Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Risk analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

A 3S Risk Assessment Approach for Nuclear Power: Safety, Security, and Safeguards

Safety-focused risk analysis and assessment approaches struggle to adequately include malicious, deliberate acts against the nuclear power industry's fissile and waste material, infrastructure, and facilities. Further, existing methods do not adequately address non- proliferation issues. Treating safety, security, and safeguards concerns independently is inefficient because, at best, it may not take explicit advantage of measures that provide benefits against multiple risk domains, and, at worst, it may lead to implementations that increase overall risk due to incompatibilities. What is needed is an integrated safety, security and safeguards risk (or "3SR") framework for describing and assessing nuclear power risks that can enable direct trade-offs and interactions in order to inform risk management processes — a potential paradigm shift in risk analysis and management. These proceedings of the Sandia ePRA Workshop (held August 22-23, 2017) are an attempt to begin the discussions and deliberations to extend and augment safety focused risk assessment approaches to include security concerns and begin moving towards a 3S Risk approach. Safeguards concerns were not included in this initial workshop and are left to future efforts.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Risk-Informed Analysis of Accidents at Reactor Facilities with VVER

An accident with ‘rupture of steam line’ as the initial event was studied for a reactor facility with VVER-1000. A computational analysis was performed of different flow scenarios of an accident with singular and multiple failures of the safety systems. The realization probability and the consequences were evaluated for each accident sequence. The consequences of the accidents are ranked and the most instructive combinations of failures of systems and blockings are determined from the standpoint of risk. The presented method is based on multivariate calculations and an integrated combination of deterministic and probabilistic approaches to safety validation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Considering Risk and Resilience in Decision-Making

This paper examines the concepts of decision-making, risk analysis, uncertainty and resilience analysis. The relation between risk, vulnerability, and resilience is analyzed. The paper describes how complexity, uncertainty, and ambiguity are the most critical factors in the definition of the approach and criteria for decision-making. Uncertainty in its various forms is what limits our ability to offer definitive answers to questions about the outcomes of alternatives in a decision-making process. It is shown that, although resilience-informed decision-making would seem fundamentally different from risk-informed decision-making, this is not the case as resilience-analysis can be easily incorporated within existing analytic-deliberative decision-making frameworks.

Torres-Pomales, Wilfredo↗

Capability for Integrated Systems Risk-Reduction Analysis

NASA's Human Research Program (HRP) is working to increase the likelihoods of human health and performance success during long-duration missions, and subsequent crew long-term health. To achieve these goals, there is a need to develop an integrated understanding of how the complex human physiological-socio-technical mission system behaves in spaceflight. This understanding will allow HRP to provide cross-disciplinary spaceflight countermeasures while minimizing resources such as mass, power, and volume. This understanding will also allow development of tools to assess the state of and enhance the resilience of individual crewmembers, teams, and the integrated mission system. We will discuss a set of risk-reduction questions that has been identified to guide the systems approach necessary to meet these needs. In addition, a framework of factors influencing human health and performance in space, called the Contributing Factor Map (CFM), is being applied as the backbone for incorporating information addressing these questions from sources throughout HRP. Using the common language of the CFM, information from sources such as the Human System Risk Board summaries, Integrated Research Plan, and HRP-funded publications has been combined and visualized in ways that allow insight into cross-disciplinary interconnections in a systematic, standardized fashion. We will show examples of these visualizations. We will also discuss applications of the resulting analysis capability that can inform science portfolio decisions, such as areas in which cross-disciplinary solicitations or countermeasure development will potentially be fruitful.

