Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Characterization of total ionizing dose damage in COTS pinned photodiode CMOS image sensors

The characterization of total ionizing dose (TID) damage in COTS pinned photodiode (PPD) CMOS image sensors (CISs) is investigated. The radiation experiments are carried out at a {sup 60}Co γ-ray source. The CISs are produced by 0.18-μm CMOS technology and the pixel architecture is 8T global shutter pixel with correlated double sampling (CDS) based on a 4T PPD front end. The parameters of CISs such as temporal domain, spatial domain, and spectral domain are measured at the CIS test system as the EMVA 1288 standard before and after irradiation. The dark current, random noise, dark signal non-uniformity (DSNU), photo response non-uniformity (PRNU), overall system gain, saturation output, dynamic range (DR), signal to noise ratio (SNR), quantum efficiency (QE), and responsivity versus the TID are reported. The behaviors of the tested CISs show remarkable degradations after radiation. The degradation mechanisms of CISs induced by TID damage are also analyzed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparison of image noise and image quality between full-dose abdominal computed tomography scans reconstructed with weighted filtered back projection and half-dose scans reconstructed with improved sinogram-affirmed iterative reconstruction (SAFIRE*)

Purpose: To retrospectively compare the image noise, signal-to-noise ratio (SNR), and subjective image quality between CT images acquired with a dual-source, split-dose imaging protocol reconstructed at full and half doses with weighted filtered back projection (wFBP) and an improved sinogram-affirmed iterative reconstruction algorithm (SAFIRE*). Methods: Fifty-three consecutive patients underwent contrast-enhanced CT of the abdomen using a standardized dual-source, single energy CT protocol. Half-dose images were retrospectively generated using data from one detector only. Full-dose datasets were reconstructed with wFBP, while half-dose datasets were reconstructed with wFBP and SAFIRE* strengths 1–5. Region of interest analysis was performed to assess SNR and noise. Diagnostic acceptability, subjective noise, and spatial resolution were graded on a 10-point scale by two readers. Statistical analysis was carried out with repeated measures analysis of variance, Wilcoxon signed rank test, and Cohen’s κ test. Results: With the increasing strengths of SAFIRE*, a progressive reduction in noise and increase in SNR (p < 0.01) was observed. There was a statistically significant decrease in objective noise and increase in SNR in half-dose SAFIRE* strength 4 and 5 reconstructions compared to full-dose reconstructions using wFBP (p < 0.01). Qualitative analysis revealed a progressive increase in diagnostic acceptability, decrease in subjective noise and increase in spatial resolution for half-dose images reconstructed with the increasing strengths of SAFIRE* (p < 0.01). Conclusions: Half-dose CT images reconstructed with SAFIRE* at strength 4 and 5 have superior image quality compared to full-dose images reconstructed with wFBP. SAFIRE* potentially allows dose reductions in the order of 50% over wFBP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of low tube voltage and low iodine concentration abdominal CT on image quality and radiation dose in children: preliminary study

Purpose: To evaluate the image quality of a double-low protocol (low tube voltage and low iodine concentration) for abdominal CT in children. Materials and methods: The double-low protocol was compared to the conventional protocol in pediatric patients weighing less than 40 kg from May 2016 to December 2016. Double-low protocol (Group A, n = 18): tube voltage, 70 kVp; and iodine concentration,: 250 mgI/mL versus Conventional protocol (Group B, n = 13): tube voltage, 80–100 kVp; and iodine concentration, 350 mgI/mL. Mean attenuation, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were compared between the two groups. Image contrast, noise, beam-hardening artifacts, and overall image quality were subjectively scored. Reader performance for correctly differentiating two groups by visual assessment was evaluated. Radiation dose and total iodine load were recorded. Results: The mean attenuations of the portal vein and liver and the mean image noise in Group A were higher than in Group B (p = 0.04, 0.03, 0.004, respectively). The mean SNR and CNR of the main portal vein and liver were lower in Group A without any statistically significant difference. There were no statistically significant differences between the two groups in qualitative analysis (image contrast, image noise, and overall image quality) with substantial agreement between the reviewers (weighted kappa values; 0.59–0.76). Significantly diminished radiation dose and iodine load were observed in Group A compared with Group B (25.0%, 36.8% reduction; p = 0.007, 0.006, respectively). Conclusion: The double-low protocol was feasible for pediatric abdominal CT and reduced both radiation dose and iodine load, while maintaining image quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A statistical method for retrospective cardiac and respiratory motion gating of interventional cardiac x-ray images

