Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Residential Building Energy Use”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Energy flexibility of residential buildings: A systematic review of characterization and quantification methods and applications

With building electric demand becoming increasingly dynamic, and a growing percentage of intermittent renewable power generation from solar photovoltaics and wind turbines, the power grid is facing increasing challenge to manage the real time balance between the supply and demand. With advancements in smart sensing and metering, smart appliances, electric vehicles, and energy storage technologies, demand side management of residential buildings can help the grid to improve stability by optimizing flexible loads. This paper reviews recent studies on residential building demand side management, with a focus on characterization and quantification of energy flexibility covering various types of flexible loads, metrics, methods, and applications. The reviewed studies showed four levels of applications: building level (45%), district or community level (29%), system level (19%), and building sector level (7%). Shifting loads is the dominant flexibility type in 60% of applications, followed by shedding (19%), generation (16%), and modulating (6%). Depending on the technology and application scope, flexible operations have a wide range of performance, with peak power reductions of 1%~65%, energy savings up to 60%, operational cost reduction of 1%~48%, and greenhouse gas emission reductions of up to29%. More than half (51%) of the studies employed control strategies to achieve flexibility; among those 72% used optimal controls, while 28% used rule-based controls. About 58% of the studies used mathematical formulation to quantify energy flexibility. Most studies were based on simulation, while less than 15% of the studies had measurements from experiments or field tests. The review reveals research opportunities to address significant gaps in the existing literature: (1) establishing a common definition and performance metrics for energy flexibility of buildings that are technology and application agnostic, (2) developing an ontology to standardize representation of flexibility resources for interoperability, (3) integrating occupant impacts into the quantification and optimization of energy flexibility, and (4) developing requirements and credits of energy flexibility in building energy codes and standards. Findings from the review can inform future research and development of energy flexible buildings which are essential to a reliable and resilient power grid.

Li, H↗

Becoming a 10: A Closer Look at the U.S. Department of Energy Home Energy Score's Updates, Improvements, and Expansion

The U.S. Department of Energy (DOE)'s Home Energy Score provides homeowners, buyers, and renters directly comparable and credible information about a home's estimated energy use and costs. Certified Qualified Assessors conduct low-cost assessments to provide each home a 1-10 score alongside a set of cost-effective upgrades to improve the score. As of February 2022, hundreds of assessors have delivered over 175,000 scores to homes across the country. Originally released in 2012 using DOE2.1e as the modeling backend, after years of effort, a new version of Home Energy Score was released in 2021 utilizing DOE's flagship energy modeling software, EnergyPlus. The updated architecture leverages modeling advancements and enables new building technologies to be added to the Scoring Tool. The new release represents a leap forward in harmonizing modeling assumptions across DOE and industry programs. In this paper we discuss the rigorous approach to model comparison with DOE2 undertaken prior to the update, utilizing test homes and real homes from the Home Energy Score database to strike a balance between consistency and more accurate energy predictions. We also discuss additional new capabilities, including improvements made to the upgrade recommendations methodology, the inclusion of an energy cost estimate metric based on ResStock analysis for use in home appraisals, and improved data analysis for quality assurance. Finally, we look at the impact Home Energy Score has had over the last decade and its future potential as its uptake in state energy plans, local ordinances, utility programs, and real estate data continues to grow.

building energy modeling↗

Double Deep Q-Networks for Optimizing Electricity Cost of a Water Heater

Electric water heaters represent 14% of the electricity consumption in the residential buildings and the cost associated with domestic water heating account for a good portion of the household expenses in the United States. In this context, intelligent control of water heaters gained a lot of research attention. In recent years, a significant number of intelligent water heater controllers, with various methods and intended uses, have been proposed. However, existing studies are mostly model-based approaches that require an accurate modelling of the water heater. Towards addressing this research gap, this paper presents a model-free reinforcement learning-based controller for a day-ahead price market. The controller aims to minimize the cost of domestic water heating while maintaining the user comfort. The results showed that the developed controller can help save energy cost while maintaining the temperatures within the desired comfort band.

