Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Resource Assessments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Managing Solar Photovoltaic Integration in the Western United States: Resource Adequacy Considerations

This study examines the impact of reserve margin-based reliability assessment, as commonly used in capacity expansion models, on planning resource-adequate power systems under high penetrations of solar photovoltaics (PV). As a generation resource, PV is operationally different from the conventional dispatchable resources for which most capacity expansion models were designed. The question this study attempts to answer is whether large amounts of PV on a system (in this case, the Western Interconnection of North America) would bias the results of conventional reserve margin-based capacity expansion modeling towards an over- or under-provisioning of resource adequacy. This analysis used NREL’s Resource Planning Model (RPM) for capacity expansion modeling and NREL’s Probabilistic Resource Adequacy Suite (PRAS) for resource adequacy assessment. RPM uses a reserve margin requirement to enforce resource adequacy. PRAS, a collection of tools for studying the resource adequacy of power systems and the adequacy contributions of individual resources on a probabilistic basis, was used to compute multiple resource adequacy metrics across a number of simulated scenarios and system representations with differing regional detail. In all cases, including high PV penetrations (up to 33% annual generation from PV, interconnection-wide), RPM was able to produce resource-adequate systems as measured by normalized expected unserved energy and loss-of-load expectation results from PRAS. The accuracy of reserve margin approaches depends heavily on the underlying assumptions informing the capacity credit assigned to variable and energy-limited resources, particularly when such resources are abundant in the modeled system. RPM’s standard methodology for estimating variable and flexible resources’ capacity contributions, which is based on the top 100 hours of net load, did not appear to systematically undervalue or overvalue variable generation relative to a more rigorous equivalent firm capacity assessment using PRAS, although both over- and under-valuations were observed in specific scenarios. In the worst cases, the top 100 hour method underestimated the equivalent firm capacity of PV by two percentage points, and overestimated the equivalent firm capacity of PV by five percentage points. Calculating capacity contributions based on the top 10 hours of net load systematically underestimated equivalent firm capacities at more modest PV penetrations, but was often a better approximation of equivalent firm capacity than the existing 100-hour approach in scenarios with higher PV penetrations.

14 SOLAR ENERGY↗

Data-driven offshore CO 2 saline storage assessment methodology

The world produces approximately 50 billion tonnes of greenhouse gases annually. This is measured in CO 2 -equivalents, and geologic CO 2 storage has the potential to advance decarbonization and mitigate greenhouse gas emissions. New technologies to assess offshore carbon storage are needed to address resource, regulatory, and commercial needs. Although most efforts to assess storage resources focus on onshore criteria, offshore reservoirs offer significant storage potential and distinct development challenges. Potential advantages of offshore carbon storage include being further from human population centers and less potential to interact with groundwater. The U.S. Department of Energy's method for evaluating storage capacity in non-oil-bearing saline reservoirs has been enhanced to support assessments for offshore environments in the Offshore CO 2 Saline Storage methodology (OCSS). This methodology applies data-driven capabilities to estimate saline storage capacity while accounting for features specific to offshore reservoirs. Features include changes in CO 2 density and sedimentary differences that impact estimates of permanence and capacity. The Offshore CO 2 Saline Storage Calculator mechanizes OCSS to estimate storage capacity. This paper presents the methodology and estimates for 18 geologic domains in the Gulf of Mexico. Potential storage distributions, sensitivity analyses, and the incorporation of spatial data and tools to support safe site selection are also discussed.

58 GEOSCIENCES↗

Task 12 PV Sustainability - Environmental Life Cycle Assessment of Residential PV and Battery Storage Systems

