Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Soft computing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Thermal disorder and phonon softening in the ferroelectric phase transition of lead titanate

We report a molecular dynamics study of ab initio quality of the ferroelectric phase transition in crystalline PbTi⁢O3. We model anharmonicity accurately in terms of potential energy and polarization surfaces trained on density functional theory data with modern machine learning techniques. Our simulations demonstrate that the transition has a strong order-disorder character, in agreement with diffraction experiments, and provide fresh insight into the approach to equilibrium across the phase transition. We find that the emergence and disappearance of the macroscopic polarization is driven by dipolar switching at the nanometer scale. We also computed the infrared optical absorption spectra in both the ferroelectric and the paraelectric phases, finding good agreement with the experimental Raman frequencies. Often, the almost ideal displacive character of the soft mode detected by Raman scattering in the paraelectric phase has been contrasted with the order-disorder character of the transition suggested by diffraction experiments. We settle this issue by showing that the soft mode coexists with a strong Debye relaxation associated with thermal disordering of the dipoles. The Debye relaxation feature is centered at zero frequency and appears near the transition temperature in both the ferroelectric and the paraelectric phases.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Data-Driven Approach to Nation-Scale Building Energy Modeling

In 2019, 125 million U.S. residential and commercial buildings consumed $412 billion in energy bills. These buildings currently consume 40% of the nation's primary energy, 73% of electricity, 80% of energy during peak electric grid use, and responsible for 39% of greenhouse gas emissions [14]. Urban-scale building energy modeling has grown significantly in the past decade, allowing individual campuses or communities of buildings to be modeled, simulated, and cost-effective solutions for intelligent management to be identified and implemented. While traditionally limited to individual counties and usually less than 2,000 buildings, the Automatic Building Energy Modeling (AutoBEM) soft-ware suite has been developed to process unconventional, nation-scale data sources to generate unique OpenStudio and EnergyPlus models of each building. Through the use of High Performance Computing (HPC) resources, every U.S. building has been simulated. This paper showcases the data layout, node partitioning, algorithmic approaches, and analytic results that were used to create, share, and analyze 124.4 million U.S. building models.

Berres, Andy↗

Liquid Crystal Orientation and Shape Optimization for the Active Response of Liquid Crystal Elastomers

Liquid crystal elastomers (LCEs) are responsive materials that can undergo large reversible deformations upon exposure to external stimuli, such as electrical and thermal fields. Controlling the alignment of their liquid crystals mesogens to achieve desired shape changes unlocks a new design paradigm that is unavailable when using traditional materials. While experimental measurements can provide valuable insights into their behavior, computational analysis is essential to exploit their full potential. Accurate simulation is not, however, the end goal; rather, it is the means to achieve their optimal design. Such design optimization problems are best solved with algorithms that require gradients, i.e., sensitivities, of the cost and constraint functions with respect to the design parameters, to efficiently traverse the design space. In this work, a nonlinear LCE model and adjoint sensitivity analysis are implemented in a scalable and flexible finite element-based open source framework and integrated into a gradient-based design optimization tool. To display the versatility of the computational framework, LCE design problems that optimize both the material, i.e., liquid crystal orientation, and structural shape to reach a target actuated shapes or maximize energy absorption are solved. Multiple parameterizations, customized to address fabrication limitations, are investigated in both 2D and 3D. The case studies are followed by a discussion on the simulation and design optimization hurdles, as well as potential avenues for improving the robustness of similar computational frameworks for applications of interest.

42 ENGINEERING↗

Intrafraction Bladder Motion in Radiation Therapy Estimated From Pretreatment and Posttreatment Volumetric Imaging

