Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Active Storage with Analytics Capabilities and I/O Runtime System for Petascale Systems

Computational scientists must understand results from experimental, observational and computational simulation generated data to gain insights and perform knowledge discovery. As systems approach the petascale range, problems that were unimaginable a few years ago are within reach. With the increasing volume and complexity of data produced by ultra-scale simulations and high-throughput experiments, understanding the science is largely hampered by the lack of comprehensive I/O, storage, acceleration of data manipulation, analysis, and mining tools. Scientists require techniques, tools and infrastructure to facilitate better understanding of their data, in particular the ability to effectively perform complex data analysis, statistical analysis and knowledge discovery. The goal of this work is to enable more effective analysis of scientific datasets through the integration of enhancements in the I/O stack, from active storage support at the file system layer to MPI-IO and high-level I/O library layers. We propose to provide software components to accelerate data analytics, mining, I/O, and knowledge discovery for large-scale scientific applications, thereby increasing productivity of both scientists and the systems. Our approaches include 1) design the interfaces in high-level I/O libraries, such as parallel netCDF, for applications to activate data mining operations at the lower I/O layers; 2) Enhance MPI-IO runtime systems to incorporate the functionality developed as a part of the runtime system design; 3) Develop parallel data mining programs as part of runtime library for server-side file system in PVFS file system; and 4) Prototype an active storage cluster, which will utilize multicore CPUs, GPUs, and FPGAs to carry out the data mining workload.

97 MATHEMATICS AND COMPUTING↗

Low-Cost Metal Hydride Thermal Energy Storage System for Concentrating Solar Power Systems

The objective of this research was to evaluate and demonstrate a metal hydride-based TES system for use with a CSP system. A unique approach has been applied to this project that combines our modeling experience with the extensive material knowledge and expertise at both SRNL and Curtin University (CU). Because of their high energy capacity and reasonable kinetics many metal hydride systems can be charged rapidly. Metal hydrides for vehicle applications have demonstrated charging rates in minutes and tens of minutes as opposed to hours. This coupled with high heat of reaction allows metal hydride TES systems to produce very high thermal power rates (approx. 1kW per 6-8 kg of material). A major objective of this work is to evaluate some of the new metal hydride materials that have recently become available. A problem with metal hydride TES systems in the past has been selecting a suitable high capacity low temperature metal hydride material to pair with the high temperature material. A unique aspect of metal hydride TES systems is that many of these systems can be located on or near dish/engine collectors due to their high thermal capacity and small size. The primary objective of this work is to develop a high enthalpy metal hydride that is capable of reversibly storing hydrogen at high temperatures (> 650 °C) and that can be paired with a suitable low enthalpy metal hydride with low cost materials. Furthermore, a demonstration of hydrogen cycling between the two hydride beds is desired.

25 ENERGY STORAGE↗

Impact of Distributed Energy Resources on the Bulk Electric System: Combined Modeling of Transmission and Distribution Systems and Benchmark Case Studies

The high penetration of distributed energy resources (DERs) on modern distribution systems introduces intermittent power generation, stochastic system operating conditions, and bi-directional power flows that impact the system responses to various types of disturbances and may pose challenges to the operations and reliability of the Bulk Electric System (BES). In order to understand the impact of DERs on the planning and operation of the BES, the distribution system can no longer be represented as a single load at a node on the transmission system. At the same time, advanced control capabilities of DERs offer potential opportunities for improving BES reliability by transforming DERs from a passive “do no harm” resource to an active “support reliability” resource when applied in a planned and well-thought-out manner. This concept is often described as DER “flexibility.” With the persistent trend towards a high- penetration of DERs in distribution systems, regulators such as the North American Electric Reliability Corporation (NERC), planning coordinators and grid operators are in serious need of understanding the full-spectrum impact of DERs on the BES to ensure secure and reliable grid planning and operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

AOI [1]: Passive Wireless Sensor Systems Fabricated by Direct-Writing for Temperature and Health Monitoring of Energy Systems in Harsh-Environments (Final Report)

