Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

A Reconfigurable Planar Capacitor Sensor for Thru the Jacket Dielectric Constant Measurement of Cable Insulation

Planar capacitor sensors have been proposed to measure the aging-related dielectric constant variation of the jacket or insulation materials of cables. Although capacitor sensors have been used to monitor the aging of cable insulation by removing the jacket, through the jacket measurement of cable insulation dielectric constant variation is difficult because once the sensor is placed on the jacket it would either measure the aging of the jacket or that of the jacket and insulation together. A reconfigurable sensor along with innovative cable-specific models could be used to determine the jacket and insulation aging using the same sensor. For the proposed novel reconfigurable sensor, the electric field penetration depth is changed by activating and deactivating PIN diode switches. In one instance, the sensor measures the dielectric constant variation of the jacket, while in the next, it measures the dielectric constant variation of both the jacket and the insulation. Here, by leveraging previously developed capacitance estimation models from large-scale finite element simulations for a specific cable, these two sets of measurement data are used to evaluate the aging-related dielectric constant variation of the insulation. Experimental data from aged cable specimens are presented to demonstrate the operation of the sensor.

47 OTHER INSTRUMENTATION↗

SU-E-T-159: Characteristics of Fiber-Optic Radiation Sensor for Proton Therapeutic Beam

Purpose: A fiber-optic radiation sensor using Cerenkov radiation has been widely studied for use as a dosimeter for proton therapeutic beam. Although the fiber-optic radiation sensor has already been investigated for proton therapeutic, it has been examined relatively little work for clinical therapeutic proton beams. In this study, we evaluated characteristics of a fiber-optic radiation sensor for clinical therapeutic proton beams. We experimentally evaluated dose-rate dependence, dose response and energy dependence for the proton beam. Methods: A fiber-optic radiation sensor was placed in a water phantom. Beams with energies of low, middle and high were used in the passively-scattered proton therapeutic beam at the National Cancer Center in Korea. The sensor consists of two plastic optical fibers (POF). A reference POF and 2 cm longer POF were used to utilize the subtraction method for having sensitive volume. Each POF is optically coupled to the Multi-Anode Photo Multiplier Tube (MAPMT) and the MAPMT signals are processed using National Instruments Data Acquisition System (NI-DAQ). We were investigated dosimetric properties including dose-rate dependence, dose response and energy dependence. Results: We have successfully evaluated characteristics of a fiber optic radiation sensor using Cerenkov radiation. The fiber-optic radiation sensor showed the dose response linearity and low energy dependence. In addition, as the dose-rate was increased, Cerenkov radiation increased linearly. Conclusion: We evaluated the basic characteristics of the fiber optic radiation sensor, the dosimetry tool, to raise the quality of proton therapy. Based on the research, we developed a real time dosimetry system of the optic fiber to confirm the real time beam position and energy for therapeutic proton pencil beam.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP4-01: An Assessment of a Microsoft Kinect V2 Sensor for Voluntary Breath-Hold Monitoring in Radiotherapy