Mindock, J.↗

Pelvic Insufficiency Fracture After Pelvic Radiotherapy for Cervical Cancer: Analysis of Risk Factors

Purpose: To investigate the incidence, clinical characteristics, and risk factors of pelvic insufficiency fracture (PIF) after pelvic radiotherapy (RT) in cervical cancer. Methods and Materials: Medical records and imaging studies, including bone scintigraphy, CT, and MRI of 557 patients with cervical cancer who received whole-pelvic RT between January 1998 and August 2005 were reviewed. Results: Eighty-three patients were diagnosed as having PIF after pelvic RT. The 5-year cumulative incidence of PIF was 19.7%. The most commonly involved site was the sacroiliac joint. Pelvic pain developed in 48 patients (57.8%) at diagnosis. Eleven patients (13.3%) needed admission or narcotics because of severe pain, and others had good relief of symptoms with conservative management. In univariate analysis, age {>=}55 years (p < 0.001), anteroposterior/posteroanterior parallel opposing technique (p = 0.001), curative treatment (p < 0.001), and radiation dose {>=}50.4 Gy (p = 0.005) were the predisposing factors for development of PIF. Concurrent chemotherapy (p = 0.78) was not significant. Multivariate analysis showed that age {>=}55 years (p < 0.001), body weight <55 kg (p = 0.02), curative treatment (p = 0.03), and radiation dose {>=}50.4 Gy (p = 0.04) were significant predisposing factors for development of PIF. Conclusion: The development of PIF is not rare after pelvic RT. The use of multibeam arrangements to reduce the volume and dose of irradiated pelvic bone can be helpful to minimize the risk of fracture, especially in elderly women with low body weight.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Statistical Analysis of Risk Factors in the Prebreathe Reduction Protocol

The 165 exposures from four 2-hour protocols were analyzed for correlations or trends between decompression sickness (DCS) or venous gas emboli (VGE), and variables that affect risk in the subject and astronaut populations. The assumption in this global survey is that the distributions of gender, age, body mass index, etc., are equally represented in all four tested procedures. We used Student t-test for comparisons between means and chi-square test between comparisons of proportions with p<0.05 defining a significant level. The type and distribution of the 19 cases of DCS were similar to historical cases. There was no correlation of age, gender, body mass index or fitness level with greater incidence of DCS or VGE. However increased age was associated with more Grade IV VGE in males. The duration and quantity of exercise during prebreathe is inversely related to risk of DCS and VGE. The latency time for VGE was longer (103 min +/- 56 SD, n = 15) when the ergometry was done approximately 15 min into the prebreathe than when done at the start of the prebreathe (53 min +/- 31, n = 13). The order of the ergometry did not influence the overall DCS and VGE incidence. We identified variables other than those of the prebreathe procedures that influence the DCS and VGE outcome. The analysis suggests that males over 40 years have a high incidence of Grade IV VGE.

Gerth, Wayne A.↗

Wallops Ship Surveillance System

Approved as a Wallops control center backup system, the Wallops Ship Surveillance Software is a day-of-launch risk analysis tool for spaceport activities. The system calculates impact probabilities and displays ship locations relative to boundary lines. It enables rapid analysis of possible flight paths to preclude the need to cancel launches and allow execution of launches in a timely manner. Its design is based on low-cost, large-customer- base elements including personal computers, the Windows operating system, C/C++ object-oriented software, and network interfaces. In conformance with the NASA software safety standard, the system is designed to ensure that it does not falsely report a safe-for-launch condition. To improve the current ship surveillance method, the system is designed to prevent delay of launch under a safe-for-launch condition. A single workstation is designated the controller of the official ship information and the official risk analysis. Copies of this information are shared with other networked workstations. The program design is divided into five subsystems areas: 1. Communication Link -- threads that control the networking of workstations; 2. Contact List -- a thread that controls a list of protected item (ocean vessel) information; 3. Hazard List -- threads that control a list of hazardous item (debris) information and associated risk calculation information; 4. Display -- threads that control operator inputs and screen display outputs; and 5. Archive -- a thread that controls archive file read and write access. Currently, most of the hazard list thread and parts of other threads are being reused as part of a new ship surveillance system, under the SureTrak project.

