Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SENSOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

inertial orientation tracker having automatic drift compensation using an at rest sensor for tracking parts of a human body

A self contained sensor apparatus generates a signal that corresponds to at least two of the three orientational aspects of yaw, pitch and roll of a human-scale body, relative to an external reference frame. A sensor generates first sensor signals that correspond to rotational accelerations or rates of the body about certain body axes. The sensor may be mounted to the body. Coupled to the sensor is a signal processor for generating orientation signals relative to the external reference frame that correspond to the angular rate or acceleration signals. The first sensor signals are impervious to interference from electromagnetic, acoustic, optical and mechanical sources. The sensors may be rate sensors. An integrator may integrate the rate signal over time. A drift compensator is coupled to the rate sensors and the integrator. The drift compensator may include a gravitational tilt sensor or a magnetic field sensor or both. A verifier periodically measures the orientation of the body by a means different from the drift sensitive sate sensors. The verifier may take into account characteristic features of human motion, such as stillness periods. The drift compensator may be, in part, a Kalman filter, which may utilize statistical data about human head motion.

Foxlin, Eric M.↗

Multi-sensor Testing for Automated Rendezvous and Docking

During the past two years, many sensors have been tested in an open-loop fashion in the Marshall Space Flight Center (MSFC) Flight Robotics Laboratory (FRL) to both determine their suitability for use in Automated Rendezvous and Docking (AR&D) systems and to ensure the test facility is prepared for future multi-sensor testing. The primary focus of this work was in support of the CEV AR&D system, because the AR&D sensor technology area was identified as one of the top risks in the program. In 2006, four different sensors were tested individually or in a pair in the MSFC FRL. In 2007, four sensors, two each of two different types, were tested simultaneously. In each set of tests, the target was moved through a series of pre-planned trajectories while the sensor tracked it. In addition, a laser tracker "truth" sensor also measured the target motion. The tests demonstrated the functionality of testing four sensors simultaneously as well as the capabilities (both good and bad) of all of the different sensors tested. This paper outlines the test setup and conditions, briefly describes the facility, summarizes the earlier results of the individual sensor tests, and describes in some detail the results of the four-sensor testing. Post-test analysis includes data fusion by minimum variance estimation and sequential Kalman filtering. This Sensor Technology Project work was funded by NASA's Exploration Technology Development Program.

Howard, Richard T.↗

Application of High-Temperature Extrinsic Fabry-Perot Interferometer Strain Sensor

In this presentation to the NASA Aeronautics Sensor Working Group the application of a strain sensor is outlined. The high-temperature extrinsic Fabry-Perot interferometer (EFPI) strain sensor was developed due to a need for robust strain sensors that operate accurately and reliably beyond 1800 F. Specifically, the new strain sensor would provide data for validating finite element models and thermal-structural analyses. Sensor attachment techniques were also developed to improve methods of handling and protecting the fragile sensors during the harsh installation process. It was determined that thermal sprayed attachments are preferable even though cements are simpler to apply as cements are more prone to bond failure and are often corrosive. Previous thermal/mechanical cantilever beam testing of EFPI yielded very little change to 1200 F, with excellent correlation with SG to 550 F. Current combined thermal/mechanical loading for sensitivity testing is accomplished by a furnace/cantilever beam loading system. Dilatometer testing has can also be used in sensor characterization to evaluate bond integrity, evaluate sensitivity and accuracy and to evaluate sensor-to-sensor scatter, repeatability, hysteresis and drift. Future fiber optic testing will examine single-mode silica EFPIs in a combined thermal/mechanical load fixture on C-C and C-SiC substrates, develop a multi-mode Sapphire strain-sensor, test and evaluate high-temperature fiber Bragg Gratings for use as strain and temperature sensors and attach and evaluate a high-temperature heat flux gauge.