Researchers at West Virginia University (WVU) propose to demonstrate a wireless, high-temperature sensor system for monitoring the temperature and health of energy-system components. The active sensor and electronics for wireless communication will be composed entirely of an electroceramic materials (conductive ceramics) which are capable of withstanding the harsh-environments required for fossil energy-based technologies. This work will focus primarily on the fabrication and testing of temperature (thermocouples and thermistors) and health (strain/stress and crack propagation sensors) that function at extreme temperatures (up to 700-1700ºC). The electronics will accompany the high-temperature sensor, which will include a passive wireless communication circuit that allows the transmission of the data based on the LCR resonance principle to a near-by reader antenna. This passive transmission of data will reduce the need for interconnect wires near the active, and possibly rotating, energy-system component. The research will include process development to permit the 2D/3D direct-writing of the entire sensor and communication circuit onto the energy-system component. The direct-writing will be facilitated by using silicon-based polymer-derived precursors to form the high-temperature, stable electroceramic compositions. In addition, methods for direct-writing the circuit onto a fugitive carrier substrate will be completed, which will permit a “peel-and-stick”-like transfer of the sensor circuit to the energy-system component. This feature will allow the economical and precise placement of the sensor circuit onto components of various shapes and locations, without altering the geometry and active features of the manufactured component, or the removal (or decommissioning) of the component for installation. The proposed work will be directed at the following areas: 1) Investigation of phase formation, sintering/grain growth, and electrical properties of polymer-derived electroceramic composites; 2) Definition of processes to direct-write through ink-jet and robo-casting the polymer-derived electroceramic composites onto oxide and polymer surfaces; 3) Development of methods to form monolithic "peel-and-stick" preforms that will efficiently transfer the sensor circuit to ceramic surfaces after thermal treatment; 4) Design of passive wireless LCR circuits and receiver (reader) antennas for communication and testing at high temperatures; 5) Investigation of the passive wireless sensor system developed (and method of transferring sensor system) for temperature and stress/strain measurements on a SOFC repeat unit and a singular gas turbine blade prototype as example applications.

01 COAL, LIGNITE, AND PEAT↗

Verification Testing of OLI Systems Mixed Solvent Electrolyte Model for the Na-K-Mg-Ca-H-Cl-SO 4 -OH-HCO 3 -CO 3 -CO 2 -H 2 ) System to High Ionic Strength at 25°C

This technical report summarizes model verification results and summary statistics for 41 evaporite mineral solubility cases evaluated by Savannah River National Laboratory using OLI Systems’ aqueous electrolyte thermodynamic modeling software. The 41 verification cases containing a total of 60 solubility curves comprise mineral solubility data from low to high ionic strength at 25°C for the eight-component system Na-K-Mg-Ca-H-Cl-SO 4 -OH-HCO 3 -CO 3 -CO 2 -H 2 O as reported by Harvie et al. (1984). Thermodynamic calculations were executed using OLI Systems’ Stream Analyzer computation module within the OLI Studio software platform (Ver. 11.0, Rev. 11.0.1.9). The Mixed Solvent Electrolyte (MSE) thermodynamic framework was chosen for this investigation because of its superiority in modeling high ionic-strength inorganic salt solutions and actinide redox chemistry and solubility, both of which are relevant to the geological repository conditions at the Waste Isolation Pilot Plant in Carlsbad, New Mexico. Mineral solubility data in various inorganic salt solutions were digitized and extracted from figures generated by Harvie et al. (1984). For each of the 60 solubility curves, a case-specific chemistry model and input file were generated in OLI Studio using OLI Stream Analyzer and the MSE (H 3 O + ion) public databank provided by OLI Systems. Model simulation results were exported to Microsoft Excel to calculate summary statistics and to generate graphs comparing the OLI model predictions to the solubility data. Summary statistics include residuals (model – data) and concordance (accuracy × precision, where precision is indicated by the Pearson correlation coefficient and accuracy accounts for bias and scale differential). Private databanks were not developed, and activity coefficient model regressions were not performed to improve OLI model fits to the data. Of the 41 model verification plots, 83% have a mean of the percent residuals less than or equal to 25%. Similarly, 75% display a concordance greater than or equal to 0.75. Only seven of the 41 verification plots fail to show good agreement between the model and data. Of these seven, three are relevant to the WIPP repository because they involve the Mg-OH-Cl-SO 4 -CO 3 aqueous system. The remaining four address salt solubilities at the pH extremes (strong acid and strong base). It should be noted that in two of the three Mg-OH-Cl-SO 4 -CO 3 system cases, the regressed Harvie et al. (1984) solubility curve also deviated from the data. Lack of agreement between the OLI model-predicted solubility curves and the data is attributable to one or more of the following: specific solid species are not included in the OLI MSE databank; there is significant variation among the different solubility datasets chosen by Harvie et al. (1984); the OLI MSE model’s thermodynamic parameters were determined using different solubility datasets; and the activity coefficient parameters for certain relevant ion-ion and ion-molecule pairs have not been optimized via data regression. Two recommendations for future work are to (1) evaluate solubility data for the Mg-OH-Cl-SO 4 -CO 3 system at high ionic strength and, if necessary, develop a private OLI MSE database that includes missing species and, where necessary, regressed standard state properties and interaction parameters; (2) perform similar verification testing of the OLI model for actinide solubility data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Microreactor Automated Control System - Digital Twin Models and Advanced Control Systems Updates

