Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TABLE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Advances in full field microscopy with table-top soft x-ray lasers

We describe recent advances in the demonstration of table-top full field microscopes that use soft x-ray lasers for illumination. We have achieved wavelength resolution and single shot exposure operation with a very compact 46.9 nm microscope based on a desk-top size capillary discharge laser. This {lambda}-46.9 nm microscope has been used to capture full field images of a variety of nanostructure systems and surfaces. In a separate development we have demonstrated a zone plate microscope that uses {lambda}=13.2 nm laser illumination to image absorption defects in an extreme ultraviolet lithography (EUVL) mask in the same geometry used in a 4x demagnification EUVL stepper. Characterization of the microscope’s transfer function shows it can resolve 55 nm half period patterns. With these capabilities, the {lambda}-13.2 nm microscope is well suited for evaluation of pattern and defect printability of EUVL masks for the 22 nm node.

36 MATERIALS SCIENCE↗

TU-F-BRF-09: Feasibility Study of Spatial and Temporal Fractionation Using a Table-Top Image-Guided MRT System

Purpose: Microbeam radiation therapy is a promising experimental radiotherapy method for cancer treatment. Synchrotron studies have shown that MRT can preferentially ablate tumors while mostly preserving the surrounding normal tissues. Our purpose is to develop a compact microbeam irradiator that can be accessible for laboratory research on MRT's therapeutic mechanism, with the ultimate goal of translating this technique for clinical applications. Utilizing a carbon nanotube field emission X-ray source array, our lab has developed a first of its kind table-top microbeam irradiator. The purpose of this study is to investigate the possibility of increasing the total dose to the tumor region using spatial and temporal fractionation. Methods: MRI and CT scans were acquired and registered to locate both the target region and the landmark in the treatment coordinate space. A crossbeam treatment configuration was planned to achieve the desired dosage and tumor coverage. One array of 300 μm-thick microbeams was delivered to the target on the first day. Another array, perpendicular to the first one, was delivered the next day targeting the same region. The feasibility of this image-guided MRT procedure was evaluated using a phantom. Gafchromic EBT2 film was employed to characterize the targeting accuracy and the delivered tumor dose. Results: The preliminary phantom study showed that a cross-pattern of microbeam arrays was successfully delivered with sub-millimeter targeting accuracy. The delivered dose in the target region was doubled. The fraction of tumor volume that received the peak dose was increased. Conclusion: Temporal fractionation of crosspatterned microbeams can be delivered to the same target region. The feasibility of this procedure was investigated with a phantom study. Once implemented, this procedure has the potential of increasing the tumor control effect of MRT and of achieving better normal tissue recovery.

60 APPLIED LIFE SCIENCES↗

SU-F-J-28: Development of a New Imaging Filter to Remove the Shadows From the Carbon Fiber Grid Table Top

Purpose: For the image guided radiation therapy (IGRT), the shadows caused by the construction of the treatment couch top adversely affect the visual evaluation. Therefore, we developed the new imaging filter in order to remove the shadows. The performance of the new filter was evaluated using the clinical images. Methods: The new filter was composed of the band-pass filter (BPF) weighted by the k factor and the low-pass filter (LPF). In the frequency region, the stop bandwidth were 8.3×10{sup 3} mm{sup −1} on u direction and 11.1×10{sup 3} mm{sup −1} on v direction for the BPF, and the pass bandwidth were 8.3×10{sup 3} mm{sup −1} on u direction and 11.1×10{sup 3} mm{sup −1} on v direction for the LPF. After adding the filter, the shadows from the carbon fiber grid table top (CFGTT, Varian) on the kV-image was removed. To check the filter effect, we compared the clinical images, which are thorax and thoracoabdominal region, with to without the filter. The subjective evaluation tests was performed by adapting a three-point scale (agree, neither agree nor disagree, disagree) about the 15 persons in the department of radiation oncology. Results: We succeeded in removing all shadows of CFGTT using the new filter. This filter is very useful shown by the results of the subjective evaluation having the 23/30 persons agreed to the filtered clinical images. Conclusion: We concluded that the proposed method was useful tool for the IGRT and the new filter leads to improvement of the accuracy of radiation therapy.

60 APPLIED LIFE SCIENCES↗

Laser Acceleration of Nuclei for Synthesis of Superheavy Elements in the Stability Island of the Periodic Table

Within a three-dimensionalmodel of interaction of a powerful electromagnetic fieldwith plasma of solid-state density, the effect of acceleration of calcium nuclei ({sub 20}{sup 48}Ca) to high energies that are likely to be sufficient for the synthesis of superheavy elements within the “stability island” of the periodic table of elements is obtained by numerically solving the Vlasov–Maxwell equations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Large-scale mass table calculations

Systematic self-consistent nuclear mass calculations, based on the nuclear density functional theory, represent a rich scientific agenda that is closely aligned with the main research directions in modern nuclear structure and astrophysics, especially in the context of the radioactive nuclear beam physics. The status of large-scale mass calculations carried out under the UNEDF project and the development of the mass-table visualization software are briefly discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