Amasyali, Kadir↗

Experimental Evaluation of Refrigerant Leak Characteristics for Different HVAC&R Equipment Types–Phase 2

The US Department of Energy (DOE) Building Technology Office (BTO) and the Air-conditioning, Heating & Refrigeration Technology Institute (AHRTI) collaborated to sponsor an experimental study of refrigerant leak characteristics at Oak Ridge National Laboratory (ORNL); AHRTI project 9012. The project has been conducted in two phases with objectives to conduct refrigerant leak tests on several heating, ventilating, air-conditioning and refrigeration (HVAC&R) systems under operating conditions representative of actual applications to document the pressure decay rate and the mass flow rate of leaked refrigerant as a function of time. Phase 1 of the project ran from late 2017 to late 2018 with refrigerant leaks imposed on five systems and the collection of data to meet the project objectives. Systems chosen covered three air-conditioning (AC) applications (packaged terminal AC or PTAC, 3-ton residential split system AC, and 5-ton packaged rooftop AC) and two refrigeration applications (split system unit cooler, and standalone display case). AHRTI members donated the test systems used for the project. The systems were tested at two different leak rates (catastrophic high rate simulating full line break and a lower flow rate), two leak locations (high-pressure side and low-pressure side), and two operating conditions (compressor ON or OFF). Phase 1 results were summarized in a project report by Baxter, et al. (2019)1. The leak rates imposed in Phase 1 led to much more rapid charge releases than the more typical much slower rates seen in practice that would take days, weeks, or months to empty a system of its entire charge. For Phase 2, the project sponsors asked that the “higher” leak rate target a total charge release time of about 4 min. This was intended to represent a “reasonable” worst case release scenario to match the refrigerant leak rate assumption used in the International Electrotechnical Commission (IEC) standard IEC 60335-2-40 (2016 version [IEC 2016]. A charge release time of about 20–40 min (leak release rate 5 to 10 times lower than higher rate) was targeted for the “lower” leak rate. This report provides a summary of the Phase 2 effort. Two additional HVAC systems were selected for testing in this phase. First was a multi-split air-conditioning (MS-AC) system with one outdoor section and two indoor units and a nameplate refrigerant charge of 1.75 kg (3.86 lb.) of R-410A. The MS-AC was tested in cooling only or AC operation. Second was a split system heat pump coupled to two different representative supply duct systems (HP-duct) and a nameplate charge of 3.83 kg (8.44 lb.) of R-410A. This system was tested in both space heating and AC modes. As in Phase 1 of the project, all tests were conducted using R-410A.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Load Profiles for the U.S. Building Stock

The End-Use Load Profiles for the U.S. Building Stock project uses New ResStock and ComStock models to statistically represent the energy use of U.S. buildings. The project's hybrid approach combines best-available ground truth data, such as submetering studies and statistical disaggregation of whole-building interval meter data, with the reach, cost-effectiveness, and granularity of physics-based and data-driven building stock modeling to deliver a nationally-comprehensive data set at a fraction of the historical cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhancing thermal resilience of US residential homes in hot humid climates during extreme temperature events

Increasing occurrences of extreme weather events such as winter storms and heat waves due to climate change pose enormous safety and health-related risks to people, particularly in economically disadvantaged communities. In this study, we investigate some of the most promising retrofittable and weatherization methods to keep the living zone of residential buildings within an acceptable safety level. We use hours of safety as the resilience metric, which is defined as the time taken by the building's indoor environment to reach a safety threshold temperature. We first identify various passive measures, such as adding extra insulation, improving air sealing, and integrating phase-change materials, which can operate without any external power during winter-storm and heat-wave events. We then employ a whole-building simulation tool to examine the impact of various combinations of retrofit measures and conduct a parametric study to determine the optimal solutions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final Technical Report

