Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Relocation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Crystallization and preliminary X-ray diffraction anaylsis of the LOV1 domains of phototropin 1 and 2 from Arabidopsis thaliana

Crystals of the LOV1 domains of phototropin 1 and 2 from A. thaliana were obtained which diffracted X-rays to a resolution of at least 2.1 Å. Phototropin is a blue-light receptor protein in plants that is responsible for phototropic responses, stomata opening and photo-induced relocation of chloroplasts. Higher plants such as Arabidopsis thaliana have two isoforms of phototropin: phototropin 1 and phototropin 2. Both isoforms comprise a tandem pair of blue-light-absorbing light–oxygen–voltage domains named LOV1 and LOV2 in the N-terminal half and a serine/threonine kinase domain in the C-terminal half. The LOV1 domain is thought to function as a dimerization site. In the present study, recombinant LOV1 domains of A. thaliana phototropin 1 and phototropin 2 were crystallized. The crystal of the LOV1 domain of phototropin 1 belonged to the orthorhombic space group P2{sub 1}2{sub 1}2{sub 1}, with unit-cell parameters a = 61.2, b = 64.9, c = 70.8 Å, and diffracted X-rays to a resolution of 2.1 Å. The crystal of the LOV1 domain of phototropin 2 belonged to space group P2{sub 1}, with unit-cell parameters a = 32.5, b = 66.5, c = 56.7 Å, β = 92.4°, and diffracted X-rays to beyond 2.0 Å resolution. In both crystals, two LOV1 domains occupied the crystallographic asymmetric unit.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Disk Density Tuning of a Maximal Random Packing

We introduce an algorithmic framework for tuning the spatial density of disks in a maximal random packing, without changing the sizing function or radii of disks. Starting from any maximal random packing such as a Maximal Poisson-disk Sampling (MPS), we iteratively relocate, inject (add), or eject (remove) disks, using a set of three successively more-aggressive local operations. We may achieve a user-defined density, either more dense or more sparse, almost up to the theoretical structured limits. The tuned samples are conflict-free, retain coverage maximality, and, except in the extremes, retain the blue noise randomness properties of the input. We change the density of the packing one disk at a time, maintaining the minimum disk separation distance and the maximum domain coverage distance required of any maximal packing. These properties are local, and we can handle spatially-varying sizing functions. Using fewer points to satisfy a sizing function improves the efficiency of some applications. We apply the framework to improve the quality of meshes, removing non-obtuse angles; and to more accurately model fiber reinforced polymers for elastic and failure simulations.

97 MATHEMATICS AND COMPUTING↗

The subcellular distribution of the Arabidopsis histidine phosphotransfer proteins is independent of cytokinin signaling

Cytokinins are a class of mitogenic plant hormones that play an important role in most aspects of plant development, including shoot and root growth, vascular and photomorphogenic development and leaf senescence. A model for cytokinin perception and signaling has emerged that is similar to bacterial two-component phosphorelays. In this model, binding of cytokinin to the extracellular domain of the Arabidopsis histidine kinase (AHKs) receptors induces autophosphorylation within the intracellular histidine-kinase domain. The phosphoryl group is subsequently transferred to cytosolic Arabidopsis histidine phosphotransfer proteins (AHPs), which have been suggested to translocate to the nucleus in response to cytokinin treatment, where they then transfer the phosphoryl group to nuclear-localized response regulators (Type-A and Type-B ARRs). We examined the effects of cytokinin on AHP subcellular localization in Arabidopsis and, contrary to expectations, the AHPs maintained a constant nuclear/cytosolic distribution following cytokinin treatment. Furthermore, mutation of the conserved phosphoacceptor histidine residue of the AHP, as well as disruption of multiple cytokinin signaling elements, did not affect the subcellular localization of the AHP proteins. Finally, we present data indicating that AHPs maintain a nuclear/cytosolic distribution by balancing active transport into and out of the nucleus. Our findings suggest that the current models indicating relocalization of AHP protein into the nucleus in response to cytokinin are incorrect. Rather, AHPs actively maintain a consistent nuclear/cytosolic distribution regardless of the status of the cytokinin response pathway.