Purpose: Image-guided cardiac interventions involve the use of fluoroscopic images to guide the insertion and movement of interventional devices. Cardiorespiratory gating can be useful for 3D reconstruction from multiple x-ray views and for reducing misalignments between 3D anatomical models overlaid onto fluoroscopy. Methods: The authors propose a novel and potentially clinically useful retrospective cardiorespiratory gating technique. The principal component analysis (PCA) statistical method is used in combination with other image processing operations to make our proposed masked-PCA technique suitable for cardiorespiratory gating. Unlike many previously proposed techniques, our technique is robust to varying image-content, thus it does not require specific catheters or any other optically opaque structures to be visible. Therefore, it works without any knowledge of catheter geometry. The authors demonstrate the application of our technique for the purposes of retrospective cardiorespiratory gating of normal and very low dose x-ray fluoroscopy images. Results: For normal dose x-ray images, the algorithm was validated using 28 clinical electrophysiology x-ray fluoroscopy sequences (2168 frames), from patients who underwent radiofrequency ablation (RFA) procedures for the treatment of atrial fibrillation and cardiac resynchronization therapy procedures for heart failure. The authors established end-systole, end-expiration, and end-inspiration success rates of 97.0%, 97.9%, and 97.0%, respectively. For very low dose applications, the technique was tested on ten x-ray sequences from the RFA procedures with added noise at signal to noise ratio (SNR) values of√(5)0, √(1)0, √(8), √(6), √(5), √(2), and √(1) to simulate the image quality of increasingly lower dose x-ray images. Even at the low SNR value of √(2), representing a dose reduction of more than 25 times, gating success rates of 89.1%, 88.8%, and 86.8% were established. Conclusions: The proposed technique can therefore extract useful information from interventional x-ray images while minimizing exposure to ionizing radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Weight-adapted ultra-low-dose pancreatic perfusion CT: radiation dose, image quality, and perfusion parameters

Purpose: We evaluate the reliability and feasibility of weight-adapted ultra-low-dose pancreatic perfusion CT. Methods: A total of 100 (47 men, 53 women) patients were enrolled prospectively and were assigned to five groups (A, B, C, D, and E) with different combination of tube voltage and tube current according to their body weight. Radiation dose parameters including volume CT dose index (CTDI) and dose-length product (DLP) were recorded. Image quality was evaluated both subjectively and objectively (noise, signal-to-noise ratio, contrast-to-noise ratio). Perfusion parameters including blood flow (BF), blood volume (BV), and permeability (PMB) were measured. The dose, image quality measurements, and perfusion parameters were compared between the five groups using one-way analysis of variance (ANOVA). Results: Radiation dose reached 8.7 mSv in patients under 50 kg and was 18.9 mSv in patients above 80 kg. The mean subjective image quality score was above 4.45 on a 5-point scale with good agreement between two radiologists. Groups A–D had equivalent performance on objective image quality (P > 0.05), while Group E performed even better (P < 0.05). No significant differences emerged in comparison with perfusion parameters (BF, BV, PMB) of normal pancreas parenchyma between the five groups. Conclusion: Weight-adapted ultra-low-dose pancreatic perfusion CT can effectively reduce radiation dose without prejudice to image quality, and the perfusion parameters of normal parenchyma are accurate and reliable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First results on ProtoDUNE-SP liquid argon time projection chamber performance from a beam test at the CERN Neutrino Platform

