Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCINTILLATION COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Clinical Trials of a Urethral Dose Measurement System in Brachytherapy Using Scintillation Detectors

Purpose: To report on the clinical feasibility of a novel scintillation detector system with fiberoptic readout that measures the urethral dose during high-dose-rate brachytherapy treatment of the prostate. Methods and Materials: The clinical trial enrolled 24 patients receiving high-dose-rate brachytherapy treatment to the prostate. After the first 14 patients, three improvements were made to the dosimeter system design to improve clinical reliability: a dosimeter self-checking facility; a radiopaque marker to determine the position of the dosimeter, and a more robust optical extension fiber. Results: Improvements to the system design allowed for accurate dose measurements to be made in vivo. A maximum measured dose departure of 9% from the calculated dose was observed after dosimeter design improvements. Conclusions: Departures of the measured from the calculated dose, after improvements to the dosimetry system, arise primarily from small changes in patient anatomy. Therefore, we recommend that patient response be correlated with the measured in vivo dose rather than with the calculated dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sub-nanosecond Half-life Measurement of the Yrast I{sup π}=5{sup −} State in the N=78 Nucleus {sup 136}{sub 58}Ce using Fast-timing Coincident Gamma-ray Spectroscopy

We report on the measurement of the half-life of the yrast I{sup π}=5{sup −} state in the transitional nucleus {sup 136}Ce using a combined HPGe-LaBr3(Ce) scintillator gamma-ray detection array. The measured value for the E1 decay is approximately half a nanosecond, which corresponds to an E1 decay strength of approximately 2×10{sup −6} Wu. This value is in line with single-particle type E1 decays in this mass region and suggests no sign of additional K-hindrance associated with axially symmetric quadrupole deformations observed for lighter cerium isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Summary of the COSY-11 Measurements of Hyperon Production

The studies of hyperon production performed at COSY-11 are summarized. The results of the experiments in the reaction channels pp{yields}pK{sup +}{lambda}, pp{yields}pK{sup +}{sigma}{sup 0}, and pp{yields}nK{sup +}{sigma}{sup +} are shown. Excitation functions from threshold up to about 90 MeV excess energies have been evaluated with high precision for the {lambda} and {sigma}{sup 0} production. The {lambda}p and {sigma}{sup 0}p final state interactions were extracted. The {sigma}{sup +} production was measured at 13 and 60 MeV excess energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Light-Nuclei identification with PAMELA space telescope: preliminary in-flight results

The observational objectives of the PAMELA space telescope, launched the 15th of June 2006, are to measure the spectra of antiprotons, positrons and nuclei in a wide range of energies, to search for primordial antimatter as well as the determination of light nuclei fluxes from hydrogen to oxygen in a wide energy range and with very high statistics. Data gathered with the PAMELA instrument will deal with a wide range of fundamental issues like the understanding of the acceleration, propagation and trapping mechanism of cosmic rays in our Galaxy. In this paper preliminary results on the charge discrimination capabilities of PAMELA for light nuclei will be presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Muon Range Detector at SciBooNE

SciBooNE is a new neutrino experiment at Fermilab. The detector will undertake a number of measurements, principally sub-GeV neutrino cross-section measurements applicable to T2K. The detector consists of 3 sub-detectors; SciBar and the Electron-Catcher were both used in the K2K experiment at KEK, Japan, whilst the Muon Range Detector is a new detector constructed at Fermilab using recycled materials from previous Fermilab experiments. A description of the detector, its construction and software is presented here.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The electron catcher (EC) of SciBooNE

In this paper we describe the electromagnetic calorimeter of the SciBooNE experiment. First we will give some technical details and then we will describe the response of this detector to electrons and muons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The SciBooNE Experiment

The SciBar Booster Neutrino Experiment (SciBooNE) is a neutrino scattering experiment located at Fermilab that started to take data in June 2007. The experiment takes advantage of the excellent and well understood SciBar detector from K2K and of the Booster Neutrino Beam from Fermilab. The main SciBooNE goal is to measure the total neutrino and antineutrino cross-sections at low energies with unprecedented statistics. These measurements will help to improve the results of T2K and MiniBooNE neutrino oscillation experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Asymmetry of Charge Ratio for Low Energetic Muons

The WILLI calorimeter, installed in NIPNE Bucharest, is operated since several years for measuring charge ratio of atmospheric muons at low energies (E<1 GeV), particularly exploring its directional dependence. Measurements of the muon flux are compared with Monte-Carlo simulation with CORSIKA code. Recently WILLI detector is proposed to get extended with a by mini-array of 12 scintillators (WILLI-EAS) in order to measure muon charge ratio of the muon density of EAS lateral distributions. Experimental studies of this kind could provide detailed information on the shower development under the influence of the geomagnetic field and also on features of the hadronic interaction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation of the EAS Lateral Particle Density at 500 m Distance from Shower Core

