Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Modular automated bottom-up proteomic sample preparation for high-throughput applications

Manual proteomic sample preparation methods limit sample throughput and often lead to poor data quality when thousands of samples must be analyzed. Automated liquid handler systems are increasingly used to overcome these issues for many of the sample preparation steps. Here, we detail a step-by-step protocol to prepare samples for bottom-up proteomic analysis for Gram-negative bacterial and fungal cells. The full modular protocol consists of three optimized protocols to: (A) lyse Gram-negative bacteria and fungal cells; (B) quantify the amount of protein extracted; and (C) normalize the amount of protein and set up tryptic digestion. These protocols have been developed to facilitate rapid, low variance sample preparation of hundreds of samples, be easily implemented on widely-available Beckman-Coulter Biomek automated liquid handlers, and allow flexibility for future protocol development. By using this workflow 50 micrograms of protein from 96 samples can be prepared for tryptic digestion in under an hour. We validate these protocols by analyzing 47 Pseudomonas putida and Rhodosporidium toruloides samples and show that this modular workflow provides robust, reproducible proteomic samples for high-throughput applications. The expected results from these protocols are 94 peptide samples from Gram-negative bacterial and fungal cells prepared for bottom-up quantitative proteomic analysis without the need for desalting column cleanup and with protein relative quantity variance (CV%) below 15%.

59 BASIC BIOLOGICAL SCIENCES↗

Statistical Analysis of Tank 5 Floor Sample Results (U)

Sampling has been completed for the characterization of the residual material on the floor of Tank 5 in the F-Area Tank Farm at the Savannah River Site (SRS), near Aiken, SC. The sampling was performed by Savannah River Remediation (SRR) LLC using a stratified random sampling plan with volume-proportional compositing. The plan consisted of partitioning the residual material on the floor of Tank 5 into three non-overlapping strata: two strata enclosed accumulations, and a third stratum consisted of a thin layer of material outside the regions of the two accumulations. Each of three composite samples was constructed from five primary sample locations of residual material on the floor of Tank 5. Three of the primary samples were obtained from the stratum containing the thin layer of material, and one primary sample was obtained from each of the two strata containing an accumulation. This report documents the statistical analyses of the analytical results for the composite samples. The objective of the analysis is to determine the mean concentrations and upper 95% confidence (UCL95) bounds for the mean concentrations for a set of analytes in the tank residuals. The statistical procedures employed in the analyses were consistent with the Environmental Protection Agency (EPA) technical guidance by Singh and others [2010]. Savannah River National Laboratory (SRNL) measured the sample bulk density, nonvolatile beta, gross alpha, and the radionuclide1, elemental, and chemical concentrations three times for each of the composite samples. The analyte concentration data were partitioned into three separate groups for further analysis: analytes with every measurement above their minimum detectable concentrations (MDCs), analytes with no measurements above their MDCs, and analytes with a mixture of some measurement results above and below their MDCs. The means, standard deviations, and UCL95s were computed for the analytes in the two groups that had at least some measurements above their MDCs. The identification of distributions and the selection of UCL95 procedures generally followed the protocol in Singh, Armbya, and Singh [2010]. When all of an analyte's measurements lie below their MDCs, only a summary of the MDCs can be provided. The measurement results reported by SRNL are listed, and the results of this analysis are reported. The data were generally found to follow a normal distribution, and to be homogenous across composite samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 38H (HTF-38-16-26, 27) and Tank 43H (HTF-43-16-28, 29) Samples for Support of the Enrichment Control and Corrosion Control Programs

