Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

A broadband wavelet implementation for rapid ultrasound pulse-echo time-of-flight measurements

A broadband wavelet approach to ultrasonic pulse-echo time-of-flight measurements is described. The broadband approach significantly reduces the time required for frequency-dependent pulse-echo measurements, enabling studies of dynamic systems ranging from biological systems to solid-state phase transitions. The described broadband approach is demonstrated in parallel with the more traditional frequency stepping approach to perform ultrasound time-of-flight measurements inside a large volume Paris-Edinburgh press in-situ at a synchrotron source. The broadband wavelet data acquisition process was found to be 1-2 orders of magnitude faster than the steppedfrequency approach, with no compromise in data quality or determined results.

47 OTHER INSTRUMENTATION↗

Applying fast calorimetry on a spent nuclear fuel calorimeter

Recently at Los Alamos National Laboratory, sophisticated prediction algorithms have been considered for the use of calorimetry for treaty verification. These algorithms aim to predict the equilibrium temperature based on early data and therefore be able to shorten the measurement time while maintaining good accuracy. The algorithms have been implemented in MATLAB and applied on existing equilibrium measurements from a spent nuclear fuel calorimeter located at the Swedish nuclear fuel interim storage facility. The results show significant improvements in measurement time in the order of 15 to 50 compared to equilibrium measurements, but cannot predict the heat accurately in less time than the currently used temperature increase method can. This Is both due to uncertainties in the calibration of the method as well as identified design features of the calorimeter that limits the usefulness of equilibrium type measurements. The conclusions of these findings are discussed, and suggestions of both improvements of the current calorimeter as well as what to keep in mind in a new design are given.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High frequency, high time resolution time-to-digital converter employing passive resonating circuits

A method for measuring time intervals accurate to the picosecond range is based on phase measurements of oscillating waveforms synchronous with their beginning and/or end. The oscillation is generated by triggering an LC resonant circuit, whose capacitance is precharged. By using high Q resonators and a final active quenching of the oscillation, it is possible to conjugate high time resolution and a small measurement time, which allows a high measurement rate. Methods for fast analysis of the data are considered and discussed with reference to computing resource requirements, speed, and accuracy. Experimental tests show the feasibility of the method and a time accuracy better than 4 ps rms. Methods aimed at further reducing hardware resources are finally discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Growth and characterization of high-performance photorefractive BaTiO3 crystals

Barium titanate has been used for many nonlinear optical applications primarily because it has high grain and high self-pumped phase conjugate reflectivities. However, barium titanate has had a relatively slow response time, and thus low sensitivity. Therefore, it has not been suited to real-time operations. In this report we will describe the modifications in crystal growth, doping, reduction, and poling that have produced barium titanate crystals with the fastest photorefractive response time reported to date, approximately 21 microseconds with a beam-coupling gain coefficient of 38.7 cm(exp -1) and the highest sensitivity reported to date of 3.44 cm(exp 3)/kJ. The sensitivity of these barium titanate crystals is comparable to or greater than other photorefractive oxides. We will show, for the first time, beam-coupling in barium titanate at video frame rates. We infer from response time measurements that barium titanate has a phonon limited mobility. Also, photorefractive response time measurements as a function of the crystallographic orientation and grating wave vector for our cobalt-doped oxygen reduced crystals indicate that their faster response time arise because of an increase in the free carrier lifetime.

