Simple Battery Hazard Calculator

SAND2025-00455O Simple Battery Hazard Calculator is a software tool developed in Excel to analyze the electrical hazards of battery systems and determine the required personal protective equipment (PPE) for safe assembly and disassembly. It calculates potential arc flash incident energy, contact thermal hazard level, and recommends PPE based on parameters such as voltage, short circuit current, and over current protection trip time. The calculator uses a recognized method for calculating arc flash incident energy, which was previously inaccessible to most battery workers. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Rosewater, David↗

Experimental study of airpath electrification in an opposed-piston two stroke (OP2S) engine architecture

The opposed-piston two stroke (OP2S) engine shows potential as an alternative engine architecture to the conventional four stroke engine due to its high-power density, thermal efficiency, and versatile airpath management system. Since the pistons of a two-stroke engine do not pump the air into and out of the cylinder like in a four-stroke engine, the selection of the air induction devices and airpath actuators becomes critical to optimize engine performance. Both the pumping losses and the in-cylinder combustion process can be affected by the scavenging process in a two-stroke engine. Therefore, this study compares two different airpath configurations for the same family of OP2S engines and investigates performance metrics like scavenging control, pumping work, net indicated and brake efficiencies, and engine-out emissions associated with each airpath. Data was collected on a 3.2 L, two-cylinder OP2S engine with an electrically assisted turbocharger (EAT) and a 4.9 L displacement, three-cylinder engine with a variable geometry turbocharger (VGT) and a supercharger. The experiments consisted of speed and load sweeps for both engines at the same operating conditions to compare scavenge control in both architectures. For the three-cylinder layout, the SE sweep range was much higher, and the intake pressure could be independently varied with air flowrate, thus providing more flexibility for scavenging control. The supercharger and the VGT usage was optimized based on its efficiency map and thus, this layout had lower pumping losses compared to the EAT. The two-cylinder engine had a higher overall SE as compared to the three-cylinder engine, but the intake pressure and air flowrate could not be decoupled, leading to over scavenging and increased short circuiting of fresh charge into the exhaust.

Bhatt, Ankur [Clemson University, Clemson, SC, USA↗

Influence of extreme fracture flow channels on the thermal performance of open-loop geothermal systems at commercial scale

Abstract Adequate stewardship of geothermal resources requires accurate forecasting of long-term thermal performance. In enhanced geothermal systems and other fracture-dominated reservoirs, predictive models commonly assume constant-aperture fractures, although spatial variations in aperture can greatly affect reservoir permeability, fluid flow distribution, and heat transport. Whereas previous authors have investigated the effects of theoretical random aperture distributions on thermal performance, here we further explore the influence of permeability heterogeneity considering field-constrained aperture distributions from a meso-scale field site in northern New York, USA. Using numerical models of coupled fluid flow and heat transport, we conduct thermal–hydraulic simulations for a hypothetical reservoir consisting of a relatively impervious porous matrix and a single, horizontal fracture. Our results indicate that in highly channelized fields, most well design configurations and operating conditions result in extreme rates of thermal drawdown (e.g., 50% drop in production well temperatures in under 2 years). However, some other scenarios that account for the risks of short-circuiting can potentially enhance heat extraction when mass flow rate is not excessively high, and the direction of geothermal extraction is not aligned with the most permeable features in the reservoir. Through a parametric approach, we illustrate that well separation distance and relative positioning play a major role in the long-term performance of highly channelized fields, and both can be used to help mitigate premature thermal breakthrough.

