Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Strip”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

THE CONVERSION OF LATE-TYPE INTO EARLY-TYPE DWARF GALAXIES BY RAM-PRESSURE STRIPPING IN THE FORNAX CLUSTER

We put to the test the hypothesis that the Fornax cluster dwarf galaxies are mostly a relatively recently acquired population, of which the star-forming, late-type members are converted into quiescent, early-type ones by ram-pressure stripping while being on orbits that plunge inside the inner few hundred kiloparsecs of the cluster. We construct dynamical models with different anisotropy profiles for the dwarf galaxy population and show that only extremely radially anisotropic orbital distributions are in agreement with the available morphological, positional, and kinematical data, especially with the radially increasing late-to-early-type ratio. This corroborates the idea that the Fornax cluster dwarfs are an infall population and that environmental factors, in this case ram-pressure stripping, play a prominent role in converting late-type dwarfs into early-type ones.

79 ASTRONOMY AND ASTROPHYSICS↗

PROGENITOR DIAGNOSTICS FOR STRIPPED CORE-COLLAPSE SUPERNOVAE: MEASURED METALLICITIES AT EXPLOSION SITES

Metallicity is expected to influence not only the lives of massive stars but also the outcome of their deaths as supernovae (SNe) and gamma-ray bursts (GRBs). However, there are surprisingly few direct measurements of the local metallicities of different flavors of core-collapse SNe (CCSNe). Here, we present the largest existing set of host-galaxy spectra with H II region emission lines at the sites of 35 stripped-envelope CCSNe. We derive local oxygen abundances in a robust manner in order to constrain the SN Ib/c progenitor population. We obtain spectra at the SN sites, include SNe from targeted and untargeted surveys, and perform the abundance determinations using three different oxygen-abundance calibrations. The sites of SNe Ic (the demise of the most heavily stripped stars, having lost both H and He layers) are systematically more metal rich than those of SNe Ib (arising from stars that retained their He layer) in all calibrations. A Kolmogorov-Smirnov test yields the very low probability of 1% that SN Ib and SN Ic environment abundances, which are different on average by {approx}0.2 dex (in the Pettini and Pagel scale), are drawn from the same parent population. Broad-lined SNe Ic (without GRBs) occur at metallicities between those of SNe Ib and SNe Ic. Lastly, we find that the host-galaxy central oxygen abundance is not a good indicator of the local SN metallicity; hence, large-scale SN surveys need to obtain local abundance measurements in order to quantify the impact of metallicity on stellar death.

79 ASTRONOMY AND ASTROPHYSICS↗

TRANSPARENT HELIUM IN STRIPPED ENVELOPE SUPERNOVAE

Using simple arguments based on photometric light curves and velocity evolution, we propose that some stripped envelope supernovae (SNe) show signs that a significant fraction of their helium is effectively transparent. The main pieces of evidence are the relatively low velocities with little velocity evolution, as are expected deep inside an exploding star, along with temperatures that are too low to ionize helium. This means that the helium should not contribute to the shaping of the main SN light curve, and thus the total helium mass may be difficult to measure from simple light curve modeling. Conversely, such modeling may be more useful for constraining the mass of the carbon/oxygen core of the SN progenitor. Other stripped envelope SNe show higher velocities and larger velocity gradients, which require an additional opacity source (perhaps the mixing of heavier elements or radioactive nickel) to prevent the helium from being transparent. We discuss ways in which similar analysis can provide insights into the differences and similarities between SNe Ib and Ic, which will lead to a better understanding of their respective formation mechanisms.

79 ASTRONOMY AND ASTROPHYSICS↗

Tidal stripping as a test of satellite quenching in redMaPPer clusters

When dark matter haloes are accreted by massive host clusters, strong gravitational tidal forces begin stripping mass from the accreted subhaloes. This stripping eventually removes all mass beyond a subhalo's tidal radius, with unbound mass remaining in the vicinity of the satellite for at most a dynamical time t dyn. The N -body subhalo study of Chamberlain et al. verified this picture and pointed out a useful observational consequence: correlations between subhaloes beyond the tidal radius are sensitive to the infall time, tinfall, of the subhalo on to its host. We perform this correlation using ~160 000 red satellite galaxies in Sloan Digital Sky Survey redMaPPer clusters and find evidence that subhalo correlations do persist well beyond the tidal radius, suggesting that many of the observed satellites fell into their current host less than a dynamical time ago, tinfall < t dyn. Combined with estimated dynamical times tdyn ~3–5 Gyr and SED fitting results for the time at which satellites stopped forming stars, t quench ~6 Gyr, we infer that for a significant fraction of the satellites, star formation quenched before those satellites entered their current hosts. Finally, the result holds for red satellites over a large range of cluster-centric distances 0.1–0.6 Mpc h –1 . We discuss the implications of this result for models of galaxy formation.