The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber with an active volume of 7.2× 6.1× 7.0 m3. It is installed at the CERN Neutrino Platform in a specially-constructed beam that delivers charged pions, kaons, protons, muons and electrons with momenta in the range 0.3 GeV/c to 7 GeV/c. Beam line instrumentation provides accurate momentum measurements and particle identification. The ProtoDUNE-SP detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment, and it incorporates full-size components as designed for that module. This paper describes the beam line, the time projection chamber, the photon detectors, the cosmic-ray tagger, the signal processing and particle reconstruction. It presents the first results on ProtoDUNE-SP's performance, including noise and gain measurements, dE/dx calibration for muons, protons, pions and electrons, drift electron lifetime measurements, and photon detector noise, signal sensitivity and time resolution measurements. The measured values meet or exceed the specifications for the DUNE far detector, in several cases by large margins. ProtoDUNE-SP's successful operation starting in 2018 and its production of large samples of high-quality data demonstrate the effectiveness of the single-phase far detector design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Processing Methodology for Double Sensor Probe in a Bubbly Flow

Bubbly flow phenomenon is the most common flow pattern in nuclear plant system. In this paper, according to Hibiki and Bartel, the experiment was designed to observe the fluid conditions surrounding nuclear rod. In recent years, double sensor probe is one of the measuring techniques for the bubbly flow. It can measure local void fraction and bubble velocity. After mathematical statistical calculation, interfacial area concentration is obtained by Kataoka. The double sensor probe method, with the advantage for measuring local interfacial area concentration, has become widely used in many measurement methods. The paper of Liu and Zhao were referred to establish the post-processing for the raw data obtained from measuring instrument. After drawing the signal of the probe, it is important to analyze the raw data for the elimination of unnecessary noise signal and highlight the characteristic signal. Based on the same experimental condition, the different filtering methods, Simple Moving Average (SMA) and Gaussian average, were compared and discussed by the double sensor probe.

42 ENGINEERING↗

Homogeneity of spatial correlation statistics of tropical oceanic rainfall

The possibility of uniform horizontal correlation scales for tropical oceanic rainfall has been examined by a study of satellite-observed microwave data as a proxy measure of rain rates. From the brightness temperatures from the electrically scanning microwave radiometer on Nimbus 5 near nadir during the year 1974, the mean spatial autocorrelation function as a function of simultaneous pixel separation was calculated in each 5 by 5 deg grid box over the tropical Pacific and Atlantic for each season. The equal-time spatially lagged correlations were compared for geographical dependence to investigate the hypothesis of homogeneity. A simple model of the spatial statistics of the microwave brightness temperatures was used, consisting of a mixture of uncorrelated spatial white noise incoherently superimposed on a spatially correlated field (spatial red noise). The red noise signals are presumed to be generated by convective activity in the tropical atmosphere. The parameters of the red noise are consistent with this scheme over the tropical oceans, yielding a uniform spatial scale of about 50 km throughout.

Shin, Kyung-Sup↗

Linear Array Ultrasonic Testing Of A Thick Concrete Specimens For Non-Destructive Evaluation

The University of Minnesota and Oak Ridge National Laboratory are collaborating on the design and construction of a concrete specimen with sufficient reinforcement density and cross-sectional size to represent a light water reactor (LWR) containment wall with various defects. The preliminary analysis of the collected data using extended synthetic aperture focussin technique (SAFT) reconstruction indicated a great potential of the ultrasound array technology for locating relatively shallow distresses. However, the resolution and reliability of the analysis is inversely proportional to the defect depth and the amount of reinforcement between the measurement point and the defect location. The objective of this round of testing is to evaluate repeatability of the obtained reconstructions from measurements with different frequencies as well as to examine the effect of the duration of the sending ultrasound signal on the resulting reconstructions. Two series of testing are performed in this study. The objective of the first series is to evaluate repeatability of the measurements and resulting reconstructed images. The measurements use three center frequencies. Five measurements are performed at each location with and without lifting the device. The analysis of the collected data suggested that a linear array ultrasound system can produce reliably repeatable reconstructions using 50 kHz signals for relatively shallow depths (less than 0.5 m). However, for reconstructions at the greater depths the use of lower frequency and/or signal filtering to reduce the effect of signal noise may be required. The objective of the second series of testing is to obtain measurements with various impulse signal durations. The entire grid on the smooth surface is tested with four different various impulse signal durations. An analysis of the resulting extended SAFT reconstructions suggested that Kirchhoff-based migration leads to easier interpreting reconstructions when shorter duration impulse is used. Longer duration impulses may provide useful information for model-based reconstructions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Rare Earth Optical Temperature Sensor