Rangel-Jurado, Nicolás↗

Cybersecurity for Distance Relay Protection

This project is a DOE follow-up effort on the CREDC workshop held on September 13, 2018 in Cambridge, MA to discuss cybersecurity of distance relays, which considered the benefits, vulnerabilities and risk mitigations for the use of communication systems in power system protection. The objectives of this project are to define the taxonomy of relay protection and associated communications; define use cases describing approaches to reduce the cyber-attack surface on those protective relays; and evaluate the loss of operational functional capability from changes to communication coverage. Mitigating controls will also be evaluated to understand if there are other approaches to reduce attack surfaces while maintaining communications or partial communications. Distance relays are used to protect transmission lines of approximately 10 to 300 miles in length, by detecting short circuits (i.e., faults) on the lines and then tripping circuit breakers in the substation. Such protection systems are a subset of the power system and they incorporate sensing, logic and communication functions. Protection system exposure to cyberattack could be drastically limited by disconnecting relays from all vulnerable communication systems, but this may adversely impact overall power system performance in the absence of cyberattack. This project began with a use case analysis of protection systems with communications, as summarized in this report. It continued with modeling, testing and evaluation in a miniature power system (MPS), located in the Western Area Power Administration (WAPA) Electric Power Training Center (EPTC). The project also incorporated feedback from two industry meetings held in February and September 2019. The suggested next steps account for and complement the work already underway with DOE/CESER funding: 1. Study the performance of LCD and PC vs. PUTT, which is less reliant on communication system performance and GPS timing references. The PUTT scheme could prove to be more resilient to cyberattack or communications-related disruption. It could also be more tolerant of message re-routing with SDN/SDR communication systems. On the other hand, it will be more vulnerable to false tripping during dynamic events or to loss of the voltage signal. The optimum choice of scheme may depend on the specific power system and risk assessment. This study could provide a new template for evaluation based on business functions. 2. Research and develop new methods to detect and monitor distributed physical attacks, possibly using drones, video sensors, thermal sensors, machine learning and other advanced techniques. This will help mitigate the impact of cyberattack on the protection system, and will also help mitigate the impact of wild fires. 3. Implement a scalable PKI for use in electric utility protection systems. This will encourage widespread adoption of secure authentication methods that are already available, but not widely used at present. This will help secure engineering access to the relays. 4. Investigate the use of SDN in combination with SDR to achieve better cybersecurity and electromagnetic security of the network, incorporating path variability. This would help secure both engineering access and peer-to-peer GOOSE messaging. 5. Perform additional testing, with operator evaluation of “red button” scenarios, PUTT vs. LCD, relay mis-operations, and other cyberattacks in the EPTC. This is an important advantage of testing in the EPTC rather than by computer simulation or even hardware-in-the-loop simulation; the EPTC is already dedicated to managing the situational awareness, operator response times and other human impacts. One of the project objectives was to settle on a common nomenclature for this problem space. We have concluded that the OSI layer model, supplemented by ANSI device numbers and other IEEE standards, is already well-accepted by the industry. The IEEE PSRC knowledge base provides a great deal of public information

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development and Validation of a Simulation Tool to Predict the Combined Structural, Electrical, Electrochemical and Thermal Responses of Automotive Batteries

Battery safety is one of the most important design factors of electrified vehicles (EVs) since battery failure may lead to a catastrophic consequence. To improve the safety of battery systems in EVs, battery behaviors under various abuse conditions should be well understood. One way to examine battery response under extreme conditions is to conduct abuse tests in different scenarios. They can provide first-hand pass/fail information on battery safety, but they are usually expensive and time-consuming, which is inconvenient during design iterations and optimization. On the other hand, computational modeling can predict the battery behaviors in a more efficient and cost-effective way, which becomes an important tool to evaluate battery safety. Modeling battery responses and failure is challenging since it involves multiple coupled physical processes, needs to consider complex material properties and is computationally intensive. This project aims to develop a practical simulation tool to predict the combined structural, electrical, electrochemical, and thermal responses of automotive batteries to crash-induced crush and short circuit and validate it for conditions relevant to automotive crash. Advanced material constitutive models will be utilized to capture the mechanical response of cell components. Moreover, methods will be developed to reduce computational complexity of the model and allow battery safety simulations to extend from cell-level to module/pack level with affordable computational resources.