Using a life cycle assessment (LCA), the environmental impacts from generating 1 kWh of electricity for self-consumption via a photovoltaic-battery system are determined. The system includes a 10 kWp multicrystalline-silicon photovoltaic (PV) system (solar irradiation about 1350 kWh/m2/year and annual yield 1000 kWh/kWp), an iron phosphate lithium-ion (LiFePO4) battery, and other components such as the control system, battery housing, and two inverters (one for the PV system and one for the battery system). Three options for the AC-coupled system with changing battery capacities (5, 10, or 20 kWh nominal capacity) are investigated. The environmental impacts are assessed using the indicators greenhouse gas emissions and cumulative energy demand (separated into total and non-renewable cumulative energy demand). In addition, the four most important impact categories for PV electricity - respiratory inorganics (particulate matter), acidification, energy carrier resource use, and minerals and metals resource use - are assessed according to the environmental footprint (EF) method. Data are drawn from the DETEC data DQRv2:2018, recent literature, and product details provided by manufacturers. The results show larger environmental impacts of PV-battery systems with increasing battery capacity; for capacities of 5, 10, and 20 kWh, the cumulative greenhouse gas emissions from 1 kWh of electricity generation for self-consumption via a PV-battery system are 80, 84, and 88 g CO 2- eq/kWh, respectively. The cumulative greenhouse gas emissions of PV electricity consumed directly or fed into the grid are 54 g CO 2 -eq/kWh. The corresponding total cumulative energy demands are 5.27, 5.40, and 5.50 MJ oil-eq/kWh, with non-renewable energy carriers contributing 1.16, 1.22, and 1.29 MJ oil-eq/kWh. In the investigated EF impact categories, we similarly observe a larger environmental burden with increasing battery capacity, except in the use of minerals and metals. Our sensitivity analyses show that using a nickel cobalt manganese oxide (NCM) lithium-ion battery, instead of an LiFePO 4 battery, leads to a comparable environmental impact in terms of greenhouse gas emissions and cumulative energy demand. However, the NCM battery increases the impact in the EF categories of acidification and respiratory inorganics by 7 and 10%, respectively, whereas energy carrier resource use decreases by 4% and minerals and metals resource use decrease by 1%. Using a copper indium selenium (CIS) PV panel instead of a multicrystalline-silicon decreases greenhouse gas emissions by 24%, non-renewable cumulative energy demand by 13%, and particulate matter emissions by 60% (the largest decrease). Furthermore, the calculated environmental impacts are sensitive to the assumed battery lifetime. A decrease from 5000 to 3000 charge cycles increases non-renewable cumulative energy demand by 24% and greenhouse gas emissions by 16%. Increasing from 5000 to 7000 charge cycles decreases the environmental impacts by 6% and 7% in terms of non-renewable cumulative energy demand and greenhouse gas emissions, respectively. A utility-scale battery system case study shows that using batteries to store PV electricity overproduction reduces greenhouse gas emissions compared to using natural gas backup electricity generation.

14 SOLAR ENERGY↗

Pala Energy Options Analysis (Final Report)

The Pala Energy Options Project scope focused on assessing electric and thermal energy related options for the Pala Band of Mission Indians. Although the assessment also considered options for transportation fuels – including potential for electrification – and other energy uses, initial reviews with PED staff indicated that the most practical and substantial options likely would involve serving current building electric and thermal energy resources and uses. Assessment scope varies by specific options considered; some merited in-depth assessment for immediate action to initiate or advance implementation, while higher level assessments were more appropriate for options that would take longer to implement and would require updated in-depth assessments during project planning and design phases. The primary objectives of the Project were to 1) identify energy resources/loads, 2) assess energy needs and exports, 3) investigate and evaluate supply-side and demand side energy options, and 4) select and prioritize options in an implementation plan.

14 SOLAR ENERGY↗

Data for Post-Access Report: Tidal Energy Resource Characterization and Model Validation via the Assessment of Cost-effective Spatially Distributed Current Measurements from microFloat Swarms

This project evaluated how high-resolution, spatially distributed field data can be used to refine and validate site-scale hydrodynamic simulations of tidal channels. Use of such spatially-distributed field observations or site-scale hydrodynamic simulations will be needed for producing accurate predictions of tidal energy production over larger arrays of tidal turbines. The data contained in this archive includes field observations of water velocity from a series of short surveys in Agate Pass taken on August 20th, 2020 using station-keeping ADCP (acoustic doppler current profiler) measurements, drifting downward-looking ADCPs, and microFloats, gathered by researchers at APL-UW under a previous project. It also includes high-resolution hydrodynamic model runs for the site during that time generated under TEAMER support. An explanatory file (.pdf format) describes the survey and field data structure. Processed data is stored in .mat format. Survey summary: start time, number of floats, water level. microFloat data: - Cleaned data for each float in survey, - Time series of position (lat., lon.), depth (relative to surface), and horizontal velocity (u, v) Drifting ADCP data: - Cleaned data for each drifting ADCP in survey - Time series of position (lat., lon.), sample depth (relative to surface), and observed water velocity (u,v,w) Stationary ADCP data: - Cleaned data for each station-keeping data set in survey - Time series of position (lat., lon.), sample depth (relative to surface), and observed water velocity (u,v,w) FVCOM (Finite Volume Coastal Ocean Model) model outputs: Water level and velocity, as well as derived variables (e.g., power density) from the final refined model simulations for the Agate Pass subdomain. Contained in NetCDF and ASCII files for the duration of August 18th and 20th 2020 field surveys. Additional scripts for processing the data and generating the figures in the report are included.