Piazza, Anthony↗

Testing of a Microwave Blade Tip Clearance Sensor at the NASA Glenn Research Center

The development of new active tip clearance control and structural health monitoring schemes in turbine engines and other types of rotating machinery requires sensors that are highly accurate and can operate in a high temperature environment. The use of a microwave sensor to acquire blade tip clearance and tip timing measurements is being explored at the NASA Glenn Research Center. The microwave blade tip clearance sensor works on principles that are very similar to a short range radar system. The sensor sends a continuous microwave signal towards a target and measures the reflected signal. The phase difference of the reflected signal is directly proportional to the distance between the sensor and the target being measured. This type of sensor is beneficial in that it has the ability to operate at extremely high temperatures and is unaffected by contaminants that may be present in turbine engines. The use of microwave sensors for this application is a new concept. Techniques on calibrating the sensors along with installation effects are not well quantified as they are for other sensor technologies. Developing calibration techniques and evaluating installation effects are essential in using these sensors to make tip clearance and tip timing measurements. As a means of better understanding these issues, the microwave sensors were used on a bench top calibration rig, a large axial vane fan, and a turbofan. Background on the microwave tip clearance sensor, an overview of their calibration, and the results from their use on the axial vane fan and the turbofan will be presented in this paper.

Woike, Mark R.↗

Testing of a Microwave Blade Tip Clearance Sensor at the NASA Glenn Research Center

The development of new active tip clearance control and structural health monitoring schemes in turbine engines and other types of rotating machinery requires sensors that are highly accurate and can operate in a high-temperature environment. The use of a microwave sensor to acquire blade tip clearance and tip timing measurements is being explored at the NASA Glenn Research Center. The microwave blade tip clearance sensor works on principles that are very similar to a short-range radar system. The sensor sends a continuous microwave signal towards a target and measures the reflected signal. The phase difference of the reflected signal is directly proportional to the distance between the sensor and the target being measured. This type of sensor is beneficial in that it has the ability to operate at extremely high temperatures and is unaffected by contaminants that may be present in turbine engines. The use of microwave sensors for this application is a new concept. Techniques on calibrating the sensors along with installation effects are not well quantified as they are for other sensor technologies. Developing calibration techniques and evaluating installation effects are essential in using these sensors to make tip clearance and tip timing measurements. As a means of better understanding these issues, the microwave sensors were used on a benchtop calibration rig, a large axial vane fan, and a turbofan. Background on the microwave tip clearance sensor, an overview of their calibration, and the results from their use on the axial vane fan and the turbofan will be presented in this paper.

Woike, Mark R.↗

Analyzing Responses of Chemical Sensor Arrays

NASA is developing a third-generation electronic nose (ENose) capable of continuous monitoring of the International Space Station s cabin atmosphere for specific, harmful airborne contaminants. Previous generations of the ENose have been described in prior NASA Tech Briefs issues. Sensor selection is critical in both (prefabrication) sensor material selection and (post-fabrication) data analysis of the ENose, which detects several analytes that are difficult to detect, or that are at very low concentration ranges. Existing sensor selection approaches usually include limited statistical measures, where selectivity is more important but reliability and sensitivity are not of concern. When reliability and sensitivity can be major limiting factors in detecting target compounds reliably, the existing approach is not able to provide meaningful selection that will actually improve data analysis results. The approach and software reported here consider more statistical measures (factors) than existing approaches for a similar purpose. The result is a more balanced and robust sensor selection from a less than ideal sensor array. The software offers quick, flexible, optimal sensor selection and weighting for a variety of purposes without a time-consuming, iterative search by performing sensor calibrations to a known linear or nonlinear model, evaluating the individual sensor s statistics, scoring the individual sensor s overall performance, finding the best sensor array size to maximize class separation, finding optimal weights for the remaining sensor array, estimating limits of detection for the target compounds, evaluating fingerprint distance between group pairs, and finding the best event-detecting sensors.