79 ASTRONOMY AND ASTROPHYSICS↗

Interaction of Josephson Junction and Distant Vortex in Narrow Thin-Film Superconducting Strips

The phase difference between the banks of an edge-type planar Josephson junction crossing the narrow thin-film strip depends on wether or not vortices are present in the junction banks. For a vortex close to the junction this effect has been seen by Golod, Rydh, and Krasnov [Phys. Rev. Lett. 104, 227003 (2010)], who showed that the vortex may turn the junction into π type. It is shown here that even if the vortex is far away from the junction, it still changes the 0 junction to a π junction when situated close to the strip edges. Within the approximation used, the effect is independent of the vortex-junction separation, a manifestation of the topology of the vortex phase which extends to macroscopic distances of superconducting coherence.

36 MATERIALS SCIENCE↗

Numerical simulations of stripping effects in high-intensity hydrogen ion linacs.

Numerical simulations of H{sup -} stripping losses from blackbody radiation, electromagnetic fields, and residual gas have been implemented into the beam dynamics code TRACK. Estimates of the stripping losses along two high-intensity H{sup -} linacs are presented: the Spallation Neutron Source linac currently being operated at Oak Ridge National Laboratory and an 8 GeV superconducting linac currently being designed at Fermi National Accelerator Laboratory.

43 PARTICLE ACCELERATORS↗

Strip Detectors Processed on High-Resistivity 6-Inch Diameter Magnetic Czochralski Silicon (MCz-Si) Substrates

Tracking detectors for future high-luminosity particle physics experiments have to be simultaneously radiation hard and cost efficient. This paper describes processing and characterization of p^+ /n^-/n^+ (n-type silicon bulk) detectors made of high-resistivity Magnetic Czochralski silicon (MCz-Si) substrates with 6-inch wafer diameter. The processing was carried out on a line used for large-scale production of sensors using standard fabrication methods, such as implanting polysilicon resistors to bias individual sensor strips. Special care was taken to avoid the creation of Thermal Donors (TD) during processing. The sensors have a full depletion voltage of 120-150 V which are uniform over the investigated sensors. All of the leakage current densities were below 55 nA/cm^2 at 200 V bias voltage. A strip sensor with 768 channels was attached to readout electronics and tested in particle beam with a data acquisition (DAQ) similar to the system used by the CMS experiment at the CERN LHC. The test beam results show a signal-to-noise ratio greater than 40 for the test beam sensor. The results demonstrate that MCz-Si detectors can reliably be manufactured in the industrial scale semiconductor process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Seismic strengthening of stone masonry walls with glass fiber reinforced polymer strips and mechanical anchorages

This paper presents a strengthening technique for traditional load-bearing stone masonry walls. The technique consists in the application of GFRP strips on masonry wall faces, bonded to the substrate and further connected to it through mechanical anchorages. The effectiveness of this technique is highly dependent on the capability of developing high stresses on the composite reinforcement, which, in turn, depends on bonding and anchorage effectiveness. For this reason, an extensive experimental program devoted to the study of interface bonding was conducted. An innovative test setup was developed, consisting of modifications carried out on the “beam test” configuration, with the use of a dummy steel block, thus leading to a reduction of the number of manufactured masonry blocks. A total number of 29 specimens were tested, varying, amongst other things, the number and spacing of anchorages. As a general conclusion of the experimental program, it can be stated that the existence of anchorages proves to be highly beneficial in increasing the strength and deformation capacity of strengthened masonry walls. Tests have shown that the strengthening technique is extremely effective, leading to high tensile stresses in the GFRP strips, which, in turn, led to premature failure modes in some of the tests. Specimens with multiple anchorages have shown higher deformation capacity than those with single anchorage. Maximum composite force showed no significant dependency on the anchorage spacing and a consistent decrease in strength in specimens subjected to cyclic load history was not identified. Increasing anchorage spacing may lead to debonding failure, whereas decreasing spacing leads to an increase in cost and workmanship. An intermediate spacing—in the order of magnitude of the wall thickness—is recommended.