Statement of the problem or situation that is being addressed in your application. The DOE and its national laboratories developed the Home Energy Score™ (HES) to encourage homeowners to improve their energy performance, lower costs and to share energy information through the MLS listing, appraisal, and financing channels. While the HES is an instrumental tool, it is currently underutilized and consists of technical, structural and sector barriers which need to be addressed in order to scale and many energy efficiency contractors are understandably overwhelmed by the added time and effort and lack of incentive to sell and deliver deep retrofit projects while simultaneously meeting the DOE HES program requirements; consequently, contractors may decide to forgo participation. Home Energy Rating System (HERS) Raters have the opportunity to play the critical Assessor role in producing a Home Energy Score (HES); this role has immense potential but currently is unfulfilled. Lastly, while utilities are interested in their customer base achieving greater energy efficiency, especially to help offset growing residential loads in states like California that are accelerating electrification, utilities do not have access to the market actors who are on the front line of influence to homeowners or review and approve their permits: HERS Raters, assessors, contractors and building departments. General statement of how this problem is being addressed: ConSol will integrate the Home Energy Score™ (HES) to its State of California, approved home energy rating services (HERS) platform (CHEERS) to develop a single tool for contractors nationwide to assess, record and install recommended cost, energy, and emissions saving measures to the 140 million single-family homes throughout the U.S. and 14 million homes in California (CHEERS+HES). The CHEERS high fidelity energy code permitting data will be integrated with HES for simple, accurate, easy-to-use home energy estimation and analysis and will directly gain access to the retrofit and renovations markets with the same upgraded platform. This innovative project will assist the utilities in supporting existing homes in their jurisdictions with HES and develop measures to improve energy efficiency and reduce emissions. How is this problem being addressed? What is the overall project approach? In effort to expand the Home Energy Score™ (HES) by increasing the use of aggregable home energy asset data, ConSol proposes to integrate the DOE HES via Application Programming Interface (API) to its State of California approved home energy rating services platform (CHEERS). Once the CHEERS platform and HES are integrated (CHEERS+HES), this enhanced platform will be instantly available and actively deployed via Phase 1 pilot to HERS Raters, assessors and contractors in California to market-test the solution, understand the rate of adoption and identify opportunities for improvement prior to scaling nationally. The CHEERS high fidelity energy code permitting data will be integrated with HES for simple, accurate, easy-to-use home energy estimation and analysis and will directly gain access to the retrofit and renovations markets with the same upgraded platform. This innovative project will assist the building industry and homeowners with an easy-to-use assessment if energy and carbon impacts of existing homes, and assist the utilities in supporting existing homes in their jurisdictions with HES to improve energy efficiency and reduce emissions. What is to be done in Phase I? During Phase I of this proposed project, ConSol will (1) design software architecture that links CHEERS to the Home Energy ScoreTM via API, (2) solicit partnership from one or more California utilities for a regional pilot, (3) test the new software with its HERS Raters and contractor network in the partnership utility jurisdiction, (4) launch a pilot version of the newly developed software with HERS Raters and contractors in the utility territory, and (5) explore California’s GoGreen energy efficiency homeowner lending program in parallel with the pilot. Commercial Applications and Other Benefits. Summarize the future applications or public benefits if the project is carried over into Phase II or Phase III and beyond. The CHEERS+HES commercialized product will be ready for national market scale following a successful Phase 1 performance. The CHEERS+HES adoption is estimated to reach a 5% adoption growth rate versus the 110,000 baseline, starting in Year 1 after Phase I completion, and continuing each year. As a direct benefit to the DOE, CHEERS will set a goal of 100,000 Home Energy Score assessments for existing home alterations within the first 10 years following Phase 1 performance. The technical benefits of this proposed project include the harmonized, automated, and seamless integration of the DOE HES into the widely used and market leading California energy registry, CHEERS. The social benefits include the aggregate energy, cost and GHG savings by allowing the broader public streamlined access to the CHEERS+HES measurement and the energy efficiency recommended measures that may result. Key Words: Home Energy ScoreTM (HES); Application Programming Interface (API); Home Energy Rating Services (HERS); HERS Raters; contractors; assessors; existing homes, energy asset data; cost, energy, and emissions saving measures; energy code (Title 24) compliance; document repository; utilities; pilot; newly developed software; energy efficiency; homeowner. Summary for Members of Congress: The DOE Home Energy Score™ (HES) is a tool to encourage homeowners to improve their energy performance, lower costs and share energy information but is underutilized and consists of barriers which need to be addressed in order to scale. In effort to expand the HES, CHEERS, Inc. will integrate the HES to its State of California, approved home energy rating services (HERS) platform (CHEERS) to develop a single tool for contractors nationwide to assess, record and install recommended cost, energy, and emissions saving measures to the 140 million single-family homes throughout the U.S. and 14 million homes in California.

