Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample Preparation Laboratory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Lawrence Livermore National Laboratory Environmental Report 2021

The purposes of the Lawrence Livermore National Laboratory Environmental Report 2021 are to record Lawrence Livermore National Laboratory’s (LLNL’s) compliance with environmental standards and requirements, describe LLNL’s environmental protection and remediation programs, and present the results of environmental monitoring at the two LLNL sites—the Livermore Site and Site 300. The report is prepared for the U.S. Department of Energy (DOE) by LLNL’s Environmental Functional Area. Submittal of the report satisfies requirements under DOE Order 231.1B, “Environment, Safety and Health Reporting,” and DOE Order 458.1, “Radiation Protection of the Public and Environment.” The report is distributed electronically and is available at https://saer.llnl.gov/, the website for the LLNL annual environmental report. Previous LLNL annual environmental reports beginning with 1994 are also on the website. Some references in the electronic report text are underlined, which indicates that they are clickable links. Clicking on one of these links will open the related document, data workbook, or website. Sampling location maps throughout this report were created using ArcGIS® software by Esri. The report begins with an executive summary, which provides the purpose of the report and an overview of LLNL’s compliance and monitoring results. The first three chapters provide background information: Chapter 1 is an overview of the location, meteorology, and hydrogeology of the two LLNL sites; Chapter 2 is a summary of LLNL’s compliance with environmental regulations; and Chapter 3 is a description of LLNL’s environmental programs with an emphasis on the Environmental Management System including pollution prevention. The majority of the report covers LLNL’s environmental monitoring programs and monitoring data for 2021: effluent and ambient air monitoring and dose assessment (Chapter 4); waters, including wastewater, storm water runoff, surface water, rain, and groundwater (Chapter 5); and terrestrial, including soil, sediment, vegetation, foodstuff, ambient radiation, and special status wildlife and plants (Chapter 6). The remaining two chapters discuss LLNL’s groundwater remediation program (Chapter 7), and quality assurance for the environmental monitoring programs (Chapter 8). Complete monitoring data, which are summarized in the body of the report, are provided in Appendix A. The report uses Système International units, consistent with the federal Metric Conversion Act of 1975 and Executive Order 12770, “Metric Usage in Federal Government Programs” (1991). For ease of comparison to environmental reports issued prior to 1991, dose values and many radiological measurements are given in both metric and U.S. customary units. A conversion table is provided in the glossary. The report is the responsibility of LLNL’s Environmental Functional Area. Monitoring data were obtained through the combined efforts of the Environmental Functional Area; Environmental Restoration Department; Physical and Life Sciences Environmental Monitoring Radiological Laboratory; and the Radiation Protection Functional Area.

54 ENVIRONMENTAL SCIENCES↗

On-Orbit Quantitative Real-Time Gene Expression Analysis Using the Wetlab-2 System

NASA Ames Research Center's WetLab-2 Project enables on-orbit quantitative Reverse Transcriptase PCR (qRT-PCR) analysis without the need for sample return. The WetLab-2 system is capable of processing sample types ranging from microbial cultures to animal tissues dissected on-orbit. The project developed a RNA preparation module that can lyse cells and extract RNA of sufficient quality and quantity for use as templates in qRT-PCR reactions. Our protocol has the advantage of using non-toxic chemicals and does not require alcohols or other organics. The resulting RNA is dispensed into reaction tubes that contain all lyophilized reagents needed to perform qRT-PCR reactions. System operations require simple and limited crew actions including syringe pushes, valve turns and pipette dispenses. The project selected the Cepheid SmartCycler (TradeMark), a Commercial-Off-The-Shelf (COTS) qRT-PCR unit, because of its advantages including rugged modular design, low power consumption, rapid thermal ramp times and four-color multiplex detection. Single tube multiplex assays can be used to normalize for RNA concentration and integrity, and to study multiple genes of interest in each module. The WetLab-2 system can downlink data from the ISS to the ground after a completed run and uplink new thermal cycling programs. The ability to conduct qRT-PCR and generate results on-orbit is an important step towards utilizing the ISS as a National Laboratory facility. Specifically, the ability to get on-orbit data will provide investigators with the opportunity to adjust experimental parameters in real time without the need for sample return and re-flight. On orbit gene expression analysis can also eliminate the confounding effects on gene expression of reentry stresses and shock acting on live cells and organisms or the concern of RNA degradation of fixed samples and provide on-orbit gene expression benchmarking prior to sample return. Finally, the system can also be used for analysis of air, surface, water, and clinical samples to monitor environmental pathogens and crew health. The validation flight of the WetLab-2 system using E. coli bacteria and mouse liver launched on SpaceX-7 in June 2015 and will remain on the ISS National Laboratory.