Zhou, Hanying↗

Semiautonomous Avionics-and-Sensors System for a UAV

Unmanned Aerial Vehicles (UAVs) autonomous or remotely controlled pilotless aircraft have been recently thrust into the spotlight for military applications, for homeland security, and as test beds for research. In addition to these functions, there are many space applications in which lightweight, inexpensive, small UAVS can be used e.g., to determine the chemical composition and other qualities of the atmospheres of remote planets. Moreover, on Earth, such UAVs can be used to obtain information about weather in various regions; in particular, they can be used to analyze wide-band acoustic signals to aid in determining the complex dynamics of movement of hurricanes. The Advanced Sensors and Electronics group at Langley Research Center has developed an inexpensive, small, integrated avionics-and-sensors system to be installed in a UAV that serves two purposes. The first purpose is to provide flight data to an AI (Artificial Intelligence) controller as part of an autonomous flight-control system. The second purpose is to store data from a subsystem of distributed MEMS (microelectromechanical systems) sensors. Examples of these MEMS sensors include humidity, temperature, and acoustic sensors, plus chemical sensors for detecting various vapors and other gases in the environment. The critical sensors used for flight control are a differential- pressure sensor that is part of an apparatus for determining airspeed, an absolute-pressure sensor for determining altitude, three orthogonal accelerometers for determining tilt and acceleration, and three orthogonal angular-rate detectors (gyroscopes). By using these eight sensors, it is possible to determine the orientation, height, speed, and rates of roll, pitch, and yaw of the UAV. This avionics-and-sensors system is shown in the figure. During the last few years, there has been rapid growth and advancement in the technological disciplines of MEMS, of onboard artificial-intelligence systems, and of smaller, faster, and smarter wireless telemetry systems. The major attraction of MEMS lies in orders-of-magnitude reductions of power requirements relative to traditional electronic components that perform equivalent functions. In addition, the compactness of MEMS, relative to functionally equivalent traditional electronics systems, makes MEMS attractive for UAV applications. Recent advances in MEMS have made it possible to produce pressure, acceleration, humidity, and temperature sensors having masses in subgram range and possessing sensitivities and accuracies comparable to those of larger devices.

Shams, Qamar↗

Real-time method for establishing a detection map for a network of sensors

A method for establishing a detection map of a dynamically configurable sensor network. This method determines an appropriate set of locations for a plurality of sensor units of a sensor network and establishes a detection map for the network of sensors while the network is being set up; the detection map includes the effects of the local terrain and individual sensor performance. Sensor performance is characterized during the placement of the sensor units, which enables dynamic adjustment or reconfiguration of the placement of individual elements of the sensor network during network set-up to accommodate variations in local terrain and individual sensor performance. The reconfiguration of the network during initial set-up to accommodate deviations from idealized individual sensor detection zones improves the effectiveness of the sensor network in detecting activities at a detection perimeter and can provide the desired sensor coverage of an area while minimizing unintentional gaps in coverage.

47 OTHER INSTRUMENTATION↗

Assessment of Flow-Enhanced Sensors for Actinide Quantification in MSRs

This report serves as the deliverable for Milestone M2RS-22AN0401062 that is part of Work Package RS-22AN040106 (Flow Enhanced Sensors for MSRs – ANL). The goal of this milestone is to assess the capabilities of flow-enhanced electrochemical sensors (FEES) to quantify actinides in molten salt reactors. Flow enhanced electrochemical sensors are a type of electroanalytical sensor that has been developed at Argonne National Laboratory to be installed directly into MSR flow conduits in order to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. To support this work, Argonne constructed a molten salt flow system to serve as a testbed for the development of safeguards and process monitoring-relevant sensors in challenging molten salt flow conditions. Through extensive flow testing using UCl3-bearing salts, Argonne has been able to show that the FEES are able to make good measurements of salt composition. Concentration measurements with a mean absolute error of 0.09 wt% have been achieved for representative fuel salt mixtures across a range of UCl3 loadings. Repeatability was also good, with the relative standard deviation from repeated measurements being less than 1.0%. These sensors have also been shown to be able to measure the flow rate of the salt within the flow system’s transfer line. Although the accuracy of the sensors has been good, the sensors have thus far not been able to achieve performance good enough to satisfy the nuclear material accountancy requirements in 10 CFR 74. To do so, accuracy levels of 0.1% must be achieved; the FEES when operated in Argonne’s flow system have so far only been able to achieve relative errors of approximately 5.0%. Much of the error that has been observed at this stage is due to challenges in maintaining a stable salt composition in the molten salt flow system, and it is not believed that there are any inherent flaws in the sensor design. Nonetheless, the high degree of accuracy required by 10 CFR 74 represents a significant challenge, and further design evolution and integration of the sensors into multimodal sensing frameworks will likely be needed to push the measurement accuracy to the needed level.

