Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Incorporating Quantitative Single Photon Emission Computed Tomography into Radiation Therapy Treatment Planning for Lung Cancer: Impact of Attenuation and Scatter Correction on the Single Photon Emission Computed Tomography-Weighted Mean Dose and Functional Lung Segmentation

Purpose: To assess the impact of attenuation and scatter corrections on the calculation of single photon emission computed tomography (SPECT)-weighted mean dose (SWMD) and functional volume segmentation as applied to radiation therapy treatment planning for lung cancer. Methods and Materials: Nine patients with lung cancer underwent a SPECT lung perfusion scan. For each scan, four image sets were reconstructed using the ordered subsets expectation maximization method with attenuation and scatter corrections ranging from none to a most comprehensive combination of attenuation corrections and direct scatter modeling. Functional volumes were segmented in each reconstructed image using 10%, 20%, ..., 90% of maximum SPECT intensity as a threshold. Systematic effects of SPECT reconstruction methods on treatment planning using functional volume were studied by calculating size and spatial agreements of functional volumes, and V{sub 20} for functional volume from actual treatment plans. The SWMD was calculated for radiation beams with a variety of possible gantry angles and field sizes. Results: Functional volume segmentation is sensitive to the particular method of SPECT reconstruction used. Large variations in functional volumes, as high as >50%, were observed in SPECT images reconstructed with different attenuation/scatter corrections. However, SWMD was less sensitive to the type of scatter corrections. SWMD was consistent within 2% for all reconstructions as long as computed tomography-based attenuation correction was used. Conclusion: When using perfusion SPECT images during treatment planning optimization/evaluation, the SWMD may be the preferred figure of merit, as it is less affected by reconstruction technique, compared with threshold-based functional volume segmentation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and Testing of a Novel Wide Range - Segmented Gamma Scanner Incorporating Tomographic Gamma Scanning for Measuring Both Low and Intermediate Level Waste in Drums - 13470

This paper describes the design and testing of a novel automated Wide Range Segmented Gamma ray Scanning (WR-SGS) assay instrument that also incorporates Tomographic Gamma Scanning (TGS). The instrument is designed for the measurement of both Low and Intermediate Level Waste (LLW and ILW) in 200 litre drums and other waste containers covering a wide range of density. Like earlier ANTECH WR-SGS instruments, the system employs a single shielded and collimated high purity germanium (HPGe) detector to quantify the radionuclide content of the waste and like conventional SGS instruments it is suitable for the measurement of relatively homogeneous waste matrices. Also, like earlier WR-SGS systems the instrument incorporates an automated variable aperture collimator, which allows the vertical segment height to be adjusted in order to measure both high dose-rate and very low activity drums. The instrument employs both conventional discrete SGS vertical segment measurements as well as vertical segment measurement by continuous helical-scanning of the drum as it rotates. This latter method reduces measurement times for SGS measurements. In order to determine the density corrections for both low and high-density drums, a high activity Eu-152 transmission source is employed. When not in use, and in place of a conventional shutter mechanism, the shielded transmission source is moved to a shielded storage position to eliminate background radiation from the source. Due to its novel features, the WR-SGS is applicable to the measurement of both very low and very high activity waste drums as well as waste drums with a wide range of density. If located in a low background position and with the effective shielding of the strong transmission source, the instrument can be used to measure very low level or exempt waste. In order to extend the range of applicability to the measurement of heterogeneous drums, TGS measurement capability has been included in the basic WR-SGS design. This is achieved by adding horizontal motion to the waste drum rotation platform and incorporating TGS collimation into the variable aperture collimator, as well as a filter to reduce the detector signal when straight-through measurements are made using the strong transmission source. Test measurements are presented of the system operating in both SGS and TGS modes using different drum densities and source strengths. The test measurement results are compared with benchmarked MCNP Monte Carlo calculations. The Wide Range SGS - TGS instrument extends the range of both activity and density that can be measured in 200 and 340 litre drums. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Compressible Arch Segments for the Cigeo Access Ramps, Drifts and Vaults - A Field Test - 17011