Automation of control systems is expected to be important in the economic and safe operation of microreactors. Therefore, there is a need to develop and demonstrate automated control for microreactors, along with the development of testbeds for this purpose. This report provides updates on the status of a nonnuclear microreactor automated control system (MACS)—a real-time, hardware-in-the-loop testbed for non-nuclear testing of microreactor control system automation. A real-time hardware-in-the-loop testbed incorporates the realistic dynamics of physical systems into control system development and testing. The collaborative effort between Oak Ridge National Laboratory (ORNL) and Idaho National Laboratory (INL) resulted in the development of a prototypic microreactor plant-level digital twin that includes the reactor and a balance of plant system. Advanced control strategies were incorporated to demonstrate testing of control automation solutions. The gRPC communication protocol, which was implemented in the hardware-in-the-loop testbed by INL, was coupled to a digital twin model developed using the TRANsient Simulation Framework of Reconfigurable Models (TRANSFORM) library in Modelica. This digital twin simulation was tested with the ViBRANT hardware for realistic feedback and visual representation of control action in real time. A modular Python client structure was developed to manage functional mock-up unit-based simulation and real-time gRPC communication. Hardware-in-the-loop testing indicated that the modeled reactor—a natural-convection, molten-salt coolant loop configuration—responds well to control of drum positioning for modulation of reactor core power, as well as system-level control and downstream demand changes. Ongoing research is focused on integrating additional control algorithms that utilize data from newly included sensors within the MACS hardware testbed, as well as demonstrating and assessing the performance of the different automated control algorithms on multiple additional operational scenarios.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Battery Energy Storage Systems: A Review of Energy Management Systems and Health Metrics

With increasing concerns about climate change, there is a transition from high-carbon-emitting fuels to green energy resources in various applications including household, commercial, transportation, and electric grid applications. Even though renewable energy resources are receiving traction for being carbon-neutral, their availability is intermittent. To address this issue to achieve extensive application, the integration of energy storage systems in conjunction with these resources is becoming a recommended practice. Additionally, in the transportation sector, the increased demand for EVs requires the development of energy storage systems that can deliver energy for rigorous driving cycles, with lithium-ion-based batteries emerging as the superior choice for energy storage due to their high power and energy densities, length of their life cycle, low self-discharge rates, and reasonable cost. As a result, battery energy storage systems (BESSs) are becoming a primary energy storage system. The high-performance demand on these BESS can have severe negative effects on their internal operations such as heating and catching on fire when operating in overcharge or undercharge states. Reduced efficiency and poor charge storage result in the battery operating at higher temperatures. To mitigate early battery degradation, battery management systems (BMSs) have been devised to enhance battery life and ensure normal operation under safe operating conditions. Some BMSs are capable of determining precise state estimations to ensure safe battery operation and reduce hazards. Precise estimation of battery health is computed by evaluating several metrics and is a central factor in effective battery management systems. In this scenario, the accurate estimation of the health indicators (HIs) of the battery becomes even more important within the framework of a BMS. This paper provides a comprehensive review and discussion of battery management systems and different health indicators for BESSs, with suitable classification based on key characteristics.