Moore, Colin E.↗

Field Test of High Temperature Corrosion Sensors in a Waste to Energy Plant

A field trial of electrochemical corrosion rate sensors was conducted over a five month period to monitor fireside corrosion in a waste to energy (WTE) plant. The unique 3-electrode air-cooled corrosion sensors, each including a thermocouple to monitor sensor temperature, were installed in four different ports at approximately the same level of the WTE boiler. A total of twelve sensors were tested, six with electrodes using the carbon steel boiler tube material, and six using the nickel-chromium weld overlay alloy for the electrodes. Corrosion rates and temperatures of the sensors were monitored continuously through the trial. Measurements of sensor thickness loss were used to calibrate the electrochemical corrosion rates. Air cooling of the sensors was found to be necessary in order to bring the sensors to the temperature of the boiler tubes, to better match the corrosion rate of the tubes, and to increase survivability of the sensors and thermocouples. Varying the temperature of the sensors simulated corrosion rates of boiler tubes with steam temperatures above and below that in the actual WTE plant. Temperatures of two of the sensors were successfully held at various controlled temperatures close to the steam temperature for a three hour test period. Corrosion rates of the two materials tested were similar although of different magnitude. An expression relating the corrosion rate of the boiler tube material to the corrosion rate of weld overlay was determined for a 7 day period in the middle of the field trial. Results from the field trial suggest that corrosion rate sensors controlled to the outer waterwall temperature can successfully monitor fireside corrosion in WTE plants and be used as a process control variable by plant operators.

36 MATERIALS SCIENCE↗

Oscillatory motion based measurement method and sensor for measuring wall shear stress due to fluid flow

A shear stress sensor for measuring fluid wall shear stress on a test surface is provided. The wall shear stress sensor is comprised of an active sensing surface and a sensor body. An elastic mechanism mounted between the active sensing surface and the sensor body allows movement between the active sensing surface and the sensor body. A driving mechanism forces the shear stress sensor to oscillate. A measuring mechanism measures displacement of the active sensing surface relative to the sensor body. The sensor may be operated under periodic excitation where changes in the nature of the fluid properties or the fluid flow over the sensor measurably changes the amplitude or phase of the motion of the active sensing surface, or changes the force and power required from a control system in order to maintain constant motion. The device may be operated under non-periodic excitation where changes in the nature of the fluid properties or the fluid flow over the sensor change the transient motion of the active sensor surface or change the force and power required from a control system to maintain a specified transient motion of the active sensor surface.

47 OTHER INSTRUMENTATION↗

Sensor impacts on building and HVAC controls: A critical review for building energy performance

Building operations rely heavily on control systems and sensors. This paper provides a sophisticated literature review on sensor systems in building/HVAC systems, particularly in the context of controls, and their impacts on energy efficiency and thermal comfort. This study aims to understand the previous and current research and identify future research opportunities on this subject. The reviewed sensor systems were used for heuristic rule-based controls, local controls, and advanced optimal controls for existing and emerging technologies. Five major aspects of sensors are reviewed here: control loops for sensors, sensor types, sensor locations, sensor data, and a sensor impact evaluation framework. To augment the literature review, comprehensive standardized interviews were also conducted with relevant industry experts and practitioners. These interviews were designed and performed to (1) identify significant factors for selecting sensor sets and current undergoing issues, (2) identify potential improvements in sensor configuration/deployment, and (3) integrate expert (e.g., researcher, building operation practitioner) knowledge and experiences to develop structured use-case scenarios. Researchers collected and analyzed 31 interview responses for this paper.

Building control↗

Development and testing of a performance evaluation methodology to assess the reliability of occupancy sensor systems in residential buildings

With the emergence of advanced occupancy sensor technologies to better detect occupancy in buildings, a universal methodology and metrics are required to evaluate and report sensor systems’ reliability and compare the performance across multiple sensor systems. Herein this research presents a methodology to assess the reliability of occupancy sensor systems in residential buildings in a controlled laboratory environment, including both “typical” and “failure” testing scenarios. The developed methodology was then implemented to evaluate a novel occupancy detection sensor system’s reliability. “Typical” testing evaluates the overall accuracy of the sensor system, which suggest how reliable the occupancy sensor system is over time. Results show that on average, the precision and recall are 0.75 and 0.70, indicating similar numbers of false positives and false negatives across the dataset. The overall accuracy of the tested sensor system was 62.4% to 76.4%. Failure testing results indicate whether there are influential variables impacting the sensor performance. For the tested sensor system, the number of occupants, presence of large objects, presence of interior light sources, and number of doors are not influential, while lighting level, location of occupants, additional door in the entry/exit area, and having the TV on are variables determined to impact the sensor system performance.