59 BASIC BIOLOGICAL SCIENCES↗

The Effects of Quality Control on Decreasing Error Propagation in the LandScan USA Population Distribution Model: A Case Study of Philadelphia County

Landscan USA is a high resolution dasymetric model incorporating multiple ancillary variables to distribute populations. LandScan USA is a valuable tool in determining the population at risk during emergency response situations. However, a critical evaluation is necessary to produce user confidence regarding model accuracy through the verification and validation of model outputs. Unfortunately, dynamic models, such as population distribution, are often not validated due to the difficulty of having multiple input datasets and lack of validated data. A validated dataset allows analysis of model accuracy, as well as quantifying the benefits and costs of improving input datasets compared to find a balance for producing the best model. This paper examines inaccuracies present within the input variables of two national school datasets incorporated in the model. Schools were chosen since a validated school dataset exists for Philadelphia County, Pennsylvania. Quality control efforts utilized throughout the LandScan USA process are quantified to determine the degree of quality control necessary to have a statistically significant effect on model output. Typical LandScan USA quality control resulted in 43% of school enrollment values changed, compared to 89% for the validated dataset. Normal quality control methods resulted in 36% of schools being spatially relocated compared to 87% for the validated dataset. However, the costs of increasing quality control from normal to the validated dataset equated to a 600% increase in manual labor time for statistically insignificant improvements in LandScan USA daytime. This study enabled validation verification of not only the quality control process for LandScan USA, but also provides confidence in model output and use for policy issues, planning and emergency situations.

97 MATHEMATICS AND COMPUTING↗

Peel-and-Stick Sensors Powered by Directed RF Energy

PARC, a Xerox Company, is developing a low-cost system of peel-and-stick wireless sensors that will enable widespread building environment sensor deployment with the potential to deliver up to 30% energy savings. The system is embodied by a set of RF hubs that provide power to automatically located sensor nodes, and relay data wirelessly to the building management system (BMS). The sensor nodes are flexible electronic labels powered by rectified RF energy transmitted by an RF hub and can contain multiple printed and conventional sensors. The system design overcomes limitations in wireless sensors related to power delivery, lifetime, and cost by eliminating batteries and photovoltaic devices. Sensor localization is performed automatically by the inclusion of a programmable multidirectional antenna array in the RF hub. Comparison of signal strengths while the RF beam is swept allows for sensor localization, reducing installation effort and enabling automatic recommissioning of sensors that have been relocated, overcoming a significant challenge in building operations. PARC has already demonstrated wireless power and temperature data transmission up to a distance of 20m with less than one minute between measurements, using power levels well within the FCC regulation limits in the 902-928 MHz ISM band. The sensor’s RF energy harvesting antenna achieves high performance with dimensions below 5cm x 9cm

Lalau-Keraly, Christopher↗

Mounting a thermocouple of type E onto a Cu single crystal for use in a magnetically sensitive environment below 77 K

Type E thermocouples show magnetic effects at liquid nitrogen temperature and below. This may cause trouble in experiments that are sensitive to magnetic stray fields like nuclear magnetic resonance, photoemission or high resolution electron energy loss spectroscopy. Here, a solution for the temperature measurement of a single crystal is presented. The authors weld a copper rod onto the back side of the single crystal, thereby relocating the sensitive sample from the thermocouple attachment position. They show that it is possible to measure the crystal temperature at the end of the rod while significantly reducing the ferromagnetic influence due to the increased distance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Anniversary Paper: The role of medical physicists in developing stereotactic radiosurgery

This article is a tribute to the pioneering medical physicists over the last 50 years who have participated in the research, development, and commercialization of stereotactic radiosurgery (SRS) and stereotactic radiotherapy utilizing a wide range of technology. The authors have described the evolution of SRS through the eyes of physicists from its beginnings with the Gamma Knife in 1951 to proton and charged particle therapy; modification of commercial linacs to accommodate high precision SRS setups; the multitude of accessories that have enabled fine tuning patients for relocalization, immobilization, and repositioning with submillimeter accuracy; and finally the emerging technology of SBRT. A major theme of the article is the expanding role of the medical physicist from that of advisor to the neurosurgeon to the current role as a primary driver of new technology that has already led to an adaptation of cranial SRS to other sites in the body, including, spine, liver, and lung. SRS continues to be at the forefront of the impetus to provide technological precision for radiation therapy and has demonstrated a host of downstream benefits in improving delivery strategies for conventional therapy as well. While this is not intended to be a comprehensive history, and the authors could not delineate every contribution by all of those working in the pursuit of SRS development, including physicians, engineers, radiobiologists, and the rest of the therapy and dosimetry staff in this important and dynamic radiation therapy modality, it is clear that physicists have had a substantial role in the development of SRS and theyincreasingly play a leading role in furthering SRS technology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Range and modulation dependencies for proton beam dose per monitor unit calculations