Andra is currently implementing the detailed engineering phase of the step-wise design development of Cigeo (the French HLW and IL-LLW Deep Geological Repository). Various technical issues are at stake, including the requirements linked to 'Reversibility / Retrievability', at different stages of the repository life cycle (from its construction start-up to its final closure and monitoring). These reversibility requirements have a significant impact on the way Cigeo is designed, will be progressively developed, operated, later closed and monitored. On a shorter term, one must demonstrate that the waste container retrieval operations are technically safe and feasible. In that sense, the structural dimensioning of the ramps and mains, as well as that of the IL-LLW disposal vaults, is critical, since the concrete liner supporting the rock walls must last over a period of some 100 to 150 years (lapse of time during which retrieval operations are likely to take place). The present paper starts with a description of the geomechanical conditions prevailing in the Callovo-Oxfordian (COX) clay-stone formation (aka the argillite). The structural dimensioning of the IL-LLW disposal vault liner, as calculated at the end of the basic engineering phase is indicated. The thickness values obtained so far have led to considering an alternative design in which a compressible material is positioned between the concrete liner intrados and the rock walls: in such situation, the 'creeping effect' of the rock is mitigated, for a time, by the compressible material (nearly a perfect elastoplastic material), hence reducing the stress level exerted inside the concrete liner. This situation enables to significantly reduce the liner thickness and provides potentially significant saving in the construction of the works concerned (preliminary sensitivity results are given). The following part of the paper is then focused on a practical case story: a technological demonstration (still ongoing) of a tunnel boring experiment, implemented underground (in a dedicated drift of the Meuse Haute Marne URL infrastructures, at scale 1:2 of the Cigeo drifts/vaults). In this excavation and construction experiment, the tunnel boring machine (TBM) lays (via an erector) 'classical' concrete arch segments (forming a ring) in a first portion of the drift and 'compressible' ones (the compressible material is positioned on their extrados) in a second portion of the drift. The technical demonstration objective is two-fold: the capacity to lay compressible arch segments with a TBM is checked, their structural behavior (with time) is compared with that of 'classical' ones. The way the compressible material is produced and then fixed on the arch concrete segment is also documented, c/w a description of the complementary testing campaign to be carried out on a test bench (on surface) of a concrete ring (at a scale 1:2 of Cigeo) formed of compressible arch segments. This paper concludes with a timeline of the experiment. Should the results obtained provide some perspectives of technical and economic improvement (i.e. saving vis-a-vis the 'classical' solution) a decision could be taken by Andra to incorporate this alternative solution in the 'design freeze' of Cigeo underground infrastructures. The positive outcomes of this technical test campaign would also pave the way for specifying the Cigeo TBM characteristics (dimensions and handling equipment), scheduled for manufacturing order around 2020. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Adaptive Patching for High-resolution Image Segmentation with Transformers

Attention-based models are proliferating in the space of image analytics, including segmentation. The standard method of feeding images to transformer encoders is to divide the images into patches and then feed the patches to the model as a linear sequence of tokens. For high-resolution images, e.g. microscopic pathology images, the quadratic compute and memory cost prohibits the use of an attention-based model, if we are to use smaller patch sizes that are favorable in segmentation. The solution is to either use custom complex multi-resolution models or approximate attention schemes. We take inspiration from Adapative Mesh Refinement (AMR) methods in HPC by adaptively patching the images, as a pre-processing step, based on the image details to reduce the number of patches being fed to the model, by orders of magnitude. This method has a negligible overhead, and works seamlessly with any attention-based model, i.e. it is a pre-processing step that can be adopted by any attention-based model without friction. We demonstrate superior segmentation quality over SoTA segmentation models for realworld pathology datasets while gaining a geomean speedup of 6.9× for resolutions up to 64K2, on up to 2, 048 GPUs.

Zhang, Enzhi↗

Uncertainty-refined image segmentation under domain shift

Digital image segmentation is provided. The method comprises training a neural network for image segmentation with a labeled training dataset from a first domain, wherein a subset of nodes in the neural net are dropped out during training. The neural network receives image data from a second, different domain. A vector of N values that sum to 1 is calculated for each image element, wherein each value represents an image segmentation class. A label is assigned to each image element according to the class with the highest value in the vector. Multiple inferences are performed with active dropout layers for each image element, and an uncertainty value is generated for each image element. Uncertainty is resolved according to expected characteristics. The label of any image element with an uncertainty above a threshold is replaced with a new label corresponding to a segmentation class based on domain knowledge.

Martinez, Carianne↗

SAR Imagery Segmentation by Statistical Region Growing and Hierarchical Merging

This paper presents an approach to accomplish synthetic aperture radar (SAR) image segmentation, which are corrupted by speckle noise. Some ordinary segmentation techniques may require speckle filtering previously. Our approach performs radar image segmentation using the original noisy pixels as input data, eliminating preprocessing steps, an advantage over most of the current methods. The algorithm comprises a statistical region growing procedure combined with hierarchical region merging to extract regions of interest from SAR images. The region growing step over-segments the input image to enable region aggregation by employing a combination of the Kolmogorov-Smirnov (KS) test with a hierarchical stepwise optimization (HSWO) algorithm for the process coordination. We have tested and assessed the proposed technique on artificially speckled image and real SAR data containing different types of targets.

