groove for placement of the optical fiber. The test plug may also include an optical connector positioned at the non-ablating surface for protection of the optical fiber during insertion and removal.

Black, Richard James↗

Improving SMAP freeze-thaw retrievals for pavements using effective soil temperature from GEOS-5: Evaluation against in situ road temperature data over the U.S

Seasonal freeze-thaw (FT) affects over half the northern hemisphere and impacts many key processes of the Earth System such as energy exchange, hydrology and vegetation. Nearly all past studies using spaceborne FT retrievals have focused on characterizing FT specifically for natural environments. FT in the built environment is also routinely studied and a topic of great interest, especially with regards to transportation infrastructure. Whereas natural FT process are frequently investigated using spaceborne observations, FT studies of roads are often limited to local scales, using in situ or nearby weather station data only. Comparisons between FT retrievals obtained from NASA's Soil Moisture Active Passive (SMAP) satellite and roads in Alaska (AK) and the Contiguous United States (CONUS) showed that spaceborne FT retrievals had good agreement with road data. But those results also indicated that NASA FT retrievals in CONUS were relatively too warm compared to road data. If SMAP FT retrievals were to be used for identifying FT transition timing for applications by the transportation community, it is also important for frozen conditions to be identified more accurately. This work is primarily concerned with improving frozen retrievals made in CONUS by calculating new Normalized Polarization Ratio (NPR) thresholds as compared to those currently used in SMAP FT. We found that focusing on a temporal subset of October through May for comparisons greatly improved the correlation between NPR and effective soil temperature (Teff, one of SMAP's ancillary datasets), often from about zero to 0.6. We then applied linear regression between NPR and Teff to obtain new NPR thresholds resulting in the FT-Roads (FT-R) product. NASA FT and FT-R were evaluated against road data at about 1000 locations in CONUS and a battery of different tests indicated that FT-R performed better under nearly all conditions compared to NASA FT. Overall, NASA FT accuracies were 69% and 80% for 6 am and 6 pm SMAP retrievals, while FT-R achieved accuracies of 79% and 82%. We also investigated the potential for using Teff for road FT (6 am, only) and found that those comparisons were even more accurate (84%). We've also quantified inter- and intraregional differences of SMAP FT performance and found that accuracy metrics vary over twice as much between geographic subdivisions (9%) as compared to between the states within a subdivision (4%). Most importantly, the main goal of improving the detection of in situ frozen conditions in CONUS was realized, with FT-R accurately detecting frozen conditions >50% more frequently than NASA FT.

Passive microwave↗

High-temperature NMR MAS probe with optimized temperature gradient across sample rotor

A rotor housing assembly for NMR spectroscopy. An elongate rotor has a distal drive end, a proximal end and an internal sample space positioned along its length between the drive and proximal ends. The rotor is driveable about a rotation axis by a drive gas flow. A rotor housing has an interior space in which the rotor is at least partially received. At least one first heated gas flow inlet is positioned opposite the internal sample space, through which a first heated gas flow is controllably flowable into the interior space to heat it and the rotor. At least a pair of spaced apart second heated gas flow outlets are axially spaced from the first heated gas flow inlet to controllably convey a second heated gas flow to heat distal and proximal areas of the sample space to minimize a temperature gradient extending axially within the sample space.

Mehta, Hardeep S.↗