Calculations of dose per monitor unit (D/MU) are required in addition to measurements to increase patient safety in the clinical practice of proton radiotherapy. As in conventional photon and electron therapy, the D/MU depends on several factors. This study focused on obtaining range and modulation dependence factors used in D/MU calculations for the double scattered proton beam line at the Midwest Proton Radiotherapy Institute. Three dependencies on range and one dependency on modulation were found. A carefully selected set of measurements was performed to discern these individual dependencies. Dependencies on range were due to: (1) the stopping power of the protons passing through the monitor chamber; (2) the reduction of proton fluence due to nuclear interactions within the patient; and (3) the variation of proton fluence passing through the monitor chamber due to different source-to-axis distances (SADs) for different beam ranges. Different SADs are produced by reconfigurations of beamline elements to provide different field sizes and ranges. The SAD effect on the D/MU varies smoothly as the beam range is varied, except at the beam range for which the first scatterers are exchanged and relocated to accommodate low and high beam ranges. A geometry factor was devised to model the SAD variation effect on the D/MU. The measured D/MU variation as a function of range can be predicted within 1% using the three modeled dependencies on range. Investigation of modulated beams showed that an analytical formula can predict the D/MU dependency as a function of modulation to within 1.5%. Special attention must be applied when measuring the D/MU dependence on modulation to avoid interplay between range and SAD effects.

61 RADIATION PROTECTION AND DOSIMETRY↗

Monitoring radiation use in cardiac fluoroscopy imaging procedures

Purpose: Timely identification of systematic changes in radiation delivery of an imaging system can lead to a reduction in risk for the patients involved. However, existing quality assurance programs involving the routine testing of equipment performance using phantoms are limited in their ability to effectively carry out this task. To address this issue, the authors propose the implementation of an ongoing monitoring process that utilizes procedural data to identify unexpected large or small radiation exposures for individual patients, as well as to detect persistent changes in the radiation output of imaging platforms. Methods: Data used in this study were obtained from records routinely collected during procedures performed in the cardiac catheterization imaging facility at St. Andrew's War Memorial Hospital, Brisbane, Australia, over the period January 2008-March 2010. A two stage monitoring process employing individual and exponentially weighted moving average (EWMA) control charts was developed and used to identify unexpectedly high or low radiation exposure levels for individual patients, as well as detect persistent changes in the radiation output delivered by the imaging systems. To increase sensitivity of the charts, we account for variation in dose area product (DAP) values due to other measured factors (patient weight, fluoroscopy time, and digital acquisition frame count) using multiple linear regression. Control charts are then constructed using the residual values from this linear regression. The proposed monitoring process was evaluated using simulation to model the performance of the process under known conditions. Results: Retrospective application of this technique to actual clinical data identified a number of cases in which the DAP result could be considered unexpected. Most of these, upon review, were attributed to data entry errors. The charts monitoring the overall system radiation output trends demonstrated changes in equipment performance associated with relocation of the equipment to a new department. When tested under simulated conditions, the EWMA chart was capable of detecting a sustained 15% increase in average radiation output within 60 cases (<1 month of operation), while a 33% increase would be signaled within 20 cases. Conclusions: This technique offers a valuable enhancement to existing quality assurance programs in radiology that rely upon the testing of equipment radiation output at discrete time frames to ensure performance security.

60 APPLIED LIFE SCIENCES↗

Dosimetric and deformation effects of image-guided interventions during stereotactic body radiation therapy of the prostate using an endorectal balloon