Purpose: The use of image guidance protocols using soft tissue anatomy identification before treatment can reduce interfractional variation. This makes intrafraction clinical target volume (CTV) to planning target volume (PTV) changes more important, including those resulting from intrafraction bladder filling and motion. The purpose of this study was to investigate the required intrafraction margins for soft tissue image guidance from pretreatment and posttreatment volumetric imaging. Methods and Materials: Fifty patients with muscle-invasive bladder cancer (T2-T4) underwent an adaptive radiation therapy protocol using daily pretreatment cone beam computed tomography (CBCT) with weekly posttreatment CBCT. A total of 235 pairs of pretreatment and posttreatment CBCT images were retrospectively contoured by a single radiation oncologist (CBCT-CTV). The maximum bladder displacement was measured according to the patient's bony pelvis movement during treatment, intrafraction bladder filling, and bladder centroid motion. Results: The mean time between pretreatment and posttreatment CBCT was 13 minutes, 52 seconds (range, 7 min 52 sec to 30 min 56 sec). Taking into account patient motion, bladder centroid motion, and bladder filling, the required margins to cover intrafraction changes from pretreatment to posttreatment in the superior, inferior, right, left, anterior, and posterior were 1.25 cm (range, 1.19-1.50 cm), 0.67 cm (range, 0.58-1.12 cm), 0.74 cm (range, 0.59-0.94 cm), 0.73 cm (range, 0.51-1.00 cm), 1.20 cm (range, 0.85-1.32 cm), and 0.86 cm (range, 0.73-0.99), respectively. Small bladders on pretreatment imaging had relatively the largest increase in pretreatment to posttreatment volume. Conclusion: Intrafraction motion of the bladder based on pretreatment and posttreatment bladder imaging can be significant particularly in the anterior and superior directions. Patient motion, bladder centroid motion, and bladder filling all contribute to changes between pretreatment and posttreatment imaging. Asymmetric expansion of CTV to PTV should be considered. Care is required in using image-guided radiation therapy protocols that reduce CTV to PTV margins based only on daily pretreatment soft tissue position.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase II Study of Neoadjuvant Bevacizumab and Radiotherapy for Resectable Soft Tissue Sarcomas

Purpose: Numerous preclinical studies have demonstrated that angiogenesis inhibitors can increase the efficacy of radiotherapy (RT). We sought to examine the safety and efficacy of bevacizumab (BV) and RT in soft tissue sarcomas and explore biomarkers to help determine the treatment response. Methods and Materials: Patients with {>=}5 cm, intermediate- or high-grade soft tissue sarcomas at significant risk of local recurrence received neoadjuvant BV alone followed by BV plus RT before surgical resection. Correlative science studies included analysis of the serial blood and tumor samples and serial perfusion computed tomography scans. Results: The 20 patients had a median tumor size of 8.25 cm, with 13 extremity, 1 trunk, and 6 retroperitoneal/pelvis tumors. The neoadjuvant treatment was well tolerated, with only 4 patients having Grade 3 toxicities (hypertension, liver function test elevation). BV plus RT resulted in {>=}80% pathologic necrosis in 9 (45%) of 20 tumors, more than double the historical rate seen with RT alone. Three patients had a complete pathologic response. The median microvessel density decreased 53% after BV alone (p <.05). After combination therapy, the median tumor cell proliferation decreased by 73%, apoptosis increased 10.4-fold, and the blood flow, blood volume, and permeability surface area decreased by 62-72% (p <.05). Analysis of gene expression microarrays of untreated tumors identified a 24-gene signature for treatment response. The microvessel density and circulating progenitor cells at baseline and the reduction in microvessel density and plasma soluble c-KIT with BV therapy also correlated with a good pathologic response (p <.05). After a median follow-up of 20 months, only 1 patient had developed local recurrence. Conclusions: The results from the present exploratory study indicated that BV increases the efficacy of RT against soft tissue sarcomas and might reduce the incidence of local recurrence. Thus, this regimen warrants additional investigation. Gene expression profiles and other tissue and circulating biomarkers showed promising correlations with treatment response.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative resonant soft x-ray reflectivity of ultrathin anisotropic organic layers: Simulation and experiment of PTCDA on Au

Resonant soft X-ray reflectivity at the carbon K edge, with linearly polarized light, was used to derive quantitative information of film morphology, molecular arrangement, and electronic orbital anisotropies of an ultrathin 3,4,9,10-perylene tetracarboxylic dianhydride (PTCDA) film on Au(111). The experimental spectra were simulated by computing the propagation of the electromagnetic field in a trilayer system (vacuum/PTCDA/Au), where the organic film was treated as an anisotropic medium. Optical constants were derived from the calculated (through density functional theory) absorption cross sections of the single molecule along the three principal molecular axes. These were used to construct the dielectric tensor of the film, assuming the molecules to be lying flat with respect to the substrate and with a herringbone arrangement parallel to the substrate plane. Resonant soft X-ray reflectivity proved to be extremely sensitive to film thickness, down to the single molecular layer. The best agreement between simulation and experiment was found for a film of 1.6 nm, with flat laying configuration of the molecules. The high sensitivity to experimental geometries in terms of beam incidence and light polarization was also clarified through simulations. The optical anisotropies of the organic film were experimentally determined and through the comparison with calculations, it was possible to relate them to the orbital symmetry of the empty electronic states.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TH-A-18C-01: Design Optimization of Segmented Scintillators for Megavoltage Cone- Beam CT