ISS tools↗

Total metals & anion concentration data; Slate River floodplain, Crested Butte, CO; May 2020-September 2020

This data package includes processed and undiluted measurements for metal and anion concentrations from pore water (groundwater) samples from the Slate River floodplain of Crested Butte, CO, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between May and September of 2020. These measurements were all recorded at the Arizona Laboratory for Emerging Contaminants (ALEC) at the University of Arizona located in Tucson, AZ. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 4C until measured at ALEC.Analysis by ICP-MS:Measurements for total metals were made on the Agilent 7700x ICP-MS (for total metals) – Agilent Technologies, Santa Clara, CA.The analytical QA/QC protocol was adapted from US EPA Method 200.8 for analysis by ICP-MS. Calibration standards were prepared from multi-element stock solution (Sigma-Aldrich Multielement standard solution for ICP, St. Louis, MO) using matrix matched to sample solutions (either 2% HCl or HNO3 from AriStar Plus,grade acids from VWR Scientific). Calibration curves include at least 7 points with correlation coefficients > 0.995. The QC protocol includes a continuing calibration blank (CCB), a continuing calibration verification (CCV) solution and at least one quality control sample (QCS) to be analyzed just after calibration and again after every 12 samples and at the completion of the run. The QCS solutions are from an independent source, such as NIST SRM 1643e - Trace Elements in Water, or QCS solutions from High Purity Standards (Charleston, SC). Acceptable QC responses must be between 90 and 110% of the certified value. An internal standard (Rh) is added via on-line addition into the sample line using a mixing tee.Analysis by Ion Chromatography (Anions):The protocol follows Method 4110 in Standard Methods for Examination of Water and Wastewater.The instrument used is the Thermo Scientific Dionex ICS-6000 using AS+AG22 column set for anion analysis with isocratic method using sodium carbonate eluent. Detection is by chemical suppression of eluent conductivity. Quality control solutions and mixed analyte standards purchased from Inorganic Ventures, Christiansburg, VA.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

Density Measurement of NaCl-MgCl 2 -PuCl 3 and NaCl-UCl 3 -PuCl 3 Molten Salt Systems by Neutron Radiographic Dilatometry

A novel neutron radiographic technique was developed and implemented to measure the change in volume as a function of temperature of select plutonium-containing liquid chloride mixtures from melt to 1250 K. These measurements were performed at Los Alamos National Laboratory by members of the molten salt research group under support from Gateway for Accelerated Innovation in Nuclear (GAIN) voucher NE-21-25117: “Density Measurements of Plutonium Bearing Salts via Neutron Beam Dilatometry”. This technical report contains a description of the experimental method and a summary of the results. Initial characterization of the {NaCl, MgCl 2 , UCl 3 , PuCl 3 } salts used in this experiment includes a combination of x-ray diffraction, differential scanning calorimetry, gamma ray spectroscopy, and inductively coupled plasma mass spectrometry. Four samples of NaCl + MgCl 2 + x mol% PuCl 3 and four samples of NaCl + UCl 3 + x mol% PuCl 3 were prepared at the Plutonium Facility, shipped to the Los Alamos Neutron Science Center (LANSCE), and radiographed with the density via neutron radiography (DvNR) apparatus. Density data in the form of meniscus heights were recorded as a function of temperature. The results show a linear dependence of density with temperature and a third order polynomial dependence of density with composition as a function of PuCl 3 addition in the corresponding halide salt mixture. Additions of PuCl 3 result in a significant increase in density of the salt mixture and a slight reduction in the coefficient of volumetric expansion. These results represent a first measurement of the density of plutonium chloride salt mixtures and, in combination with additional measurements, may lead to a generalized description of the density of such salt systems for arbitrary compositions and temperature.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Building 438 Drainage Channel Soil Sampling and Analysis Plan (February 2023)