Purpose: To determine whether the Microsoft Kinect Version 2 (Kinect v2), a commercial off-the-shelf (COTS) depth sensors designed for entertainment purposes, were robust to the radiotherapy treatment environment and could be suitable for monitoring of voluntary breath-hold compliance. This could complement current visual monitoring techniques, and be useful for heart sparing left breast radiotherapy. Methods: In-house software to control Kinect v2 sensors, and capture output information, was developed using the free Microsoft software development kit, and the Cinder creative coding C++ library. Each sensor was used with a 12m USB 3.0 active cable. A solid water block was used as the object. The depth accuracy and precision of the sensors was evaluated by comparing Kinect reported distance to the object with a precision laser measurement across a distance range of 0.6m to 2.0 m. The object was positioned on a high-precision programmable motion platform and moved in two programmed motion patterns and Kinect reported distance logged. Robustness to the radiation environment was tested by repeating all measurements with a linear accelerator operating over a range of pulse repetition frequencies (6Hz to 400Hz) and dose rates 50 to 1500 monitor units (MU) per minute. Results: The complex, consistent relationship between true and measured distance was unaffected by the radiation environment, as was the ability to detect motion. Sensor precision was < 1 mm and the accuracy between 1.3 mm and 1.8 mm when a distance correction was applied. Both motion patterns were tracked successfully with a root mean squared error (RMSE) of 1.4 and 1.1 mm respectively. Conclusion: Kinect v2 sensors are capable of tracking pre-programmed motion patterns with an accuracy <2 mm and appear robust to the radiotherapy treatment environment. A clinical trial using Kinect v2 sensor for monitoring voluntary breath hold has ethical approval and is open to recruitment. The authors are supported by a National Institute of Health Research (NIHR) Career Development Fellowship (CDF-2013-06-005). Microsoft Corporation donated three sensors. The views expressed in this publication are those of the author(s) and not necessarily those of the NHS, the National Institute for Health Research or the Department of Health.

60 APPLIED LIFE SCIENCES↗

Digital acoustic sensor performance across the infrasound range in non-isolated conditions

The next generation of acoustic sensors is emerging to supplement legacy sensors traditionally used in regional and global networks. These devices operate under similar principles as traditional sensors, without the need of a separate external digitizer. The calibration of these sensors against their predecessors is crucial to the modernization of conventional technologies. This work describes the characterization of the next-generation MB3 digital microbarometer and the iPrecision smartphone microphone in a non-isolated calibration room across the infrasound (i.e., 0.01–20 Hz) range. The intent is to evaluate nominal instrument performance before deployment. A portable rotary subwoofer is used as a controllable infrasound source to generate single-tone sinusoidal and broadband noise pressure waves in a room configured for calibration purposes. For each device, comparison measurements are made, from which the digital sensitivity and the parametric response is developed. The results provide insight into the performance of the sensors in non-isolated environments. By overlapping the responses of the test sensors, digital sensor performance across the infrasound range can be benchmarked. These responses may serve as a double-reference scheme in future pressure measurements and digital calibrations of acoustic sensors.

47 OTHER INSTRUMENTATION↗

Impact of pulse thermal processing on the properties of inkjet printed metal and flexible sensors

In this paper, we report on the low temperature processing of environmental sensors employing pulse thermal processing (PTP) technique to define a path toward flexible sensor technology on plastic, paper, and fabric substrates. Inkjet printing and pulse thermal processing technique were used to realize mask-less, additive integration of low-cost sensors on polymeric substrates with specific focus on temperature, humidity, and strain sensors. The printed metal line performance was evaluated in terms of the electrical conductivity characteristics as a function of post-deposition thermal processing conditions. The PTP processed Ag metal lines exhibited high conductivity with metal sheet resistance values below 100 mΩ/{whitesquare} using a pulse width as short as 250 μs. The flexible temperature and relative humidity sensors were defined on flexible polyimide substrates by direct printing of Ag metal structures. The printed resistive temperature sensor and capacitive humidity sensor were characterized for their sensitivity with focus on future smart-building applications. Strain gauges were printed on polyimide substrate to determine the mechanical properties of the silver nanoparticle films. Finally, the observed electrical properties of the printed metal lines and the sensitivity of the flexible sensors show promise for the realization of a high performance print-on-demand technology exploiting low thermal-budget PTP technique.