16 TIDAL AND WAVE POWER↗

Geothermal Play-Fairway Analysis of Washington State Prospects: Final Report

The Washington State Geothermal Play-Fairway Analysis overcomes the exploration challenges posed by dense vegetation, glacial deposits, and extreme precipitation. The geothermal play-fairways we target are locations where heat, permeability, and saturated porosity are present in sufficient volume to provide adequate heat exchange at depths accessible by modern drilling technology. The three study areas lie along the Cascade Range magmatic arc and are near Mount Baker, Mount St. Helens, and the Wind River Valley. The seven-year project is divided into three phases. In Phase 1 we build on a previous statewide assessment of geothermal resources and develop an initial modeling approach. The results are a series of favorability, uncertainty, and risk maps for three targeted study areas. Based on these initial results, we collect new geologic and geophysical data to further refine our modeling and reduce exploration uncertainty in Phase 2. We improve the modeling method to handle the new data and update the favorability, uncertainty, and risk maps. We also update the conceptual geothermal resource models. In Phase 3 we validate our modeling approach by drilling two temperature-gradient holes and collecting and analyzing core, image logs, and new geochemistry. Our modeling approach improves on an earlier statewide method through a more-rigorous and detailed assessment of heat and permeability. Permeability potential is assessed through geomechanical modeling of the deformation that can generate and maintain reservoir porosity and permeability. Metrics to inform heat potential include temperature-gradient wells, which are sparse in Washington; proximity of Quaternary volcanic vents and young intrusive rock; spring temperature; and reservoir temperature inferred from geothermometry. We weight the individual components using an expert-guided approach known as the Analytical Hierarchy Process. During Phase 2 we also develop a fluid-filled fracture model, and an infrastructure model that helps to delineate areas which are more favorable for geothermal development based on proximity to transmission lines, elevation, land ownership and use restrictions, and availability of process water. New geologic and geophysical data is collected during Phase 2 in each of our three main study areas. At Mount Baker and north of Mount St. Helens we conduct 1:24,000-scale geologic mapping and lidar analysis to better constrain the location and character of surface faults; detailed mapping in the Wind River Valley was completed just prior to the start of this project. Ages of intrusive rocks are determined with 40 Ar/ 39 Ar geochronology, though all of our samples are Miocene or older. We collect ground based gravity observations (a total of 1,580 new stations) in all of our study areas and ground-based magnetic lines (a total of 93 km) at Mount Baker. These data are combined with existing gravity and aeromagnetic data and used to constrain fault locations and geometry. Two to three cross sections are constructed at each study area using the mapped surface geology and forward-modeling of the gravity and magnetic data; these cross sections form the basis for our updated conceptual models. We collect magnetotelluric surveys at Mount Baker and Mount St. Helens and these data are inverted to form a resistivity model from the surface to about 10 km depth; each model shows conductive zones that can be interpreted as upwelling geothermal fluids. At Mount St. Helens we deploy a passive seismic array and use the newly detected events to refine the location of the Saint Helens seismic zone. We also employ ambient-noise tomography to develop a detailed seismic-velocity model for the study area and use this model to help constrain our cross sections and conceptual model. Based on the new data collected during Phase 2—and our updated models—we develop a campaign of temperature-gradient holes and core analysis to validate our modeling in Phase 3. Drill hole MB76-31 is located near Little Park Creek, 11 km west-southwest of the summit of Mount Baker, and is 1,471 ft deep. About 410 ft of core from the lower portion of the hole—and image logs from ~175 ft below ground surface to the bottom—are collected and analyzed. Water samples are collected and processed for geothermometry. Drill hole MSH17-24 is located along upper Schultz Creek, 16 km north-northeast of Mount St. Helens and has core from 470 ft to the bottom at 1,053 ft. We did not collect image logs due to borehole stability concerns, but water samples are collected and analyzed for geothermometry. Repeat temperature-gradient measurements are made at both sites and thermal conductivity is measured from core samples. At MB76-31, the equilibrated temperature gradient of 64°C/km and calculated heat flow of 141–159 mW/m 2 is more than twice the regional average. Detailed mapping and analysis of the core, coupled with correlation to the image logs, indicates a history of permeability generation consistent with our predictions of high permeability. Because the site has high favorability in the Phase 2 model, we consider the results a positive validation of the modeling. At site MSH17-24, the equilibrated temperature gradient of ~15°C/km and calculated heat flow of 41–43 mW/m 2 are similar to regional. Geochemical analysis of the water samples indicates a meteoric source without any geothermal component. Detailed outcrop-based mapping of fault exposures near the drill site and analysis of image logs from nearby boreholes indicates a history of permeability generation consistent with our predictions. Because the site has low favorability in the Phase 2 model, we consider the results a positive validation of the modeling. Together, the two sites provide a reasonably positive validation of the Phase 2 modeling and should encourage future use of this modeling approach.