42 ENGINEERING↗

A faster-converging algorithm for image segmentation with a modified Chan-Vese model

We propose an algorithm for segmentation of grayscale images. Our algorithm computes a solution to the convex, unconstrained minimization problem proposed by T. Chan., S. Esedoglu, and M. Nikolova in [1], which is closely related to the Chan-Vese level set algorithm for the Mumford-Shah segmentation model. Up to now this problem has been solved with a gradient descent method. Our approach is a quasi-Newton method based on the lagged diffusivity algorithm [2] for minimizing the total-variation functional for image denoising [3]. Our results show that our algorithm requires a much smaller number of iterations and less time to converge than gradient descent, and is able to segment noisy images correctly.

97 MATHEMATICS AND COMPUTING↗

A VR-based volumetric medical image segmentation and visualization system with natural human interaction

Volume rendering produces informative two-dimensional (2D) images from a 3-dimensional (3D) volume. It highlights the region of interest and facilitates a good comprehension of the entire data set. However, volume rendering faces a few challenges. First, a high-dimensional transfer function is usually required to differentiate the target from its neighboring objects with subtle variance. Unfortunately, designing such a transfer function is a strenuously trial-and-error process. Second, manipulating/visualizing a 3D volume with a traditional 2D input/output device suffers dimensional limitations. To address all the challenges, we design NUI-VR 2 , a natural user interface-enabled volume rendering system in the virtual reality space. NUI-VR 2 marries volume rendering and interactive image segmentation. It transforms the original volume into a probability map with image segmentation. A simple linear transfer function will highlight the target well in the probability map. More importantly, we set the entire image segmentation and volume rendering pipeline in an immersive virtual reality environment with a natural user interface. NUI-VR 2 eliminates the dimensional limitations in manipulating and perceiving 3D volumes and dramatically improves the user experience.

42 ENGINEERING↗

Paw-Net: Stacking ensemble deep learning for segmenting scanning electron microscopy images of fine-grained shale samples

Segmentation of scanning electron microscopy (SEM) images is critical yet time-consuming for geological analyses, as it needs to differentiate the boundaries for different mineral objects to facilitate subsequent analyses, such as porosity calculation. Recently, various machine learning methods, especially convolutional neural networks (CNNs), have been explored to segment SEM images of fine-grained shale samples. However, we found that general CNNs do not yield optimal performance due to insufficient training data and imbalanced objects in SEM images. This work has revised the U-Net architecture, a popular approach for biomedical image analyses, by incorporating a loss function that addresses the imbalance issue. Furthermore, we used the ensemble learning method to train multiple models and combined the results to improve the overall performance of segmentation. We prepared 2162 sub-images from raw SEM images in our experiments and divided them into training, validation, and testing datasets. The overall results show that our method improves the average Intersection over Union (IOU) of mineral objects from 0.49 to 0.58, compared to the original U-Net model. Our method can clearly distinguish each object from others with boundaries, even in highly imbalanced images. Training our models takes less than three minutes using a single GPU, while manual labeling can take up to three hours for each image. Furthermore, the method helps geoscientists gain insights quickly and effectively by building neural network models from a small dataset of SEM images.

58 GEOSCIENCES↗

A mesoscale 3D model of irradiated concrete informed via a 2.5 U-Net semantic segmentation

The concrete biological shield in light-water reactors is exposed to neutron and gamma irradiation, which deteriorates the concrete’s mechanical properties in the long term. To assess the irradiation-induced damage, predictive mechanical models are developed and used in parallel with the characterization of irradiated concrete samples. Realistic 3D simulation domains can drastically improve a model’s prediction. In this work, we utilized x-ray computed tomography (XCT) data of a concrete specimen to reconstruct its 3D microstructure. The XCT data shows low contrast between the concrete’s aggregates and cement paste, resulting in poor image segmentation when using traditional unsupervised techniques. To address this issue, we developed and trained a 2.5D U-Net model on only 24 pre-labeled XCT layers to segment 651 layers of the XCT data. The overall F1-score of the model is approximately 96%. Then, we created a 3D finite element (FE) mesh based on the stack of segmented images. The FE model contains radiation-induced expansion, damage, and creep. The constitutive equations are adapted to each phase (aggregates and cement paste). Here, we simulated the effects of neutron irradiation in the concrete specimen as well as the specimen’s mechanical response to uniaxial compression. Finally, model validation was performed using experimental data on similar concrete specimens in the literature.