This Soil Sampling and Analysis Plan (SAP) was prepared by the Environmental Function Area (EFA)/Technical Services Department (TSD) of the Environment, Safety & Health (ES&H) Directorate for the Project Management Office (PMO) for the proposed Building 438 Drainage Channel Project (project) located near Building 438 (B438) in the southern portion, Building 433 (B433) in the middle portion, and Building 543 (B543) in the northern portion (project area as shown on Figure 1). The purpose of the SAP was to describe the procedures for collection and analysis of environmental samples and evaluation of analytical data (chemical and radiological) to determine management options of excavated soil during project construction in accordance with Lawrence Livermore National Laboratory’s (LLNL) Soils Screening and Management Plan (SSMP) (LLNL 2022), which is consistent with U.S. Environmental Protection Agency (EPA) guidance for developing Data Quality Objectives for environmental data (EPA 2006). The SAP was developed in accordance with the SSMP and based on preliminary design information provided to EFA by PMO.

54 ENVIRONMENTAL SCIENCES↗

Core-scale numerical simulation and comparison of breakdown of shale and resulting fractures using sc-CO 2 and water as injectants

Supercritical carbon dioxide (sc-CO 2 ) is an alternative to water for stimulation of low permeability systems such as shale gas and geothermal resources. Previously core-scale experimental studies have compared the behavior of CO 2 to water injection for sample breakdown. Due to differences in experimental setup and core sample preparation, inconsistent or even apparently contradictory conclusions have resulted. To reconcile this contradiction, a phase-field numerical model is applied to understand hydraulic fracturing experiments using Green River shale found in the literature. The finite element numerical model incorporates a rate-dependent phase-field fracture model developed separately to describe fracture initiation and growth. We investigate the impact of various material and fluid properties on the resulting fractures. Most importantly, we study the effect of fluid properties and boundary conditions on the breakdown pressure, including the direction of the resulting fracture plane. Model results predict that (1) sc-CO 2 injection in the laboratory may result in greater breakdown pressure than that of water under no-flow boundary conditions because lower viscosity sc-CO 2 may result in pressure build up at the core boundary that opposes fracture initiation and (2) lower viscosity sc-CO 2 also produces fast-propagating fractures that are less influenced by the bedding plane on their resulting fracture topology. Here our model offers a straightforward explanation and reconciliation of existing experimental observations, as well as a means to extrapolate to new conditions. Exploration of field-scale conditions suggests less pronounced or no elevation in breakdown pressure when sc-CO 2 is injected because the pressure build up effect at the system boundary is significantly less or absent at field length scales.

42 ENGINEERING↗

Total metals, carbon, nitrogen & anion concentration data; Slate River & East River floodplains, Crested Butte, CO; May 2022-October 2022

