Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “System control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Assessment of the High Flux Isotope Reactor Cybersecurity Initiative

Recent cyber-attacks on industrial control systems, and inadvertent exposure of nuclear plant systems to cyber-exploits underscore the need for plant operators to adopt and deploy cyber-security defense solutions made for industrial control systems. Of increasing concern is the fact that international cyber hackers are beginning to target critical infrastructure, and because these more modern controls systems depend on advanced use of digital systems, they are more vulnerable than ever before to cyber-attacks. Traditional cyber defense strategies and products that have been available for decades are tailored for use on IT or corporate networks but can cause interruptions and catastrophic damage when deployed on industrial control system networks. The Department of Energy (DOE) Office of Nuclear Energy established the Gateway for Accelerated Innovation in Nuclear (GAIN) program to provide private companies pursuing innovative nuclear energy technologies with access to the technical support necessary to move toward commercialization. One of these GAIN small business vouchers was awarded to Dragos, Inc. to enable collaboration with Oak Ridge National Laboratory (ORNL) to evaluate the Dragos Platform on a production nuclear reactor test bed, hence laying the path for future commercial adoption. The vision was to provide a guide for industrial operators on implementing an industrial monitoring solution and to show how these solutions can be deployed without causing safety and reliability issues. This report documents the results of the collaboration between ORNL and Dragos, Inc.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dynamic Performance Enhancement for Nonlinear Stochastic Systems Using RBF Driven Nonlinear Compensation with Extended Kalman Filter

In this paper, a novel hybrid control method is proposed to enhance the control performance of the PI based control system for a class of nonlinear and non-Gaussian stochastic dynamic processes with unmeasurable states. Firstly, to enhance the tracking performance of the PI controller where the PI parameters are fixed in many actual control systems, the compensative signal is formed using the extended Kalman filter(EKF) based state estimator and driven by the radial basis function (RBF) neural network based compensator. In addition, the weights of RBF is trained to minimize the entropy criterion of tracking error as the process is subjected to non-Gaussian disturbances. Meanwhile, since the precise statistical property of noises is hard to obtain for many industrial processes, the kernel density estimation (KDE) technique is employed in this paper to estimate the entropy. The convergence of RBF network is discussed and the stability of the resulted closed-loop hybrid control system is analyzed in mean square sense. Finally, a numerical example and a practical system testing are given to illustrate the effectiveness of the proposed control method.

stochastic systems, PI Controller, Entropy, Extend↗

PELICAN Design, Test Planning, and Commissioning Results

To support design efforts for the Versatile Test Reactor (VTR) core assemblies, an experimental facility has been designed and constructed at Argonne National Laboratory to match the hydraulic flow conditions within the VTR’s primary heat transport system (PHTS). This facility, the Pressure drop Experimental Loop for Investigations of Core Assemblies in advanced Nuclear reactors, PELICAN, provides the ability to measure pressure drop across a full-scale fuel assembly containing prototypic axial reflectors, fuel, and plena components. The PELICAN facility was designed and built to offer maximum flexibility, allowing testing from short sub-sections all the way to the full-length core fuel assemblies. The report presents the high-level program objectives, a summary of the facility design, instrumentation, and control systems, and the testing procedure. The outcomes from facility characterization efforts and first test matrix results are then presented and then, finally, the conclusion contains a summary of the future work to be performed. This test facility was designed to match the hydraulic conditions of the flowing sodium in the VTR using water as a surrogate fluid. To do so, the water is elevated to a temperature of 110°C where its viscosity matches that of sodium, and with a 50-HP centrifugal pump, is capable of generating full scale flow rates to achieve prototypic Reynolds and Euler number flow conditions. To prevent boiling, the system is maintained at elevated pressure of at least 2.7-3.0 bar (40-44 psig). A set of 15 tests have been used to perform checkout activities in order to commission the device, survey the capabilities of PELICAN, and generate experimental data at isothermal conditions and over a range of flow rates up to 44 kg/s (700 GPM) to produce datasets used in the verification and validation of VTR design and modeling efforts. Initial testing focused on facility characterization, which assessed the operational capabilities of various control systems. The thermal control system was qualified, including the thermal response of the loop to the heat added by self- and auxiliary heaters, the chiller and heat exchanger systems for removing excess heat, and their coupled ability to maintain steady-state isothermal conditions as desired. Additionally, the pressure control system was verified to ensure necessary operating environments that promote pump health and prevent boiling of loop inventory at high temperatures could be met. With these systems in place, the first set of matrix tests have been carried out using orifice plates with inner diameters of 2.25-inches and 2.5-inches. Orifice plate flow behavior is well covered in scientific literature, and the results find good agreement with the measured pressure drop vs flow rate and those of theoretical predictions. This initial testing not only helps to validate the experiment, but it also produces a high quality data set for a geometry that is easily reproducible for simulations. Finally, the report is concluded with a discussion of the work to come and provides a snapshot of the test articles in the experimental pipeline whose designs are being inspired by the current designs from the VTR.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Adaptive controller for forced oscillation suppression in the grid