Warde, C.↗

Crickets{sup TM} and Curies: Lessons Learned from the Steel Industry - 18221

The global nuclear power industry, and to a lesser extent, the decommissioning and demolition of old nuclear weapons plants, obviously present challenges to those in the radioactive waste management field. Some if not many of these challenges have already been dealt with, and resolved, in the steel industry, including its recycling component. This paper presents proven state-of-the-art radiation detection systems used in steel and related recycling facilities, emphasizing current, reliable and flexible technologies for characterization, volume reduction, and remote handling of recyclable solid wastes contaminated and, just as important, not contaminated, with a wide range of radioactive isotopes. It will also cover features of remotely operated waste handling equipment effective in reducing or eliminating exposure of workers engaged in decontamination and demolition work on active and/or inactive nuclear installations. The industry group identified above has a long-standing policy regarding any radioactivity in potentially recyclable as well as waste materials it receives: if it is detected, it is rejected. The US Steel Manufacturers Association (SMA) put it this way in one of their Public Policy Statements: 'SMA members have not, and will not, accept scrap that is known to be radioactively contaminated' (emphasis included in the original) (1). This policy, adopted around the globe, obviously has major implications for decommissioning and demolition projects. To put it bluntly, if rad-contaminated metal, concrete, or other materials are sent to a facility for possible recycling, reuse or even disposal, they may well be rejected. If so, the materials will be returned to the generator--at the generator's cost-and a new solution will have to be found. This also results in additional costs for the generator. Facilities in the steel making and metal recycling industries have access to, and routinely count on, a wide range of proven detection technologies and techniques for monitoring incoming shipments and sorting the materials in them. The approaches range from using sensitive handheld instruments for pinpointing and isolating small devices such as isotope-containing gauges and radium dials all the way up to technologies effective for large volumes and weights of contaminated construction and demolition material. In this latter realm, the most suitable, robust, and field-proven system for decommissioning and demolition work is a radiation detection system fitted to a grappling and/or magnetic device, known as the Crickets{sup TM} technology, which automatically scans bulk material with no added effort or time in material handling operations. Highly versatile, a Crickets{sup TM} system can be put to work on any material-handling system, including grapples handling volumes ranging from 1 up to 18 cubic yards, while detecting radioactivity in real-time over a very wide dose range, from nSv to Sv levels. Other field-proven real-time measuring radiation detection devices can be fixed to conveyor belts with traverse speeds up 3 meters/second, also measuring in real time and over the same dose range, allowing both recyclable and waste materials with a pre-set level of radioactivity to be diverted off the belt. Finally, there are highly sensitive radiation portal installations for detecting radiation from materials being transported by vehicles, including those with roll-offs, dump trailers, and other containers, again in real-time and for the same dose ranges. For vehicles, the speed must be carefully controlled-the vehicles need to travel from 5 to 10 km/h through the scanning zone to ensure that maximum detection capability is maintained. When radiation detection systems at recycling and steel making facilities detect radioactive material in an incoming shipment, these facilities have a zero tolerance for accepting the cargo. Therefore, it is imperative that material from a demolition operation that is slated to be sent for recycling or other reuse be checked at the point of demolition at similar detection levels to avoid possible rejection later of a shipment because of its radioactivity. In addition to measuring overall radiation levels (for example, total gamma), when necessary, combinations of different radiation detection media can be used to detect the presence and intensities of specific isotopes such as U-235, Cs-137, Co-60, Am-241, etc., again in real-time and over a similar dose range. These detection technologies can be fixed or transportable. More important for the rad-waste management profession, this overall systems approach can be tailored and adapted during use on-site in any dismantling, demolition or remediation project, to allow materials to be thoroughly scanned before being released to the recycling stream for reuse, or to appropriate long-term storage and disposal facilities. Potentially recyclable materials with contamination such as steel beams and rebar will set off alarms at recycling facilities, resulting in unnecessary added expenses to the generator, primarily due to increased transportation costs, time delays and additional rad-waste handling and disposal charges. Additionally, there are situations where relatively lightly contaminated materials, once identified and appropriately characterized, can be reused in new construction applications, such as concrete from demolition being used in the base layer for roads or recycled steel used for repair or construction of bridges. In other cases, specific smaller volumes can be sent to specialized rad-waste disposal sites. These radiation detection systems can also be custom tailored to ensure proper handling and disposition of contaminated materials destined for reuse in specific applications where, for example, acceptable levels of radioactivity in NORM or TENORM can be reused or safely disposed of. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Time-domain measurement of terahertz frequency magnetoplasmon resonances in a two-dimensional electron system by the direct injection of picosecond pulsed currents