This data package includes processed and undiluted measurements for metal, total carbon, total nitrogen, and anion concentrations from pore water (groundwater) and surface water samples from the Slate River and East River floodplains of Crested Butte, CO, focus field sites for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between May and October of 2022. These measurements were all recorded at the Arizona Laboratory for Emerging Contaminants (ALEC) at the University of Arizona located in Tucson, AZ. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 4C until measured at ALEC.Analysis by ICP-MS (metals):Measurements for total metals were made on the Agilent 7700x ICP-MS (for total metals) – Agilent Technologies, Santa Clara, CA. The analytical QA/QC protocol was adapted from US EPA Method 200.8 for analysis by ICP-MS. Calibration standards were prepared from multi-element stock solutions (SPEX Certiprep, Metuchen, NJ). Calibration curves include at least 7 points with correlation coefficients > 0.995. The QC protocol includes a continuing calibration blank (CCB), a continuing calibration verification (CCV) solution and at least one quality control sample (QCS) to be analyzed just after calibration and again after every 12 samples and at the completion of the run. The QCS solutions are from an independent source, such as NIST SRM 1643e - Trace elements in water, or QCS solutions from High Purity Standards (Charleston, SC). Acceptable QC responses must be between 90 and 110% of the certified value. Lastly, a suitable internal standard (usually Rh, In, Ga or Ge) is added using on-line addition into the sample line and mixing tee.Analysis by Shimadzu TOC-L (TOC/TN):The TOC-L system is a combustion technique where liquid samples are injected and combusted into CO2 for carbon detection by non-dispersive infrared (NDIR) and NO for detection by chemiluminescence. A calibration curve using five standard solutions between 0.1 and 7 ppm for carbon and 0.05 and 3.5 ppm for nitrogen is made for each type of measurement with a linearity >0.99. All samples, standards, and QC’s are prepared in 24mL scintillation vials that have been baked for 4hrs at 475 Cº and made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.Analysis by Ion Chromatography (Anions):The instrument used is the Thermo Scientific Dionex ICS-6000 using AS+AG22 column set for anion analysis with sodium carbonate eluent. A calibration curve using five standard solutions between 5 and 250 umol/L is made with a linearity >0.99. Standards and QC’s are prepared in 15mL polypropylene conical tubes, pipetted along with the samples into 1.5mL polypropylene vials. Dilutions are made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

Technology Development and Advanced Planning for Curation of Returned Mars Samples

NASA Johnson Space Center (JSC) curates extraterrestrial samples, providing the international science community with lunar rock and soil returned by the Apollo astronauts, meteorites collected in Antarctica, cosmic dust collected in the stratosphere, and hardware exposed to the space environment. Curation comprises initial characterization of new samples, preparation and allocation of samples for research, and clean, secure long-term storage. The foundations of this effort are the specialized cleanrooms (class 10 to 10,000) for each of the four types of materials, the supporting facilities, and the people, many of whom have been doing detailed work in clean environments for decades. JSC is also preparing to curate the next generation of extraterrestrial samples. These include samples collected from the solar wind, a comet, and an asteroid. Early planning and R\&D are underway to support post-mission sample handling and curation of samples returned from Mars. One of the strong scientific reasons for returning samples from Mars is to search for evidence of current or past life in the samples. Because of the remote possibility that the samples may contain life forms that are hazardous to the terrestrial biosphere, the National Research Council has recommended that all samples returned from Mars be kept under strict biological containment until tests show that they can safely be released to other laboratories. It is possible that Mars samples may contain only scarce or subtle traces of life or prebiotic chemistry that could readily be overwhelmed by terrestrial contamination . Thus, the facilities used to contain, process, and analyze samples from Mars must have a combination of high-level biocontainment and organic / inorganic chemical cleanliness that is unprecedented. JSC has been conducting feasibility studies and developing designs for a sample receiving facility that would offer biocontainment at least the equivalent of current maximum containment BSL-4 (BioSafety Level 4) laboratories, while simultaneously maintaining cleanliness levels equaling those of state-of-the-art cleanrooms. Unique requirements for the processing of Mars samples have inspired a program to develop handling techniques that are much more precise and reliable than the approach (currently used for lunar samples) of employing gloved human hands in nitrogen-filled gloveboxes. Individual samples from Mars are expected to be much smaller than lunar samples, the total mass of samples returned by each mission being 0.5- 1 kg, compared with many tens of kg of lunar samples returned by each of the six Apollo missions. Smaller samples require much more of the processing to be done under microscopic observation. In addition, the requirements for cleanliness and high-level containment would be difficult to satisfy while using traditional gloveboxes. JSC has constructed a laboratory to test concepts and technologies important to future sample curation. The Advanced Curation Laboratory includes a new-generation glovebox equipped with a robotic arm to evaluate the usability of robotic and teleoperated systems to perform curatorial tasks. The laboratory also contains equipment for precision cleaning and the measurement of trace organic contamination.