Nazaralizadeh, Solmaz (ORCID:0009000737004039)↗

Integrating Radio-Over-Fiber Communication System and BOTDR Sensor System

In this paper, we propose and experimentally demonstrate for the first time, the integration of a radio-over-fiber (RoF) communication system and a Brillouin optical time-domain reflectometry (BOTDR) distributed sensor system using a single optical fiber link. In this proof-of-concept integrated system, the communication system is composed of three modulation formats of quadrature phase-shift keying (QPSK), 16-quadrature amplitude modulation (16-QAM) and 64-QAM, which are modulated onto an orthogonal frequency division multiplexing (OFDM) signal. Whereas, the BOTDR sensor system is used for strain and/or temperature monitoring over the fiber distance with a spatial resolution of 5 m using a 25 km single-mode silica fiber. The error vector magnitude (EVM) is analyzed in three modulation formats in the presence of various BOTDR input pump powers. Using QPSK modulation, optimized 18 dBm sensing and 10 dBm data power, the measured EVM values with and without bandpass filter are 3.5% and 14.5%, respectively. The proposed system demonstrates a low temperature measurement error (±0.49 °C at the end of 25 km) and acceptable EVM values, which were within the 3GPP requirements. The proposed integrated system can be effectively applied for practical applications, which significantly reduces the fiber infrastructure cost by effective usage of a single optical fiber link.

42 ENGINEERING↗

The DES Bright Arcs Survey: Hundreds of Candidate Strongly Lensed Galaxy Systems from the Dark Energy Survey Science Verification and Year 1 Observations

We report the results of searches for strong gravitational lens systems in the Dark Energy Survey (DES) Science Verification and Year 1 observations. The Science Verification data span approximately 250 sq. deg. with a median i -band limiting magnitude for extended objects (10 σ ) of 23.0. The Year 1 data span approximately 2000 sq. deg. and have an i -band limiting magnitude for extended objects (10 σ ) of 22.9. As these data sets are both wide and deep, they are particularly useful for identifying strong gravitational lens candidates. Potential strong gravitational lens candidate systems were initially identified based on a color and magnitude selection in the DES object catalogs or because the system is at the location of a previously identified galaxy cluster. Cutout images of potential candidates were then visually scanned using an object viewer and numerically ranked according to whether or not we judged them to be likely strong gravitational lens systems. Having scanned nearly 400,000 cutouts, we present 374 candidate strong lens systems, of which 348 are identified for the first time. We provide the R.A. and decl., the magnitudes and photometric properties of the lens and source objects, and the distance (radius) of the source(s) from the lens center for each system.

79 ASTRONOMY AND ASTROPHYSICS↗

Reducing the Carbon Footprint of Commercial Refrigeration Systems Using Life Cycle Climate Performance Analysis: From System Design to Refrigerant Options

In this paper, Life Cycle Climate Performance (LCCP) analysis is used to estimate lifetime direct and indirect carbon dioxide equivalent gas emissions of various refrigerant options and commercial refrigeration system designs, including the multiplex DX system with various hydrofluorocarbon (HFC) refrigerants, the HFC/R744 cascade system incorporating a medium-temperature R744 secondary loop, and the transcritical R744 booster system. The results of the LCCP analysis are presented, including the direct and indirect carbon dioxide equivalent emissions for each refrigeration system and refrigerant option. Based on the results of the LCCP analysis, recommendations are given for the selection of low GWP replacement refrigerants for use in existing commercial refrigeration systems, as well as for the selection of commercial refrigeration system designs with low carbon dioxide equivalent emissions, suitable for new installations.

Fricke, Brian A↗

Characterization of Mechanical Ventilation Systems in New US Homes: What types of systems are out there and are they functioning as intended?