We have investigated terahertz (THz) frequency magnetoplasmon resonances in a two-dimensional electron system through the direct injection of picosecond duration current pulses. The evolution of the time-domain signals was measured as a function of magnetic field, and the results were found to be in agreement with calculations using a mode-matching approach for four modes observed in the frequency range above 0.1 THz. This introduces a generic technique suitable for sampling ultrafast carrier dynamics in low-dimensional semiconductor nanostructures at THz frequencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time Alignment of the CMS Hadron Calorimeter

The Hadron Calorimeter (HCAL) in the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) was recently upgraded for Run 3 (2022-2025) to introduce depth segmentation and online timing measurements. With increased segmentation and readout channels, the HCAL provides new timing capabilities for jets and hadronic tau decays with nearly 4π coverage and sensitivity to highly displaced decays within the calorimeter volume. Recent HCAL timing scans provide a valuable look at artificially delayed jets in collision data and are crucial to improving the detector’s performance. Online timing is utilized for detector alignment based on positioning the pulse rising edge, achieving an alignment accuracy of 0.5 ns, considerably higher than previous energy-weighting based approaches. Using precision arrival time measurements, significant advances have been made in understanding the propagation of hadronic showers throughout the calorimeter.

Kopp, Gillian [Princeton Univ., NJ (United States)↗

The ETROC2 as the Final Version for CMS Endcap Timing Layer (ETL) Upgrade

The ETROC (Endcap Timing Readout Chip) is being developed for the LGAD-based CMS Endcap Timing Layer (ETL) at HL-LHC. The ETL on each side of the interaction region will be instrumented with a two-disk system of MIP-sensitive LGAD (Low Gain Avalanche Diodes) silicon devices, read out by ETROCs for precision timing measurement with down to ~30 ps timing resolution per track. The ETROC is designed to handle a 16 x 16 pixel cell matrix, with each pixel being 1.3 mm x 1.3 mm to match the LGAD sensor pixel size. The front-end design for preamplifier and discriminator has been specifically optimized for the reduced LGAD signals, with enough flexibilities to meet the ETL specific needs for time resolution, power budget and radiation profile. The ETROC chip is implemented in a commercial 65nm CMOS process. Each channel consists of a preamplifier, a discriminator, a TDC used for TOA (Time Of Arrival) and TOT (Time Over Threshold) measurements, and a memory for data storage and readout. An in-pixel auto threshold calibration is included, along with a self-testing pattern generator. The TOT is used for time-walk correction of the TOA measurement. The detailed hit information (TOA and TOT) from each cell will be read out from a local circular buffer after each Level-1 Accept (about 1 MHz). In addition, a charge injection circuit is implemented to allow for testing and calibration. For more detailed monitoring of the signal pulses, waveform sampling circuits are included for one pixel. The clock distribution is based on a 16x16 H-tree design with a shielding structure to alleviate potential interference. The global peripheral circuits include a PLL, a phase shifter, an I2C slave controller, a fast control block, a global readout, and a data driver along with an efuse and temperature sensor. The ETROC builds event data frames for each L1A selected event and is also capable of providing L1 trigger information for user-defined delayed hits. The main design challenge is how to extract precision timing information from the small LGAD signals in the presence of high irradiation fluence, while keeping the power consumption and digital activity low. The ETL design goal for the time resolution of 50 ps per hit is required to achieve a 35 ps arrival time measurement for a MIP particle, which has its track registered in two ETL disk layers. The LGAD contribution is known to be about 30 ps, this means that the jitter from the ETROC has to be kept below 40 ps. The ETROC2 is the first full size full functionality prototype design fully compatible with the final chip specifications for CMS ETL and now becomes the final version. The ETROC2 chips have been extensively tested. We will present here new testing results including the bump bonding yield improvement study, the time walk correction (TWC) generality study with one pixel TWC applying to all pixels, the final SEU testing using both heavy ion and proton beam, more beam test studies including different sensors, and readiness for the ETROC2 production for CMS ETL upgrade.

Liu, Tiehui [Fermilab] (ORCID:0009000765225605)↗

Time domain measurement of frequency stability: A tutorial introduction

The theoretical basis behind the definition of frequency stability in the time domain is outlined. Various types of variances were examined. Their differences and interrelation are pointed out. Systems that are generally used in the measurement of these variances are described.