Lindstrom, David J.↗

Advances in Above- and In-Water Radiometry, Volume 3: Hybridspectral Next-Generation Optical Instruments

This publication documents the scientific advances associated with new instrument systems and accessories built to improve above- and in-water observations of the apparent optical properties (AOPs) for a diversity of water masses, including optically complex waters. The principal objective is to be prepared for the launch of next-generation ocean color satellites with the most capable commercial off-the-shelf (COTS) instrumentation in the shortest time possible. The technologies described herein are entirely new hybrid sampling capabilities, so as to satisfy the requirements established for next-generation missions. Both above- and in-water instruments are documented with software options for autonomous control of data collection activities as applicable. The instruments were developed for the Hybridspectral Alternative for Remote Profiling of Optical Observations for NASA Satellites (HARPOONS) vicarious calibration project. The state-of-the-art accuracy required for vicarious calibration also led to the development of laboratory instruments to ensure the field observations were within uncertainty requirements. Separate detailed presentations of the individual instruments provide the hardware designs, accompanying software for data acquisition and processing, and examples of the results achieved.

Hooker, Stanford B.↗

Characterization of Two Microbial Isolates from Andean Lakes in Bolivia

We are currently investigating the biological population present in the highest and least explored perennial lakes on earth in the Bolivian and Chilean Andes, including several volcanic crater lakes of more than 6000 m elevation, in combination of microbiological and molecular biological methods. Our samples were collected in saline lakes of the Laguna Blanca Laguna Verde area in the Bolivian Altiplano and in the Licancabur volcano crater (27 deg. 47 min S/67 deg. 47 min. W) in the ongoing project studying high altitude lakes. The main goal of the project is to look for analogies with Martian paleolakes. These Bolivian lakes can be described as Andean lakes following the classification of Chong. We have attempted to isolate pure cultures and phylogenetically characterize prokaryotes that grew under laboratory conditions. Sediment samples taken from the Licancabur crater lake (LC), Laguna Verde (LV), and Laguna Blanca (LB) were analyzed and cultured using enriched liquid media under both aerobic and anaerobic conditions. All cultures were incubated at room temperature (15 to 20 C) and under light exposure. For the reported isolates, 36 hours incubation were necessary for reaching optimal optical densities to consider them viable cultures. Ten serial dilutions starting from 1% inoculum were required to obtain a suitable enriched cell culture to transfer into solid media. Cultures on solid medium were necessary to verify the formation of colonies in order to isolate pure cultures. Different solid media were prepared using several combinations of both trace minerals and carbohydrates sources in order to fit their nutrient requirements. The microorganisms formed individual colonies on solid media enriched with tryptone, yeast extract and sodium chloride. Cells morphology was studied by optical and electronic microscopy. Rodshape morphologies were observed in most cases. Total bacterial genomic DNA was isolated from 50 ml late-exponential phase culture by using the CTAB miniprep protocol. The 16S rRNA genes were amplified by PCR using both Bacteria- and Archaeauniversal primer sets: 27f and 1492r, 21f and 1492r respectively. Sequences of 16S rRNA gene were determined and initially compared with reference sequences contained in the EMBL nucleotide sequence database by using the BLAST program and were subsequently aligned with 16S rRNA reference sequences in the ARB package (http://www.mikro.biologie.tu-muenchen.de). Aligned sequences were inserted within a stable phylogenetic tree by using the ARB parsimony tool. In this work we report the morphology and phylogenetic characterization of two isolates belonged to Laguna Blanca sediments.