Purpose: Active matrix flat-panel imagers incorporating thick, segmented scintillators for megavoltage cone-beam CT (MV CBCT) imaging have demonstrated strong potential for facilitating soft-tissue visualization at low, clinically practical doses. In order to identify scintillator design parameters that optimize performance for this purpose, a modeling technique which includes both radiation and optical effects and which lends itself to computationally practical implementation has been developed and explored. Methods: A hybrid modeling technique, based on Monte Carlo event-by-event simulation of radiation transport and separate determination of optical effects, was devised as an alternative to computationally prohibitive event-by- event simulations of both radiation and optical transport. The technique was validated against empirical results from a previously reported 1.13 cm thick, 1.016 mm element-to-element pitch BGO scintillator prototype. Using this technique, the contrast-to-noise ratio (CNR) and spatial resolution performance of numerous scintillator designs, with thicknesses ranging from 0.5 to 6 cm and pitches ranging from 0.508 to 1.524 mm, were examined. Results: CNR and spatial resolution performance for the various scintillator designs demonstrate complex behavior as scintillator thickness and pitch are varied - exhibiting a clear trade-off between these two imaging metrics up to a thickness of ~3 cm. Based on these results, an optimization map highlighting those regions of design that provide a balance between these metrics was created. The map indicates that, for a given set of optical parameters, scintillator thickness and pitch can be judiciously chosen to maximize performance without resorting to thicker, more costly scintillators. Conclusion: Modeling radiation and optical effects in thick, segmented scintillators through use of a hybrid modeling technique provides a practical way to gain insight as to how to optimize the performance of such devices for radiotherapy imaging. Assisted by such modeling, the development of practical designs should greatly facilitate low-dose, soft tissue visualization through MV CBCT imaging. This project was supported in part by NIH grant R01 CA051397.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cooperativity and Metal–Linker Dynamics in Spin Crossover Framework Fe(1,2,3-triazolate) 2

Cooperative interactions are responsible for the useful properties of spin crossover (SCO) materials–large hysteresis windows, critical temperatures near room temperature, and abrupt transitions–with hybrid framework materials exhibiting the greatest cooperativity and hysteresis of all SCO systems. However, little is known about the chemical origin of cooperativity in frameworks. Here, we present a combined experimental–computational approach for identifying the origin of cooperativity in the metal–organic framework (MOF) Fe(1,2,3-triazolate) 2 (Fe(TA) 2 ), which exhibits the largest known hysteresis window of all SCO materials and unusually high transition temperatures, as a roadmap for understanding the manipulation of SCO behavior in general. Variable-temperature vibrational spectroscopy provides evidence that “soft modes” associated with dynamic metal–linker bonding trigger the cooperative SCO transition. Thermodynamic analysis also confirms a cooperativity magnitude much larger than those of other SCO systems, while electron density calculations of Fe(TA) 2 support previous theoretical predictions that large cooperativity arises in materials where SCO produces considerable differences in metal–ligand bond polarities between different spin states. Taken together, this combined experimental–computational study provides a microscopic basis for understanding cooperative magnetism and highlights the important role of dynamic bonding in the functional behavior of framework materials.

36 MATERIALS SCIENCE↗

Computational study of frontier orbitals, moments, chemical reactivity and thermodynamic parameters of sildenafil

Analysis of frontier orbitals of sildenafil has been carried using Density Functional Theory. On the basis of HOMO-LUMO energy, values of global chemical reactivity descriptors such as electronegativity, chemical hardness, softness, chemical potential, electrophilicity index have been calculated. Calculated values of dipole moment, polarizability, hyperpolarizability have also been reported for sildenafil along with its thermodynamic parameters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Distilling particle knowledge for fast reconstruction at high-energy physics experiments