Application Programming Interface (API)↗

MEASUR Up: Identifying opportunities in a facility

The commercial and industrial sectors account for nearly half of the total U.S. energy consumption. To help these sectors reduce their energy intensity, the U.S. Department of Energy (DOE) designed the Better Buildings, Better Plants Initiative. Through this initiative, more than 900 industrial, commercial, public and residential organizations commit to long-term sustainability goals and share their proven energy efficiency strategies, which inspire others to tap into the continued potential for energy efficiency. Collectively, these organizations have saved 2.5 quadrillion BTUs of energy, equivalent to US$15.3 billion, and 155 million metric tons of carbon dioxide. Within the initiative, the Better Plants side of the program focuses specifically on the industrial sector. More than 270 industrial partners have taken advantage of the unique selection of resources offered including workforce development programs, information sharing, peer-to-peer networking, diagnostic tool loans and software tools. One of the most powerful tools off ered is a revitalization of the legacy DOE software tools used by industry for decades. These have been transformed into a new, free, opensource software tool suite: MEASUR (Manufacturing Energy Assessment Software for Utility Reduction)

Armstrong, Kristina↗

Remediation of Temporary Storage Sites in Support of the Port Hope Area Initiative - 20295

The Port Hope Area Initiative is a community-based solution for the long-term management of historic low level radioactive waste (LLRW) resulting from 60 years of uranium and radium processing operations in the Town of Port Hope which is located in Ontario, Canada. The Eldorado refinery, on the north shore of Lake Ontario, began refining radium-226 from pitchblende ore, later transitioning to the refining of uranium. Through the history of the operation, LLRW was deposited throughout the town of Port Hope as a result of fugitive emissions from the plant and/or through the re-use of process residues as building material and backfill. Historical clean-up activities conducted in the late 1970's involved the remediation of approximately 400 properties and the relocation of 100,000 cubic metres of contaminated soil to a disposal facility in Chalk River operated by Atomic Energy of Canada Limited (AECL). Owing to space limitations at that disposal facility, any LLRW identified through construction monitoring since that time has been stored in the community at three temporary storage sites located throughout the town. These include: the Centre Pier mound that contained approximately of 19,800 m{sup 3} of LLRW-impacted soil that originated from the construction of a new water treatment plant; two mounds located at a licensed storage facility containing LLRW obtained from residential clean-up activities (11,000 m{sup 3}); and a small pad adjacent to the municipal sewage treatment plant containing 2200 m{sup 3} of LLRW-containing sludge. With the construction of a new long-term waste management facility (LTWMF) that has been designed to house all of the LLRW identified within Port Hope, the three sites were early candidates for remediation. The clean-up of the three temporary storage sites was a significant milestone for the Port Hope Area Initiative. After a decade of planning and consultation, this work represents the first sites in the municipality to be remediated with the waste being safety removed and transferred to the newly constructed LTWMF. This paper discusses the challenges associated with the clean-up activities for these three sites and the strategies employed to address those challenges. These included weather-related challenges, owing to the seasons over which the work was conducted as well as those associated with working within a closely-knit community. Canadian Nuclear Laboratories (CNL), working on behalf of the federal government, has worked diligently to develop a positive and trusting relationship with the community. Consequently, the successful execution of this project needed to be sensitive to, and respectful of the needs of the community. In addition to the usual Health, Safety and Environment training, project staff received community awareness training that spoke to the history of this community-based initiative and the expected behavior when working within the community. Transportation routes were defined based on safety and the need to minimize disruption to local traffic while haul-times where scheduled around school bus hours to enhance public safety. The successful completion of this first of many remediation projects to be completed under the Port Hope Area Initiative reflected years of careful planning. Nevertheless, there were a number of 'lessons learned' that have been applied on other ongoing projects be completed under the Port Hope Area Initiative. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High-Performance Integrated Window and Façade Solutions for California