Savannah River National Laboratory analyzed samples from Tank 38H and Tank 43H to support Enrichment Control Program and Corrosion Control Program. The total uranium in the Tank 38H samples ranged from 20.5 to 34.0 mg/L while the Tank 43H samples ranged from 47.6 to 50.6 mg/L. The U-235 percentage ranged from 0.62% to 0.64% over the four samples. The total uranium and percent U-235 results appear consistent with previous Tank 38H and Tank 43H uranium measurements. The Tank 38H plutonium results show a large difference between the surface and sub-surface sample concentrations and a somewhat higher concentration than previous sub-surface samples. The two Tank 43H samples show similar plutonium concentrations and are within the range of values measured on previous samples. The plutonium results may be biased high due to the presence of plutonium contamination in the blank samples from the cell sample preparations. The four samples analyzed show silicon concentrations ranging from 47.9 to 105 mg/L.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pacific Northwest National Laboratory Facility Radionuclide Emission Points and Sampling Systems

Battelle–Pacific Northwest Division operates numerous research and development laboratories in Washington State. The U.S. Department of Energy (DOE) contracts to Battelle at Richland facilities on both the DOE Hanford Site and the Pacific Northwest National Laboratory (PNNL) Richland campus. These facilities have the potential for radionuclide air emissions. The PNNL contract with DOE also includes operations at the PNNL-Sequim campus in Sequim, where there is also the potential for radionuclide air emissions. This document is a periodic update that describes current PNNL facility emission units and sampling systems. The National Emission Standard for Hazardous Air Pollutants (NESHAP [40 Code of Federal Regulations 61, Subpart H]) requires an assessment of all emission units that have the potential for radionuclide air emissions. Emission units are registered with the State of Washington. Potential emissions from emission units are assessed annually by PNNL staff. Sampling, monitoring, and other regulatory compliance requirements are designated based on the potential to-emit dose criteria, a graded approach to facility-identified potential impact categories, and regulatory requirements. The purpose of this document is to describe the facility radionuclide air emission sampling program and provide current and historical facility emission unit system performance, operation, and design information. For sampled emission units, the building, exhaust unit, control technologies, and sample extraction details are provided. Additionally, applicable configuration drawings, figures, and photographs are included. For non-sampled emission units, emission estimation and radionuclide source details are provided. Site-wide permits for the lowest potential impact category are described. Deregistered/transitioned emission unit details are also provided as necessary for at least 5 years post-closure/transition. Currently, five emission units are sampled continuously for particulate radionuclides at PNNL managed facilities on the PNNL-Richland campus (3 of the 5) and on the Hanford Site (2 of the 5). Four of these units have sampling systems that comply with the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1–2011 standard for sampling from stacks and ducts of nuclear facilities, and the fifth is grandfathered and compliant with the older ANSI N13.1–1969 standard. In addition, the PNNL-managed Hanford Site 325 Building EP 325-01-S stack is sampled continuously for emissions of tritium. No emissions sampling is required for the single licensed emission unit on the PNNL-Sequim campus.

54 ENVIRONMENTAL SCIENCES↗

Microfluidic-Based Sample Chips for Radioactive Solutions

Historical nuclear fuel cycle process sampling techniques required sample volumes ranging in the tens of milliliters. The radiation levels experienced by analytical personnel and equipment, in addition to the waste volumes generated from analysis of these samples, have been significant. These sample volumes also impacted accountability inventories of required analytes during process operations. To mitigate radiation dose and other issues associated with the historically larger sample volumes, a microcapillary sample chip was chosen for further investigation. The ability to obtain microliter volume samples coupled with a remote automated means of sample loading, tracking, and transporting to the analytical instrument would greatly improve analytical efficiency while reducing both personnel exposure and radioactive waste volumes. Sample chip testing was completed to determine the accuracy, repeatability, and issues associated with the use of microfluidic sample chips used to supply µL sample volumes of lanthanide analytes dissolved in nitric acid for introduction to an analytical instrument for elemental analysis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Molten Salt Sampling Techniques and Analytical Approaches