Knowledge distillation is a form of model compression that allows artificial neural networks of different sizes to learn from one another. Its main application is the compactification of large deep neural networks to free up computational resources, in particular on edge devices. In this article, we consider proton-proton collisions at the High-Luminosity Large Hadron Collider (HL-LHC) and demonstrate a successful knowledge transfer from an event-level graph neural network (GNN) to a particle-level small deep neural network (DNN). Our algorithm, DistillNet, is a DNN that is trained to learn about the provenance of particles, as provided by the soft labels that are the GNN outputs, to predict whether or not a particle originates from the primary interaction vertex. The results indicate that for this problem, which is one of the main challenges at the HL-LHC, there is minimal loss during the transfer of knowledge to the small student network, while improving significantly the computational resource needs compared to the teacher. This is demonstrated for the distilled student network on a CPU, as well as for a quantized and pruned student network deployed on a field programmable gate array. Our study proves that knowledge transfer between networks of different complexity can be used for fast artificial intelligence (AI) in high-energy physics that improves the expressiveness of observables over non-AI-based reconstruction algorithms. Such an approach can become essential at the HL-LHC experiments, e.g. to comply with the resource budget of their trigger stages.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Block copolymer self-assembly derived mesoporous magnetic materials with three-dimensionally (3D) co-continuous gyroid nanostructure

Magnetic nanomaterials are gaining interest for their many applications in technological areas from information science and computing to next-generation quantum energy materials. While magnetic materials have historically been nanostructured through techniques such as lithography and molecular beam epitaxy, there has recently been growing interest in using soft matter self-assembly. In this work, a triblock terpolymer, poly(isoprene-block-styrene-block-ethylene oxide) (ISO), is used as a structure directing agent for aluminosilicate sol nanoparticles and magnetic material precursors to generate organic–inorganic bulk hybrid films with co-continuous morphology. After thermal processing into mesoporous materials, results from a combination of small angle X-ray scattering (SAXS) and scanning electron microscopy (SEM) are consistent with the double gyroid morphology. Nitrogen sorption measurements reveal a type IV isotherm with H1 hysteresis, and yield a specific surface area of around 200 m 2 g −1 and an average pore size of 23 nm. The magnetization of the mesostructured material as a function of applied field shows magnetic hysteresis and coercivity at 300 K and 10 K. Comparison of magnetic measurements between the mesoporous gyroid and an unstructured bulk magnetic material, derived from the identical inorganic precursors, reveals the structured material exhibits a coercivity of 250 Oe, opposed to 148 Oe for the unstructured at 10 K, and presence of remnant magnetic moment not conventionally found in bulk hematite; both of these properties are attributed to the mesostructure. This scalable route to mesoporous magnetic materials with co-continuous morphologies from block copolymer self-assembly may provide a pathway to advanced magnetic nanomaterials with a range of potential applications.

Chemistry↗

van der Waals-corrected density functional study of electric field noise heating in ion traps caused by electrode surface adsorbates

Abstract In order to realize the full potential of ion trap quantum computers, an improved understanding is required of the motional heating that trapped ions experience. Experimental studies of the temperature-, frequency-, and ion–electrode distance-dependence of the electric field noise responsible for motional heating, as well as the noise before and after ion bombardment cleaning of trap electrodes, suggest that fluctuations of adsorbate dipoles are a likely source of so-called ‘anomalous heating,’ or motional heating of the trapped ions at a rate much higher than the Johnson noise limit. Previous computational studies have investigated how the fluctuation of model adsorbate dipoles affects anomalous heating. However, the way in which specific adsorbates affect the electric field noise has not yet been examined, and an electric dipole model employed in previous studies is only accurate for a small subset of possible adsorbates. Here, we analyze the behavior of both in-plane and out-of-plane vibrational modes of twenty-one adsorbate–electrode combinations within the independent fluctuating dipole model, utilizing accurate first principles computational methods to determine the surface-induced dipole moments. We find the chemical specificity of the adsorbate can change the electric field noise by seven orders of magnitude and specifically that soft in-plane modes of weakly-adsorbed hydrocarbons produce the greatest noise and ion heating. We discuss the dynamics captured by the fluctuating dipole model, namely the adsorbate-dependent turn-on temperature and electric field noise magnitude, and also discuss the model’s failure to reproduce the measured 1/ ω noise frequency scaling with a single adsorbate species. We suggest future research directions for improved, quantitatively predictive models based on extensions of the present framework to multiple interacting adsorbates.