The researchers developed a new generation of high-performance façade systems and supporting design and management tools to support industry in meeting California’s greenhouse gas reduction targets, reduce energy consumption, and enable an adaptable response to minimize real-time demands on the electricity grid. The project resulted in five outcomes: (1) The research team developed an R-5, 1-inch thick, triplepane, insulating glass unit with a novel low-conductance aluminum frame. This technology can help significantly reduce residential cooling and heating loads, particularly during the evening. (2) The team developed a prototype of a windowintegrated local ventilation and energy recovery device that provides clean, dry fresh air through the façade with minimal energy requirements. (3) A daylight-redirecting louver system was prototyped to redirect sunlight 15–40 feet from the window. Simulations estimated that lighting energy use could be reduced by 35–54 percent without glare. (4) A control system incorporating physics-based equations and a mathematical solver was prototyped and field tested to demonstrate feasibility. Simulations estimated that total electricity costs could be reduced by 9-28 percent on sunny summer days through adaptive control of operable shading and daylighting components and the thermostat compared to state-of-the-art automatic façade controls in commercial building perimeter zones. (5) Supporting models and tools needed by industry for technology R&D and market transformation activities were validated. Attaining California’s clean energy goals require making a fundamental shift from today’s ad-hoc assemblages of static components to turnkey, intelligent, responsive, integrated building façade systems. These systems offered significant reductions in energy use, peak demand, and operating cost in California.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Short-term apartment-level load forecasting using a modified neural network with selected auto-regressive features

Residential electricity load profiles and their diversity have become increasingly important to realize the benefits of Smart or Transactive Energy Networks (TENs). An important element of TENs will be practical, accurate, and implementable residential load forecasting techniques. While there have been many approaches to short-term load forecasting, few have included forecasting for individual households, partly because the high volatility and idiosyncrasies present in individual household load data can pose significant challenges. In this study, we develop a Convolutional Long Short-Term Memory-based neural network with Selected Autoregressive Features (termed a CLSAF model) to improve short-term household electricity load forecasting accuracy by employing three strategies: autoregressive features selection, exogenous features selection, and a “default” state to avoid overfitting at times of high load volatility. We include aggregations of apartments to floor and building level, because utilities may favor transactive approaches that rely on aggregator models, e.g., a cluster of consumers as opposed to an individual. We demonstrate that the CLSAF model, by virtue of its enhanced feature representation and modest computational resources, can accomplish load forecasting in a multi-family residential building across three spatial granularities (individual apartment/household, floor, and building levels), with an accuracy improvement of up to 25% compared to a persistence model. We propose a data screening technique to characterize time-series electricity-load data. This technique is suitable for integration into a TEN ecosystem and allows one to estimate confidence levels of the load forecasts to optimize computational resources and the risks associated with uncertain forecasts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Machine Learning-Driven Optimization of Building Enclosures for Moisture Durability and Thermal Performance

The design of moisture-durable building enclosures with low embodied carbon often involves an iterative process of selecting the materials for the specific exposure conditions to meet the performance requirements. While hygrothermal simulations are commonly used to evaluate moisture durability, they often require advanced expertise for proper implementation. Machine learning (ML) provides a promising alternative by streamlining the design process and minimizing the reliance on complex simulations. This study presents a machine learning-based approach for predicting moisture durability in residential wall assemblies. The ML model was trained to estimate the mold index and maximum moisture content of various layers under typical exposure conditions. The model achieved a high predictive accuracy, with a coefficient of determination (R²) exceeding 0.90 when compared to traditional hygrothermal simulations on materials that were not part of training the ML model. Building on these results, the ML model was developed into a practical tool for optimizing wall assembly designs. This tool allows users to automatically optimize material selections based on energy, moisture, and carbon performance criteria. By incorporating multi-objective optimization, the tool identifies configurations that minimize embodied carbon while maintaining moisture safety and code-compliant thermal performance. Additionally, it provides insights into how material choices influence assembly durability, energy efficiency, and carbon reduction. The tool will be implemented in the Building Science Advisor (BSA) to enhance its performance and provide more granularity on the results. This research highlights the potential for ML-driven tools to simplify the design of high-performance building enclosures, offering architects and engineers a faster, more efficient way to balance critical performance factors.