47 OTHER INSTRUMENTATION↗

A portable and reusable sensor system based on graphene for real-time and sensitive detection of lead ions in water

Long-term exposure to Pb 2+ can cause irreversible damage to the nervous, cardiovascular, and reproductive systems. Therefore, developing a fast and sensitive detection system capable of monitoring minuscule concentrations of Pb 2+ is essential. In this study, we demonstrated a fully portable sensor system enabling rapid, sensitive, and real-time monitoring of Pb 2+ . The sensor system adopted the remote-gate field-effect transistor (RGFET) detection scheme and was easy to operate, even for non-experts. The sensor system comprised two printed circuit boards (PCBs): a sensor PCB with a remote-gate electrode and an analyzer PCB with a metal-oxide-semiconductor field-effect transistor (MOSFET) transducer and peripheral electronics to manage sensor signals. To achieve a high sensitivity for Pb 2+ , we utilized graphene ink drop-casted on the sensor PCB as a sensing membrane. The graphene film was easy to deposit and remove, enabling the sensor PCB to be reused multiple times. The sensor system was further linked to a smartphone application that instantly monitors the sensor response, allowing for rapid point-of-use detection. The sensor exhibited a high sensitivity of 21.7% when the limit of detection (LOD) value of 1 nM (∼0.2 ppb) was detected, and the typical detection time for each sample was approximately 60 seconds. This portable sensor system advances sensing technologies and could potentially supplement expensive, laborious conventional sensing equipment.

54 ENVIRONMENTAL SCIENCES↗

Passively-Powered Adaptively-Located Flexible Hybrid Sensors Final Report

PARC, a Xerox Company, is developing a low-cost system of peel-and-stick wireless sensors that will enable widespread building environment sensor deployment with the potential to deliver up to 30% energy savings. The system is embodied by a set of RF hubs that provide power to the automatically located sensor nodes, and relays data wirelessly to the building management system (BMS). The sensor nodes are flexible electronic labels powered by rectified RF energy transmitted by a RF hub and can contain multiple printed and conventional sensors. The system design overcomes limitations in wireless sensors related to power delivery, lifetime, and cost by eliminating batteries and photovoltaic devices. The sensor label can be equipped with a variety of printed and conventional sensors for building energy optimization, including lighting, occupancy, temperature, humidity, motion, and air quality. A key advantage of this system is its ability to automatically locate multiple sensor nodes to within 0.5 m (at a 5-m read distance) for simplified commissioning, as well as its interoperability with a wide range of existing BMS hardware and software. This enables automatic sensor reconfiguration and recommissioning, which is an important cost reduction driver. Moreover, the sensors are compatible with low-cost-, high-throughput roll-to-roll manufacturing, further reducing system costs. Upon successfully developing, manufacturing and deploying the system with optimized control, it can lead to annual primary energy savings >280 TBtu in offices, and up to ~1850 TBtu in combined offices and residences. The technology is based on PARC innovations in small antenna design, efficient RF energy capture, and flexible electronics. PARC is a leader in flexible hybrid integration similar to what is used in current RFID tags, which will provide a low-cost system in a flexible form factor. Our team member, Energy ETC, is a leader in supplier-agnostic BMS deployments, and will design the commissioning and deployment procedures to maximize system interoperability. The project will result in a demonstrator that will provide temperature and humidity data and will be wirelessly integrated into PARC’s BMS.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Distributed Wireless Antenna Sensors for Boiler Condition Monitoring

Monitoring the operational conditions of coal-fired boilers is an important task that could bring tremendous benefits, including in-situ process control, real-time health assessment of structural components, improved heat transfer efficiency, reduced downtime, etc. Moreover, in-situ distributed sensing of the boiler conditions would provide large scale in-situ measurement data that will help us gain fundamental understandings of the combustion and heat transfer processes as well as enable the developments of new simulation tools, which could eventually lead to better design and more efficient operation of the boilers. The objectives of this research were to (a) develop wireless passive antenna sensors without electronics; (b) demonstrate multi-modality sensing using a signal antenna sensor; and (c) fabricate the antenna sensor from high-temperature materials. In this project, we have demonstrated that an antenna sensor or sensor array without any electronics can be wirelessly interrogated from a distance. In addition, a low-cost compact wireless sensor interrogator was developed for dynamic interrogation of the passive antenna sensor. We validated that a dual-frequency antenna sensor is capable of simultaneous strain and temperature measurements or temperature and ash accumulation measurements; all parameters are relevant to boiler condition monitoring. By measuring the temperature and ash accumulation height simultaneously, the dielectric constant of the ash as well as its temperature dependency can also be characterized. This capability could lead to potential applications of the antenna sensor for combustion process monitoring based on the ash composition. We also investigated different techniques of fabricating the antenna sensor using high-temperature materials such as alumina substrate and platinum paste and characterized the thermal response of the antenna sensor. A linear relationship between the antenna resonant frequency and the temperature change was validated.