Recent global interest in pyroprocessing and molten salt reactors has brought salt sampling methods and techniques back to the forefront of nuclear safeguards concerns. Issues with uranium supplies have also encouraged various countries to pursue advanced nuclear fuel cycles. Tracking nuclear material in molten salt has proven to be a challenge and updating molten salt sampling will greatly help in this endeavor. Molten salt is problematic to sample due to salt stratification, lack of homogeneity, solids, and difficulty with hot cell adaptations. Various salt sampling techniques have been used since before the 1960s including surface, spoon/spatula, and bar solidification. Since then, new types of sampling techniques have been developed to improve sampling results. These include rod/dip, pipet, suction, filtered sampling along with devices such as the Valve Core Sampler and the Multi-Level Sampler. These different approaches are being analyzed and improved upon along with developing requirements for an improved salt sampling device. Work continues to develop salt samplers that are more robust, easier to segment, collect at a specific depth, can work with filters, and can collect fines. Sampling parameters are also being narrowed in terms of stirring, settling time, filtration, depth, etc. In the future, we hope to address deficiencies for process control and nuclear material accountancy control by determining the best way to collect samples that minimizes contaminants and is representative. A compilation of salt sampling approaches, analyses techniques, and an evaluation of findings will be presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An enhanced droplet-based liquid microjunction surface sampling system coupled with HPLC-ESI-MS/MS for spatially resolved analysis

Droplet-based liquid microjunction surface sampling coupled with high-performance liquid chromatography (HPLC)-electrospray ionization (ESI)-tandem mass spectrometry (MS/MS) for spatially resolved analysis provides the possibility of effective analysis of complex matrix samples and can provide a greater degree of chemical information from a single spot sample than is typically possible with a direct analysis of an extract. Described here is the setup and enhanced capabilities of a discrete droplet liquid microjunction surface sampling system employing a commercially available CTC PAL autosampler. The system enhancements include incorporation of a laser distance sensor enabling unattended analysis of samples and sample locations of dramatically disparate height as well as reliably dispensing just 0.5 μL of extraction solvent to make the liquid junction to the surface, wherein the extraction spot size was confined to an area about 0.7 mm in diameter; software modifications improving the spatial resolution of sampling spot selection from 1.0 to 0.1 mm; use of an open bed tray system to accommodate samples as large as whole-body rat thin tissue sections; and custom sample/solvent holders that shorten sampling time to approximately 1 min per sample. Lastly, the merit of these new features was demonstrated by spatially resolved sampling, HPLC separation, and mass spectral detection of pharmaceuticals and metabolites from whole-body rat thin tissue sections and razor blade (“crude”) cut mouse tissue.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High energy X-ray characterization of the microstructure of PuGa alloy samples at macroscopic depths and non-ambient conditions

High energy (95 keV) X-rays were utilized to characterize the microstructure of eight PuGa alloy samples at room temperature and during cooling to ∼10 K. The samples had different Ga content (nominally 0-3.4 at.%), age, and history. A ninth sample, similarly characterized with neutron diffraction, was included to extend the Ga range to 7 at.%. The samples span the range from single phase α (monoclinic) to δ (face-centered cubic) PuGa, as well as a two-phase α′/δ sample. The crystallographic textures, phase fractions, lattice parameters and dislocation densities of each sample were evaluated through distinct analysis techniques. The textures of the samples were modest. In each case, the dislocation densities were relatively high, comparable to cold worked metals and metals exposed to similar radiation dose. At room temperature, the lattice parameters determined in the predominantly single-phase samples were larger than expected based on the nominal Ga concentration. The observed lattice thermal expansions of the single-phase δ samples to 10 K are self-consistent across the samples and consistent with previous measurements reported in the literature. Significantly larger thermal lattice strain is observed in the δ phase of the two-phase material due to mechanical constraint from the α′ phase, which has a three times larger thermal expansion and is much harder than the δ phase. In conclusion, the results demonstrate the unique value of high-energy X-rays for relatively routine microstructural characterization of Pu alloy samples.