One SQL to Rule Them All - an Efficient and Syntactically Idiomatic Approach to Management of Streams and Tables

Real-time data analysis and management are increasingly critical for today's businesses. SQL is the de facto lingua franca for these endeavors, yet support for robust streaming analysis and management with SQL remains limited. Many approaches restrict semantics to a reduced subset of features and/or require a suite of non-standard constructs. Additionally, use of event timestamps to provide native support for analyzing events according to when they actually occurred is not pervasive, and often comes with important limitations. We present a three-part proposal for integrating robust streaming into SQL, namely: (1) time-varying relations as a foundation for classical tables as well as streaming data, (2) event time semantics, (3) a limited set of optional keyword extensions to control the materialization of time-varying query results. We show how with these minimal additions it is possible to utilize the complete suite of standard SQL semantics to perform robust stream processing. We motivate and illustrate these concepts using examples and describe lessons learned from implementations in Apache Calcite, Apache Flink, and Apache Beam. We conclude with syntax and semantics of a concrete proposal for extensions of the SQL standard and note further areas of exploration.

Begoli, Edmon↗

Tool Support for Software Lookup Table Optimization

A number of scientific applications are performance-limited by expressions that repeatedly call costly elementary functions. Lookup table (LUT) optimization accelerates the evaluation of such functions by reusing previously computed results. LUT methods can speed up applications that tolerate an approximation of function results, thereby achieving a high level of fuzzy reuse. One problem with LUT optimization is the difficulty of controlling the tradeoff between performance and accuracy. The current practice of manual LUT optimization adds programming effort by requiring extensive experimentation to make this tradeoff, and such hand tuning can obfuscate algorithms. In this paper we describe a methodology and tool implementation to improve the application of software LUT optimization. Our Mesa tool implements source-to-source transformations for C or C++ code to automate the tedious and error-prone aspects of LUT generation such as domain profiling, error analysis, and code generation. We evaluate Mesa with five scientific applications. Our results show a performance improvement of 3.0× and 6.9× for two molecular biology algorithms, 1.4× for a molecular dynamics program, 2.1× to 2.8× for a neural network application, and 4.6× for a hydrology calculation. We find that Mesa enables LUT optimization with more control over accuracy and less effort than manual approaches.

Wilcox, Chris↗

Sequence Diagrams & PFMEA Table - VGI [SWR-25-107]

As part of the VGI work under the National Charging Experience (ChargeX) Consortium, reliability analysis of communication interfaces for multiple SCM/VGI use-cases was performed using a Process Failure Modes and Analysis (PFMEA) style framework. This repository hosts all the relevant files for each of these use-cases which include: *A visual representation of their communication architecture: Image file (.png) *UML sequence diagram: Plant-UML source file (.puml). Visio file (.vsdx) and image file (.png) derived from the UML sourceX` *The PFMEA table: Excel file (.xlsx) These files are meant to serve as a starting point and can be adapted to company / organization specific SCM implementation.

Gadamsetty, Pranav [National Renewable Energy Labo↗

Generic Comparison Table Prompt And Footnote Validator

This consist of a detailed prompt to be used with a LLM (Tested with Claude 4.5) to prompt for a topic and then generate a comparison/landscape table. The prompt can be modified and tailored to fit the user's specific needs.

Beckman, BryanR [Idaho National Laboratory (INL), ↗

ESS-DIVE Reporting Format for Amplicon Abundance Table

While standardized sequencing data is available in public repositories and efforts such as MIxS for common sample collection and processing metadata are well established, the lack of common bioinformatic processing metadata has hindered the ability to do large-scale metaanalyses and the potential for data re-use by non-experts such as ecosystem, watershed, or earth system modelers. To address this need for Department of Energy researchers, we have developed an amplicon reporting format which captures both sample preparation and bioinformatic processing metadata and stores processed amplicon data as a paired abundance table and sequencing file to maximize the potential for re-use of these data. To aid in the adoption of accessible and reproducible analysis workflows, this reporting format was developed in concert with amplicon functionality within the Department of Energy’s Systems Biology Knowledgebase (KBase) to ensure common data and metadata requirements and facilitate seamless transfer between these platforms.This dataset contains support documentation for the amplicon reporting format (README.md and instructions.md), templates for both bioinformatic and sequencing metadata (amplicon_bioinformatic_metadata_template_2021_10_03.csv and amplicon_sequencing_metadata_template_2021_10_03.csv), a crosswalk indicating how this reporting format relates to the current MIxS format (ESSDIVE-MIxS_crosswalk.csv), a list of available instrument terms (amplicon_seq_instrument_terms_2021_10_03.csv), a map between QIIME2 parameter settings and metadata fields (amplicon_qiime2_plugin_metadata_map.csv), a data dictionary (amplicon_CSV_dd.csv), and file-level metadata (amplicon_FLMD.csv).