A control system and method for an inverter-based resource device provided in a synchronous power grid. The control system includes at least one inverter based resource device connected to an electrical power system, and a controller module. The inverter based resource device includes a reference power Pref, a combination module and a transfer function. The inverter based resource device injects modulated power into the power system. The power system (which is represented by a transfer function in the control system) receives an undesirable forced oscillation, which is connected to a measuring device. A controller module processes the measured output and provides a control signal to the inverter based resource device. The controller is arranged to suppress a forced oscillation detected in the power system.

Guttromson, Ross↗

A Data-Driven Voltage Control Strategy for Distribution Grids With Distributed Energy Resources

Traditionally, distribution system control approaches have been model-based. The deployment of advanced metering infrastructure has provided electric utilities with the capability of data-driven control with real-time measurements. The shift from model-based to data-driven control represents a significant advancement in the management of distribution systems, offering a more adaptive approach to system control because of the ability to dynamically adapt to changing conditions without the need for system modeling. Here, in this paper, a behavioral data-driven control method is developed to provide voltage regulation to an actual distribution system by controlling the legacy devices and distributed energy resource (DER) assets. The studied distribution system has a load tap changer and three capacitor banks as the legacy devices and photovoltaic systems as the DERs. The performance of the proposed control algorithm is validated using a laboratory test bed setup considering multiple scenarios. The results show that the proposed control achieved 99% voltage regulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency threshold determination for frequency-responsive load controllers

Systems, methods, and computer media for managing frequency response in a power grid are provided herein. Individual grid-connected electrical devices can be turned on and/or off by corresponding frequency-responsive load controllers when frequency deviations beyond a threshold are detected. Each controller selects, for the corresponding electrical device, a frequency threshold from available frequencies in a frequency range. If the selected frequency falls within a deadband frequency range, then the controller sets the frequency threshold to a frequency outside of the deadband (e.g., to a closest available frequency outside of the deadband). On a system-wide level, this approximates a uniform distribution of frequency thresholds over the entire frequency range, including the deadband, and achieves the proper power-to-frequency relationship for grid stability. A supervisory coordinator can determine the frequency range from which a frequency threshold is selected based on aggregated power information for devices and controllers throughout the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Renewable energy integration and system operation challenge: control and optimization of millions of devices

The electric power infrastructure, originally designed and built on large-scale power plants, is evolving into a more resilient power generation and delivery system in which millions of smaller units of distributed energy generation resources units will be installed in sub-transmission and distribution networks. In order to control, manage and optimize the future grid, a hierarchical design is presented in this chapter which enables the distributed control on grid edge while inheriting the existing centralized control structure. This layered design of large-scale power system operation and control uses the following principle: reactive power control is treated as a primary control for voltage stability, and the real power control is primarily a grid-level control but can also be a supplementary control for voltage support in the case of insufficient reactive power control capacity. For the purpose of active control and operation at the distribution level, a recursive power network model is derived from nodal injection and branch power flow models. Based on the model, the proposed algorithms of hierarchical control, grid-edge inference and dynamic hosting allowance are developed and presented for multi-level controlled operation. And, a co-simulation architecture of integrated T&D system is presented to validate and demonstrate the feasibility and scalability of proposed algorithms.