36 MATERIALS SCIENCE↗

Response Characteristics of a Stable Mixed Potential Ammonia Sensor in Simulated Diesel Exhaust

A mixed potential sensor using Au and Pt dense wire electrodes embedded between tape-casted layers of 8 mol% yttria stabilized zirconia (YSZ) was tested for application toward NH 3 , NO, NO 2 , C 3 H 6 and C 3 H 8 . In single-gas testing, the sensor exhibited the highest response toward NH 3 , while still exhibiting reasonably high sensitivity toward other interferent gases. We tested the sensor in a high-flow reactor at the National Transportation Research Center (NTRC) in order to simulate exhaust gas constituents and flow rates produced by lean-burn vehicles powered by Compression-Ignition Direct-Injection (CIDI), diesel engines. The sensor was characterized at 525 and 625°C for NH 3 , CO, C 3 H 6 , C 3 H 8 , and NO x in a base gas composition of 10% O 2 , 5% H 2 O, and 5% CO 2 flowing at 15 slpm. The sensor exhibited fast response time equal to the response time of the system's switching valve (T90<0.6s). Furthermore, in simulations of overdosing a selective catalytic reduction (SCR) system, the sensor was able to selectively respond to 20ppm injections of NH 3 slip despite the presence of the interferent gas species at combined concentrations ten times higher than that of the NH 3 . The laboratory sensor construct was transitioned to a pre-commercial, automotive stick sensor configuration that was demonstrated to retain the advantageous characteristics of the tape-cast device.

33 ADVANCED PROPULSION SYSTEMS↗

Three-Component Spectroelectrochemical Sensor Module for the Detection of Pertechnetate (TcO4-)

This review looks at the advancements in the development of a sensor for technetium (Tc) that is applicable to characterizing and monitoring the vadose zone and associated subsurface water. Subsurface contamination by Tc is of particular concern for two reasons: the extremely long lifetime of its most common isotope 99Tc (half-life = 2 x 105 years) and the fast migration in soils of pertechnetate (TcO4–) which is considered to be the dominant 99Tc species in ground water. TcO4– does not have a characteristic spectral signature which prevents its rapid, sensitive, and economic in-situ detection. To address this problem, a novel spectroelectrochemical sensor has been designed that combines three modes of selectivity (electrochemistry, spectroscopy, and selective partitioning) into a single sensor to substantially improve specificity which is critical in the specific detection of an analyte in the presence of potential interfering species. The sensor consists of a basic spectroelectrochemical configuration: a waveguide with an optically transparent electrode (OTE) that is coated with a thin chemically-selective film that preconcnetrates the analyte. The key to adapting this generic sensor to detect TcO4– and Tc complexes lies in the development of chemically-selective films that preconcentrate the analyte and, when necessary, chemically convert it into a complex with electrochemical and spectroscopic properties appropriate for sensing. This review focuses on the general concept of the sensor and the rationale for the selection of the specific components of choice, the development and characterization of the sensor for the different detection modules, the synthesis and characterization of complexes relevant in the detection of technetium, and the progress in the utilization of the sensor module for the effective detection of these complexes.

Environmental Molecular Sciences Laboratory↗

Data and Scripts associated with: “Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy”

This data package is associated with the publication “Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy: How do they compare?” submitted to PLOS ONE and accepted for publication (Fulton, S.G. et al. 2023; doi not yet available).Variation in electrical conductivity (EC) of water is important to reveal environmental disturbance and natural dynamics, including factors such as anthropogenic salinization. This data package supports a study addressing the need for a robust performance assessment of open source (OS) EC sensors. We evaluated the accuracy (mean error, %) and precision (sample standard deviation) of OS EC sensors in the laboratory via comparison to EC calibration standards using three different OS and OS/commercial-hybrid (OS/C) EC sensors and data logger configurations and two commercial (C) EC sensors and data logger configurations. We also evaluated the effect of cable length (7.5 m and 30 m) and sensor calibration on OS sensor accuracy and precision. This data package presents the results from the different testing laboratory configurations. It also includes an R script for statistical analysis of the data and an Arduino IDE file used to calibrate and collect data with the OS Atlas EC sensor. File types are .csv, .pdf, .R, and .ino.