A rare earth optical temperature sensor is disclosed for measuring high temperatures. Optical temperature sensors exist that channel emissions from a sensor to a detector using a light pipe. The invention uses a rare earth emitter to transform the sensed thermal energy into a narrow band width optical signal that travels to a detector using a light pipe. An optical bandpass filter at the detector removes any noise signal outside of the band width of the signal from the emitter.

Donald L Chubb↗

Damping constant estimation in magnetoresistive readers

The damping constant is a key design parameter in magnetic reader design. Its value can be derived from bulk or sheet film ferromagnetic resonance (FMR) line width. However, dynamics of nanodevices is usually defined by presence of non-uniform modes. It triggers new damping mechanisms and produces stronger damping than expected from traditional FMR. This work proposes a device-level technique for damping evaluation, based on time-domain analysis of thermally excited stochastic oscillations. The signal is collected using a high bandwidth oscilloscope, by direct probing of a biased reader. Recorded waveforms may contain different noise signals, but free layer FMR is usually a dominating one. The autocorrelation function is a reflection of the damped oscillation curve, averaging out stochastic contributions. The damped oscillator formula is fitted to autocorrelation data, producing resonance frequency and damping constant values. Restricting lag range allows for mitigation of the impact of other phenomena (e.g., reader instability) on the damping constant. For a micromagnetically modeled reader, the technique proves to be much more accurate than the stochastic FMR line width approach. Application to actual reader waveforms yields a damping constant of ∼0.03.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal Radiometer Signal Processing Using Radiation Hard CMOS Application Specific Integrated Circuits for Use in Harsh Planetary Environments

Thermal radiometers such as proposed for the Europa Clipper flyby mission require low noise signal processing for thermal imaging with immunity to Total Ionizing Dose (TID) and Single Event Latchup (SEL). Described is a second generation Multi- Channel Digitizer (MCD2G) Application Specific Integrated Circuit (ASIC) that accurately digitizes up to 40 thermopile pixels with greater than 50 Mrad (Si) immunity TID and 174 MeV-sq cm/mg SEL. The MCD2G ASIC uses Radiation Hardened By Design (RHBD) techniques with a 180 nm CMOS process node.

Focal Plane Assembly↗

Noise analysis of optimized Ge/Ge{sub 1−x}Sn{sub x}/Ge p–n–p heterojunction phototransistors for long-wavelength optical receivers

Present literature investigates noise analysis and optimal design for Ge/Ge{sub 1−x}Sn{sub x}/Ge based p–n–p heterojunction phototransistors (HPT) for long-wavelength optical receivers. We calculate gain, noise powers, signal-to-noise ratio, absorption coefficient and optical responsivity of proposed GeSn-based HPT and investigate their dependence on various structural parameters to optimize the design. The proposed HPT incorporates Ge{sub 1−x}Sn{sub x} alloy in the base layer as the active layer, allow to extend the photo detection range from near infrared to mid-infrared to achieve a wide range of detection. The results show that the signal-to-noise ratio (SNR) is strongly dependent on the operating frequency and the introduction of Sn in the base layer can improve the signal-to-noise ratio in the high-frequency region. The calculated results also show that even in the presence of small defects and misfit dislocations at the heterointerfaces, high SNR is still achievable for the proposed structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis Background & Noise in Stretched Wire Alignment Technique Measurements