36 MATERIALS SCIENCE↗

Faulting processes in active faults - Evidences from TCDP and SAFOD drill core samples

The microstructures, mineralogy and chemistry of representative samples collected from the cores of the San Andreas Fault drill hole (SAFOD) and the Taiwan Chelungpu-Fault Drilling project (TCDP) have been studied using optical microscopy, TEM, SEM, XRD and XRF analyses. SAFOD samples provide a transect across undeformed host rock, the fault damage zone and currently active deforming zones of the San Andreas Fault. TCDP samples are retrieved from the principal slip zone (PSZ) and from the surrounding damage zone of the Chelungpu Fault. Substantial differences exist in the clay mineralogy of SAFOD and TCDP fault gouge samples. Amorphous material has been observed in SAFOD as well as TCDP samples. In line with previous publications, we propose that melt, observed in TCDP black gouge samples, was produced by seismic slip (melt origin) whereas amorphous material in SAFOD samples was formed by comminution of grains (crush origin) rather than by melting. Dauphiné twins in quartz grains of SAFOD and TCDP samples may indicate high seismic stress. The differences in the crystallographic preferred orientation of calcite between SAFOD and TCDP samples are significant. Microstructures resulting from dissolution–precipitation processes were observed in both faults but are more frequently found in SAFOD samples than in TCDP fault rocks. As already described for many other fault zones clay-gouge fabrics are quite weak in SAFOD and TCDP samples. Clay-clast aggregates (CCAs), proposed to indicate frictional heating and thermal pressurization, occur in material taken from the PSZ of the Chelungpu Fault, as well as within and outside of the SAFOD deforming zones, indicating that these microstructures were formed over a wide range of slip rates.

Janssen, C.↗

A numerical and experimental approach to compare the effect of sample thickness in small in-situ SEM and large ex-situ tensile testing in Alloy 709

ASTM standards for tensile tests define specific sample size requirements regardless of grain size of the material. However, sample size requirements for testing should be considered in conjunction with the number of grains within its reduced cross-sectional area. This is particularly important for in-situ Scanning Electron Microscope (SEM) tensile tests, as they have to be conducted on smaller samples. In this study, a comprehensive experimental and numerical evaluation of the effect of specimen thickness (and the resulting number of grains within the cross-section) were conducted using in-situ SEM tensile test (on submillimeter thick samples) and ex-situ tensile tests (on samples of 0.68–5.9 mm thickness) and the results are compared with FEM simulations outcome. All tests were conducted at room temperature and the results are correlated to the number of grains within the thickness of specimens. The tensile test results indicated that even though the 0.2% proof stress and the tensile strength do not vary for the current range of thicknesses (with number of grains in the cross-section varying from 13 to 118), a difference in necking mechanism exists. Post tensile strength, thinner samples undergo more shear failure and diagonal localized necking whereas thicker samples experience more diffuse necking indicated by decreased area of shear failure at the edges and increased area of dimpled tensile failure at the center of the sample. Further, FEM results complement the experimental findings by showing the formation of conjugated localized shear bands on the upper and lower surface in the 0.68 mm thick sample and shear bands combining to form singular shear bands in thicker samples. These results also confirm the validity of the in-situ SEM tensile tests conducted on thinner samples as long as the required minimum number of grains exist within the cross-section.

36 MATERIALS SCIENCE↗

Combined Falling Drop/Open Port Sampling Interface System for Automated Flow Injection Mass Spectrometry