54 ENVIRONMENTAL SCIENCES↗

Integration Testing of Ultrasonic Deformation Sensor for TREAT Experiments

Fuel deformation (both axial and radial) information provides insights into fuel performance and failure limits. Traditionally, fuel deformation has been quantified using post-irradiation examinations due to the lack of an appropriate sensor for monitoring deformation in situ. Recent developments in sensor and instrumentation design have led to the use of linear variable differential transformers (LVDT) for monitoring axial strain in fuel during irradiation. Size and operational constraints limit the use of LVDT sensors for radial deformation monitoring, and alternatives are needed. One possible alternative to LVDT sensors is an ultrasonic sensor. Ultrasonic sensors monitor the interaction of high-frequency stress waves with the test object. The resulting response may be analyzed to determine the properties of the material, including stress, strain, microstructure, presence of defects, and the elastic constants. While ultrasonic measurements have been successfully applied for monitoring strain in a number of applications, their use for in-core measurements has been limited. Largely, the limitations are due to the challenges associated with designing sensors that can operate under typical in-core conditions. This report documents testing performed to confirm that the prototypic ultrasonic deformation sensor can be integrated into TREAT irradiation experiments using the SETH capsule.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Second Annual Progress Report on Ultrasonic Sensors for TREAT Fuel Condition Measurement and Monitoring

Fuel deformation (both axial and radial) information provides insights into fuel performance and failure limits. Traditionally, fuel deformation has been quantified using post-irradiation examinations due to the lack of an appropriate sensor for monitoring deformation in situ. Recent developments in sensor and instrumentation design have led to the use of linear variable differential transformers (LVDT) for monitoring axial strain in fuel during irradiation. Size and operational constraints limit the use of LVDT sensors for radial deformation monitoring, and alternatives are needed. One possible alternative to LVDT sensors is an ultrasonic sensor. Ultrasonic sensors monitor the interaction of high-frequency stress waves with the test object. The resulting response may be analyzed to determine the properties of the material, including stress, strain, microstructure, presence of defects, and the elastic constants. While ultrasonic measurements have been successfully applied for monitoring strain in a number of applications, their use for in-core measurements has been limited. Largely, the limitations are due to the challenges associated with designing sensors that can operate under typical in-core conditions. The overall objective of this work is to design an ultrasonic sensor capable of rapid in-situ measurements of fuel rodlet dimensional changes during TREAT transient irradiation testing. This report summarizes the activities and research findings through the end of Year 2 of this three-year project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-Sodium Testing of a Prototype Thermoacoustic Power Sensor for Sodium-Cooled Fast Reactors