2.5D U-Net↗

NuSD: A Geant4 based simulation framework for segmented anti-neutrino detectors

NuSD: Neutrino Segmented Detector is a Geant4-based user application that simulates inverse beta decay event in a variety of segmented scintillation detectors developed by different international collaborations. This simulation framework uses a combination of cross-programs and libraries including Geant4, ROOT and CLHEP developed and used by high energy physics community. It will enable the neutrino physics community to simulate and study neutrino interactions within different detector concepts using a single program. In addition to neutrino simulations in segmented detectors, this program can also be used for various research projects that use of scintillation detectors for different physics purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of a deep learning semantic segmentation model to helium bubbles and voids in nuclear materials

Imaging nanoscale radiation-induced defects using the transmission electron microscope (TEM) is a key factor in the successful implementation of materials for nuclear energy structural applications. Analyzing each defect in a TEM micrograph is currently a manual task. To identify the defects in a single image can take anywhere from 15 min to an hour and a project can require the analysis of anywhere from tens to ≥ 100 images. Here, we use artificial intelligence (AI) models to automate this task. For simplification, we evaluated images with only a single type of defect; helium bubbles. Additionally, we performed semantic segmentation of these helium bubble defects in electron microscopy images of irradiated FeCrAl alloys using a deep learning DefectSegNet model. This model, which was previously used to classify crystal defects, is inspired by the classic DenseNet and U-Net image segmentation models. It claims high spatial resolution, but has poor performance at object boundaries. Our paper improves the DefectSegNet model’s application by adding two new features. First, the DefectSegNet model is applied not only to perform calculation pixel-wise but also object (or feature) wise. Because object-wise metrics are directly relevant to our final goal of detecting bubbles, whereas pixel-wise classification is only an intermediate step, it is an important part of our study. Second, a distance map loss (DML) function has been added to increase its performance at object boundaries. It is crucial to accurately represent defects boundaries, especially bubbles, in order to track the bubble-induced swelling caused by irradiation. The boundary-focused DML function is also compared to other loss functions like Cross-entropy, Weighted Binary Cross Entropy (WBCE), Dice and Intersection over Union (IOU). Finally, by incorporating new features, we found a marked improvement on segmentation quality and better shape preservation at the boundaries and areas of the bubbles.

42 ENGINEERING↗

A machine learning pipeline for membrane segmentation of cryo-electron tomograms

We describe how to use several machine learning techniques organized in a learning pipeline to segment and identify cell membrane structures from cryo electron tomograms. These tomograms are difficult to analyze with traditional segmentation tools. The learning pipeline in our approach starts from supervised learning via a special convolutional neural network trained with simulated data. It continues with semi-supervised reinforcement learning and/or a region merging technique that tries to piece together disconnected components belonging to the same membrane structure. A parametric or non-parametric fitting procedure is then used to enhance the segmentation results and quantify uncertainties in the fitting. Domain knowledge is used in generating the training data for the neural network and in guiding the fitting procedure through the use of appropriately chosen priors and constraints. We demonstrate that the approach proposed here works well for extracting membrane surfaces in two real tomogram datasets.

97 MATHEMATICS AND COMPUTING↗

Decoupling of ion conductivity from segmental dynamics in oligomeric ethylene oxide functionalized oxanorbornene dicarboximide homopolymers

Here, in order to design more effective solid polymer electrolytes, it is important to decouple ion conductivityfrom polymer segmental motion. To that end, novel polymers based on oxanorbornene dicarboximidemonomers with varying lengths of oligomeric ethylene oxide side chains have been synthesized usingring opening metathesis polymerization. These unique polymers have a fairly rigid and bulky backboneand were used to investigate the decoupling of ion motion from polymer segmental dynamics. Ionconductivity was measured using broadband dielectric spectroscopy for varying levels of added lithiumsalt. The conductivity data demonstrate six to seven orders of separation in timescale of ion conductivityfrom polymer segmental motion for polymers with shorter ethylene oxide side chains. However,commensurate changes in the glass transition temperatures T g reduce the effect of decoupling in ionconductivity and lead to lower conductivity at ambient conditions. These results suggest that both anincrease in decoupling and a reduction in T g might be required to develop solid polymer electrolytes withhigh ion conductivity at room temperature.