The aim of this work was to demonstrate and to evaluate the analytical performance of a combined falling drop/open port sampling interface (OPSI) system as a simple noncontact, no-carryover, automated system for flow injection analysis with mass spectrometry. The falling sample drops were introduced into the OPSI using a widely available autosampler platform utilizing low cost disposable pipet tips and conventional disposable microtiter well plates. The volume of the drops that fell onto the OPSI was in the 7–15 μL range with an injected sample volume of several hundred nanoliters. Sample drop height, positioning of the internal capillary on the sampling end of the probe, and carrier solvent flow rate were optimized for maximum signal. Sample throughput, signal reproducibility, matrix effects, and quantitative analysis capability of the system were established using the drug molecule propranolol and its isotope labeled internal standard in water, unprocessed river water and two commercially available buffer matrices. A sample-to-sample throughput of ~45 s with a ~4.5 s base-to-base flow injection peak profile was obtained in these experiments. In addition, quantitation with minimally processed rat plasma samples was demonstrated with three different statin drugs (atorvastatin, rosuvastatin, and fluvastatin). Direct characterization capability of unprocessed samples was demonstrated by the analysis of neat vegetable oils. Employing the autosampler system for spatially resolved liquid extraction surface sampling exemplified by the analysis of propranolol and its hydroxypropranolol glucuronide phase II metabolites from a rat thin tissue section was also illustrated.

47 OTHER INSTRUMENTATION↗

Efficient Sampling of Complex Interdependent and Multiplex Networks

Efficient sampling of interdependent and multiplex infrastructure networks is critical for effectively applying failure and recovery algorithms in real-world settings, as well as to generate property-preserving reduced-order graph-based ensembles that address topological uncertainties. In this paper, we first explore the performance, i.e. the success in preserving graph properties, of graph sampling algorithms for interdependent and multiplex networks with synthetic and real-world graphs. We simulate sampling algorithms under different parameter settings. These settings include probabilistic graph generators, coupling patterns, and various performance metrics. Our results show that while Random Node and Random Walk sampling algorithms perform best for interdependent networks, Random Edge and Forest Fire sampling algorithms perform best for multiplex networks. Second, we propose and implement a novel similarity-based sampling algorithm for multiplex networks that samples only log(N) number of layers of an N-layer multiplex network while yielding computational savings with performance guarantees. Experimental results show that similarity sampling outperforms complete sampling of all layers while decreasing performance costs from a linear scale to a logarithmic one. Our results also indicate that similarity-based sampling outperforms complete sampling and random selection in nearly all scenarios when tested with real-world data.

Subasi, Omer↗

Producing a BOSS CMASS sample with DES imaging

We present a sample of galaxies with the Dark Energy Survey (DES) photometry that replicates the properties of the BOSS CMASS sample. The CMASS galaxy sample has been well characterized by the Sloan Digital Sky Survey (SDSS) collaboration and was used to obtain the most powerful redshift-space galaxy clustering measurements to date. A joint analysis of redshift-space distortions (such as those probed by CMASS from SDSS) and a galaxy-galaxy lensing measurement for an equivalent sample from DES can provide powerful cosmological constraints. Unfortunately, the DES and SDSS-BOSS footprints have only minimal overlap, primarily on the celestial equator near the SDSS Stripe 82 region. Using this overlap, we build a robust Bayesian model to select CMASS-like galaxies in the remainder of the DES footprint. The newly defined DES-CMASS (DMASS) sample consists of 117,293 effective galaxies covering $1,244 {\rm deg}^2$. Through various validation tests, we show that the DMASS sample selected by this model matches well with the BOSS CMASS sample, specifically in the South Galactic cap (SGC) region that includes Stripe 82. Combining measurements of the angular correlation function and the clustering-z distribution of DMASS, we constrain the difference in mean galaxy bias and mean redshift between the BOSS CMASS and DMASS samples to be $\Delta b = 0.010^{+0.045}_{-0.052}$ and $\Delta z = \left( 3.46^{+5.48}_{-5.55} \right) \times 10^{-3}$ for the SGC portion of CMASS, and $\Delta b = 0.044^{+0.044}_{-0.043} $ and $\Delta z= ( 3.51^{+4.93}_{-5.91}) \times 10^{-3}$ for the full CMASS sample. These values indicate that the mean bias of galaxies and mean redshift in the DMASS sample is consistent with both CMASS samples within $1\sigma$.