The ultimate goal of this project is to develop and demonstrate a thermoacoustic power sensor (TAPS) for Sodium-Cooled Fast Reactors (SFRs), with potential application also envisioned to other nuclear technologies such as Lead-Cooled Fast Reactors (LFRs), Molten Salt Reactors (MSRs), in addition to Light Water Reactors (LWRs). The project was led by Westinghouse Electric Company, LLC (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and the University of Pittsburgh. A TAPS is a passive (self-powered), non-invasive (wireless) sensor envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. The sensor generates pressure waves (i.e., sound waves) with a frequency and amplitude dependent upon nuclear operating conditions (coolant temperature or power changes). The acoustic waves are able to travel through the core and associated structures, and reach to the sensor network placed outside and/or inside of the reactor vessel. These sensors require a very small amount of power which, during loss of power events, can be provided, for example, by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. Westinghouse and the University of Pittsburgh designed and fabricated TAPS prototypes for Argonne National Laboratory (ANL) to carry out in-sodium testing to evaluate the effects of sodium on the TAPS and the performance of the TAPS technique in sodium. Argonne received a TAPS prototype from Westinghouse, and the prototype was modified such that it can be installed into a test vessel and function in sodium at elevated temperature without potentially leaking. A water mockup test apparatus was constructed to validate proper working of the prototype. An instrumentation and control (I&C) system, running on the National Instruments (NI) LabView platform, was developed to: 1) operate both the water mockup test and the in-sodium test facility; and 2) process and analyze the received acoustic signals from an array of accelerometers and the Argonne sodium-submersible high-temperature acoustic sensor. The prototype was successfully tested in a water bath at different temperatures. Water mockup tests demonstrated that the TAPS prototype is working properly and its resonance frequency changes linearly with the coolant (water) temperature. A TAPS test apparatus was constructed and integrated with the upgraded Under-Sodium Viewing (USV) sodium test facility. The integrated USV-TAPS sodium test facility has been operational. The TAPS prototype and a high-temperature sodium-submersible acoustic sensor (SSAS) developed by Argonne were both installed inside the TAPS test vessel. Being operated within argon cover gas under ambient conditions, the TAPS prototype demonstrated that it was functioning properly with a resonance frequency at 1407.2 Hz, which was successfully detected by the accelerometers mounted on the external wall of the vessel and the high-temperature SSAS installed inside the vessel. After successfully transferring sodium into the vessel, in-sodium tests of the prototype were conducted. Tests of the TAPS prototype demonstrated that the resonance frequency of the TAPS changes linearly with respect to the temperature difference between the interior of the TAPS and bulk sodium. The early tests showed that the TAPS prototype could not establish a continuous and consistent resonance in sodium. The resonance diminished before the prototype reached its operating temperature. A signal postprocessor was added to the DAQ module latterly to isolate interferences, enhance signal conditioning, improve peak detection, and generate resonance frequency versus temperature plots. After testing in molten sodium and immersion at higher temperature for several weeks, the TAPS prototype was able to establish a continuous resonance. Performance evaluation of the TAPS prototype was then conducted in sodium. The tests included the investigation of 1) the effects of the temperature difference between the TAPS and bulk sodium, 2) the effects of sodium flowrate; and 3) the performance of the different sensor-receiver systems positioned inside or outside the vessel. Results of a test demonstrated that, with limited sodium circulation, a continuous and consistent resonance of the TAPS prototype was established occasionally. The tests also demonstrated that, because of the nature of detection principles and mounting methods, the high temperature SSAS is more affected by acoustic noise, while accelerometers are more affected by vibrations, in the test environment. It is unknown why the TAPS prototype only occasionally established a continuous and consistent resonance when the TAPS temperature reached its operating temperature in molten sodium, and why it ultimately failed to resonate at all. A failure modes assessment was conducted and a few potential causes of failure were identified. Different post in-sodium tests were conducted to obtain additional information potentially relevant to the cause of the failure. Nondestructive evaluation techniques are suggested to examine the internal integrity as well as the gas mixture of the prototype. If they prove inconclusive, the prototype should be cut open to conduct a thorough inspection of its internal integrity and determine the state of the gas mixture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AOI [1] Advanced Manufacturing of Ceramic Anchors with Embedded Sensors for Process and Health Monitoring of Coal Boilers

Researchers at West Virginia University (WVU) developed methods to fabricate and test ceramic anchors with an embedded sensor technology for monitoring the health and processing conditions within pulverized coal (PC) and fluidized-bed combustion (FBC) boiler systems. The technology included the development of advanced manufacturing processes for 2D/3D printing electroceramic (conductive ceramic) sensor designs within the ceramic anchor microstructure during the manufacturing process. This advanced manufacturing process would allow for the precise control of local microstructure and composition in order to engineer layer-by-layer any protective and electrically active materials within the refractory anchor. This 3D printing technology would permit the rapid and controlled design of the refractory microstructure and embedded sensor design throughout the volume of the ceramic anchor. The work also included a method to interconnect the sensors to boiler shell through the anchor clamp, where the sensor signals will be processed by low-power electronics and transmitted wirelessly to a central processing hub. The end-goal of the program was to produce a ceramic anchor sensor system which would be ready for implementation within a coal boiler, and/or other similar refractory liner systems (such as that in the glass and metal manufacturing areas). The project objectives were to: 1) Define the chemical and microstructural stability, in addition to the electrical properties, of oxide and non-oxide ceramic composites to be embedded within the ceramic anchor compositions that may operate up to 1400ºC; 2) Develop and implement the 2D/3D printing technology to pattern and control the microstructure of the ceramic anchor and embedded sensor circuits; 3) Develop an interconnect technology which will permit easy installation of the ceramic anchors and signal collection at the boiler shell; 4) Develop low power analog electronics and wireless communication hardware to efficiently collect the sensor signal at each processing unit and transmit data to a central hub for data analysis; 5) Demonstrate the smart ceramic anchor system for temperature and liner fracture within a high-temperature processing unit, such as a boiler furnace or glass melting furnace floor/wall liner.