For the experimental conditions of the KASCADE-Grande experiment, the density of EAS charged particles at the distance of about 500 m from the shower core S(500) has been shown by detailed simulation studies to be an approximate energy estimator, being nearly independent of the mass of the primary particle. This report presents some experimentally observed features of the S(500) observable registered with the KASCADE-Grande array installed at the Forschungszentrum Karlsruhe, Germany The measured energy deposits of particles in the 37 scintillation detector stations have been used to reconstruct the lateral charged particle distributions that are described by a Linsley parameterization (LDF). Among other features, the S(500) dependence from the EAS angle of incidence has been studied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Fast Measurement System of Neutron Emission Profile Using a Digital Signal Processing Technique in JT-60U

Neutron emission profiles are routinely measured in JT-60U Tokamak. Stinbene neuron detectors (SNDs), which combine a Stilbene organic crystal scintillation detector (Stilbene detector) with an analog neutron-gamma pulse shape discrimination (PSD) circuit, have been used to measure neutron flux efficiently. Although the SND has many advantages as a neutron detector, the maximum count rate is limited up to {approx}1x 10{sup 5} counts/s due to the dead time of the analog PSD circuit. To overcome this issue, a digital signal processing (DSP) system using a Flash-ADC has been developed. In this system, anode signals from the photomultiplier of the Stilbene detector are fed to the Flash ADC and digitized. Then, the PSD between neutrons and gamma-rays are performed using software. The photomultiplier tube is also modified to suppress and correct gain fluctuation of the photomultiplier. The DSP system has been installed in the center channel of the vertical neutron collimator system in JT-60U and applied to measurements of neutron flux in JT-60U experiments. Neutron flux are successfully measured with count rate up to {approx}1x 10{sup 6} counts/s without the effect of pile up of detected pulses. The performance of the DSP system as a neutron detector is demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Processing of the Signals From Plasma Focus Discharge

Recent experiments of D-D reactions at the PF-1000 device in IPPLM Warsaw made possible to determine more exactly the time and energy distribution of produced neutrons due to ten scintillation detectors placed at distances between 7 and 85 m from the neutron source in both axial directions. In this article the de-noising of neutron signal via wavelet transformation is described. The signals were filtered with using the discrete wavelet transformation. The Mallat multiresolution algorithm was used, which divides the signal using decomposition coefficients and a hard. This method was used for filtration of the neutron signals acquired from D-D fusion reaction at the device PF 1000 in IPPLM Warsaw. We present comparison of detected and reconstructed signals and a temporal evolution of neutron energy distribution for shot No. 6573.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of D-D Reaction at the Plasma Focus Device

The plasma focus device PF-1000 at IPPLM Warsaw with neutron yields of 10{sup 9}-10{sup 11} neutrons per shot is convenient for the determination of the axial neutron energy distribution in the fusion D-D reaction due to the horizontal position of a discharge axis and the distance of scintillation detectors up to 85 m from the neutron source in both axial (downstream and upstream) directions. In this paper the determination of the axial energy component of the fast deuterons producing neutrons is presented for the shot with a relative small neutron yield and nearly isotropic neutron energy distribution and the total energy of fast deuterons producing neutrons is estimated. We calculated, if the dense structure with the length of 2 cm and the density of 2xl0{sup 25} m{sup -3} could be the source of neutrons. We estimated the upper limit of energy of deuterons producing neutrons as 10-20 keV and their total number as 10{sup 18}. The deuterons with energies below 10-20 keV can't produce high number of neutrons due to the small cross-section of D-D reaction but they can be principally confined by magnetic field. We discuss the influence of magnetic field on the motion of deuterons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Particle Detectors: Research and Development at CERN

Over the past 15 years a worldwide Detector R and D Programme has made the LHC experiments possible. These experiments operate at a new level of event rate and detection capabilities. Based on these advances, Detector R and D is continuing at CERN in close collaboration with University and Research Institutes. Several main directions are being pursued for solid-state and gaseous tracking devices, advanced crystal and noble liquid calorimetry, particle identification methods, and advanced signal-processing techniques. This effort is directed towards experiments at even higher collision rates at the LHC, the requirements for the next generation of linear electron-positron colliders and for applications outside particle physics, such as medical diagnostics instrumentation. We shall illustrate this challenging, stimulating and creative programme with examples and show how these developments are taking place in close collaboration between CERN and institutions around the globe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron capture and inelastic scattering cross sections for {sup 186}Os, {sup 187}Os, and {sup 189}Os and the Re-Os chronology