Purpose: During stereotactic body radiation therapy (SBRT) for the treatment of prostate cancer, an inflatable endorectal balloon (ERB) may be used to reduce motion of the target and reduce the dose to the posterior rectal wall. This work assessed the dosimetric impact of manual interventions on ERB position in patients receiving prostate SBRT and investigated the impact of ERB interventions on prostate shape. Methods: The data of seven consecutive patients receiving SBRT for the treatment of clinical stage T1cN0M0 prostate cancer enrolled in a multi-institutional, IRB-approved trial were analyzed. The SBRT dose was 50 Gy in five fractions to a planning target volume (PTV) that included the prostate (implanted with three fiducial markers) with a 3-5 mm margin. All plans were based on simulation images that included an ERB inflated with 60 cm{sup 3} of air. Daily kilovoltage cone-beam computed tomography (CBCT) imaging was performed to localize the PTV, and an automated fusion with the planning images yielded displacements required for PTV relocalization. When the ERB volume and/or position were judged to yield inaccurate repositioning, manual adjustment (ERB reinflation and/or repositioning) was performed. Based on all 59 CBCT image sets acquired, a deformable registration algorithm was used to determine the dose received by, displacement of, and deformation of the prostate, bladder (BLA), and anterior rectal wall (ARW). This dose tracking methodology was applied to images taken before and after manual adjustment of the ERB (intervention), and the delivered dose was compared to that which would have been delivered in the absence of intervention. Results: Interventions occurred in 24 out of 35 (69%) of the treated fractions. The direct effect of these interventions was an increase in the prostate radiation dose that included 95% of the PTV (D95) from 9.6 {+-} 1.0 to 10.0 {+-} 0.2 Gy (p = 0.06) and an increase in prostate coverage from 94.0% {+-} 8.5% to 97.8% {+-} 1.9% (p = 0.03). Additionally, ERB interventions reduced prostate deformation in the anterior-posterior (AP) direction, reduced errors in the sagittal rotation of the prostate, and increased the similarity in shape of the prostate to the radiotherapy plan (increased Dice coefficient from 0.76 {+-} 0.06 to 0.80 {+-} 0.04, p = 0.01). Postintervention decreases in prostate volume receiving less than the prescribed dose and decreases in the voxel-wise displacement of the prostate, bladder, and anterior rectal wall were observed, which resulted in improved dose-volume histogram (DVH) characteristics. Conclusions: Image-guided interventions in ERB volume and/or position during prostate SBRT were necessary to ensure the delivery of the dose distribution as planned. ERB interventions resulted in reductions in prostate deformations that would have prevented accurate localization of patient anatomy.

60 APPLIED LIFE SCIENCES↗

SU-E-T-495: Neutron Induced Electronics Failure Rate Analysis for a Single Room Proton Accelerator

Purpose: To determine the failure rate as a function of neutron dose of the range modulator's servo motor controller system (SMCS) while shielded with Borated Polyethylene (BPE) and unshielded in a single room proton accelerator. Methods: Two experimental setups were constructed using two servo motor controllers and two motors. Each SMCS was then placed 30 cm from the end of the plugged proton accelerator applicator. The motor was then turned on and observed from outside of the vault while being irradiated to known neutron doses determined from bubble detector measurements. Anytime the motor deviated from the programmed motion a failure was recorded along with the delivered dose. The experiment was repeated using 9 cm of BPE shielding surrounding the SMCS. Results: Ten SMCS failures were recorded in each experiment. The dose per monitor unit for the unshielded SMCS was 0.0211 mSv/MU and 0.0144 mSv/MU for the shielded SMCS. The mean dose to produce a failure for the unshielded SMCS was 63.5 ± 58.3 mSv versus 17.0 ±12.2 mSv for the shielded. The mean number of MUs between failures were 2297 ± 1891 MU for the unshielded SMCS and 2122 ± 1523 MU for the shielded. A Wilcoxon Signed Ranked test showed the dose between failures were significantly different (P value = 0.044) while the number of MUs between failures were not (P value = 1.000). Statistical analysis determined a SMCS neutron dose of 5.3 mSv produces a 5% chance of failure. Depending on the workload and location of the SMCS, this failure rate could impede clinical workflow. Conclusion: BPE shielding was shown to not reduce the average failure of the SMCS and relocation of the system outside of the accelerator vault was required to lower the failure rate enough to avoid impeding clinical work flow.

07 ISOTOPE AND RADIATION SOURCES↗

MO-B-16A-01: Memorial to Donald D. Tolbert - Memorial Lecture

The Medical Physics community lost one of its prominent leaders in April, 2013 with the passing of Donald D. Tolbert, PhD. He received his Doctorate at the University of Kansas followed by post Doctoral training at Florida State University and the University of Wisconsin. He was Chief of Radiation Therapy Medical Physics at the University of Wisconsin Hospital for 7 years before relocating to Honolulu Hawaii, where he founded the consulting group Mid-Pacific Medical Physics. Don was a leader in both the AAPM and the ACR, chairing the Professional Council and the Commission on Medical Physics. He was active on the AAPM Board of Directors and a member of the ACR Board of Chancellors. Dr. Tolbert's approach to the difficult problems of the times was admired and respected by colleagues in Medical Physics, Radiation Oncology, and Diagnostic Radiology. He always rose above the heated political rhetoric and led the discussion to higher ground. His wisdom was continually sought to solve complicated problems. Following retirement, he returned to homes in Kansas and Colorado, devoting his time to writing about coping with diabetes and providing support for Seniors in Beloit Kansas. Don is survived by his wife, Mattie, his 3 children and 5 grandchildren. He will be greatly missed.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