74 ATOMIC AND MOLECULAR PHYSICS↗

Quantum electrodynamics mediated by a photon with continuous spin

In recent work with Zhou, we studied classical interactions of matter with a “continuous spin” field, whose excitations have zero mass but nonzero spin Casimir (spin scale) ρ . We reported evidence that such theories are a calculable infrared deformation of familiar massless theories including electromagnetism. Building on the aforementioned work, this paper presents rules for computing scattering amplitudes involving charged scalar matter and continuous spin photons with nonzero spin scale. As a concrete example, we compute the pair annihilation and Compton scattering amplitudes in this theory and comment on their physical properties, including unitarity and scaling behavior at small and large ρ . Like the classical physics and soft factors studied in prior work, these amplitudes exhibit “helicity correspondence,” recovering familiar amplitudes at energy scales ≫ ρ , but with calculable deviations that could be experimentally tested. These results bolster the conjecture that continuous spin particles with a very small ρ could mediate long-range forces in nature (e.g., the photon could be a continuous spin particle), and extend the range of physical effects that could be used to test this hypothesis. Published by the American Physical Society 2024

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A convex pseudolikelihood framework for high dimensional partial correlation estimation with convergence guarantees

Sparse high dimensional graphical model selection is a topic of much interest in modern day statistics. A popular approach is to apply l1-penalties to either parametric likelihoods, or regularized regression/pseudolikelihoods, with the latter having the distinct advantage that they do not explicitly assume Gaussianity. As none of the popular methods proposed for solving pseudolikelihood-based objective functions have provable convergence guarantees, it is not clear whether corresponding estimators exist or are even computable, or if they actually yield correct partial correlation graphs. We propose a new pseudolikelihood-based graphical model selection method that aims to overcome some of the shortcomings of current methods, but at the same time retain all their respective strengths. In particular, we introduce a novel framework that leads to a convex formulation of the partial covariance regression graph problem, resulting in an objective function comprised of quadratic forms. The objective is then optimized via a coordinate wise approach. The specific functional form of the objective function facilitates rigorous convergence analysis leading to convergence guarantees; an important property that cannot be established by using standard results, when the dimension is larger than the sample size, as is often the case in high dimensional applications. These convergence guarantees ensure that estimators are well defined under very general conditions and are always computable. In addition, the approach yields estimators that have good large sample properties and also respect symmetry. Furthermore, application to simulated and real data, timing comparisons and numerical convergence is demonstrated. We also present a novel unifying framework that places all graphical pseudolikelihood methods as special cases of a more general formulation, leading to important insights.

97 MATHEMATICS AND COMPUTING↗

Dosimetric variation due to the photon beam energy in the small-animal irradiation: A Monte Carlo study

Purpose: The impact of photon beam energy and tissue heterogeneities on dose distributions and dosimetric characteristics such as point dose, mean dose, and maximum dose was investigated in the context of small-animal irradiation using Monte Carlo simulations based on the EGSnrc code. Methods: Three Monte Carlo mouse phantoms, namely, heterogeneous, homogeneous, and bone homogeneous were generated based on the same mouse computed tomography image set. These phantoms were generated by overriding the tissue type of none of the voxels (heterogeneous), all voxels (homogeneous), and only the bone voxels (bone homogeneous) to that of soft tissue. Phase space files of the 100 and 225 kVp photon beams based on a small-animal irradiator (XRad225Cx, Precision X-Ray Inc., North Branford, CT) were generated using BEAMnrc. A 360 deg. photon arc was simulated and three-dimensional (3D) dose calculations were carried out using the DOSXYZnrc code through DOSCTP in the above three phantoms. For comparison, the 3D dose distributions, dose profiles, mean, maximum, and point doses at different locations such as the isocenter, lung, rib, and spine were determined in the three phantoms. Results: The dose gradient resulting from the 225 kVp arc was found to be steeper than for the 100 kVp arc. The mean dose was found to be 1.29 and 1.14 times higher for the heterogeneous phantom when compared to the mean dose in the homogeneous phantom using the 100 and 225 kVp photon arcs, respectively. The bone doses (rib and spine) in the heterogeneous mouse phantom were about five (100 kVp) and three (225 kVp) times higher when compared to the homogeneous phantom. However, the lung dose did not vary significantly between the heterogeneous, homogeneous, and bone homogeneous phantom for the 225 kVp compared to the 100 kVp photon beams. Conclusions: A significant bone dose enhancement was found when the 100 and 225 kVp photon beams were used in small-animal irradiation. This dosimetric effect, due to the presence of the bone heterogeneity, was more significant than that due to the lung heterogeneity. Hence, for kV photon energies of the range used in small-animal irradiation, the increase of the mean and bone dose due to the photoelectric effect could be a dosimetric concern.

60 APPLIED LIFE SCIENCES↗