20 FOSSIL-FUELED POWER PLANTS↗

A Review of Existing Test Methods for Occupancy Sensors

One of the key new features of connected lighting systems (CLS) is their ability to collect data from various types of integral sensors and share that data with other lighting or building systems. Occupancy and vacancy sensors have been widely adopted as an energy-saving strategy in buildings, yet published test methods for reproducibly characterizing their performance remain few and limited in their sophistication. As a result, it has been difficult to predict their performance in a specific application, and in practice, they frequently do not meet energy-savings expectations. Occupants at times remove or otherwise bypass occupancy sensors that hinder their work or otherwise do not perform as expected, thereby compromising the sensors’ potential to reduce energy consumption. Poor performance can result from multiple causes – ranging from fundamental limitations of the sensor technology, to misconfiguration, to poor placement in the room or space. Innovative occupancy sensors, some of them combining multiple sensing technologies, have come on the market over the years, with claims of improved performance compared to their predecessors; yet in practice, their performance has led to neither high deployment nor high user satisfaction in any significant application, nor has it differed enough from the performance of previous products to necessitate a test method that facilitated comparison between them. While the performance of both common and novel occupancy sensors has been the subject of many published research articles, the test methods that have been employed for them have typically been loosely described and incorporated custom equipment or techniques that render them difficult to reproduce, or have been limited in their ability to fairly characterize devices that utilize varying sensor technology. The lack of a well-described, technology-agnostic test method that yields reproducible results across different implementations has been a barrier to the commercial success of new occupancy sensor products, as users and specifiers who have been disappointed with previous products are often unwilling to take a chance with new ones. Motivated by a desire to fairly characterize new technologies that continue to enter the market and claim not only improved occupancy detection but, in some cases, also additional capabilities (e.g., the ability to measure traffic or discern between different object types), this report presents the results of a literature review of recent published, well-described test methods for characterizing occupancy sensor performance, as well as research articles containing ad-hoc test methods. The review also identifies and consolidates the best techniques for characterizing sensor performance in indoor spaces and identifies test method gaps that need to be filled in order to evaluate emerging technologies and products.

47 OTHER INSTRUMENTATION↗

Spectroelectrochemical Sensor for Pertechnetate Applicable to Hanford and Other DOE Sites

During the period of this grant several significant milestones have been passed pursuant to designing a fluorescence sensor for pertechnetate (TcO4-). They are as follows: Fluorescence spectroelectrochemistry and less than picomolar limit of detection for a model non-radioactive analyte have been demonstrated. The spectroelectrochemical sensor and associated instrumentation for fluorescence mode of operation have been made, are portable, and easily transported to and used at DOE sites. The sensor has sufficient selectivity for its application to complex samples, even including tank waste, that exist at DOE sites such as the Hanford Site. Pertechnetate has been preconcentrated in sensor films and electrochemically reduced. This is the first critical step in operation of a spectroelectrochemical sensor for TcO4-. New Tc complexes have been made that fluoresce and these complexes have been preconcentrated and electrochemically modulated in a sensor film leading to fluorescence modulation, which is the second critical step in operation of the spectroelectrochemical sensor for TcO4-. We have determined that fluorescence offers a means of dramatically improving the limit of detection. Based on measurements on our new fluorescent complexes of Tc, we estimate the limit of detection for the sensor to be 5 x 10-12M. In related work, we have shown that the sensitivity of the spectroelectrochemical sensor for some metal cations can be improved by forming a metal complex with better optical and electrochemical properties. In addition, some heavy metals can be detected with the spectroelectrochemical sensor by depositing them directly as metals on the sensor surface.

54 ENVIRONMENTAL SCIENCES↗