SU-C-19A-02: An Innovative Critical Organ Repositioner Device for Use During Radiotherapy Treatments

Purpose: In most radiation oncology applications the use of shape memory alloy (SMA) actuation can be extremely beneficial in sparing normal structures by relocating them away from the path of the external beam, or placing distance between the structure and radiation source such as in Brachytherapy. Implementation of this organ repositioner device in conjunction with IMRT could open new possibilities for dose escalation and significant dose reduction to normal tissues. Similarly, in high dose rate brachytherapy applications, the ideal effective dose may not be delivered to the target volume due to toxicity concerns to adjacent critical structures. Here we present a dual functioning device manufactured from SMA materials to: 1) provide a desirable tool to reposition the organ at risk away from the radiation source, and 2) facilitate localization when imaging the area. Methods: A Nitinol based actuator with controlled force and displacement will be incorporated in the design of an organ repositioner (e.g., a rectal marker) with the ability to recall a pre-defined shape at temperature T1 (body temp) and shift back to its original shape at temperature T2 (to facilitate removal). An open distal end permits the marker to function as a part of a barium delivery system. Results: An example of this SMA manufactured in our laboratory for atrial fibrillation radio frequency ablation is the esophagus SMA positioner, designed to position the esophagus away from the ablation area. This device shows the maximum strain in the deflected esophagus to be less than 3%. The prototype positioner deflected the organ at risk by 5 cm away from the site of ablation. Conclusions: The organ repositioner device is feasible for use in clinics, provides patient comfort due to its gradual deflection, and has dual functionality in repositioning the organ at risk as well as serving as a localization device.

60 APPLIED LIFE SCIENCES↗

SU-E-J-139: One Institution’s Experience with Surface Imaging in Proton Therapy

Purpose: X-ray system is commonly used for IGRT in proton therapy, however image acquisition not only increases treatment time but also adds imaging dose. We studied a 3D surface camera system (AlignRT) performance for proton therapy. Methods: System accuracy was evaluated with rigid phantom under two different camera location configurations. For initial clinical applications, post mastectomy chest wall and partial breast treatments were studied. X-ray alignment was used as our ground truth. Our studies included: 1) comparison of daily patient setup shifts between X-ray alignment and SI calculation; 2) interfractional breast surface position variation when aligning to bony landmark on X-ray; 3) absolute positioning using planning CT DICOM data; 4) shifts for multi-isocenter treatment plan; 5) couch isocentric rotation accuracy. Results: Camera locations affected the system performance. After camera relocation, the accuracy of the system for the rigid phantom was within 1 mm (fixed couch), and 1.5 mm (isocentric rotation). For intrafractional patient positioning, X-ray and AlignRT shifts were highly correlated (r=0.99), with the largest difference (mean ± SD) in the longitudinal direction (2.14 ± 1.02 mm). For interfractional breast surface variation and absolute positioning, there were still larger disagreements between the two modalities due to different focus on anatomical landmarks, and 95% of the data lie within 5mm with some outliers at 7 mm–9 mm. For multi-isocenter shifts, the difference was 1 ± 0.56 mm over an 11 cm shift in longitudinal direction. For couch rotation study, the differences was 1.36 ± 1.0 mm in vertical direction, 3.04 ± 2.11 mm in longitudinal direction, and 2.10 ± 1.66 mm in lateral direction, with all rotation differences < 1.5 degree. Conclusion: Surface imaging is promising for intrafractional treatment application in proton therapy to reduce X-ray frequency. However the interfractional discrepancy between the X-ray and SI requires future validation.

60 APPLIED LIFE SCIENCES↗

SU-F-T-505: A Novel Approach for Sparing Critical Organs at Risk for Cancer Patients Undergoing Radiation Oncology Treatments