25 ENERGY STORAGE↗

Research and Development of a Ventilation-Integrated Comfort System

From an indoor air quality perspective, the best residential ventilation strategies include filtering outdoor air and distributing that air to all occupied parts of a home. From an energy standpoint, it is desirable that energy be transferred from the exhaust air to the incoming outdoor air to limit heating and cooling impacts. Heat or energy recovery ventilators (HRVs or ERVs) can provide these functions, but researchers have seen many poor installations related to design, installation, and operation and maintenance. More robust ventilation systems may involve an ERV with a dedicated duct distribution system and controls. Such a duct system can be costly to install, and many builders reduce these costs by connecting an ERV to a central heating and cooling duct system. Although this can sometimes be done effectively, researchers have seen consistent challenges with low, inconsistent, or imbalanced flow rates; high electricity consumption; and—of greatest concern—outdoor air short-circuiting or not being delivered to occupied spaces at all. Most ERVs are designed to operate with their own duct system; they are not designed as an add-on to much larger heating, ventilating, and air-conditioning (HVAC) systems. The ventilation-integrated comfort system (VICS) is expressly designed to integrate with low-capacity, efficient, ducted heating and cooling systems. Overall, the latest VICS prototype consumed 40–75 watts (W), including the air handler power, to deliver 50–120 cfm of whole-dwelling ventilation. The large, cross-flow ERV core performed to match manufacturer values (73% winter sensible effectiveness, 64% summer total effectiveness), but further improvements are possible. The VICS system researched and tested during this project will provide efficient, controllable, balanced energy recovery ventilation that is integrated with heating and cooling systems. The integration reduces space and ductwork needed for separate ventilation systems, and there are no compromises to heating, cooling, or ventilation performance. The integrated nature of the device also reduces risks for improper installation and commissioning. Even when using the air handler blower to distribute outdoor air, the total power consumption is lower than that of most available ERV products in the same airflow range. This system has the potential to offer very high-performance ventilation with much smoother and simpler installation than conventional systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Saturated Bioenergy Buffers: Site Suitability Classification and Estimated Areas of Candidate Sites in the U.S. Midwest Under Three Scenarios

The loss of nutrients applied to tile-drained row-crop fields is a critically important component of agriculture’s impact on surface water quality, because drain tiles provide a short circuit to ditches and creeks, resulting in rapid nutrient loss. This nutrient loss ultimately advances eutrophication and hypoxia, i.e., the creation of dead zones in bodies of water, both locally and regionally (for example, in western Lake Erie and the Gulf of Mexico). Saturated buffers help address the tile-drainage water quality problem, and incorporating bioenergy crops into saturated bioenergy buffers could provide both environmental protection and an additional source of income for farmers.

09 BIOMASS FUELS↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Research and Development of a Ventilation-Integrated Comfort System

From an indoor air quality perspective, the best residential ventilation strategies include filtering outdoor air and distributing that air to all occupied parts of a home. From an energy standpoint, it's desirable that energy be transferred from the exhaust air to the incoming outdoor air to limit heating and cooling impacts. Heat or energy recovery ventilation systems (HRVs or ERVs) can provide these functions, but researchers have seen many poor installations related to design, installation, and operation and maintenance. More robust ventilation systems may involve an ERV with a dedicated duct distribution system and controls. Such a duct system can be costly to install, and many builders reduce these costs by connecting an ERV to a central heating and cooling duct system. While this can sometimes be done effectively, researchers have seen consistent challenges with low, inconsistent, or imbalanced flow rates; high electricity consumption; and - of greatest concern - outdoor air short-circuiting or not being delivered to occupied spaces at all. Most ERVs are designed to operate with their own duct system; they are not designed as an add-on to much larger HVAC systems. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Mitsubishi Electric Trane US, CORE Energy Recovery Solutions, and Therma-Stor LLC to design and test VICS prototypes. A conceptual diagram is shown in Figure 1, and the latest prototype (shown in Figure 2) was manufactured by Therma-Stor and tested in SWA's facility in Norwalk, CT. The ERV heat exchanger was provided by CORE, and the VICS was installed in conjunction with a 1-ton, inverter heat pump provided by Mitsubishi.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Background Information on the Protection Requirements in IEEE Std 1547-2018

As the DER penetration level has risen significantly in recent times, parameter settings and configuration of installed DERs are having direct impact on local electric distribution utilities as well as bulk power systems during normal and abnormal grid conditions. On the other hand, all grid-connected DERs in the United States of America must conform to the interconnection requirements prescribed in the IEEE Std 1547-2018. Because of these reasons, it is crucial to understand the expected DER performance during abnormal grid conditions considering the requirements of the IEEE Std 1547-2018. The aim of this document is twofold: (1) to summarize requirements in IEEE Std 1547-2018 having direct implications in distribution network protection, and (2) to provide the reader with knowledge and information that will be required for users to apply the requirements specified. Since the focus of this document is on distribution network protection in the presence of DERs, it is assumed that the readers have basic understanding of distribution network protection as well as working principles of DERs. This document starts with a brief introduction on protection systems for distribution network followed by a discussion on the impact of DER on the protection systems. Current practices to provide network protection in the presence of DER is briefly discussed. The document then explores the DER performance requirements in IEEE Std. 1547-2018; especially on those related to distribution network protection. Section 6.1 in IEEE Std. 1547-2018 provides an overview of capabilities and control requirements for DER under abnormal operating conditions. This section also introduces abnormal operating performance categories I, II, III. The DER response to various types of faults and grid conditions such as short-circuit faults and open phase conditions are discussed in section 6.2 in the standard while requirements for coordination with the Area EPS reclosing scheme are provided in section 6.3. Section 6.4 in the IEEE Std 1547-2018 specifies requirements for mandatory voltage tripping and ride-through requirements during low and high voltage disturbances and section 6.5 specifies similar requirements for low and high frequency disturbances. IEEE Std. 1547 requires that the conformance of the DERs to IEEE Std 1547-2018 requirements should be verified in accordance with IEEE Std. 1547. 1. There are several parameters and settings of DERs that need to be properly selected for reliable operation during abnormal grid condition while applying the requirements of IEEE Std 1547-2018. Key decisions for proper selections of parameter and settings are: 1. Determination of required DER abnormal operating performance category, 2. Determination of DER response (shall trip) to abnormal voltages and 3. Determination of DER response (shall trip) to abnormal frequency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrochemically Stable High Energy Density Lithium-Sulfur Batteries