Smith, Donna C.↗

Longitudinal analysis of risk factors for dementia based on Mild Cognitive Impairment Screen results and questionnaire responses from healthy Japanese individuals registered in an online database

Abstract Introduction Despite an urgent need for developing remedial measures against dementia, no disease‐modifying drugs have been developed. Efficient protocols for participant recruitment need to be established for conducting clinical trials. To meet this need, a large‐scale online registry system, the Integrated Registry of Orange Plan (IROOP ® ), was created for healthy individuals. Although the risk factors for dementia have been discussed in our previous studies for a short interval of 6 months, some factors remain controversial. The present study aimed to explore factors affecting longitudinal changes in cognitive function for a longer interval of 18 months using the IROOP ® data. Methods This study assessed the longitudinal changes in the collated data for predicting the risk of dementia and included 473 individuals (175 men and 298 women; mean age 59.6 ± 10.1 years) registered in the IROOP ® between July 5, 2016 and January 15, 2018 who completed the initial questionnaire and brief assessment of cognitive function (Mild Cognitive Impairment Screen) at baseline and the regular questionnaire and the Mild Cognitive Impairment Screen at least once after baseline. Statistical analyses were performed using IBM SPSS, version 23.0, for Windows for demographic data and the MIXED procedure in SAS, version 9.4, for the linear mixed‐effect model. In each analysis, the statistical significance level was set at P < .05. Results Mood, sleep, quality of life, and medical histories including cognition were found to influence longitudinal changes in cognitive function. Discussion Given the multifactorial etiology of dementia, preventive measures targeting multiple domains are required for maintaining cognitive function, instead of focusing on one lifestyle factor.

Ogawa, Masayo↗

Bioaccumulation of Cr, Ni, Cd and Pb in the Economically Important Freshwater Fish Schizothorax plagiostomus from Three Rivers of Malakand Division, Pakistan: Risk Assessment for Human Health

Contamination of freshwater ecosystems such as rivers with hazardous heavy metals is an environmental problem of public health concern. Accumulation of potentially toxic heavy metals in freshwater fish causes a potential health threat to their consumers including humans. The present research aimed to (1) investigate the accumulation of four potentially toxic heavy metals viz. Cr, Ni, Cd and Pb in muscle tissue of the commercially important freshwater fish Schizothorax plagiostomus at different sites of River Swat, River Panjkora and River Barandu in northern Pakistan (2) to compare gross metal accumulation in the fish samples by calculating metal pollution index (MPI) and (3) to assess potential risk to the health of the fish consumers. Samples were analyzed for the heavy metals by flame atomic absorption spectrophotometry (FAAS). Risk analysis showed that Ni risk was higher at River Panjkora and River Barandu, Pb risk was higher at River Swat and River Panjkora while Cd risk was quite low at all the three rivers.

54 ENVIRONMENTAL SCIENCES↗

Demonstration of the Advanced Dynamic System Modeling Tool TRANSFORM in a Molten Salt Reactor Application via a Model of the Molten Salt Demonstration Reactor

Liquid-fueled nuclear reactors, particularly molten salt reactors (MSRs), have recently gained significant interest in the advanced reactor community. As with all reactors, modeling and simulation are critical to advanced reactor design and licensing and will be required for MSR deployment. However, there are significant gaps in existing simulation capabilities for MSRs, particularly with the unique challenges of liquid-fueled systems (e.g., fission product transport). Furthermore, advanced reactor designers require near-term tools that are readily modifiable to perform design and analysis, including the ability to extend their analysis beyond the primary system to auxiliary systems. Transient Simulation Framework of Reconfigurable Models (TRANSFORM), a Modelica-based, system modeling library developed at Oak Ridge National Laboratory, is an advanced tool that can help meet some of the near-term needs of the advanced reactor community. Here, this paper describes advanced system modeling criteria and presents TRANSFORM to the advanced reactor community by demonstration of system modeling capabilities and support of advanced analysis workflows, i.e., the Risk Analysis Virtual Environment (RAVEN) framework from Idaho National Laboratory, using the liquid-fueled Molten Salt Demonstration Reactor (MSDR) as a reference design.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A SCOPING STUDY: Development of Probabilistic Risk Assessment Models for Reactivity Insertion Accidents During Shutdown In U.S. Commercial Light Water Reactors