20 FOSSIL-FUELED POWER PLANTS↗

Comparing the Use of High- to Low-Cost Black Carbon and Carbon Dioxide Sensors for Characterizing On-Road Diesel Truck Emissions

The exhaust plume capture method is a commonly used approach to measure pollutants emitted by in-use heavy-duty diesel trucks. Lower cost sensors, if used in place of traditional research-grade analyzers, could enable wider application of this method, including use as a monitoring tool to identify high-emitting trucks that may warrant inspection and maintenance. However, low-cost sensors have for the most part only been evaluated under ambient conditions as opposed to source-influenced environments with rapidly changing pollutant concentrations. This study compared black carbon (BC) emission factors determined using different BC and carbon dioxide (CO 2 ) sensors that range in cost from $200 to $20,000. Controlled laboratory experiments show that traditional zero and span steady-state calibration checks are not robust indicators of sensor performance when sampling short duration concentration peaks. Fleet BC emission factor distributions measured at two locations at the Port of Oakland in California with 16 BC/CO 2 sensor pairs were similar, but unique sensor pairs identified different high-emitting trucks. At one location, the low-cost PP Systems SBA-5 agreed on the classification of 90% of the high emitters identified by the LI-COR LI-7000 when both were paired with the Magee Scientific AE33. Conversely, lower cost BC sensors when paired with the LI-7000 misclassified more than 50% of high emitters when compared to the AE33/LI-7000. Confidence in emission factor quantification and high-emitter identification improves with larger integrated peak areas of CO 2 and especially BC. This work highlights that sensor evaluation should be conducted under application-specific conditions, whether that be for ambient air monitoring or source characterization.

47 OTHER INSTRUMENTATION↗

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping

The reliability of computational fluid dynamics (CFD) codes is checked by comparing simulations with experimental data. A typical data set consists chiefly of velocity and temperature readings, both ideally having high spatial and temporal resolution to facilitate rigorous code validation. While high resolution velocity data is readily obtained through optical measurement techniques such as particle image velocimetry, it has proven difficult to obtain temperature data with similar resolution. Traditional sensors such as thermocouples cannot fill this role, but the recent development of distributed sensing based on Rayleigh scattering and swept-wave interferometry offers resolution suitable for CFD code validation work. Thousands of temperature measurements can be generated along a single thin optical fiber at hundreds of Hertz. Sensors function over large temperature ranges and within opaque fluids where optical techniques are unsuitable. But this type of sensor is sensitive to strain and humidity as well as temperature and so accuracy is affected by handling, vibration, and shifts in relative humidity. Such behavior is quite unlike traditional sensors and so unconventional installation and operating procedures are necessary to ensure accurate measurements. This paper demonstrates implementation of a Rayleigh scattering-type distributed temperature sensor in a thermal mixing experiment involving two air jets at 25 and 45 °C. We present criteria to guide selection of optical fiber for the sensor and describe installation setup for a jet mixing experiment. We illustrate sensor baselining, which links readings to an absolute temperature standard, and discuss practical issues such as errors due to flow-induced vibration. This material can aid those interested in temperature measurements having high data density and bandwidth for fluid dynamics experiments and similar applications. We highlight pitfalls specific to these sensors for consideration in experiment design and operation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of Electrical Capacitance Sensors for Accident Tolerant Fuel (ATF) Testing at the Transient Reactor Test (TREAT) Facility

