Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Readout electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Exploring Novel Technologies for Particle Tracking in Gas TPCs (Final Technical Report)

This report provides the final results from R&D on a novel 2D readout for a time projection chamber (TPC), which operates with negative-ion drift. The readout consists of two gas electron multiplier (GEM) devices places at an angle with respect to each other. The 2D range of particles interacting in the TPC is reconstructed using pulse-shape timing only. Due to the low diffusion and drift speeds of the negative-ions carrying the track information to the anode, the track resolution is <200 microns. Acquiring this level of resolution for short, low energy particle tracks in a standard TPC would require a fine granularity strip or pixel readout with many 1000s of electronic channels. With this novel readout, only two channels are needed. Our results showed that the concept is fundamentally sound. We found a number of issues related to how well the timing signals are determined from the pulse waveforms. Solutions for these had to be left for future R&D.

47 OTHER INSTRUMENTATION↗

Test beam measurement of ams H35 HV-CMOS capacitively coupled pixel sensor prototypes with high-resistivity substrate

In the context of the studies of the ATLAS High Luminosity LHC programme, radiation tolerant pixel detectors in CMOS technologies are investigated. To evaluate the effects of substrate resistivity on CMOS sensor performance, the H35DEMO demonstrator, containing different diode and amplifier designs, was produced in ams H35 HV-CMOS technology using four different substrate resistivities spanning from 80 cm to 1000 cm. A glueing process using a high-precision flip-chip machine was developed in order to capacitively couple the sensors to FE-I4 Readout ASIC using a thin layer of epoxy glue with good uniformity over a large surface. The resulting assemblies were measured in beam test at the Fermilab Test Beam Facilities with 120 GeV protons and CERN SPS H8 beamline using 180 GeV pions. Furthermore, the in-time efficiency and tracking properties measured for the different sensor types are shown to be compatible with the ATLAS ITk requirements for its pixel sensors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of a gigabit transceiver for the ATLAS inner tracker pixel detector readout upgrade

We present a gigabit transceiver prototype Application Specific Integrated Circuit (ASIC), GBCR, for the ATLAS Inner Tracker (ITk) Pixel detector readout upgrade. GBCR is designed in a 65-nm CMOS technology and consists of four upstream receiver channels, a downstream transmitter channel, and an Inter-Integrated Circuit (I2C) slave. The upstream channels receive the data at 5.12 Gbps passing through 5-meter 34-American Wire Gauge (AWG) Twin-axial (Twinax) cables, equalize and retime them with a recovered clock, and then drive an optical transmitter. The downstream channel receives the data at 2.56 Gbps from an optical receiver and drives the cable as same as the upstream channels. The jitter of the upstream channel output is measured to be 35 ps (peak-peak) when the Clock-Data Recovery (CDR) module is turned on and the jitter of the downstream channel output after the cable is 138 ps (peak-peak). The power consumption of each upstream channel is 72 mW when the CDR module is turned on and the downstream channel consumes 27 mW. GBCR survives the total ionizing dose of 200 kGy.

47 OTHER INSTRUMENTATION↗

High spatial resolution direct conversion amorphous selenium X-ray detectors with monolithically integrated CMOS readout

Recent progress in the field of micron-scale spatial resolution direct conversion X-ray detectors for high-energy synchrotron light sources serve applications ranging from nondestructive and noninvasive microscopy techniques which provide insight into the structure and morphology of crystals, to medical diagnostic measurement devices. Amorphous selenium ( a -Se) as a wide-bandgap thermally evaporated photoconductor exhibits ultra-low thermal generation rates for dark carriers and has been extensively used in X-ray medical imaging. Being an amorphous material, it can further be deposited over large areas at room temperatures and at substantially lower costs as compared to crystalline semiconductors. Here, to address the demands for a high-energy and high spatial resolution X-ray detector for synchrotron light source applications, we have thermally evaporated a -Se on a Mixed-Mode Pixel Array Detector (MM-PAD) Application Specific Integrated Circuit (ASIC). The ASIC format consists of 128 × 128 square pixels each 150 μm on a side. A 200 μm a -Se layer was directly deposited on the ASIC followed by a metal top electrode. The completed detector assembly was tested with 45 kV Ag and 23 kV Cu X-ray tube sources. The detector fabrication, performances, Modulation Transfer Function (MTF) measurements, and simulations are reported.