Purpose: A major goal of an effective radiation treatment plan is to deliver the maximum dose to the tumor while minimizing radiation exposure to the surrounding normal structures. For example, due to the radiation exposure to neighboring critical structures during prostate cancer treatment, a significant increase in cancer risk was observed for the bladder (77%) and the rectum (105%) over the following decade. Consequently, an effective treatment plan necessitates limiting the exposure to such organs which can best be achieved by physically displacing the organ at-risk. The goal of this study is to present a prototype for an organ re-positioner device designed and fabricated to physically move the rectum away from the path of radiation beam during external beam and brachytherapy treatments. This device affords patient comfort and provides a fully controlled motion to safely relocate the rectum during treatment. Methods: The NiTi shape memory alloy was designed and optimized for manufacturing a rectal re-positioner device through cooling and heating the core alloy for its shaping. This has been achieved through a prototyped custom designed electronic circuit in order to induce the reversible austenitic transformation and was tested rigorously to ensure the integrity of the actuated motion in displacement of the target anatomy. Results: The desirable NiTi shape-setting was configured for easy insertion and based on anatomical constraint. When the final prototype was evaluated, accuracy and precision of the maximum displacement and temperature changes revealed that the device could safely be used within the target anatomy. Conclusion: The organ re-positioner device is a promising tool that can be implemented in clinical setting. It provides a controlled and safe displacement of the delicate organ(s) at risk. The location of the organ being treated could also be identified using conventional onboard imaging devices or MV imaging available on-board most modern clinical accelerators.

60 APPLIED LIFE SCIENCES↗

A Genome-Scale Atlas Reveals Complex Interplay of Transcription and Translation in an Archaeon

The scale of post-transcriptional regulation and the implications of its interplay with other forms of regulation in environmental acclimation are underexplored for organisms of the domain Archaea. Here, we have investigated the scale of post-transcriptional regulation in the extremely halophilic archaeon Halobacterium salinarum NRC-1 by integrating the transcriptome-wide locations of transcript processing sites (TPSs) and SmAP1 binding, the genome-wide locations of antisense RNAs (asRNAs), and the consequences of RNase_2099C knockout on the differential expression of all genes. This integrated analysis has discovered that 54% of all protein-coding genes in the genome of this haloarchaeon are likely targeted by multiple mechanisms for putative post-transcriptional processing and regulation, with about 20% of genes likely being regulated by combinatorial schemes involving SmAP1, asRNAs, and RNase_2099C. Comparative analysis of mRNA levels (transcriptome sequencing [RNA-Seq]) and protein levels (sequential window acquisition of all theoretical fragment ion spectra mass spectrometry [SWATH-MS]) for 2,579 genes over four phases of batch culture growth in complex medium generated additional evidence for the conditional post-transcriptional regulation of 7% of all protein-coding genes. We demonstrate that post-transcriptional regulation may act to fine-tune specialized and rapid acclimation to stressful environments, e.g., as a switch to turn on gas vesicle biogenesis to promote vertical relocation under anoxic conditions and modulate the frequency of transposition by insertion sequence (IS) elements of the IS200/IS605, IS4, and ISH3 families. Findings from this study are provided as an atlas in a public Web resource (https://halodata.systemsbiology.net).

59 BASIC BIOLOGICAL SCIENCES↗

Effect of iodine impurity on relaxation of photoexcited silver chloride

The time and temperature dependences of relaxation of excited AgCl and AgCl:I crystals is studied by the method of photostimulated flash of luminescence. The presence of iodine impurity in silver chloride gives rise to hole recombination (luminescence) centers and hole traps in the band gap. It is shown that the main contribution to the decrease in the concentration of electrons localized at deep traps is made by the recombination of electrons with holes released thermally from shallow localization levels (iodine-related centers). Estimation of activation energy for the relaxation process showed that these energies for the AgCl and AgCl:I samples under study are the same within the experimental error and are equal to E{sub rel1} = 0.01 {+-} 0.0005 eV for the initial stage of relaxation and E{sub rel2} = 0.09 {+-} 0.005 eV for the final state. This fact indicates that the majority of hole traps involved in the relaxation process in AgCl are related to iodine impurity. In the course of thermal relaxation in AgCl, relocalization of nonequilibrium charge carriers from shallow levels to deep levels is observed. The depth of the corresponding trap is E{sub arl} = 0.174 {+-} 0.03 eV.

36 MATERIALS SCIENCE↗

On controlling the electronic states of shallow donors using a finite-size metal gate

The effect of an external electric field on the states of a shallow donor near a semiconductor surface is numerically simulated. A disk-shaped metal gate is considered as an electric-field source. The wavefunctions and energies of bound states are determined by the finite-element method. The critical characteristics of electron relocation between the donor and gate are determined for various gate diameters and boundary conditions, taking into account dielectric mismatch. The empirical dependences of these characteristics on the geometrical parameters and semiconductor properties are obtained. A simple trial function is proposed, which can be used to calculate the critical parameters using the Ritz variational method.

36 MATERIALS SCIENCE↗