15 GEOTHERMAL ENERGY↗

Combined Structural Analysis of Core and Image Log of TGH 76-31 South East of Mt Baker, Washington State

Despite active volcanism, few geothermal energy resources have been developed in the Cascades Range. Temperature Gradient Hole 76-31 was drilled to ~440 m measured depth to probe for zones where fractures provide fluid conduits that transport deep volcanic heat to shallow depths that could support baseload, carbon neutral electrical generation. These zones were predicted by a Play Fairway assessment (PFA) of resource potential along a zone 11 km west-southwest of the summit of Mount Baker Volcano. Rock core, temperature logs, and an acoustic image log were obtained. By comparison to outcrops, the core has been initially interpreted as the Chilliwack group comprised of partially metamorphosed basaltic to andesitic volcanics. Core mapping reveals complex, steeply dipping networks of fractures and brecciation along slickensided strike slip faults; clay alteration is common in many of these structures. The majority of fractures are thoroughly healed by layers of chlorite and calcite; preservation of pyrite indicates anoxic conditions. The majority of fracture porosity resides in very dense fractures a few centimeters or less in length. The image log provides good insights into attitude of fractures that fully transect the core, but generally underestimates fracture density. The combination of complex, non-planar fracture zones containing many short fractures and healing promote misinterpretation of natural fracture attitude and density in the image log. The healing and anoxic minerals are consistent with the conductive temperature gradient measured in the well below a shallow isothermal zone, although, several fractures are open or only partially healed and resulted in fluid entries into the well. Here, the equilibrated measured temperature gradient of 64ºC/km and calculated heat flow of 145 mW/m2 is more than twice the regional average, indicating local influence of the Mt Baker magmatic system at the Little Park Creek TGH site.

Cascades↗

Carbon Storage Planning Framework Dashboard

The Carbon Storage Planning Framework dashboard (beta version) provides easy access to explore, query, and evaluate multiple data layers to support and accelerate carbon storage resource and feasibility assessments and planning efforts. The interactive dashboard currently contains a range of authoritative datasets associated with geologic, technical, social, and environmental factors. The data sets can be filtered geographically for an area of interest to update statistics and charts within the dashboard. Terms of Use: NETL is sharing this beta/prototype tool with the request that users will provide feedback to NETL about the function and content of the dashboard, alerting NETL to any bugs or providing suggestions for additional resources to help mature the platform.