As the airtightness of homes improves to meet energy efficiency goals, it becomes more important for mechanical ventilation systems to help maintain a comfortable and healthy indoor air environment. ASHRAE Standard 62.2 provides national guidance for mechanical ventilation system design and installation, however adoption of those guidelines into local building codes has occurred at different rates. Once provisions for mechanical ventilation are adopted in a local code, are mechanical ventilation systems properly designed, installed, commissioned and operated according to code or above code program requirements? Is there a need for further industry and homeowner education to ensure systems function as intended? This paper presents results from field studies that include characterization of mechanical ventilation systems in over 150 new homes in CA, CO, FL, GA, IL, OR, and SC built between 2011 and 2018. In each of the study homes, airflow of local (kitchen, bathrooms) and whole-house ventilation were measured. Occupant usage of the mechanical ventilation systems were monitored for one week in each home. Installed performance is compared to inferred design intent. The paper also includes homeowner perceptions about, and interactions with, the installed mechanical ventilation systems.

Martin, Eric↗

A Vector Control and Data Acquisition System for the Multicavity LLRF System for Cryomodule1 at Fermilab

A LLRF control and data acquisition system for the 8-cavity Cryo-Module 1 at the ILCTA has been implemented using three , 33-channel MFC boards in a VXI mainframe. One card each is dedicated for the cavity probes for vector control , forward power and reverse power measurements. The system is scalable to 24 cavities or more with the commissioning of Cryo-Modules 2 and 3 without additional hardware. The signal processing and vector control of the cavities is implemented in a FPGA and a high speed data acquisition system with upto 100 channels stores data in external SDRAM memory. The system supports both pulsed and CW modes with a pulse rate of 5Hz. Acquired data is transferred between pulses to auxiliary systems such as the piezo controller through the slot0 controller. The design of the system is described and the performance of the vector control system is evaluated.

43 PARTICLE ACCELERATORS↗

System and method for reasoning about the optimality of a configuration parameter of a distributed system

Embodiments provide a system and method for reasoning about the optimality of a configuration parameter of a distributed system. During operation, the system obtains a multi-layer graph for a system with a plurality of components, wherein the multi-layer graph comprises a configuration subgraph, a vulnerability subgraph, and a dependency subgraph. The system determines, based on the multi-layer graph, constraint relationships associated with configuration parameters for the components, wherein the constraint relationships include security constraints and functionality constraints. The system computes an unsatisfiable core which comprises a set of mutually incompatible constraints. The system resolves, based on a strategy and over multiple iterations, the unsatisfiable core by analyzing one pair of mutually incompatible constraints per a respective iteration, to obtain a new unsatisfiable core which comprises a smaller number of mutually incompatible constraints than the computed unsatisfiable core or a previously computed unsatisfiable core from a most recent iteration.

Soroush, Hamed↗

Warm Compressor system Overview and status of the PIP-II cryogenic system

The Proton Improvement Plan-II (PIP-II) is a major upgrade to the Fermilab accelerator complex, featuring a new 800-MeV Superconducting Radio-Frequency (SRF) linear accelerator (Linac) powering the accelerator complex to provide the world's most intense high-energy neutrino beam. The PIP-II Linac consists of 23 SRF cryomodules operating at 2 K, 5 K, and 40 K temperature levels supplied by a single helium cryoplant providing 2.5 kW of cooling capacity at 2.0 K. The PIP-II cryogenic system consists of two major systems: a helium cryogenic plant and a cryogenic distribution system. The cryogenic plant includes a refrigerator cold box, a warm compressor system, and helium storage, recovery, and purification systems. The cryogenic distribution system includes a distribution box, intermediate transfer line, and a tunnel transfer line consisting of modular bayonet cans which supply and return cryogens to the cryomodules. A turnaround can is located at the end of the Linac to turnaround cryogenic flows. This paper describes the layout, design, and current status of the PIP-II cryogenic system.