Xu, Ying↗

A system to control CO2 in O2 concentrations in aqueous media (Year 2 Report)

Per the Statement of Work, the following tasks were outlined for completion in Year 2: 1). Testing, modification, and optimization of the system. 2). Addition of oxygen manipulation and monitoring. 3). Expansion of CO2 bubbling/pH reduction system to include oxygen addition/removal and temperature control. 4). Investigate alkalinity modification by the microbial cultures and its impact on the carbonate chemistry control of the system. 5).Deliverable: Seawater chemistry and temperature control and monitoring system for microbial culture studies under present and future ocean conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Autonomous System Inference, Trojan, and Adversarial Reprogramming Attack and Defense (Final)

In the world of ever-advancing technology, Autonomous Systems (AS) find extensive application, bolstering functionalities of critical infrastructures such as nuclear power plants. These systems, however, are increasingly becoming a target for nefarious activities, namely through inference attacks, trojan attacks, and adversarial reprogramming. This paper delves into a comprehensive exploration of machine learning (ML)-driven autonomous control systems within advanced nuclear reactor designs, revealing the vulnerabilities and proposing strategies for defense against potential cyber-attacks. Advanced cyber-attacks against critical infrastructure and the energy sector are becoming more common. With the invention of autonomous control systems (ACS) within advanced nuclear reactor designs, system designers, reactor operators, and regulators must consider cybersecurity during the design and operational phases. This article provides a cyber threat assessment of machine learning (ML)- based digital twinning (DT) technologies in the context of advanced reactor ACS. A cyber-physical testbed was created to emulate nuclear reactor digital instrumentation and controls (I&C) and act as a basis for the ACS. The ACS was designed as two plant-level DTs predicting reactor malfunctions and determining control actions and two component-level DTs responsible for classifying component states and forecasting component inputs and outputs (I/O). Two duplicate ACS designs– one using a traditional ML framework and one using an automated ML (AutoML) framework– were created and tested against cyber-attacks on training data, real-time process data, and ML model architectures to determine their respective qualitative cyber-risk in terms of likelihood and impact. Both frameworks showed similar cyber-resilience against training, real-time, and ML architecture attacks, proving that neither is inherently more secure. Recommended safeguard and security measures are posed to system designers, reactor operators, and regulators to maintain the cybersecurity of ML-based DT technologies such as ACS, prompting a holistic view of shared responsibility for maintaining cyber-secure ML-based systems. As global reliance on generation III reactors begins to be critically assessed, the evolution towards advanced reactor systems utilizing digital instrumentation and controls (I&C) becomes not merely preferable, but essential. The integration of semi and fully autonomous control systems (ACS), powered by digital I&C and machine learning (ML)-based digital twinning (DT) technologies, emerges as a potent strategy to mitigate operations and maintenance costs, thereby enhancing the economic feasibility of novel reactor designs. However, with a staggering 500% and 380% increase in cyber-attacks reported against the energy sector by the United States Department of Energy (DoE) and the European Union respectively, a surge in cyber vulnerabilities specifically targeting the nuclear industry has been 2 markedly observed. Notable incidents, such as the W32.Ramnit spyware infiltration at the Gundremmingen nuclear power plant in Germany and the Dtrack spyware intrusion at the Kudankulam nuclear power plant in India, while not directly compromising core industrial control systems (ICS), underscore a compelling necessity to fortify cybersecurity protocols in safeguarding reactor systems against increasingly adept digital adversaries. In light of this, our investigation extends beyond conventional cybersecurity parameters, diving into the intricate web of potential vulnerabilities woven into ML-based DTs and ACS in advanced reactor systems. A crafted cyber-physical testbed and preliminary ACS were devised to act as a mirror, reflecting potential configurations of advanced reactor control designs. Moreover, this study is intertwined with a scrutinization of ML models, developed either through conventional, manually tuned methodologies or via automated means through AutoML, probing into their cyber-risk profiles within operational technology (OT) environments. Expanding on this, two distinct ACS blueprints were forged – one navigating through the corridors of traditional ML and the other traversing the path of AutoML – in an effort to holistically encapsulate the considerations pivotal to ML-based DT control system design. Employing the SANS Institute Industrial Control System (ICS) Kill Chain and the MITRE ATT&CK Tactics, Techniques, and Procedures (TTP) framework, a structured analysis was conducted, launching three targeted attacks against the training dataset, real-time dataset, and ML models, therein dissecting the potential cyber-attack implications against both ML frameworks within an ACS milieu. It is essential to note that three distinct categories of attacks were conducted against both ACS configurations, each encompassing three distinct ML-based DTs, cumulating in a total of 18 varied attacks. This exploration extends into the realms of Autonomous System Inference, Trojan, and Adversarial Reprogramming Attack and Defense, unraveling vulnerabilities, and opportunities for fortified defenses against such intrusions, particularly where ML-driven technologies, and by extension, ACS, are deployed. Final recommendations, articulated through a lens of security, safeguard, and implementation considerations, are presented for both traditional and AutoML models, anchoring upon the existing knowledge landscape and ML-based DT modeling for ACS, and are offered as a beacon to guide the nuclear industry through the intricate cybersecurity challenges that lie ahead.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Tangible Solutions for Grid Operation Upgrade