Lithium-Sulfur batteries (LSB) have emerged as one of the strong contenders for high energy density rechargeable batteries in the Li-ion battery domain. The LSB system is considered as the most promising to achieve the next milestone in energy density of 500 Wh/kg. However, the LSB system is plagued with problems of polysulfide formation which are soluble in the organic electrolyte leading to loss in capacity and eventual cell failure. The problem is further compounded by dendrite formation on the Li anode during electrochemical cycling leading to puncturing of the separator causing eventual short-circuiting of the cell and consequent heat generation resulting in major safety hazards of flammability of the organic liquid electrolyte and impending explosion. This chapter describes various approaches developed to combat both cathode and anode issues. These involve synthesis and characterization of complex framework materials (CFMs) for confining the polysulfides and sulfur in the LSB cathodes. The CFMs include a CFM host and a coating applied to the CFM host, which includes one or more form of an electronic conductor, a lithium-ion conductor and a functional electrocatalyst for electrocatalytically converting the soluble polysulfides to Li 2 S. Further, sulfur is infiltrated into the CFM host creating a sulfur-carbon linkage serving as effective anchors for trapping the ensuing polysulfides. The systems have been tested in coin cells and pouch cells with metallic Li anodes under lean electrolyte conditions of 3-4 μl/mg of electrolyte (E) to sulfur (S) ratios showing promise and feasibility. New emergent dendrite-free alloys have also been identified to test against pure Li and CFM cathodes in coin cell and pouch cell configurations under lean electrolyte conditions. Results of these studies are described and discussed with thoughts on future directions.

25 ENERGY STORAGE↗

Multi-Port Autonomous Reconfigurable Solar Power Plant

As the penetration level of power electronics increases and remote photovoltaic (PV) generation is integrated into the alternating current (ac) grid, the short-circuit ratio (SCR) at the point of interconnection of a hybrid PV–energy storage system (ESS) plant may be low. Additionally, the inertia of the alternating current (ac) grid may be low. The low SCRs and inertias can lead to reliability challenges in the power grid. These operating conditions require additional reinforcements, such as synchronous condensers, static var compensators, static synchronous compensators, and high-voltage direct current (HVdc) links/grids. HVdc links or grids may also provide the additional capability of connecting the plant to asynchronous grids and/or connecting asynchronous grids, among others. This scenario leads to discrete development of solar inverters, energy storage inverters, HVdc converters, and several transformers. Some of the problems associated with this discrete development and inverter-based generation include increased cost, lower reliability, and reduced efficiency associated with duplication of power electronics (PEs); competing controls of several individual discrete inverter-based generators due to the presence of multiple PEs, which leads to derating of the system; and transient stability problems arising from inverter-based generation, such as voltage/frequency events leading inverter shutdowns, voltage instability and control interactions in the formed weak grid, and harmonics caused by resonances of multiple inverters.