36 MATERIALS SCIENCE↗

Deep Learning Approach for High-accuracy Electron Counting of Monolithic Active Pixel Sensor-type Direct Electron Detectors at Increased Electron Dose

Abstract Electron counting can be performed algorithmically for monolithic active pixel sensor direct electron detectors to eliminate readout noise and Landau noise arising from the variability in the amount of deposited energy for each electron. Errors in existing counting algorithms include mistakenly counting a multielectron strike as a single electron event, and inaccurately locating the incident position of the electron due to lateral spread of deposited energy and dark noise. Here, we report a supervised deep learning (DL) approach based on Faster region-based convolutional neural network (R-CNN) to recognize single electron events at varying electron doses and voltages. The DL approach shows high accuracy according to the near-ideal modulation transfer function (MTF) and detector quantum efficiency for sparse images. It predicts, on average, 0.47 pixel deviation from the incident positions for 200 kV electrons versus 0.59 pixel using the conventional counting method. The DL approach also shows better robustness against coincidence loss as the electron dose increases, maintaining the MTF at half Nyquist frequency above 0.83 as the electron density increases to 0.06 e−/pixel. Thus, the DL model extends the advantages of counting analysis to higher dose rates than conventional methods.

Materials Science↗

Commercial and Cost Effective Production of Two-Dimensional Read-Out Boards for Sub-Atomic Particle Detectors

We report results from research aimed at developing and demonstrating production of 2-D readout structures for GEM (Gas Electron Multiplier) charged particle tracking chambers at Tech-Etch. Readout boards of two types, bi-planar and single plane, were fabricated and evaluated. The results show that Tech-Etch can produce suitable boards of either type however the single plane board has a number of advantages both in production and use that will likely make it the preferred choice for GEM tracking chambers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commercial and Cost Effective Production of Two-Dimensional Read-Out Boards for Sub-Atomic Particle Detectors

Tech-Etch has considerable experience in numerous related high precision etched Kapton® products including production of GEM foils. The required precision and production process for 2-D readout boards is similar to that developed for GEM foil production. Additionally, Tech-Etch has strong ties with several research institutions (namely Brookhaven National Laboratory, MIT and Yale University) that can help design and evaluate the performance of the readout boards produced at Tech-Etch. Since Tech-Etch is a small company, it also has the capability to produce a large variety of part configurations, optimized for a particular customer's requirements. We report results from research aimed at developing and demonstrating production of 2-D readout structures for GEM (Gas Electron Multiplier) charged particle tracking chambers at Tech-Etch. Readout boards of two types, bi-planar and single plane, were fabricated and evaluated. The results show that Tech-Etch can produce suitable boards of either type however the single plane board has a number of advantages both in production and use that will likely make it the preferred choice for GEM tracking chambers.

(cylindrical↗

Radiation Tolerance of 65nm CMOS Transistors

We report on the effects of ionizing radiation on 65 nm CMOS transistors held at approximately -20°C during irradiation. The pattern of damage observed after a total dose of 1 Grad is similar to damage reported in room temperature exposures, but we observe less damage than was observed at room temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The AMACStar ASIC for the HL-LHC ATLAS ITk Strip detector: design, verification, testing, and quality assurance

For the high-luminosity upgrade to the LHC (HL-LHC), the ATLAS detector at CERN requires an all-new inner detector, the Inner Tracker (ITk). The ITk Strip subdetector is made up of silicon modules, which include three types of radiation-hard ASICs. One of these is the Autonomous Monitor and Control (AMAC). The AMAC is manufactured by Global Foundries using 130 nm CMOS8RF DM technology and is approximately 3 by 5 mm in size. This ASIC autonomously monitors the temperatures, voltages, and currents in the module components while controlling critical values in order to prevent these quantities from reaching dangerous levels. The final design, AMACStar, was verified, tested, and ensured to perform all necessary functions. A quality control procedure using an in-house probe station set-up was developed in order to ensure that every individual chip on each wafer of AMACStars required by the ITk Strip project met performance requirements. The average per wafer yield of usable AMACStars is 92.33%, exceeding the design-specific 90% yield estimated for project costing. This estimate was based on actual yields for similar designs in this process.