42 ENGINEERING↗

The use of a silicon strip detector dose magnifying glass in stereotactic radiotherapy QA and dosimetry

Purpose: Stereotactic radiosurgery/therapy (SRS/SRT) is the use of radiation ablation in place of conventional surgical excision to remove or create fibrous tissue in small target volumes. The target of the SRT/SRS treatment is often located in close proximity to critical organs, hence the requirement of high geometric precision including a tight margin on the planning target volume and a sharp dose fall off. One of the major problems with quality assurance (QA) of SRT/SRS is the availability of suitable detectors with the required spatial resolution. The authors present a novel detector that they refer to as the dose magnifying glass (DMG), which has a high spatial resolution (0.2 mm) and is capable of meeting the stringent requirements of QA and dosimetry in SRS/SRT therapy. Methods: The DMG is an array of 128 phosphor implanted n{sup +} strips on a p-type Si wafer. The sensitive area defined by a single n{sup +} strip is 20x2000 {mu}m{sup 2}. The Si wafer is 375 {mu}m thick. It is mounted on a 0.12 mm thick Kapton substrate. The authors studied the dose per pulse (dpp) and angular response of the detector in a custom-made SRS phantom. The DMG was used to determine the centers of rotation and positioning errors for the linear accelerator's gantry, couch, and collimator rotations. They also used the DMG to measure the profiles and the total scatter factor (S{sub cp}) of the SRS cones. Comparisons were made with the EBT2 film and standard S{sub cp} values. The DMG was also used for dosimetric verification of a typical SRS treatment with various noncoplanar fields and arc treatments when applied to the phantom. Results: The dose per pulse dependency of the DMG was found to be <5% for a dpp change of 7.5 times. The angular response of the detector was investigated in the azimuthal and polar directions. The maximum polar angular response was 13.8% at the gantry angle of 320 deg., which may be partly due to the phantom geometry. The maximum azimuthal angular response was 15.3% at gantry angles of 90 deg. and 270 deg. The angular response at the gantry angle of 180 deg. was 6.3%. A correction function was derived to correct for the angular dependence of the detector, which takes into account the contribution of the azimuthal and polar angular response at different treatment couch positions. The maximum positioning errors due to collimator, gantry, and couch rotation were 0.2{+-}0.1, 0.4{+-}0.1, and 0.4{+-}0.2 mm, respectively. The SRS cone S{sub cp} agrees very well with the standard data with an average difference of 1.2{+-}1.1%. Comparison of the relative intensity profiles of the DMG and EBT2 measurements for a simulated SRS treatment shows a maximum difference of 2.5%. Conclusions: The DMG was investigated for dose per pulse and angular dependency. Its application to SRS/SRT delivery verification was demonstrated. The DMG with its high spatial resolution and real time capability allows measurement of dose profiles for cone applicators down to 5 mm in diameter, both accurately and rapidly as required in typical SRS/SRT deliveries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-18C-05: Characterization of a Silicon Strip Photon-Counting Detector in the Presence of Compton Scatter: A Simulation Study

Purpose: To investigate the effect of Compton scatter on detection efficiency and charge-sharing for a Si strip photon-counting detector as a function of pixel pitch, slice thickness and total pixel length. Methods: A CT imaging system employing a silicon photon-counting detector was implemented using the GATE Monte Carlo package. A focal spot size of 300 µm, magnification of 1.33, and pixel pitches of 0.1 and 0.5mm were initially investigated. A 60 kVp spectrum with 3 mm Al filter was used and energy spectral degradation based on a prototype detector was simulated. To study charge-sharing, a single pixel was illuminated, and the detector response in neighboring pixels was investigated. A longitudinally semiinfinite detector was simulated to optimize the quantum detection efficiency of the imaging system as a function of pixel pitch, slice thickness and depth of interaction. A 2.5 mm thick tungsten plate with a 0.01 mm by 1.5 mm slit was implemented to calculate the modulation transfer function (MTF) from projection-based images. A threshold of 15 keV was implemented in the detector simulation. The preliminary charge sharing investigation results considered only scattering effects and the detector electronics related factors were neglected. Results: Using a 15 keV threshold, 1% of the pixel charge migrated into neighboring pixels with a pixel size of 0.1×0.1 mm{sup 2}. The quantum detection efficiency was 77%, 84%, 87% and 89% for 15 mm, 22.5 mm, 30 mm, and 45 mm length silicon detector pixels, respectively. For a pixel pitch of 0.1 mm, the spatial frequency at 10% of the maximum MTF was found to be 5.2 lp/mm. This agreed with an experimental MTF measurement of 5.3 lp/mm with a similar detector configuration. Conclusion: Using optimized design parameters, Si strip photon-counting detectors can offer high detection efficiency and spatial resolution even in the presence of Compton scatter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characteristic performance evaluation of a photon counting Si strip detector for low dose spectral breast CT imaging