Many countries worldwide are setting clean energy targets to decarbonize the energy sector and add higher wind and solar capacities. Given their distributed nature, variable renewable energy (VRE) assets can have unique grid integration considerations, and require grid operation practices to be modernized. When transitioning to higher renewable energy levels, many system operators configure a dedicated renewable energy desk to manage renewable energy resource operation in the system control center. Further, system operation planning is conducted with VRE and load forecasting to enable reliable real-time system operation. NREL has partnered with many system operators in the region to identify appropriate technology and grid modernization solutions. NREL and partners from system operators in the region will present on the challenges and some solutions that have been applied and share best practices such as energy management system upgrades, VRE forecasting framework, grid flexibility improvements, and staff training.

emerging economies↗

Advanced Reactor Safeguards & Security Program: Cybersecurity Scenarios

The use of digital control systems and automation in advanced nuclear power systems introduces different types of vulnerabilities compared to legacy (i.e. analog) control systems that cyber adversaries can exploit. These vulnerabilities pose a challenge to reactor operators and cyber operations staff due to the dynamic nature of the event in which a human response or a lack of response can potentially evolve into a worsening plant condition. Using the Department of Homeland Security Cyber and Infrastructure Security Agency’s (CISA) critical infrastructure exercise framework, this document presents several cyber security scenarios typical of digital control systems that could be used in advanced reactor designs. These scenarios can be used in tabletop exercises to evaluate cyber security posture or conduct training on different aspects of cyber security, including detection, threat hunting using indicators of compromise, evaluating incident response, risk mitigation, incident reporting, information sharing and recovery.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modular thermal and radiation shielding with passive heat removal

A housing assembly configured to house a reactor is disclosed. The housing assembly includes a plurality of modular walls configured to surround the reactor and a passive temperature control system. The plurality of modular walls includes a first modular wall. The passive temperature control system is coupled to the first modular wall. The passive temperature control system is configured to transfer heat between the reactor and an area around the housing assembly.

Trupiano, Anthony G.↗

Enhancing the Operational Resilience of Advanced Reactors with Digital Twins by Recurrent Neural Networks

Because of a lack of operational data and uncertainty in evaluation model for abnormal and accident scenarios, the established operating procedures can be biased in characterizing the reactor states and ensuring operational resilience. To reduce uncertainty associated with actual plant conditions, digital twin (DT) technology is suggested to support operator’s decision-making by effectively extracting and using knowledge of the current and future plant states from the knowledge base. This study first builds a knowledge base based on the characterization of issue space and the simulation tool. Next, this study discusses diagnosis and prognosis DTs for enhancing operational resilience by recovering the complete states of reactors and by predicting the future reactor behaviors. Finally, the decision-making module of the control system can determine the optimal control strategy that meets operational goals during loss-of-flow scenarios. To demonstrate and evaluate the DTs capability for supporting the operations of nuclear reactors, this study develops and assesses both the diagnosis and prognosis DTs in a nearly autonomous management and control system for an Experimental Breeder Reactor-II simulator during different loss-of-flow scenarios.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Real-Time Defect Correction in Large-Scale Polymer Additive Manufacturing via Thermal Imaging and Laser Profilometer

Defects can result in a failed part and are costly in terms of time and material. This cost is even greater in the context of large-scale additive manufacturing where the objects can be very large. As a result, a great deal of research has focused on defect identification and mitigation. To address defects during object construction, researchers at Oak Ridge National Laboratory’s Manufacturing Demonstration Facility investigated an in-situ control system comprised of two sensors: a thermal camera and laser profilometer. This control system adjusted material flow and build speed to mitigate three types of defects: low layer times, underfill, and overfill. Several test objects were constructed. The control system was found to adjust build parameters to handle low layer times of approximately 15 seconds and height deviations from -100% underfill (the absence of a layer) to 50% overfill. Within two layers, height deviations could be returned to within 10% of the expected layer height. Further, preliminary results suggest the system can compensate for uneven build surfaces.