14 SOLAR ENERGY↗

Nondestructive Evaluation (NDE) of Cable Anomalies using Frequency Domain Reflectometry (FDR) and Spread Spectrum Time Domain Reflectometry (SSTDR)

This report presents a comparative assessment of the performance of frequency domain reflectometry (FDR) and spread spectrum time domain reflectometry (SSTDR) in detecting a wide range of electrical cable anomalies. All tests and results reported herein were performed at the PNNL Accelerated and Real-Time Environmental Nodal Assessment (ARENA) cable and motor test bed. The primary objective of this work was to evaluate the effectiveness of SSTDR, a fledgling cable monitoring technique that shows promise for application in online monitoring of energized cable systems, against FDR, an offline technique widely employed in the nuclear power plant (NPP) industry. FDR tests are becoming more widely used in nuclear power plant cable aging management and test programs – particularly for low voltage cables. FDR capabilities for these kinds of tests have been reported by PNNL and others. The FDR test is performed on de-energized cables by connecting the FDR instrument to two of the cable conductors, or one conductor and the shield. A broad band low voltage (< 5 V) chirp is introduced in the cable, and any reflected response is captured in the frequency domain. The captured reflection is then processed by performing an inverse Fourier transform to a time domain response which can then be converted to a distance response based on the cable velocity of propagation (VoP). SSTDR measurements are functionally similar to FDR measurements in that a broad-band voltage signal composed of a square or sine wave modulated pseudo-random sequence of chips (< 5 volts), is injected onto one of the cable conductors. The injected signal will experience partial energy reflection and transmission at each impedance discontinuity along the transmission line. Any reflected response is detected by computing a cross-correlation between the reflected signals and a delayed copy of the incident SSTDR signal. the time delay for the reflected signal to experience the best matched correlation with the incident signal, indicates the travel time for the signal to reach a change in impedance. By knowing this time delay and velocity of propagation (VoP) of the signal, one can compute the physical distance. A big advantage that SSTDR measurements have over other methods is the ability to be connected to energized or live wires (currently up to 1kV) thereby enabling online monitoring of cables. SSTDR has been used successfully in several applications, e.g., aircraft, rail, and photovoltaic systems. In this work FDR and SSTDR cable assessment techniques were used to characterize a variety of cable anomalies and faults including: (1) Presence or absence of a motor; (2) Ground faults and short circuit faults; (3) Moist environments and water ingress faults; (4) Accelerated thermal aging. Both shielded and non-shielded cables were evaluated in this report. Offline measurements were made using FDR and online measurements were made by SSTDR for a range of test scenarios. Based on the results across all cable anomalies evaluated in this study, FDR displayed high sensitivity towards cable condition assessment, while SSTDR showed promise for future application in monitoring NPP cable systems. However, further developments are suggested to improve the resolution and sensitivity of SSTDR towards faults and anomalies in low voltage cables.rt presents a comparative

42 ENGINEERING↗

Investigating Local Carrier Dynamics in PERC Patterned CdTe Solar Cells

Remarkable progress has been achieved in CdTe photovoltaics (PVs) to further improve cell performance while reducing manufacturing costs. Researchers optimized the front contact that leads the short-circuit current density (J sc ) over 31mA/cm 2 (e.g., (Zn, Mg)O buffer layer and/or alloying CdTe with Se). Reese et al. reported an open-circuit voltage (V oc ) over 1 V with group-V doped single crystal, showing the feasibility of increasing V oc in CdTe PV that is fixed to less than 900 mV in most cases. Recent studies suggested that the V oc improvement in polycrystalline CdTe PVs requires well-passivated back contact. One possible strategy is to use CdMgTe alloy (E g > 1.8 eV), where the band-gap offset (ΔE CB ≈ 0.2 eV) reflects minority carrier electrons, thereby decreasing surface recombination. Another strategy is to utilize a stable Al 2 O 3 layer as an electron reflector; experimental works confirmed the improved performance with a conformal Al 2 O 3 layer. In this configuration, the precise control of Al 2 O 3 (≈1 nm) over the entire CdTe layer is essential because the J sc greatly depends on the tunneling current. While promising, both CdMgTe and Al 2 O 3 passivation on CdTe introduce unfavorable valence band offset that blocks the hole transport. Kephart et al. proposed a patterned passixc vation layer (≈ 20 nm Al 2 O 3 ) with point contacts (≈ 3 μm in diameter) that extract hole carriers. This configuration is similar to the passive emitter and rear contact (PERC) design that has been extensively studied in Si PVs. While remarkably high carrier lifetime and photoluminescence (> 10 X) were measured, consistent improvement in V oc and efficiency in this CdTe PERC were not yet observed. At this time, it is unclear how the surface potential is distributed in the presence of patterned Al 2 O 3 reflectors and how this additional field impacts the PV performance for Cu-doped and group-V doped CdTe PERC devices. To tackle this challenge, we develop robust nanofabrication and characterization platform to study CdTe PERC devices consisting of a patterned Al 2 O 3 layer on CdSe( 1-x )Te x (Cu-doped, GrV-doped; x = 0 to 1; CST). First Solar supplies high-quality CST materials. The dark and light I-Vs under 1-sun illumination are extracted for a series of each set of devices. We perform quantitative and qualitative PV analysis for a series of Cu-doped and Gr-V doped PERC devices, showing notably different V oc changes for GrV-doped compared to Cu-doped PERC devices. This project attempts to produce individual contacts on single grains and grain boundaries to measure lateral transport. As a model system, we use a CdSe( 1-x )Te x film on glass prepared by a colossal grain growth (CGG) technique at National Renewable Research Laboratories (NREL). Our preliminary results confirm that intergranular transport is hindered by the electrical barrier formed near grain boundaries. The PERC fabrication and the lateral transport measurement platform developed in this project can easily be applied to other types of advanced CdSe( 1-x )Te x architectures to better understand local photocarrier transport, in turn, providing the fundamental knowledge to improve the performance of CdTe PVs.