Purpose: The possible clinical applications which can be performed using a newly developed detector depend on the detector's characteristic performance in a number of metrics including the dynamic range, resolution, uniformity, and stability. The authors have evaluated a prototype energy resolved fast photon counting x-ray detector based on a silicon (Si) strip sensor used in an edge-on geometry with an application specific integrated circuit to record the number of x-rays and their energies at high flux and fast frame rates. The investigated detector was integrated with a dedicated breast spectral computed tomography (CT) system to make use of the detector's high spatial and energy resolution and low noise performance under conditions suitable for clinical breast imaging. The aim of this article is to investigate the intrinsic characteristics of the detector, in terms of maximum output count rate, spatial and energy resolution, and noise performance of the imaging system. Methods: The maximum output count rate was obtained with a 50 W x-ray tube with a maximum continuous output of 50 kVp at 1.0 mA. A{sup 109}Cd source, with a characteristic x-ray peak at 22 keV from Ag, was used to measure the energy resolution of the detector. The axial plane modulation transfer function (MTF) was measured using a 67 μm diameter tungsten wire. The two-dimensional (2D) noise power spectrum (NPS) was measured using flat field images and noise equivalent quanta (NEQ) were calculated using the MTF and NPS results. The image quality parameters were studied as a function of various radiation doses and reconstruction filters. The one-dimensional (1D) NPS was used to investigate the effect of electronic noise elimination by varying the minimum energy threshold. Results: A maximum output count rate of 100 million counts per second per square millimeter (cps/mm{sup 2}) has been obtained (1 million cps per 100 × 100 μm pixel). The electrical noise floor was less than 4 keV. The energy resolution measured with the 22 keV photons from a {sup 109}Cd source was less than 9%. A reduction of image noise was shown in all the spatial frequencies in 1D NPS as a result of the elimination of the electronic noise. The spatial resolution was measured just above 5 line pairs per mm (lp/mm) where 10% of MTF corresponded to 5.4 mm{sup −1}. The 2D NPS and NEQ shows a low noise floor and a linear dependence on dose. The reconstruction filter choice affected both of the MTF and NPS results, but had a weak effect on the NEQ. Conclusions: The prototype energy resolved photon counting Si strip detector can offer superior imaging performance for dedicated breast CT as compared to a conventional energy-integrating detector due to its high output count rate, high spatial and energy resolution, and low noise characteristics, which are essential characteristics for spectral breast CT imaging.

60 APPLIED LIFE SCIENCES↗

Calibration of cathode strip gains in multiwire drift chambers of the GlueX experiment

A technique for calibrating cathode strip gains in multiwire drift chambers of the GlueX experiment is described. The accuracy of the technique is estimated based on Monte Carlo generated data with known gain coefficients in the strip signal channels. One of the four detector sections has been calibrated using cosmic rays. Results of drift chamber calibration on the accelerator beam upon inclusion in the GlueX experimental setup are presented.

Berdnikov, V. V.↗

Study of silicon strip waveguides with diffraction gratings and photonic crystals tuned to a wavelength of 1.5 µm

Single-mode submicrometer-thick strip waveguides on silicon-on-insulator substrates, fabricated by silicon-planar-technology methods are considered. To solve the problem of 1.5-µm wavelength radiation input-output and its frequency filtering, strip diffraction gratings and two-dimensional photonic crystals are integrated into waveguides. The reflection and transmission spectra of gratings and photonic crystals are calculated. The waveguide-mode-attenuation coefficient for a polycrystalline silicon waveguide is experimentally estimated.

36 MATERIALS SCIENCE↗

The extent of the stop coannihilation strip

Many supersymmetric models such as the constrained minimal supersymmetric extension of the Standard Model (CMSSM) feature a strip in parameter space where the lightest neutralino χ is identified as the lightest supersymmetric particle, the lighter stop squark $\tilde{t}_1$ is the next-tolightest supersymmetric particle (NLSP), and the relic χ cold dark matter density is brought into the range allowed by astrophysics and cosmology by coannihilation with the lighter stop squark $\tilde{t}_1$ NLSP. We calculate the stop coannihilation strip in the CMSSM, incorporating Sommerfeld enhancement effects, and we explore the relevant phenomenological constraints and phenomenological signatures. In particular, we show that the $\tilde{t}_1$ may weigh several TeV, and its lifetime may be in the nanosecond range, features that are more general than the specific CMSSM scenarios that we study in this paper.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Helium: lifting high-performance stencil kernels from stripped x86 binaries to halide DSL code