Borish, Michael↗

Scalable, Physical Effects Measurable Microgrid for Cyber Resilience Analysis (SPEMMCRA)

The ability to advance state of the art automated protections for industrial control systems (ICS) has as a precursor in the ability to understand the tradeoff space. That is, to enable a cyber feedback loop in a control system environment you must first consider both the security mitigation available, the benefits and the impacts to the control system functionality when the mitigation is used. More damaging impacts could be precipitated that the mitigation was intended to rectify. This paper details networked ICS that controls a simulation of the frequency response represented with the swing equation. The microgrid loads and base generation can be balanced through the control of an emulated battery and power inverter. The simulated plant, which is implemented in Raspberry Pi computers, provides an inexpensive platform to realize the physical effects of cyber attacks to show the tradeoffs of available mitigatoins. This network design can include a commercial ICS controller to introduce real world implementation of feedback controls, and provides a scalable, physical effects measurable Microgrid for cyber resilience analysis (SPEMMCRA).

42 ENGINEERING↗

Guest Editorial: Advanced Data-Analytics for Power System Operation, Control, and Enhanced Situational Awareness

Along with the smart grid development, modern power systems are entering a ‘data-intensive’ era. A vast volume of data from power grids is being collected through advanced sensing and communication technologies, such as smart metering data, phasor measurement data, as well as meteorological data (e.g., wind speed and solar irradiance) related to renewable power generation. Such data contains comprehensive information about the power system covering equipment's health status, power grid's static and dynamic characteristics, renewable power generation, customers’ electricity usage pattern, etc. Therefore, advanced data-analytics techniques are needed to convert such data to knowledge for practical applications. In line with the trend of widespread data-driven applications in power systems, this Special Issue aims to present state-of-the-art research works on advanced data-analytics for power system's operation, control, and situational awareness. There are in total twenty-six papers accepted for publication in this Special Issue through careful peer reviews and revisions. Under the overarching theme of data-driven applications in power systems, the selected papers are broadly categorised into five topics. The summary of every topic is given below. You are, however, strongly encouraged to read the full paper if interested.

Xu, Yan↗

Cryogenic Performance of the SPT-SLIM Receiver

The South Pole Telescope Shirokoff Line Intensity Mapper (SPT-SLIM) is a millimeter-wave line-intensity mapping experiment, deployed on the South Pole Telescope (SPT) during the 2024-2025 Austral Summer season. This pathfinder experiment serves to demonstrate the on-sky operation of multi-pixel on-chip spectrometer technology. We present on the cryogenic performance of the SPT-SLIM receiver for this Year 1 observing campaign. The SPT-SLIM receiver utilizes an Adiabatic Demagnetization Referigerator (ADR) for cooling the focal plane of superconducting filterbank spectrometers to a temperature of 150mK. We demonstrate stable thermal performance of the focal plane module during observing operations in line with thermal modelling, enabling a cryogenic operation efficiency above 80%. We also report on the receiver control system design utilizing the Observatory Control System (OCS) platform for automated cryogenic operation on the SPT.

Young, Matthew [Fermilab]↗

Design and Performance of the SPT-SLIM Receiver Cryostat

The South Pole Telescope Shirokoff Line Intensity Mapper (SPT-SLIM) is a millimeter-wavelength line-intensity mapping experiment, which was deployed on the South Pole Telescope (SPT) during the 2024-2025 Austral summer season. This pathfinder experiment serves to demonstrate the on-sky operation of multi-pixel on-chip spectrometer technology. We report on the cryogenic performance of the SPT-SLIM receiver for the first year of commissioning observations. The SPT-SLIM receiver utilizes an Adiabatic Demagnetization Refrigerator (ADR) for cooling the focal plane of superconducting filterbank spectrometers to a temperature of 150 mK. We demonstrate stable thermal performance of the focal plane module during observations consistent with thermal modeling, enabling a cryogenic operating efficiency above 80%. We also report on the receiver control system design utilizing the Observatory Control System (OCS) platform for automated cryogenic operation on the SPT.

Young, M. R. [Fermilab; Chicago U., KICP]↗