Demergasso, C.↗

GeoSoilEnviroCARS (Sector 13) at the Advanced Photon Source: a comprehensive synchrotron radiation facility for Earth science research at ambient and extreme conditions

GeoSoilEnviroCARS (GSECARS) is a comprehensive analytical laboratory for Earth and environmental science research using X-ray beams from the Advanced Photon Source, Argonne National Laboratory. State-of-the-art instruments are available for (1) high-pressure/high- or low-temperature diffraction, total scattering, and spectroscopy (Brillouin, Raman, and VIS-IR) using the laser heated diamond anvil cell (DAC); (2) high-pressure/high-temperature diffraction, scattering, and imaging as well as acoustic emission (AE) and ultrasonics using the large-volume press (LVP); (3) powder, single crystal, and surface/interface diffraction; (4) X-ray absorption fine structure spectroscopy; (5) X-ray fluorescence microprobe analysis; and (6) microtomography. As shown here, experiments are facilitated by senior level staff who collaborate on all aspects of the analytical work including experiment design, sample preparation, data collection, data interpretation, and publication preparation. Both technical and scientific synergies occur as a result of the intimate association of the various techniques and scientists experienced in the applications of synchrotron radiation to Earth, environmental, and planetary science problems. The facility includes state-of-the-art instrumentation designed and built in-house, including custom X-ray optics, online and offline laser-based systems, specialized sample environments and positioning systems, as well as pixel-array and multi-crystal energy dispersive X-ray detectors, which are available to be shared among the experimental stations.

36 MATERIALS SCIENCE↗

There's Iron in Them Thar Hills: A Geologic Look at the Aristarchus Plateau as a Potential Landing Site for Human Lunar Return

Lunar pyroclastic deposits are unique among lunar soils. Composed of very fine grained glass beads rich in Fe, Ti and Mg they yield unique spectral signatures. From the spectra two major classes and five subclasses of lunar dark mantling deposits have been identified. Recent work by me and others has shown that the larger regional deposits are more numerous, extensive, thicker, and widely distributed than previously thought, leading us to suggest that they would make ideal resource feedstock for future lunar surface activities. Returned sample studies and the recently collected Galileo and Clementine data also corroborate these findings. Recent planning for return to the Moon indicates that large cost savings can result from using locally produced oxygen, and recent JSC laboratory results indicate that iron-rich pyroclastic dark mantling deposits may be the richest oxygen resource on the Moon. My earlier work demonstrated that instead of using regolith, bulk lunar pyroclastic deposits are better suited for beneficiation as they are thick (lO's m's), unconsolidated, fine-grained deposits. In addition, the lack of rocks and boulders and the typically flat to gently rolling terrain will facilitate their mining and processing. In preparation for the Human Lunar Return (HLR) I have characterized the Aristarchus Plateau (24 deg. N 52 deg. W) as a potential landing site for an in-situ resource utilization (ISRU) demonstration. The geologic diversity and large volume of Fe-rich pyroclastic material present at the Aristarchus site make it an ideal target for extracting O2, H2 and halogens. This paper (1) describes the current understanding of the geology of Aristarchus plateau; (2) describes the resource potential of the Aristarchus plateau; and (3) presents several candidate landing sites on the plateau for future lunar activities.

Coombs, Cassandra R.↗

Rapid Biochemical Analysis on the International Space Station (ISS): Preparing for Human Exploration of the Moon and Mars