36 MATERIALS SCIENCE↗

Segmentation and Comparative Modeling in an 8.6-Å Cryo-EM Map of the Singapore Grouper Iridovirus

SGIV, or Singapore grouper iridovirus, is a large double-stranded DNA virus, reaching a diameter of 220 nm and packaging a genome of 140 kb. We present a 3D cryoelectron microscopy (cryo-EM) icosahedral reconstruction of SGIV determined at 8.6-Å resolution. It reveals several layers including a T = 247 icosahedral outer coat, anchor proteins, a lipid bilayer, and the encapsidated DNA. A new segmentation tool, iSeg, was applied to extract these layers from the reconstructed map. The outer coat was further segmented into major and minor capsid proteins. None of the proteins extracted by segmentation have known atomic structures. Here, we generated models for the major coat protein using three comparative modeling tools, and evaluated each model using the cryo-EM map. Our analysis reveals a new architecture in the Iridoviridae family of viruses. It shares similarities with others in the same family, e.g., Chilo iridescent virus, but also shows new features of the major and minor capsid proteins.

59 BASIC BIOLOGICAL SCIENCES↗

Origin of rate limitations in solid-state polymer batteries from constrained segmental dynamics within the cathode

Currently, one of the key challenges preventing the wide commercialization of polymer-based solid-state batteries is achieving high-rate capabilities. This work unravels chain structure and segmental dynamics in a polymer-based composite cathode consisting of LiFePO 4 (LFP), carbon, and poly(ethylene oxide) (PEO) with lithium bis(trifluoromethanesulfonyl)imide. Small-angle neutron scattering (SANS) data reveal that PEO chains are adsorbed on the surface of LFP particles during slurry processing to make the composite electrode. The strong interaction between LFP and PEO chains leads to greatly reduced segmental dynamics of PEO, as discovered by quasi-elastic neutron scattering (QENS). The reduced segmental dynamics results in 70% decreased Li + mobility of the polymer electrolyte in the composite cathode. The combined SANS and QENS study indicates that one of the key bottlenecks that limits the rate performance of PEO-based polymer batteries originates from molecular interactions within the cathode.

25 ENERGY STORAGE↗

Improved Single-Ion Conductivity of Polymer Electrolyte via Accelerated Segmental Dynamics

Single-ion conducting polymer electrolytes (SICPEs) have many advantages for solid-state battery applications, while low conductivities remain the bottleneck for their practical applications. In this paper, a strategy that can significantly improve the ionic conductivity of SICPEs based on the concept of accelerated segmental dynamics was demonstrated by the evaluation of the thermal property, rheological behavior, morphology analysis, molecular dynamics simulation, and conductivity performance. With both “soft” poly(dimethylsiloxane) (PDMS) backbone and poly(ethylene glycol) (PEG) side chains, the obtained SICPE possesses faster segmental relaxation and higher lithium-ion conductivity. With lithium “transference” number close to unity, the obtained SICPE also shows excellent electrochemical stability against lithium metal electrodes. The clear relationship established between the segmental dynamics of polymer electrolyte and its ionic conductivity should contribute to achieve a solid electrolyte with improved ionic conductivity toward the next-generation solid-state battery.

Segmental Dynamics↗

End-to-End Automated Segmentation Framework for Four-Dimensional Scanning Transmission Electron Microscopy Data

Four-dimensional scanning transmission electron microscopy (4D-STEM) is powerful for rapidly characterizing arrays of nanoparticles produced via high-throughput synthesis. However, such 4D-STEM datasets typically contain thousands of nanoparticles, each characterized by thousands of diffraction patterns spatially distributed across the nanoparticle, necessitating efficient and comprehensive analysis. We propose an end-to-end segmentation framework to automatically segment each nanoparticle into regions with distinct composition/orientation of crystal grains, using only the 4D-STEM data. Bragg disk information is extracted in a physics-informed manner from the diffraction patterns at each spatial location and combined with the real space coordinates to form feature vectors. These feature vectors are then used as inputs to a Gaussian mixture model (GMM) to segment the nanoparticle into distinct regions. We also develop two visualization tools based on the GMM outputs to infer the interface transition and the degree of superposition. Our framework comprehensively integrates machine learning tools and physics knowledge, and provides a basis for substantially compressing enormous 4D-STEM datasets, e.g., by replacing the full 4D-STEM dataset for each nanoparticle with only a single set of Bragg disk features for each distinct crystal grain identified in the nanoparticle. In this article, we demonstrate the power of our framework by presenting results for real, complex datasets.

47 OTHER INSTRUMENTATION↗