14 SOLAR ENERGY↗

Flexible Transformers for Resilient and Adaptable Power Systems

This paper presents experience with grid ready flexible transformer unit, which is in service for two years without any difficulty. Transformer unit is capable of changing short circuit impedance on load and it is equipped with state-of-the-art monitoring system.

field validation↗

Contactless Production Testing of Silicon Solar Cells

Critical cost reductions in silicon solar cells are made by minimizing silver usage in their metal contacts. The reason why is both clear and unavoidable—silver is not only expensive, but also a potential limiting resource for scale-up (the PV industry alone used 10.3 % of the global silver supply in 2020 [1]). The result is solar cells with vanishing electrical contact area that are extremely difficult to test prior to module manufacture, when they must be sorted for quality to maximize power output and reliability of the subsequent modules. This project developed a new measurement instrument that enables the transition to solar cells with very low silver content, including cell designs with both minimal busbars and no busbars at all to electrically contact. The resulting instrument at project completion demonstrated the ability to sort cells with comparable—or better—results than existing technology. Compared to existing cell-test instruments, the new tool has minimal contacting requirements, which lowers the maintenance costs and use of consumable parts. We demonstrated innovative, yet pragmatic, solutions for reporting a comprehensive set of measurement results useful for both cell sorting (going forward in the line for module manufacture) and process control (looking backward in the line to identify cell manufacturing issues from wafer to cell-test). In addition to the traditional current-voltage characterization at cell test—short circuit current, open-circuit voltage, power, efficiency and fill factor—the new tool maintains all the advanced parameter characterization of our existing product line such as a substrate doping measurement, carrier recombination (lifetime) analysis, and surface recombination analysis.

14 SOLAR ENERGY↗

Gain of Object/Slot Array On Infinite Cylinder Operating At Fundamental Cavity Modes

This report examines the coupling into a circumferential slot array on an infinite cylinder with a finite length interior cavity operating at the fundamental cavity modal frequencies. The directivity gain associated with the interior cavity field is examined, and in this frequency range (as well as lower frequencies), is found to be enhanced by the exterior short circuit current variation with angle driving the slots.

42 ENGINEERING↗

Elucidating the Morphological Instability Mechanisms During Electrodeposition of Active Metals

The primary aim of this investigation is to elucidate the mechanisms by which a group of metals pertinent to battery technology exhibit unstable growth morphology during electrodeposition, which are crucial for the operational efficacy of batteries. The metals under consideration include alkali metals alongside zinc, all of which are characterized by high atomic mobility and reactivity with the electrolytes employed in battery systems. These materials represent promising electrode candidates for next-generation rechargeable batteries that are anticipated to deliver significantly enhanced energy density at a reduced cost. Nevertheless, the widespread occurrence of distinctly non-uniform morphologies, exemplified by the emergence of filamentous and moss-like structures, constitutes a significant impediment to their effective utilization, as it leads to accelerated capacity degradation and potential internal short circuits. This study addresses a critical question that has thus far garnered limited attention: Does the residual stress induced by the plating process play an instrumental role in inducing the morphological instability? Utilizing zinc as the primary model system, this project will be executed through three interconnected tasks: (1) the quantification of the relationship between plating stress and electroplating morphologies, (2) the three-dimensional imaging of the microstructure of the mossy structure at the nanoscale, and (3) the development of a mesoscale electroplating model to interpret empirical findings and generate additional predictive insights.

25 ENERGY STORAGE↗