79 ASTRONOMY AND ASTROPHYSICS↗

Tuning the spin dynamics and magnetic phase transitions of the Cantor alloy via composition and sample processing protocols: A muon spin relaxation study

CrMnFeCoNi, also called the Cantor alloy, is a well-known high-entropy alloy whose magnetic properties have recently become a focus of attention. Here, we present a detailed muon spin relaxation study of the influence of chemical composition and sample processing protocols on the magnetic phase transitions and spin dynamics of several different Cantor alloy samples. Specific samples studied include a pristine equiatomic sample, samples with deficient and excess Mn content, and equiatomic samples magnetized in a field of 9 T or plastically deformed in pressures up to 0.5 GPa. The results confirm the sensitive dependence of the transition temperature on composition and demonstrate that post-synthesis pressure treatments cause the transition to become significantly less homogeneous throughout the sample volume. In addition, we observe critical spin dynamics in the vicinity of the transition in all samples, reminiscent of canonical spin glasses and magnetic materials with ideal continuous phase transitions. Application of an external magnetic field suppresses the critical dynamics in the Mn-deficient sample, while the equiatomic and Mn-rich samples show more robust critical dynamics. The spin-flip thermal activation energy in the paramagnetic phase increases with Mn content, ranging from 3.1⁢(3) × 10 -21 J for 0% Mn to 1.2⁢(2) × 10 -20 J for 30% Mn content. These results shed light on critical magnetic behavior in environments of extreme chemical disorder and demonstrate the tunability of spin dynamics in the Cantor alloy via chemical composition and sample processing.

36 MATERIALS SCIENCE↗

Composite Sampling of a Bacillus anthracis Surrogate with Cellulose Sponge Surface Samplers from a Nonporous Surface

A series of experiments was conducted to explore the utility of composite-based collection of surface samples for the detection of a Bacillus anthracis surrogate using cellulose sponge samplers on a nonporous stainless steel surface. Two composite-based collection approaches were evaluated over a surface area of 3716 cm 2 (four separate 929 cm 2 areas), larger than the 645 cm 2 prescribed by the standard Centers for Disease Control (CDC) and Prevention cellulose sponge sampling protocol for use on nonporous surfaces. The CDC method was also compared to a modified protocol where only one surface of the sponge sampler was used for each of the four areas composited. Differences in collection efficiency compared to positive controls and the potential for contaminant transfer for each protocol were assessed. The impact of the loss of wetting buffer from the sponge sampler onto additional surface areas sampled was evaluated. Statistical tests of the results using ANOVA indicate that the collection of composite samples using the modified sampling protocol is comparable to the collection of composite samples using the standard CDC protocol (p = 0.261). Most of the surface-bound spores are collected on the first sampling pass, suggesting that multiple passes with the sponge sampler over the same surface may be unnecessary. The effect of moisture loss from the sponge sampler on collection efficiency was not significant (p = 0.720) for both methods. Contaminant transfer occurs with both sampling protocols, but the magnitude of transfer is significantly greater when using the standard protocol than when the modified protocol is used (p<0.001). The results of this study suggest that composite surface sampling, by either method presented here, could successfully be used to increase the surface area sampled per sponge sampler, resulting in reduced sampling times in the field and decreased laboratory processing cost and turn-around times.

59 BASIC BIOLOGICAL SCIENCES↗

Variation in Uranium Isotopic Ratios 238 U/ 235 U and 234 U/ 238 U and 236 U/ 238 U in Water Samples Collected from Private Wells in the Española Basin, Santa Fe, New Mexico