Analogue electronic circuits↗

Event driven readout architecture with non-priority arbitration for radiation detectors

A novel event driven readout architecture, EDWARD (Event Driven with Access and 8 Reset Decoder) architecture, for highly granular pixel detectors is presented. It incorporates, inter alia, an asynchronous arbitration tree based on Seitz' arbiters, removing the need for an imposed prioritization scheme. It also provides protection against glitches during readout. The system allows not only reading pixel activities, but also retrieving additional data, both analog and digital, from the pixels. A novel in-channel logic allows the entire readout process to be split into consecutive phases for additional flexibility. All operations are controlled by only one edge of the clock signal, seen as an acknowledge token, so there is no dead time between readouts.

47 OTHER INSTRUMENTATION↗

Spectral perturbations from silicon diode detector encapsulation and shielding in photon fields

Purpose: Silicon diodes are widely used as detectors for relative dose measurements in radiotherapy. The common manufacturing practice is to encapsulate the diodes in plastic for protection and to facilitate mounting in scanning devices. Diodes intended for use in photon fields commonly also have a shield of a high atomic number material (usually tungsten) integrated into the encapsulation to selectively absorb low-energy photons to which silicon diodes would otherwise over-response. However, new response models based on cavity theories and spectra calculations have been proposed for direct correction of the readout from unshielded (e.g., ''electron'') diodes used in photon fields. This raises the question whether it is correct to assume that the spectrum in a water phantom at the location of the detector cavity is not perturbed by the detector encapsulation materials. The aim of this work is to investigate the spectral effects of typical encapsulations, including shielding, used for clinical diodes. Methods: The effects of detector encapsulation of an unshielded and a shielded commercial diode on the spectra at the detector cavity location are studied through Monte Carlo simulations with PENELOPE-2005. Variance reduction based on correlated sampling is applied to reduce the CPU time needed for the simulations. Results: The use of correlated sampling is found to be efficient and to not introduce any significant bias to the results. Compared to reference spectra calculated in water, the encapsulation for an unshielded diode is demonstrated to not perturb the spectrum, while a tungsten shielded diode caused not only the desired decrease in low-energy scattered photons but also a large increase of the primary electron fluence. Measurements with a shielded diode in a 6 MV photon beam proved that the shielding does not completely remove the field-size dependence of the detector response caused by the over-response from low-energy photons. Response factors of a properly corrected unshielded diode were shown to give comparable, or better, results than the traditionally used shielded diode. Conclusions: Spectra calculated for photon fields in water can be directly used for modeling the response of unshielded silicon diodes with plastic encapsulations. Unshielded diodes used together with appropriate corrections can replace shielded diodes in photon dose measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle identification studies with a full-size 4-GEM prototype for the ALICE TPC upgrade

We present that a large Time Projection Chamber is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019/20, the LHC will deliver Pb beams colliding at an interaction rate of about 50 kHz, which is about a factor of 50 above the present readout rate of the TPC. This will result in a significant improvement on the sensitivity to rare probes that are considered key observables to characterize the QCD matter created in such collisions. In order to make full use of this luminosity, the currently used gated Multi-Wire Proportional Chambers will be replaced. The upgrade relies on continuously operated readout detectors employing Gas Electron Multiplier technology to retain the performance in terms of particle identification via the measurement of the specific energy loss by ionization d/d. A full-size readout chamber prototype was assembled in 2014 featuring a stack of four GEM foils as an amplification stage. The performance of the prototype was evaluated in a test beam campaign at the CERN PS. Finally, the d/d resolution complies with both the performance of the currently operated MWPC-based readout chambers and the challenging requirements of the ALICE TPC upgrade program. Detailed simulations of the readout system are able to reproduce the data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The upgrade of the CMS hadron calorimeter with silicon photomultipliers