54 ENVIRONMENTAL SCIENCES↗

Monitoring of ground water table depth and soil moisture at the Point Reyes field site

Ground water table (GWT) depth and soil moisture (SM) have been monitored at several locations at the Point Reyes field site (Californian coastal grassland) from 2021 to 2024. Monitoring is still on-going and data may be added to this archive at later time. The SM data have been acquired using Teros 12 Meter soil moisture sensors placed at 10, 30, 60 and 90 cm depth at 5 locations along a small hillslope. These sensors also collect soil temperature and bulk conductance. In addition, some collocated sensors provide pore pressure and Photochemical Reflectance Index (PRI). The GWT depth has been inferred from various type of Onset pressure transducers. The pressure measurements have been corrected for atmospheric pressure variations and sensor position relative to the ground surface to infer GWT depth, as well as with RTK GPS data to infer GWT elevation. The GWT data have been acquired at 5 distinct locations from 2020 to 2024 with the sensors placed at about 4 m depth. In addition, GWT data has been acquired for the 2023-2024 period with sensors located in 1 m deep shallow wells installed near each deeper well. This data is intended to evaluate possibly different dynamic in shallow (perched) and deep aquifer. The datasets are all provided in csv format. Please note that the interpretation of the GWT data needs to be done with consideration of environmental and well characteristics at the site and uncertainty in various variables. For more information on GWT and SM data, please contact the author.

54 ENVIRONMENTAL SCIENCES↗

FutureGen 2.0 1008 Simulation Reservoir Lookup Table

Lookup table of pressures and saturations from injection layer of FutureGen 2.0 reservoir model developed using the STOMP simulator. A 20-year injection period with CO2 injection at a rate of 1.1 MMT of CO2 per year is followed by a 50-year post-injection period. The permeability of each of the 31 model layers was varied independently using Latin Hypercube Sampling.

carbon storage↗

Geometric Optimization of the 56MHz SRF Cavity and its Frequency Table

It is essential to know the frequency of a Superconducting Radio Frequency (SRF) cavity at its “just being fabricated” stage because frequency is the key parameter in constructing the cavity. In this paper, we report our work on assessing it. We can estimate the frequency change from stage to stage theoretically and/or by simulation. At the operating stage, the frequency can be calculated accurately, and, from this value, we obtain the frequencies at other stages. They are listed in a table that serves to check the processes from stage to stage. Equally important is optimizing the geometric shape of the SRF cavity so that the peak electric-field and peak magnetic-field are as low as possible. It is particularly desirable in the 56MHz SRF cavity of RHIC to maximize the frequency sensitivity of the slow tuner. After undertaking such optimization, our resultant peak electric-field is only 35.3MV/m, and the peak magnetic-field is 840G at 2MV of voltage across the cavity gap. To quench superconductivity in an SRF cavity, it is reported that the limit of the peak magnetic-field is 1800G [1], and that of the peak electric-field is more than 100MV/m for a SRF cavity [2]. Naturally, for the complex geometry of this cavity (including numerous electron beam welds) and 4.2K operations we do not expect record field performance, but a useful 2 MV gap voltage is reasonable to expect. Our simulations employed the codes Superfish and Microwave Studio.

43 PARTICLE ACCELERATORS↗

Continuous Energy Neutron Cross Section Data Tables Based upon ENDF/B-VII.1

In December 2011, the National Nuclear Data Center (NNDC) released ENDF/BVII.1, the “latest recommended evaluated nuclear data file for use in nuclear science and technology applications”. The data was released in the standard Evaluated Nuclear Data Format (ENDF). This release represents the advances made in nuclear data during the five years since the release of ENDF/B-VII.0. The Nuclear Data Team at Los Alamos National Laboratory has processed the ENDF/B-VII.1 library and has made available a library of ACE data tables at several temperatures for each of the ENDF/B files. The ACE data library is called ENDF71x.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Technical Letter Report Development of Flaw Size Distribution Tables Including Effects of Flaw Depth Sizing Errors for Draft 10CFR 50.61a (Alternate PTS Rule) JCN-N6398, Task 4

This document describes a new method to determine whether the flaws in a particular reactor pressure vessel are consistent with the assumptions regarding the number and sizes of flaws used in the analyses that formed the technical justification basis for the new voluntary alternative Pressurized Thermal Shock (PTS) rule (Draft 10 CFR 50.61a). The new methodology addresses concerns regarding prior methodology because ASME Code Section XI examinations do not detect all fabrication flaws, they have higher detection performance for some flaw types, and there are flaw sizing errors always present (e.g., significant oversizing of small flaws and systematic under sizing of larger flaws). The new methodology allows direct comparison of ASME Code Section XI examination results with values in the PTS draft rule Tables 2 and 3 in order to determine if the number and sizes of flaws detected by an ASME Code Section XI examination are consistent with those assumed in the probabilistic fracture mechanics calculations performed in support of the development of 10 CFR 50.61a.

Fabrication Flaws Density and Distribution in RPVs↗