This report presents uranium concentration and variation in uranium isotopic ratios 238 U/ 235 U and 234 U/ 238 U and 236 U/ 238 U in water samples collected from private wells in the Española basin in New Mexico. The document focuses specifically on analyzing variations in the uranium isotopic composition of the different water samples. The data presented in this report were obtained from water samples collected during the fall of 2012. A list of the different sampling locations as identified by their GPS coordinates is presented in Table 1 and represented on a map shown in Figure 1. Water temperature, conductivity, pH, and redox conditions (ORP) were also measured at the time of sampling and are also presented in Table 1. The pH of the samples ranged between 7.10 and 8.49, the temperature between 11.30 and 16.58 ˚C, and the ORP between -182 and 202 mV. The conductivity of the samples was between 454 µS·cm -1 and 1066 µS·cm -1 . The concentration of uranium in the samples varied widely and ranged between 11.5 and 776 µg/L. Uranium isotopic ratios conducted by Thermal Ionization Mass Spectrometry (TIMS) showed natural 238 U/ 235 U within analytical uncertainty. The water samples showed some variations in the isotopic ratios of 234 U/ 238 U, varying from atom ratios of 54.9×10 -6 to 226×10 -6 (activity ratios of 1.00 to 4.11), and indicating enrichment of 234 U in many of the water samples. These isotopic ratios are within the range observed in natural water. Such enrichments in 234 U in natural waters are common and typically attributed to natural processes. There was no detectable 236 U in any of the samples analyzed.

07 ISOTOPE AND RADIATION SOURCES↗

Fast Approximate Union Volume in High Dimensions with Line Samples

The classical problem of calculating the volume of the union of d-dimensional balls is known as "Union Volume." We present line-sampling approximation algorithms for Union Volume. Our methods may be extended to other Boolean operations, such as setminus; or to other shapes, such as hyper-rectangles. The deterministic, exact approaches for Union Volume do not scale well to high dimensions. However, we adapt several of these exact approaches to approximation algorithms based on sampling. We perform local sampling within each ball using lines. We have several variations, depending on how the overlapping volume is partitioned, and depending on whether radial, axis-aligned, or other line patterns are used. Our variations fall within the family of Monte Carlo sampling, and hence have about the same theoretical convergence rate, 1 /$\sqrt{M}$, where M is the number of samples. In our limited experiments, line-sampling proved more accurate per unit work than point samples, because a line sample provides more information, and the analytic equation for a sphere makes the calculation almost as fast. We performed a limited empirical study of the efficiency of these variations. We suggest a more extensive study for future work. We speculate that different ball arrangements, differentiated by the distribution of overlaps in terms of volume and degree, will benefit the most from patterns of line samples that preferentially capture those overlaps. Acknowledgement We thank Karl Bringman for explaining his BF-ApproxUnion (ApproxUnion) algorithm [3] to us. We thank Josiah Manson for pointing out that spoke darts oversample the center and we might get a better answer by uniform sampling. We thank Vijay Natarajan for suggesting random chord sampling. The authors are grateful to Brian Adams, Keith Dalbey, and Vicente Romero for useful technical discussions. This work was sponsored by the Laboratory Directed Research and Development (LDRD) Program at Sandia National Laboratories. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Advanced Scientific Computing Research (ASCR), Applied Mathematics Program. Sandia National Laboratories is a multi-mission laboratory managed and operated by National Technology and Engineering Solutions of Sandia, LLC., a wholly owned subsidiary of Honeywell International, Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA0003525.

97 MATHEMATICS AND COMPUTING↗

Analysis of Tank 38H (HTF-38-18-78, -79) and Tank 43H (HTF-43-18-80, -81, -83) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. Compared with recent samples, the surface and sub-surface samples from Tank 38H show much lower concentrations of most species analyzed except for silicon. The Tank 38H samples show stratification in the tank with the concentration of species in the surface sample being much lower than in the sub-surface sample and both samples being much lower than recent results. The Tank 43H surface and two sub-surface samples generally showed consistent results across the three samples and compare well with recent analyses. The lowest sub-surface sample from Tank 43H contained slightly higher concentrations of uranium and plutonium likely due to the presence of a small amount of dark sludge solids in the sample.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