Salonvaara, Mikael [ORNL] (ORCID:0000000318991554)↗

Building Life-Cycle Analysis with the GREET Building Module: Methodology, Data, and Case Studies

To holistically address building sustainability, Argonne National Laboratory has expanded its Greenhouse gases, Regulated Emissions, and Energy use in Technologies (GREET) life-cycle model with a new GREET Building Module. This report documents life-cycle analysis (LCA) methodology and foreground data that Argonne National Laboratory compiles and develops to address embodied greenhouse gas (GHG) emissions and energy impacts of a wide range of envelope and structural building materials for new construction and retrofits. The methodology and data form the backbone of the GREET Building Module. This research effort focuses on developing consistent LCA methodology that conforms to building LCA standards such as the EN 15978 to address embodied GHG emissions and energy impacts of building materials/technologies. We document detailed foreground data for selected building materials and building components that are common for building construction. To test the LCA methodology and the GREET Building Module, this report includes case studies of insulation materials and wall panels for residential building retrofit. We have developed a separate document as a User Guide for understanding and applying the GREET Building Module to conduct detailed, process-level LCA of embodied carbon and energy impacts of emerging building materials and technology solutions that of interest to the Building Technologies Office (BTO) of the US Department of Energy, researchers, and industry stakeholders.

42 ENGINEERING↗

Optimizing HVAC Operations in Multi-unit Buildings for Grid Demand Response

The thermal inertia of buildings, along with the flexibility associated with thermostatically controlled loads (TCL) allows heating ventilation and cooling (HVAC) systems to be used for grid demand response (DR). In this work, we consider an HVAC system that serves multiple units in a residential building to meet their space heating requirements. We aim to determine the optimal power flow to each unit that minimizes the power costs incurred by the building's occupants while keeping in consideration their thermal comfort. The DR program is assumed to allow the building temperatures to deviate from the set-points up to a maximum limit. Despite the complex, non-linear structure of the problem, we show how the optimal solutions can be obtained efficiently using quadratic programming. Since HVAC systems can run on either electricity or natural gas, we study the efficacy of the DR regime for both hourly electricity prices and flat gas prices over the course of 24 hours. Finally, we run simulations to determine the optimal thermal power and the evolution of unit temperatures for various energy pricing schemes.

Naqvi, Syed A.↗

Virtual Refrigerant Charge Sensing Method for Next-Generation Refrigerant in Residential Heat Pumps

The charge level of refrigerant in heat pump systems significantly affects their operational performance. Virtual refrigerant charge (VRC) sensing technology has been well-established for traditional refrigerants (HFCs and HCFCs) for its low cost compared to physical sensors. However, other than traditional refrigerants, HFOs are increasingly used in next-generation heat pumps; whether these conventional VRC sensing methods remain applicable for heat pump systems utilizing next-generation refrigerants requires further investigation. To address these issues, this study develops a low-cost VRC sensing method for next-generation refrigerant heat pumps used in residential buildings. The developed algorithm is evaluated by using simulation models to evaluate the accuracy, considering an R454B heat pump with a nominal heating capacity of 51K Btu/hr (14.95 kW) as an example, and compared with those of the two reference VRC sensing algorithms. Though the developed VRC sensing algorithm and the two reference methods can accurately predict the charge level for the R454B heat pump system (with mean absolute percentage error for various cooling and heating conditions less than 7%), the developed VRC sensing algorithm uses fewer sensors and improves the overall accuracy for heating conditions by 7.1%, and the accuracy for undercharge cooling conditions 14.2%, compared with a mainstream algorithm. This technology will complement physical leakage detectors, and promote the adoption of next-generation heat pump systems, along with reducing wasted energy and maintenance costs.