The Lab-on-a-Chip Application Development - Portable Test System, known as LOCAD-PTS, was launched to the International Space Station (ISS) aboard Space Shuttle Discovery (STS-116) on December 9th,2006. Since that time, it has remained onboard ISS and has been operated by the crew on 10 separate occasions LOCAD-PTS is a handheld device for rapid biochemical analysis; it consists of a spectrophotometer, a series of interchangeable cartridges, a pipette and several clean/sterilized swabbing kits to obtain samples from ISS surfaces. Sampling, quantitative analysis and data retrieval is performed onboard, therefore reducing the need to return samples to Earth. Less than 20 minutes are required from sampling to data, significantly faster than existing culture-based methods on ISS, which require 3-5 days. Different cartridges are available for the detection of different target molecules (simply by changing the formulation within each cartridge), thereby maximizing the benefit and applications addressed by a single instrument. Initial tests on ISS have focused on the detection of the bact.erial macromolecule endotoxin, a component of bacterial cell walls. LOCAD-PTS detects endotoxin with a cartridge that contains a formulation known as Limulus Amebocyte Lysate (LAL) assay. LAL is derived from blood of the horseshoe crab, Limulus polyphemus, and detects enodotoxin with an enzyme cascade that triggers generation Of a yellow colored dye, p-nitroanaline. The more p-nitroanaline product, the more endotoxin is in the original sample. To enable quantitative analysis, the absorbance of this color is measured by LOCAD-PTS through a 395 nm filter and compared with an internal calibration curve, to provide a reading on the LED display that ranges from 0.05 Endotoxin Units (EU)/ml to 5 EU/ml. Several surface sites were analyzed within ISS between March 2007 and February 2008, including multiple locations in the US Laboratory Destiny, Node 1 Unity, AMock, and Service Module Zvezda. The goals of this initial study were to i) test the cleanliness of reagents/supplies on orbit, ii) test the crew's ability to collect and process a sample in microgravity without contamination, iii) demonstrate nominal function of the LOCAD-PTS, and iv) provide a general survey of endotoxin within the ISS. The surface sites varied greatly in terms of their frequency-of-use and material texture/composition; from relatively smooth aluminum, to fabric, to the room temperature vulcanizing (RTV) rubber of a Extravehicular Mobility Unit (EMU) spacesuit. Results showed that: i) the swabbing kits and reagents remained clean on orbit, ii) the crew could collect and process a sample without contamination, and iii) the LOCAD-PTS functioned nominally in > 99% of the 55 tests completed. We will present detailed results of the survey of endotoxin on ISS surfaces. These results and technology are important in the near-term - by providing an extra tool in the toolbox for ISS microbial monitoring. They are also important in the longer term as valuable preparation for human exploration of the Moon and Mars. One of the proposed science goals for the human exploration of Mars will be to detect and characterize any indigenous biological molecules that may exist on the Martian surface. To achieve that goal, the crew must have the technology available onboard to differentiate indigenous biology from any terrestrial biological material brought to Mars by the spacecraft and crew (termed 'forward contamination'). The LAL assay is already one of the official methods used by NASA's planetary protection program to certify cleanliness of interplanetary robotic spacecraft prior to launch; and therefore endotoxin is a good marker of forward contamination (as well as other microbial molecules detectable with LOCAD-PTS e.g. box-1, 3-glucan and lipoteichoic acid). Furthermore, the distribution and abundance of these molecules on the ISS provides a good indicator of what to expect on the Crew Exploratioehicle Orion, the lunar lander Antares, and future crewed spacecraft destined for Mars. In addition, technology such as LOCAD-PTS has been proposed to help evaluate forward contamination during lunar surface operations by the crew, as preparation for the human exploration of Mars.

Maule, J.↗

Enhanced Spatial Proteomics and Metabolomics from a Single Tissue Section Using MALDI-MSI and LCM-microPOTS Platforms

Spatially resolved mass spectrometry (MS)-based multi-omics workflows are becoming more utilized for revealing the complex biology that occurs within tissues. However, these approaches commonly require multiple independent tissue sections to analyze the metabolite and protein compositions of these samples. This poses a significant challenge in preserving cell- or region-specific molecular fidelity, as variations between tissue sections can compromise the accurate correlation of molecular data. Here, in this study, we developed workflows for comprehensive multi-omics profiling from a single tissue section (STS) using different MS modalities. We enhanced the functionality of an electrically insulated substrate by employing metal-assisted approaches that enabled both MS-based untargeted spatial metabolomics and proteomics from STS. This allowed metabolite imaging using matrix-assisted laser desorption/ionization-MS imaging (MALDI-MSI), without compromising it for subsequent proteome profiling with laser capture microdissection (LCM)-based technology. Specifically, implementing copper tape as a backing for polyethylene naphthalate (PEN) slides enabled the detection of >140 metabolites across a poplar root tissue section using MALDI-trapped ion mobility spectrometry time of flight (timsTOF)-MS. Afterwards, we detected 6,571 unique proteins from two distinct root regions by leveraging LCM technology coupled to our microdroplet based sample preparation approach. We also developed an alternative workflow utilizing gold-coated PEN substrates for imaging with MALDI-Fourier-transform ion cyclotron resonance (FTICR)-MS, which permitted the profiling of >170 metabolites and the identification of 6,542 unique proteins across a single poplar root tissue section. These results were comparable to using each assay independently without modifications. These approaches offer new opportunities for high-resolution molecular profiling of multiple omics-levels across biological tissues.