Vanier, J.↗

Oxidation and pyrolysis of methyl propyl ether

The ignition, oxidation, and pyrolysis chemistry of methyl propyl ether (MPE) was probed experimentally at several different conditions, and a comprehensive chemical kinetic model was constructed to help understand the observations, with many of the key parameters computed using quantum chemistry and transition state theory. Experiments were carried out in a shock tube measuring time variation of CO concentrations, in a flow tube measuring product concentrations, and in a rapid compression machine (RCM) measuring ignition delay times. The detailed reaction mechanism was constructed using the Reaction Mechanism Generator software. Sensitivity and flux analyses were used to identify key rate and thermochemical parameters, which were then computed using quantum chemistry to improve the mechanism. Validation of the final model against the 1-20 bar 600-1500 K experimental data is presented with a discussion of the kinetics. The model is in excellent agreement with most of the shock tube and RCM data. Strong non-monotonic variation in conversion and product distribution is observed in the flow-tube experiments as the temperature is increased, and unusually strong pressure dependence and significant heat release during the compression stroke is observed in the RCM experiments. These observations are largely explained by a close competition between radical decomposition and addition to O2 at different sites in MPE; this causes small shifts in conditions to lead to big shifts in the dominant reaction pathways. The validated mechanism was used to study the chemistry occurring during ignition in a diesel engine, simulated using Ignition Quality Test (IQT) conditions. At the IQT conditions, where the MPE concentration is higher, bimolecular reactions of peroxy radicals are much more important than in the RCM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the measurement of time for the quantum harmonic oscillator

A generalization of previous treatments of quantum phase is presented. Restrictions on the class of realizable phase statistics are thereby removed; thus, permitting 'phase wavefunction collapse' (and other advantages). This is accomplished by exciting the auxiliary mode of the measurement apparatus in a time-reversed fashion. The mathematical properties of this auxiliary mode are studied in the hope that they will lead to an identification of a physical apparatus which can realize the quantum phase measurement.

Shepard, Scott R.↗

Reconstructing the Position and Intensity of Multiple Gamma-Ray Point Sources with a Sparse Parametric Algorithm

IEEE We present an experimental demonstration of Additive Point Source Localization (APSL), a sparse parametric imaging algorithm that reconstructs the 3D positions and activities of multiple gamma-ray point sources. Using a handheld gamma-ray detector array and up to four 8 μCi 137 Cs gamma-ray sources, we performed both source-search and source-separation experiments in an indoor laboratory environment. In the majority of the source-search measurements, APSL reconstructed the correct number of sources with position accuracies of ~20 cm and activity accuracies (unsigned) of ~20%, given measurement times of two to three minutes and distances of closest approach (to any source) of ~20 cm. In source-separation measurements where the detector could be moved freely about the environment, APSL was able to resolve two sources separated by 75 cm or more given only ~60 s of measurement time. In these source-separation measurements, APSL produced larger total activity errors of ~40%, but obtained source separation distances accurate to within 15 cm. We also compare our APSL results against traditional Maximum Likelihood-Expectation Maximization (ML-EM) reconstructions, and demonstrate improved image accuracy and interpretability using APSL over ML-EM. These results indicate that APSL is capable of accurately reconstructing gamma-ray source positions and activities using measurements from existing detector hardware.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reexamination of data from the asteroid/meteoroid detector

The discovery of the existence of cosmoids, a class of meteoroid in near hyperbolic orbits, was made in a reevaluation of the Sisyphus Experiment on Pioneer 10 and 11. This experiment measured the spontaneous jetting of cosmoids and showed that the dispersion and increase in brightness occurs in microseconds and lasts only briefly. Cosmoid jetting caused multiple telescope thresholds to be exceeded simultaneously which explains the earlier inabilty to compute trajectories from the measured times in the fields of view. A new calculation correlated the Sisyphus individual event measurements with the zodiacal light. That the meteoroid population is dominated by cosmoids is demonstrated. Reported telescopic small comets, measured by a similar optical technique, appear consistent with the Sisyphus results. Characteristic jetting times measured by Sisyphus also show that the volatile cosmoids could not survive in short period orbits.