Liang, Chenjiyu↗

Artificial Intelligence Thermostat to Detect Faults

Residential air conditioners and heat pumps often experience faults due to inadequate maintenance, which can severely reduce efficiency or even cause system failure. Common issues include dirty or clogged air filters and refrigerant leaks. These problems degrade performance and increase energy use and operating costs. This study presents a smart thermostat with embedded artificial intelligence to detect such faults and alert homeowners when maintenance is needed. The thermostat uses low-cost measurements—including return-air temperature, relative humidity, supply-air temperature, outdoor-air temperature, and condenser subcooling—to identify abnormal operations. Because different faults produce distinct response patterns, tailored algorithms are developed to recognize characteristic fault signatures. The investigation is built on a detailed co-simulation platform that couples EnergyPlus with the DOE/ORNL Heat Pump Design Model (HPDM). EnergyPlus represents the building’s dynamic environment, while HPDM is a high-fidelity, hardware-based model that can simulate fault-free performance as well as a wide range of faults, including gradual degradation such as minor refrigerant leakage. This platform provides a virtual training and testing environment that helps distinguish fault-induced behavior from normal operation and supports development of robust diagnostic algorithms. Using this framework, a Dynamic Bayesian Network was developed to identify two common faults—gradual refrigerant charge loss and indoor airflow blockage—and the AI-embedded thermostat was verified through annual building simulations.

Shen, Bo [ORNL] (ORCID:0000000336600393)↗

Certified Green Building Materials: Policy Impact Assessment

Chinese building construction is rapidly expanding, making it critical to focus on energy efficiency to curb the increase of energy consumption and emissions over a building’s lifetime. A key mechanism to do so is through building material certification systems and programs. These establish how building materials will perform and can be used to promote energy and resource efficiency, which help create a more sustainable and healthy building industry. This report begins by identifying characteristics of a strong certification system and ways to improve existing systems. To curb building energy demand, the Chinese government began developing a building material certification program to encourage energy and resource efficiency in the building sector. A timeline is provided of their program’s development and provides analysis. China’s building material database is highlighted and analyzed for their significance and opportunities for improvement. The report then continues to analyze the importance of policies such as procurement programs, and the Chinese government is developing their procurement programs for certified green building materials. To understand the potential large-scale impacts of green building material certifications, we conducted an analysis of the environmental and market impact of a nationwide green building procurement policy for all new residential and commercial construction.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluation of Rooftop Solar Potential in Chernihiv and Lviv, Ukraine, and Efficacy of High-Resolution 3D Data Digital Twins [Slides]

NREL evaluated rooftop solar photovoltaic (PV) siting opportunities in the cities of Chernihiv and Lviv, Ukraine, leveraging very-high-resolution 3D elevation data to calculate technical potential. The study assessed total rooftop solar capacity and annual energy production. In Chernihiv and Lviv, 116,503 buildings were analyzed for their rooftop solar potential. The buildings in the study areas include a mixture of residential, commercial, and industrial buildings, characterized by diverse roof shapes and sizes. The total estimated rooftop solar capacity is 332 MWDC in Chernihiv and 873 MWDC in Lviv with annual energy production up to 376.2 GWhDC in Chernihiv and 995.5 GWhDC in Lviv. This accounting provides a clear estimate of the potential rooftop solar installations that could be realized under optimal conditions, considering both technical constraints and the geographic distribution of available rooftop space. Related to Russia's invasion of Ukraine, NREL estimates loss from buildings damaged or destroyed of 2,754 buildings, 20.15 MWDC of capacity, and 22,869 MWhDC of annual energy production in Chernihiv as well as a loss of 1,316 buildings, 34.49 MWDC of capacity, and 39,369 MWhDC of annual energy production in Lviv. The study also assessed the feasibility of adapting this methodology on a national scale using either simulated digital surface models (DSMs) or a digital twin approach. While the very-high-resolution DSM provided more precise results, the simulated DSM demonstrated reasonable accuracy for broader applications in modeling aggregated distributed solar supply. The feasibility of using a digital twin for Ukraine's national rooftop solar potential is considered promising, with certain limitations in areas with highly variable building stock and heavy war damage.

14 SOLAR ENERGY↗