43 PARTICLE ACCELERATORS↗

Systems and Tools to Facilitate Aging Management Inspections of Used Nuclear Fuel Dry Storage Systems - 18382

The Used Nuclear Fuel (UNF) dry storage systems (DSSs) are currently used at almost all the nuclear plants in the USA for the storage of their UNF as the spent fuel pools are running out of capacity to store any additional discharged fuel. Even though these DSSs are supposed to be at the reactor site for a short amount of time, they are expected to be at the reactor sites for an extended duration due to the unavailability of Interim Storage Facilities (ISF) or a permanent disposal sites like Yucca Mountain. Maintaining the integrity of the DSS canisters and storage overpacks so they can safely protect the fuel and maintain the integrity of UNF is of utmost importance during storage at reactor site ISFSI or at the ISF. Comprehensive and robust Aging Management Program (AMP) is an important aspect for DSSs to satisfy these requirements. In order to address this industry need, TN Americas have developed an enhanced NUHOMS{sup R} DSS licensed by NRC under 10 CFR Part 72 regulations and a comprehensive AMP development which includes prevention, inspection, monitoring and mitigation of any corrosion or degradation of DSS components. For DSC and HSM inspection, two remotely operating delivery systems have been developed using non-destructive examination (NDE) methods including robotic crawler and inspection ring system. This paper describes details of these developments and status of their deployment for implementation at various utility ISFSI sites. TN Americas completed the detailed design of the DSC inspection system and conducted functional tests of the inspection system on a DSC mockup and the system is ready for deployment at any NUHOMS{sup R} ISFSI site. TN Americas is committed to offer the most robust and comprehensive AMP systems, tools and services to the industry to assure the safety of the deployed DSS at the utility sites. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

7th Annual Systems Biology Symposium: Systems Biology and Engineering

Systems biology recognizes the complex multi-scale organization of biological systems, from molecules to ecosystems. The International Symposium on Systems Biology has been hosted by the Institute for Systems Biology in Seattle, Washington, since 2002. The annual two-day event gathers the most influential researchers transforming biology into an integrative discipline investingating complex systems. Engineering and application of new technology is a central element of systems biology. Genome-scale, or very small-scale, biological questions drive the enigneering of new technologies, which enable new modes of experimentation and computational analysis, leading to new biological insights and questions. Concepts and analytical methods in engineering are now finding direct applications in biology. Therefore, the 2008 Symposium, funded in partnership with the Department of Energy, featured global leaders in "Systems Biology and Engineering."

10 SYNTHETIC FUELS↗

Dynamic assessment of urban economy-environment-energy system using system dynamics model: A case study in Beijing

Highlights: • We combine System Dynamics model and Geographic Information System to analyze the energy-environment-economy (3E) system both temporally and spatially, which explicitly explore the interaction of economics, energy, and environment and effects of the key influencing factors. • Beijing is selected as a case study. • Alternative scenarios, e.g., current, technology, energy and environment scenarios are explored and compared. • Simulation results shows that, current scenario is not sustainable; technology scenario is applicable to economic growth; environment scenario maintains a balanced path of development for long term stability. Economic development, accompanying with environmental damage and energy depletion, becomes essential nowadays. There is a complicated and comprehensive interaction between economics, environment and energy. Understanding the operating mechanism of Energy-Environment-Economy model (3E) and its key factors is the inherent part in dealing with the issue. In this paper, we combine System Dynamics model and Geographic Information System to analyze the energy-environment-economy (3E) system both temporally and spatially, which explicitly explore the interaction of economics, energy, and environment and effects of the key influencing factors. Beijing is selected as a case study to verify our SD-GIS model. Alternative scenarios, e.g., current, technology, energy and environment scenarios are explored and compared. Simulation results shows that, current scenario is not sustainable; technology scenario is applicable to economic growth; environment scenario maintains a balanced path of development for long term stability. Policy-making insights are given based on our results and analysis.

54 ENVIRONMENTAL SCIENCES↗

Overview of Systems Considerations for On-Board Chemical Hydrogen Storage

Recent advances in chemical hydrogen storage systems are reviewed. Factors impacting design and implementation of chemical hydrogen storage systems for on-board vehicular use are highlighted. The physical and chemical characteristics of chemical hydrogen fuels and their spent fuel counterparts are considered to provide guidance to future technology developers. Heat management, fuel stability, reactor design, and fuel morphology are examples of issues that must be considered for the future of chemical hydrogen storage systems.

ammonia borane↗