Veličković, Marija [Pacific Northwest National Lab↗

Measurement of the 73 As ⁢(𝑛,𝛾) cross section at thermal neutron energies

A measurement of the thermal neutron capture cross section of 73 As (t 1/2 = 80.3 d) was performed utilizing the University of Missouri Research Reactor. Two sealed quartz tubes containing 73 As were prepared and characterized before being irradiated for ≈1 week. The resulting production of 74 As was quantified with γ-ray spectroscopy. Monitor foils of Fe, Zr, and Mo were irradiated alongside the 73 As samples to assess the thermal and resonance region neutron fluxes. In conclusion, the thermal 73 As ⁢(𝑛,𝛾) cross section was determined to be 56.1 ± 8.9 b based on the average of the two 73 As samples and represents the first neutron-induced reaction cross section measured on 73 As.

and nuclear chemistry↗

Preparation and characterization of multiphase ceramic designer waste forms

Abstract The long-term performance, or resistance to elemental release, is the defining characteristic of a nuclear waste form. In the case of multiphase ceramic waste forms, correlating the long-term performance of multiphase ceramic waste forms in the environment to accelerated chemical durability testing in the laboratory is non-trivial owing to their complex microstructures. The fabrication method, which in turn affects the microstructure, is further compounding when comparing multiphase ceramic waste forms. In this work, we propose a “designer waste form” prepared via spark plasma sintering to limit interaction between phases and grain growth during consolidation, leading to monolithic high-density waste forms, which can be used as reference materials for comparing the chemical durability of multiphase waste forms. Designer waste forms containing varying amounts of hollandite in the presence of zirconolite and pyrochlore in a fixed ratio were synthesized. The product consistency test (PCT) and vapor hydration test (VHT) were used to assess the leaching behavior. Samples were unaffected by the VHT after 1500 h. As measured by the PCT, the fractional Cs release decreased as the amount of hollandite increased. Elemental release from the zirconolite and pyrochlore phases did not appear to significantly contribute to the elemental release from the hollandite phase in the designer waste forms.

36 MATERIALS SCIENCE↗

Sample glue layer investigation and mitigation for laser induced prompt impulse experiments

Understanding longer timescale material reactions under dynamic stress loading is critical for applications in materials engineering, shock physics, and planetary science. Prompt impulse experiments generate lower pressures since the ablator—the material first removed by the laser—is thicker and farther from the diagnostic plane, capturing aggregate material responses from the initial shock wave, rarefaction waves, and later time effects. This complexity demands thorough material characterization and simulation support. Since traditional sample construction is specific to supported shock experiments, designing prompt impulse experiments requires reconsideration around target design and sample engineering. Here, we present sample preparation techniques, experimental investigations, and theoretical simulations to investigate glue layer impacts, aiming to standardize samples for consistent data at lower laser fluences. We find that glue layers <30 μm have a minimal impact on peak velocity and pulse shape. The peak velocity scales linearly with glue layer thickness until a glue layer of 75 μm. For glue layers >75 μm, the peak velocity no longer scales with thickness; however, the pulse shape continues to degrade as described by simulations.

Lasers↗

Versailles Project on Advanced Materials and Standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene

We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ~3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ~5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ~4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. Finally, we also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.

36 MATERIALS SCIENCE↗