CCS,EDX4CCS,carbon storage,dashboard↗

CARILEC Resilient Energy Community CoP for Cybersecurity Workshop Series: Cybersecurity Assessment Tools [Slides]

For the last several years and in collaboration with CARILEC, USAID and NREL have been working to support cyber resilience at power sector utilities in Latin America and the Caribbean. Direct technical assistance with regional utilities has been a key component of USAID-NREL Partnership activities, and technical assistance has typically included a foundational cybersecurity assessment using NREL's Distributed Energy Resource Cybersecurity Framework (DER-CF) tool. The DER-CF allows organizations to benchmark and evaluate their cybersecurity posture across the areas of Governance, Technical Management, and Physical Security. To complement the activities of the newly created CAREC IT/OT and Cybersecurity Team, this webinar on cybersecurity assessment tools includes an overview of the DER-CF tool and a discussion with regional stakeholders and NREL experts on the DER-CF assessment process and other resources for cybersecurity assessments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Classified library critical in Lab’s Annual Assessment of weapons to U.S. President. National Security Resource Center’s collections are the foundation to stockpile confidence

One of the most important accomplishments every year at LANL is a letter sent by the Laboratory Director that ultimately reaches the President of the United States. The subject is the current state of the weapons for which the Lab is responsible. Known as the Annual Assessment letter, it is a culmination of nearly 14 months’ worth of work and the contributions of more than 1,000 Lab staff members. Its classified contents come from the Lab’s Annual Assessment, which is an approximately 100-page document evaluating the safety, security and effectiveness of the stockpile.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The National Climate Data Base (NCDB): A Bias-Corrected High-Resolution Climate Dataset

Assessing renewable energy resources under future climate scenarios has been highlighted in recent years to analyze and understand potential impacts of future change in renewable generation on the power sector. Solar energy is well-known as the most plentiful among various renewable resources and usually converted to electricity using photovoltaics (PV) technologies, and the global deployment of PV technology has increased rapidly in recent decades. In this study, we develop a statistical technique to downscale the future projection of solar irradiance for PV energy-related applications. A set of Regional Climate Model (RCM)-based projections obtained from the North American Coordinated Regional Climate Downscaling Experiment (NA-CORDEX) are used as inputs to statistical methods to generate high-resolution global horizontal irradiance (GHI) over the contiguous United States (CONUS). The main steps of the statistical downscaling method include (1) regridding RCM output (0.22 degree and daily resolutions) to handle the modeled-observed data sets on a common grid, (2) correcting bias of RCM GHI using satellite-derived observation, and (3) implementing temporal and spatial downscaling to generate GHI at 8-km and hourly resolution. Basically, complex physical processes and interactions between solar radiation and various atmospheric constituents lead solar irradiance to be highly variable and uncertain. Underrepresentation of clouds from the RCM parameterizations is the main source of error and uncertainty in modeling solar irradiance. Thus, we adapt and use the high-quality satellite-derived data from the National Solar Radiation Database (NSRDB) to analyze the bias and error of RCM GHI as well as estimate the statistical parameters for spatial and temporal downscaling. This presentation will summarize the comprehensive analysis conducted to produce and assess the results under two climate scenarios (RCP4.5 and RCP8.5). We will also present a detailed validation demonstrating the strengths of the proposed downscaling method and future extension of this research.

climate data↗

Assessment of Climate Change Impacts on Renewable Energy Resources in Western North America

We examine a 25 km resolution climate model dataset to evaluate how regional climate change impacts solar and wind energy under a high-emission scenario. Our study considers the Western Electricity Coordinating Council (WECC) region, which covers the western United States and southwestern Canada, focusing specifically on locations with existing solar and wind infrastructure. First, we conduct a historical model comparison of solar and wind energy capacity factors to highlight model uncertainties across the study area. Using future climate projections, we then assess the seasonal patterns of solar and wind capacity factors for three timeframes: historical, mid-century, and end of century. Additionally, we estimate the frequency of solar and wind resource droughts during these periods for the entire WECC and its five operational subregions, finding that certain subregions are more susceptible to energy droughts due to limited renewable resources. Finally, we present day-ahead capacity factor forecasts to support energy storage planning and provide estimates of offshore wind energy capacity within the WECC. Our results indicate that offshore wind capacity factors are nearly twice as high as onshore values, with less seasonal variation, which suggests that offshore wind could offer a more consistent renewable energy supply in the future.