Highly optimized programs are prone to bit rot, where performance quickly becomes suboptimal in the face of new hardware and compiler techniques. In this paper we show how to automatically lift performance-critical stencil kernels from a stripped x86 binary and generate the corresponding code in the high-level domain-specific language Halide. Using Halide's state-of-the-art optimizations targeting current hardware, we show that new optimized versions of these kernels can replace the originals to rejuvenate the application for newer hardware. The original optimized code for kernels in stripped binaries is nearly impossible to analyze statically. Instead, we rely on dynamic traces to regenerate the kernels. We perform buffer structure reconstruction to identify input, intermediate and output buffer shapes. Here, we abstract from a forest of concrete dependency trees which contain absolute memory addresses to symbolic trees suitable for high-level code generation. This is done by canonicalizing trees, clustering them based on structure, inferring higher-dimensional buffer accesses and finally by solving a set of linear equations based on buffer accesses to lift them up to simple, high-level expressions. Helium can handle highly optimized, complex stencil kernels with input-dependent conditionals. We lift seven kernels from Adobe Photoshop giving a 75 % performance improvement, four kernels from Irfan View, leading to 4.97 x performance, and one stencil from the mini GMG multigrid benchmark netting a 4.25 x improvement in performance. We manually rejuvenated Photoshop by replacing eleven of Photoshop's filters with our lifted implementations, giving 1.12 x speedup without affecting the user experience.

97 MATHEMATICS AND COMPUTING↗

Flow Injection Electrochemical Quartz Crystal Microbalance with ICP-OES Detection: Electroprecipitation and Stripping of Lanthanum and Neodymium in a Flow Cell

We used an improved version of our hyphenated analysis technique, flow injection electrochemical quartz crystal microbalance (EQCM) with inductively coupled optical emission spectroscopy, to investigate the electroprecipitation of lanthanum and neodymium from flowing solutions. The improved version has two independent flow injection circuits, allowing different conditions for electrochemical precipitation (pH=4.3 or 2.6) and quick stripping (2% HNO3) with EQCM mass detection and ICP-OES elemental analysis. Lanthanum or neodymium ions in a 500 uL sample were injected into a carrier stream and deposited onto an EQCM housed in a micro flow cell, owing to a localized high-pH layer. The deposits are subsequently stripped from the electrode using HNO3 and analyzed downstream using an ICP-OES. We found that using acidic solutions without supporting electrolyte leads to an increase of the amount of lanthanum detected by 4-fold. The enhanced deposition can be attributed to enhanced mass transfer by migration. Furthermore, we showed that by applying chronopotentiometry, we can detect a change in the hydrogen evolution reaction mechanism that enables the precipitation of lanthanides on the surface of the electrode. Understanding and enhancing the deposition of lanthanides is relevant for elemental or isotopic detection in nuclear forensics.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Investigation of Lithium Plating-Stripping Process in Li-Ion Batteries at Low Temperature Using an Electrochemical Model

Lithium plating leads to severe capacity fading and possible safety problems in lithium-ion batteries. Thus, non-destructive detection methods for lithium plating are critical for safe and reliable operation of lithium-ion batteries. In this paper, an electrochemical model incorporated with lithium plating and stripping reactions is established to investigate the lithium plating-stripping process at low temperature. The model is validated at different current rates and temperatures and can successfully predict the characteristic voltage plateau during the rest period after low temperature charging. Modeling analysis helps to develop detection method for lithium plating via differential analysis on the voltage plateau. Distinct local minima can be found in the differential voltage curves of the batteries with plated lithium. The time when the local minima occurs in the differential voltage curves exhibits a linear relationship with the amount of reversible lithium, and thus can be applied as a quantitative indicator for detection of lithium plating. The detection of lithium plating based on differential voltage analysis is further extended to the discharge voltage profiles of the batteries after low temperature charging, considering the effects of rest time.

25 ENERGY STORAGE↗

Mid-infrared frequency doubling using strip-loaded silicon nitride on epitaxial barium titanate thin film waveguides

Broadband mid-infrared (mid-IR) frequency doubling was demonstrated using nonlinear barium titanate (BTO) thin films. The device has a strip-loaded waveguide structure consisting of top silicon nitride (SiN) strips and an underneath BTO guiding layer. The epitaxial BTO was deposited on a strontium titanate (STO) substrate by pulsed-laser deposition. Through a SiN grating coupler, the pumping mid-IR light at wavelength &#x03BB;<!-- λ --> = 3.30 &#x2212;<!-- - --> 3.45 &#x00B5;<!-- µ --> m was coupled into the nonlinear BTO layer, where the spectrum of the near-infrared (NIR) second-harmonic generation was characterized. The developed BTO waveguides provide a platform for mid-IR nonlinear integrated photonics and on-chip quantum optics.

42 ENGINEERING↗