Soberman, Robert K.↗

Direct and real time probe of photoinduced structure transition in colossal magnetoresistive material

Here, we report a direct and real time measurement of photoinduced structure phase transition in single crystal La 0.84 Sr 0.16 MnO 3 using femtosecond electron diffraction. The melting of orthorhombic lattice ordering under femtosecond optical excitation is found involving two distinct processes with different time scales, an initial fast melting of orthorhombic phase in about 4 ps and a subsequent slower transformation in 90 ps and longer timescales. Furthermore, the fast process is designated as the initial melting of orthorhombic phase induced by the Mn-O bond change that is most likely driven by the quenching of the dynamic Jahn-Teller distortion following the photo-excitation. We attribute the slow process to the growing of newly formed structure domain from the photo-excited sites to the neighboring non-excited orthorhombic sites.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Transducerless time domain reflectance measurement of semiconductor thermal properties

The dominant techniques for laser-based thermal measurement, time-domain thermoreflectance (TDTR) and frequency-domain thermoreflectance, generally require that samples be coated with a metal transducer layer. The properties of the transducer and its interface to the sample are then important to the interpretation of results, and heat conduction in the transducer layer can limit measurements of ultra-thin samples or in-plane conductivity. Here, we demonstrate the feasibility of measuring semiconductor samples using standard TDTR instrumentation, without the use of a metal transducer. A mathematical model accounting for non-zero laser penetration depth as well as both thermal and charge carrier effects is presented, and the ability of the model to describe and fit to experimental data for silicon and germanium samples is demonstrated. Though at this stage measurement uncertainties are larger than for traditional TDTR, we anticipate that the use of this technique will expand the range of samples that can be measured with existing TDTR setups.

36 MATERIALS SCIENCE↗

A Comparison of Three Ways to Measure Time-Dependent Densities With Quantum Simulators

Quantum algorithms are touted as a way around some classically intractable problems such as the simulation of quantum mechanics. At the end of all quantum algorithms is a quantum measurement whereby classical data is extracted and utilized. In fact, many of the modern hybrid-classical approaches are essentially quantum measurements of states with short quantum circuit descriptions. Here, we compare and examine three methods of extracting the time-dependent one-particle probability density from a quantum simulation: direct Z -measurement, Bayesian phase estimation, and harmonic inversion. We have tested these methods in the context of the potential inversion problem of time-dependent density functional theory. Our test results suggest that direct measurement is the preferable method. We also highlight areas where the other two methods may be useful and report on tests using Rigetti's quantum virtual device. This study provides a starting point for imminent applications of quantum computing.

Yang, Jun↗

Manometer Measures Gas Flow

Simple apparatus measures time required for gas to displace known volume of water. Apparatus determines amount of gas generated in lead/acid cell during charging by measuring time required for gas to displace measured volume of water between markes in slanted manometer.

Rowlette, J. J.↗

Note: Precision viscosity measurement using suspended microchannel resonators

We report the characterization of a suspended microchannel resonator (SMR) for viscosity measurements in a low viscosity regime (<10 mPa s) using two measurement schemes. First, the quality factor (Q-factor) of the SMR was characterized with glycerol-water mixtures. The measured Q-factor at 20 Degree-Sign C exhibits a bilinear behavior with the sensitivity of 1281 (mPa s){sup -1} for a lower (1-4 mPa s) and 355 (mPa s){sup -1} for a higher viscosity range (4-8 mPa s), respectively. The second scheme is the vibration amplitude monitoring of the SMR running in a closed loop feedback. When compared in terms of the measurement time, the amplitude-based measurement takes only 0.1 {approx} 1 ms while the Q-factor-based measurement takes {approx}30 s. However, the viscosity resolution of the Q-factor-based measurement is at least three times better than the amplitude-based measurement. By comparing the Q-factors of heavy water and 9.65 wt.% glycerol-water mixture that have very similar viscosities but different densities, we confirmed that the SMR can measure the dynamic viscosity without the density correction. The obtained results demonstrate that the SMR can measure the fluid viscosity with high precision and even real-time monitoring of the viscosity change is possible with the amplitude-based measurement scheme.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