This report documents the scoping study of developing generic simplified fuel damage risk models for quantitative analysis from inadvertent reactivity insertion events during shutdown (SD) in light water pressurized and boiling water reactors. In the past, nuclear fuel reactivity accidents have been analyzed both mainly deterministically and probabilistically for at-power and SD operations of nuclear power plants (NPPs). Since then, many NPPs had power up-rates and longer refueling intervals, which resulted in fuel configurations that may potentially respond differently (in an undesirable way) to reactivity accidents. Also, as shown in a recent event, several inadvertent operator actions caused potential nuclear fuel reactivity insertion accident during SD operations. The set inadvertent operator actions are likely to be plant- and operation-state specific and could lead to accident sequences. This study is an outcome of the concern which arose after the inadvertent withdrawal of control rods at Dresden Unit 3 in 2008 due to operator actions in the plant inadvertently three control rods were withdrawn from the reactor without knowledge of the main control room operator. The purpose of this Standardized Plant Analysis Risk (SPAR) Model development project is to develop simplified SPAR Models that can be used by staff analysts to perform risk analyses of operating events and/or conditions occurring during SD operation. These types of accident scenarios are dominated by the operator actions, (e.g., misalignment of valves, failure to follow procedures and errors of commissions). Human error probabilities specific to this model were assessed using the methodology developed for SPAR model human error evaluations. The event trees, fault trees, basic event data and data sources for the model are provided in the report. The end state is defined as the reactor becomes critical. The scoping study includes a brief literature search/review of historical events, developments of a small set of comprehensive event trees and fault trees and recommendation for future work.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of Risks to Oxygen Systems from Particulate and Fiber Contaminants and Derivation of Cleanliness Requirements

It has been well documented in the literature that contamination within oxygen systems can create significant fire hazards. Cleanliness limits for nonvolatile residues, ranging from 10 to 500 mg/sq m, have been established for various industries and types of oxygen systems to reduce the risk of ignition of flammable organic films. Particulate cleanliness limits used for oxygen systems vary considerably. Maximum allowed particle size, quantity limits, and allocations for fibers or metallic particles are all variables seen in aerospace cleanliness limits. Particles are known to have the potential to ignite within oxygen systems and must be limited to prevent fires. Particulate contamination may also pose risks to the performance of oxygen systems that are unrelated to ignition hazards. An extensive literature search was performed to better understand the relative importance of particle ignition mechanisms versus other deleterious effects of particles on oxygen systems and to identify rationale for derivation of particulate cleanliness limits for specific systems. The identified risks of different types and sizes of particles and fibers were analyzed. This paper summarizes the risks identified and rationale that may be used to derive particulate cleanliness limits for specific oxygen systems.

Lowrey, Nikki M.↗

Analysis of Risks to Oxygen Systems from Particulate and Fiber Contaminants and Derivation of Cleanliness Requirements

It has been well documented in the literature that contamination within oxygen systems can create significant fire hazards. Cleanliness limits for nonvolatile residues, ranging from 10 to 500 milligrams per square meter, have been established for various industries and types of oxygen systems to reduce the risk of ignition of flammable organic films. Particulate cleanliness limits used for oxygen systems, however, vary considerably, notably within the aerospace industry. Maximum allowed particle size, quantity limits, and allocations for fibers or metallic particles are all variables seen in aerospace cleanliness limits. Particles are known to have the potential to ignite within oxygen systems and must be limited to prevent fires. Particulate contamination may also pose risks to the performance of oxygen systems that are unrelated to ignition hazards. An extensive literature search was performed to better understand the relative importance of particle ignition mechanisms versus other deleterious effects of particles on oxygen systems and to identify rationale for derivation of particulate cleanliness limits for specific systems. The identified risks of different types and sizes of particles and fibers were analyzed. This paper summarizes the risks identified and rationale that may be used to derive particulate cleanliness limits for specific oxygen systems.

Lowrey, Nikki M.↗