climate change↗

High-Resolution Wind Resource Data Set of the Greater Puerto Rico Region

In February 2022, the U.S. Department of Energy and six national laboratories launched the Puerto Rico Grid Resilience and Transitions to 100% Renewable Energy Study (PR100). PR100 aims to provide a comprehensive analysis of possible pathways for Puerto Rico's energy future, with a goal of 100% renewable energy by 2050. As a part of the renewable energy potential assessment in this project, we developed 20 years (2001-2020) of data using a numerical weather prediction (NWP) model for onshore and offshore wind resource assessment for the Puerto Rico. The research steps in developing the long-term wind resource data sets based on the NWP model were: 1. Model wind resource based on the Weather Research and Forecasting (WRF) model. 2. Develop WRF model configurations for Puerto Rico. 3. Test WRF with 11 different physics parameterizations for planetary boundary layer (PBL). 4. Assess WRF output from the different PBL schemes against observations. 5. Select a final model configuration which can produce the modeled wind speed with sufficient accuracy. 6. Produce 20 years wind resource data sets for Puerto Rico region. In the first stage of our framework for developing wind resource data, we developed a WRF model configuration using two nested domains (9 km and 3 km) to cover Puerto Rico and U.S. Virgin Islands and downscale the ERA5 reanalysis data (0.25 degrees x 0.25 degrees; hourly interval) to a 3-km domain. For the second stage, we implemented one-year simulations focused on using 11 different PBL physics parameterizations to find a combination of WRF physics parameterizations that could provide accurately modeled wind speed for Puerto Rico. We also analyzed the sensitivity of the modeled wind speed to PBL schemes for onshore and offshore locations. The WRF output resulting from the 11 WRF experiments using different PBL parameterizations were evaluated against observations obtained from the National Data Buoy Center (NDBC) as well as at hub height for a location for which measurements were available. A final model setup selected through the validation with observational data was used to produce 20 years of data with 3-km spatial and 5-minute temporal resolution. The WRF model output was post-processed to include wind profiles and basic atmospheric variables in a format that can be easily used for downstream modeling. The 20 years of wind resource data will be made available through NREL and support the estimation of wind energy development costs for the PR100 study.

17 WIND ENERGY↗

Impedance Scan of Inverter-Based Resources and Diesel Generator for Stability Analysis

Impedance-based methods are widely used for power system stability analysis with inverter-based resources (IBRs), e.g., assessing dynamic interactions between the power grid and an IBR, control interactions between multiple IBRs, and the sub-synchronous oscillation and damping phenomenon. Since it is difficult to get a numerical model 100% matching with the hardware IBR, using the hardware inverter directly to obtain its output impedance has become a prominent approach nowadays. Therefore, this article presents the impedance scan using hardware IBRs, and also a hardware diesel generator as it still stays with the grid before the grid completely goes to renewable. The devices under test (DuTs) for the impedance scan includes two 3-..phi.., 480 V, 60 Hz commercial grid-forming IBRs (one of 250 kVA and another of 125 kVA rating) in series with ..delta..-Y transformers, one 3-..phi.., 480 V, 60 Hz commercial grid-following IBR (of 125 kVA rating), and a 3-..phi.., 480 V, 60 Hz commercial diesel generator (of 187.5 kVA rating). Using voltage signals perturbed with sub-, inter-, and higher harmonic components, and measuring the current response, the positive-sequence impedances are computed via an offline-based post-analysis. Moreover, best-fit transfer functions are estimated that closely resemble the measured data points of the positive-sequence impedances. Based on the observations from various outcomes of the hardware experiments, this article also provides some fundamental insights on the equivalent positive-sequence impedance of a combination of multiple hardware components by comparing the estimated and the empirically computed impedances. A comparative insight on the damping capability of the DuTs using the positive-sequence impedances of the hardware is also discussed.

current measurement↗

Climate hazard indices projections based on CORDEX-CORE, CMIP5 and CMIP6 ensemble