We measured the neutron capture cross sections of {sup 186,187,189}Os taking for the first time their pulse height spectra for neutrons between 5 and 90 keV by means of an anti-Compton NaI(Tl) spectrometer. The neutron inelastic scattering cross section for {sup 187}Os as well as the neutron elastic scattering cross sections for {sup 186,187}Os were also observed with use of {sup 6}Li-glass scintillation detectors with a small systematic uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Generation and dose distribution measurement of flash x-ray in KALI-5000 system

Flash x-ray generation studies have been carried out in KALI-5000 Pulse power system. The intense relativistic electron beam has been bombarded on a tantalum target at anode to produce flash x-ray via bremsstrahlung conversion. The typical electron beam parameter was 360 kV, 18 kA, and 100 ns, with a few hundreds of A/cm{sup 2} current density. The x-ray dose has been measured with calcium sulfate:dysposium (CaSO{sub 4}:Dy) thermoluminescent dosimeter and the axial dose distribution has been characterized. It has been observed that the on axis dose falls of with distance {approx}1/x{sup n}, where n varies from 1.8 to 1.85. A maximum on axis dose of 46 mrad has been measured at 1 m distance from the source. A plastic scintillator with optical fiber coupled to a photomultiplier tube has been developed to measure the x-ray pulse width. The typical x-ray pulse width varied from 50 to 80 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Controlling the Neutron Yield from a Small Dense Plasma Focus using Deuterium-Inert Gas Mixtures

The dense plasma focus (DPF) is a well known source of neutrons when operating with deuterium. The DPF is demonstrated to scale from 10{sup 4} n/pulse at 40 kA to >10{sup 12} n/pulse at 2 MA by non-linear current scaling as described in [1], which is itself based on the simple yet elegant model developed by Lee [2]. In addition to the peak current, the gas pressure controls the neutron yield. Recent published results suggest that mixing 1-5% mass fractions of Krypton increase the neutron yield per pulse by more than 10x. In this paper we present results obtained by mixing deuterium with Helium, Neon and Argon in a 500 J dense plasma focus operating at 140 kA with a 600 ns rise time. The mass density was held constant in these experiments at the optimum (pure) deuterium mass density for producing neutrons. A typical neutron yield for a pure deuterium gas charge is 2x10{sup 6}{+-}15% n/pulse. Neutron yields in excess of 10{sup 7}{+-}10% n/pulse were observed with low mass fractions of inert gas. Time integrated optical images of the pinch, soft x-ray measurements and optical emission spectroscopy where used to examine the pinch in addition to the neutron yield monitor and the fast scintillation detector. Work supported by Domestic Nuclear Detection Office under contract HSHQDC-08-C-00020.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scintillator based detector for fast-ion losses induced by magnetohydrodynamic instabilities in the ASDEX upgrade tokamak

A scintillator based detector for fast-ion losses has been designed and installed on the ASDEX upgrade (AUG) tokamak [A. Herrmann and O. Gruber, Fusion Sci. Technol. 44, 569 (2003)]. The detector resolves in time the energy and pitch angle of fast-ion losses induced by magnetohydrodynamics (MHD) fluctuations. The use of a novel scintillator material with a very short decay time and high quantum efficiency allows to identify the MHD fluctuations responsible for the ion losses through Fourier analysis. A Faraday cup (secondary scintillator plate) has been embedded behind the scintillator plate for an absolute calibration of the detector. The detector is mounted on a manipulator to vary its radial position with respect to the plasma. A thermocouple on the inner side of the graphite protection enables the safety search for the most adequate radial position. To align the scintillator light pattern with the light detectors a system composed by a lens and a vacuum-compatible halogen lamp has been allocated within the detector head. In this paper, the design of the scintillator probe, as well as the new technique used to analyze the data through spectrograms will be described. A last section is devoted to discuss the diagnosis prospects of this method for ITER [M. Shimada et al., Nucl. Fusion 47, S1 (2007)].

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The status of the AGILE GRB observations and the noticeable case of GRB 080514B

Since Summer 2007, the AGILE mission is successfully detecting and localizing Gamma Ray Bursts by using its wide-field hard X-ray monitor SuperAGILE (17-60 keV) and its CsI Minicalorimeter (0.3-20 MeV). Moreover, all the events with a known localization in the field of view of the Gamma Ray Imaging Detector are searched for in the 30 MeV-50 GeV energy range. Among the several bursts occurred in the field of view of the Gamma Ray Imaging Detector during more than one year of operations, at the time of writing the remarkable GRB 080514B is detected at high significance and GRB 080721 and GRB 081001 are detected at low significance. GRB 080514B is the first Gamma Ray Burst showing a significant emission above 20 MeV after EGRET, and the first ever associated with an afterglow, measured at X-rays and in the IR/Optical/UV. Significant upper limits are derived for the other GRBs. In this paper we report about the status and the scientific performances of the AGILE instrumentation in the study of GRBs and we discuss the properties of GRB 080514B in the context of the long Gamma Ray Bursts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