A variety of instruments are being developed and qualified to support the Accident Tolerant Fuels (ATF) program and future transient irradiations at the Transient Reactor Test (TREAT) facility at Idaho National Laboratory (INL). The University of New Mexico (UNM) is working with INL to develop capacitance-based void sensors for determining the timing of critical boiling phenomena in static capsule fuel testing and the volume-averaged void fraction in flow-boiling in-pile water loop fuel testing. The static capsule sensor developed at INL is a plate-type configuration, while UNM is utilizing a ring-type capacitance sensor. Each sensor design has been theoretically and experimentally investigated at INL and UNM. Experiments are being performed at INL in an autoclave to investigate the performance of these sensors under representative Pressurized Water Reactor (PWR) conditions in a static capsule. Experiments have been performed at UNM using air-water two-phase flow to determine the sensitivity and time response of the capacitance sensor under a flow boiling configuration. Initial measurements from the capacitance sensor have demonstrated the validity of the concept to enable real-time measurement of void fraction. The next steps include designing the cabling interface with the flow loop at UNM for Reactivity Initiated Accident (RIA) ATF testing at TREAT and further characterization of the measurement response for each sensor under varying conditions by experiments and modeling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Virtual sensors for robust on-line monitoring (OLM) and Diagnostics

Unscheduled shutdown of nuclear power facilities for recalibration and replacement of faulty sensors can be expensive and disruptive to grid management. In this work, we present virtual (software) sensors that can replace a faulty physical sensor for a short duration thus allowing recalibration to be safely deferred to a later time. The virtual sensor model uses a Gaussian process model to process input data from redundant and other nearby sensors. Predicted data includes uncertainty bounds including spatial association uncertainty and measurement noise and error. Using data from an instrumented cooling water flow loop testbed, the virtual sensor model has predicted correct sensor measurements and the associated error corresponding to a faulty sensor.

Analytical study↗

Virtual sensors for robust on-line monitoring (OLM) and diagnostics - 197

Unscheduled shutdown of nuclear power facilities for recalibration and replacement of faulty sensors can be expensive and disruptive to grid management. In this work, we present virtual (software) sensors that can replace a faulty physical sensor for a short duration thus allowing recalibration to be safely deferred to a later time. The virtual sensor model uses a Gaussian process model to process input data from redundant and other nearby sensors. Predicted data includes uncertainty bounds including spatial association uncertainty and measurement noise and error. Using data from an instrumented cooling water flow loop test bed, the virtual sensor model has predicted correct sensor measurements and the associated error corresponding to a faulty sensor. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Condition monitoring and false alarm reducing of sensors in NPP - 222

With more and more application of digital I and C systems in nuclear power plants (NPP), more and more sensors are also required. Large amount of sensors really can make contribution to the condition monitoring of systems and equipment in NPP, whereas the heavy use also increases the malfunction risk of sensor self. Therefore the reliability and effectiveness of sensors must be guaranteed first. Thus the condition of sensors should be monitored first in a NPP. Since the precise mathematical models of sensors in complex systems are relative difficult to establish, however quantity of operating data can be easily obtained due to the wide application of digital I and C systems, thus this article adopts principal component analysis (PCA) to carry out condition monitoring for sensors. The PCA model developed for sensors is proved to be effective with operating data acquired from a real NPP. It can detect and isolate the fault when an artificial fault is imposed to the normal data. Then the monitoring results are further processed by another control limit (second confidence limit) besides T 2 and Q statistics (first confidence limit) in PCA. The value of second confidence limit is calculated based on the probability statistics of T 2 and Q statistics. And simulation tests show that the application of the second confidence limit can greatly reduce false alarms in the PCA model and the model performance can be greatly improved with the application of false alarms reducing method. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