The CORDEX-CORE initiative was developed with the aim of producing homogeneous regional climate model (RCM) projections over domains world wide. In its first phase, two RCMs were run at 0.22° resolution downscaling 3 global climate models (GCMs) from the CMIP5 program for 9 CORDEX domains and two climate scenarios, the RCP2.6 and RCP8.5. The CORDEX-CORE simulations along with the CMIP5 GCM ensemble and the most recently produced CMIP6 GCM ensemble are analyzed, with focus on several temperature, heat, wet and dry hazard indicators for present day and mid-century and far future time slices. The CORDEX-CORE ensemble shows a better performance than the driving GCMs for several hazard indices due to its higher spatial resolution. For the far future time slice the 3 ensembles project an increase in all temperature and heat indices analyzed under the RCP8.5 scenario. The largest increases are always shown by the CMIP6 ensemble, except for Tx > 35 °C, for which the CORDEX-CORE projects higher warming. Extreme wet and flood prone maxima are projected to increase by the RCM ensemble over the la Plata basin in South America, the Congo basin in Africa, east North America, north east Europe, India and Indochina, regions where a better performance is obtained, whereas the GCM ensembles show small or negligible signals. Furthermore, compound hazard hotspots based on heat, drought and wet indicators are detected in each continent worldwide in region like Central America, the Amazon, the Mediterranean, South Africa and Australia, where a linear relation is shown between the heatwave and drought change signal, and region like Arabian peninsula, the central and south east Africa region (SEAF), the north west America (NWN), south east Asia, India, China and central and northern European regions (WCE, NEU) where the same linear relation is found for extreme precipitation and HW increases. Although still limited, the CORDEX-CORE initiative was able to produce high resolution climate projections with almost global coverage and can provide an important resource for impact assessment and climate service activities.

54 ENVIRONMENTAL SCIENCES↗

Review: “Jacob’s Zoo”—how using Jacob’s method for aquifer testing leads to more intuitive understanding of aquifer characteristics

The interpretation of aquifer responses to pumping tests is an important tool for assessing aquifer geometry and properties, which are critical in the assessment of water resources or in environmental remediation. However, the responses of aquifers, measured by time-drawdown relationships in monitoring wells, are nonunique solutions that are affected by many factors. Jacob's Zoo is a collection of graphical interpretations that allows students and practitioners to develop an intuitive feel for how natural hydrogeological systems work, and develop a set of skills that provide a better understanding of aquifer properties much beyond interpretation of pumping tests. Jacob's Zoo, based on the work of Jacob (1950), fosters a deeper understanding, although few practitioners realize the full utility of the method. Jacob CE (1950) Flow of groundwater, In: Rouse H (ed) Engineering Hydraulics, Wiley, New York. P 321-386.

54 ENVIRONMENTAL SCIENCES↗

Modeling the impact of extreme summer drought on conventional and renewable generation capacity: Methods and a case study on the Eastern U.S. power system

Across recent years, there has been a growing prevalence of extreme weather events throughout the United States, posing significant challenges to the reliable and resilient operation of power systems. Specifically, summer droughts threaten to severely reduce available generation capacity to meet regional electricity demand, potentially leading to power outages. This underscores the importance of accurate resource adequacy (RA) assessment to ensure the reliable operation of the nation’s energy infrastructure. Accurately evaluating the usable capacity of regional generation fleets is a challenging undertaking due to the intricate interactions between power systems and hydro-climatic systems. Here, this paper proposes a systematic and analytical framework to evaluate the impacts of extreme summer drought events on the available capacity of various generating technologies, incorporating both meteorological and hydrologic factors. The framework provides detailed plant-level capacity derating models for hydroelectric, thermoelectric, and renewable power plants, facilitating evaluations with high temporal and spatial resolution. The application of the proposed impact assessment framework to the 2025 generation fleet of the real-world power system within the PJM and SERC regions of the United States yields insightful results. By analyzing the daily usable capacity of 6,055 at-risk generators across the study region, it shows that the summer capacity deration is most significant for hydroelectric and once-through thermal power plants, followed by recirculating thermal power plants and combustion turbines. In the event of the recurrence of the 2007 southeastern summer drought event in the near future, the generation fleet could experience a substantial reduction in available capacity, estimated at approximately 8.5 GW, compared to typical summer conditions. The sensitivity analysis reveals that the usable capacity of the generation fleet would suffer an even more significant decrease under conditions of increasingly severe summer droughts. The proposed approach and the findings of this study provide valuable methodologies and insights, empowering stakeholders to bolster the resilience of power systems against the potentially devastating effects of future extreme drought events.

24 POWER TRANSMISSION AND DISTRIBUTION↗