The Stretched-Wire Alignment Technique (SWAT) is one method of magnet alignment for linear induction accelerators. The applications of SWAT have been implemented for aligning solenoid magnets on the Scorpius linear induction accelerator which will be sited at the Nevada National Security Site and the Flash X-Ray (FXR) linear induction accelerator at Lawrence Livermore National Laboratory’s Contained Firing Facility. This article describes both systematic (repeatable) and random sources of background and noise as well as practical ways to eliminate or reduce them to acceptable levels. Systematic sources include reflections from wire ends, rapid sag due to ohmic heating of the wire, magnetic materials, and shot rate. Random sources include air currents, vibration of nearby equipment, mechanical stability of test equipment, and the instruments used to measure the wire motion. Mitigations include curve fitting and adaptive noise signal cancellation, and mechanical damping. Finite Element Analysis (FEA) was used to identify and resolve a repeatable wire vibration frequency interfering with the signal resolution. Two stretched wire alignment technique set ups from Sandia National Labs and Lawrence Livermore National Lab have shown background noise sources and ways of mitigating them by either analysis methods or change of mechanical configuration. Conclusions that were drawn included the severe sensitivity of the deflection to even small external interferences of the SWAT wire such that it requires attention to detail in mechanical set up and analysis.

Linear Inductive Accelerator↗

Correlation of Noise Signature to Pulsed Power Events at the HERMES III Accelerator.

The HERMES III accelerator, which is located at Sandia National Laboratories' Tech Area IV, is the largest pulsed gamma X-ray source in the world. The accelerator is made up of 20 inductive cavities that are charged to 1 MV each by complex pulsed power circuitry. The firing time of the machine components ranges between the microsecond and nanosecond timescales. This results in a variety of electromagnetic frequencies when the accelerator fires. Testing was done to identify the HERMES electromagnetic noise signal and to map it to the various accelerator trigger events. This report will show the measurement methods used to capture the noise spectrum produced from the machine and correlate this noise signature with machine events.

43 PARTICLE ACCELERATORS↗

Photon Sieve Design and Fabrication for Imaging Characteristics Using UAV Flight

The Photon Sieve (PS) team at NASA Langley Research Center (LaRC) began receiving support for the development and characterization of PS devices through the NASA Internal Research & Development Program (IRAD) in 2015. The project involves ascertaining the imaging characteristics of various PS devices. These devices hold the potential to significantly reduce mission costs and improve imaging quality by replacing traditional reflector telescopes. The photon sieve essentially acts as a lens to diffract light to a concentrated point on the focal plane like a Fresnel Zone Plate (FZP). PS’s have the potential to focus light to a very small spot which is not limited by the width of the outermost zone as for the FZP and offers a promising solution for high resolution imaging. In the fields of astronomy, remote sensing, and other applications that require imaging of distant objects both on the ground and in the sky, it is often necessary to perform post-process filtering in order to separate noise signals that arise from multiple scattering events near the collection optic. The PS exhibits a novel filtering technique that rejects the unwanted noise without the need for time consuming post processing of the images. This project leverages key Langley resources to design, manufacture, and characterize a series of photon sieve specimens. After a prototype was developed and characterized in the Langley ISO5 optical cleanroom and laboratory, outside testing was conducted via the capture of images of the moon by using a telescopic setup. This next goal of the project is to design and develop a telescope and image capture system as a drone-based instrument payload. The vehicle utilized for the initial demonstration was a NASA hive model 1200 XE-8 research Unmanned Aerial Vehicle (UAV), capable of handling a 20-pound maximum payload with a 25-minute flight time. This NASA Technical Memorandum (NASA-TM) introduces preliminary results obtained using a PS-based imaging system on the UAV. The next version of the telescope structure will be designed around diffractive optical components and commercially available camera electronics to create a lightweight payload.

Kim, Hyun Jung↗