The upgrade of the hadron calorimeter of the CMS experiment at the CERN Large Hadron Collider is currently underway. The endcap sections will be upgraded in the winter of 2016–2017 and the barrel sections during the second LHC long shutdown in 2019. The existing photosensors will be replaced with about 16 000 new silicon photomultipliers (SiPMs), resulting in the first large installation of SiPMs in a radiation environment. All associated front-end electronics will also be upgraded. Here, this paper discusses the motivation for the upgrade and provides a description 17 of the new system, including the SiPMs with associated control electronics and the front-end readout cards.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new ATLAS muon CSC readout system with system on chip technology on ATCA platform

The ATLAS muon Cathode Strip Chamber (CSC) backend readout system has been upgraded during the LHC 2013-2015 shutdown to be able to handle the higher Level-1 trigger rate of 100 kHz and the higher occupancy at Run-2 luminosity. The readout design is based on the Reconfigurable Cluster Element (RCE) concept for high bandwidth generic DAQ implemented on the Advanced Telecommunication Computing Architecture (ATCA) platform. The RCE design is based on the new System on Chip XILINX ZYNQ series with a processor-centric architecture with ARM processor embedded in FPGA fabric and high speed I/O resources. Together with auxiliary memories, all of these components form a versatile DAQ building block that can host applications tapping into both software and firmware resources. The Cluster on Board (COB) ATCA carrier hosts RCE mezzanines and an embedded Fulcrum network switch to form an online DAQ processing cluster. More compact firmware solutions on the ZYNQ for high speed input and output fiberoptic links and TTC allowed the full system of 320 input links from the 32 chambers to be processed by 6 COBs in one ATCA shelf. The full system was installed in September 2014. In conclusion, we will present the RCE/COB design concept, the firmware and software processing architecture, and the experience from the intense commissioning for LHC Run 2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Fidelity Single-Shot Readout for a Spin Qubit via an Enhanced Latching Mechanism

The readout of semiconductor spin qubits based on spin blockade is fast but suffers from a small charge signal. Previous work suggested large benefits from additional charge mapping processes; however, uncertainties remain about the underlying mechanisms and achievable fidelity. In this work, we study the single-shot fidelity and limiting mechanisms for two variations of an enhanced latching readout. We achieve average single-shot readout fidelities greater than 99.3% and 99.86% for the conventional and enhanced readout, respectively, the latter being the highest to date for spin blockade. The signal amplitude is enhanced to a full one-electron signal while preserving the readout speed. Furthermore, layout constraints are relaxed because the charge sensor signal is no longer dependent on being aligned with the conventional (2,0)–(1,1) charge dipole. Silicon donor-quantum-dot qubits are used for this study, for which the dipole insensitivity substantially relaxes donor placement requirements. One of the readout variations also benefits from a parametric lifetime enhancement by replacing the spin-relaxation process with a charge-metastable one. This provides opportunities to further increase the fidelity. The relaxation mechanisms in the different regimes are investigated. This work demonstrates a readout that is fast, has a one-electron signal, and results in higher fidelity. As a result, it further predicts that going beyond 99.9% fidelity in a few microseconds of measurement time is within reach.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Building Towards Discovery: Preparing for New Physics at the LHC [Final papers]

Particle physics today is at a crossroads. The Standard Model (SM) has survived four decades of experimental scrutiny and spurred multiple landmark discoveries, culminating with the 2012 discovery of the Higgs boson at the Large Hadron Collider (LHC). Yet we know that this model is incomplete. We live in a universe dominated by matter and energy unaccounted for by the SM– and the Higgs boson itself is improbably light. It falls to the current generation of high-energy physicists to go beyond the model and enter a new era of discovery. Andeen is leading a new research group at the University of Texas at Austin (UT-Austin) that is endeavoring to reveal novel physical phenomena through the discovery of new particles with the ATLAS detector at the LHC. A key element of our experience thus far has been collaborating closely with theorists to identify both interesting new physics models. In addition we work closely with electrical engineers in detector development. Our approach is therefore unique in its integration of theory, analysis and instrumentation, and is encapsulated in a three-pronged strategy. First is the essential task of analyzing our rapidly expanding dataset. I am directing my group in searches for vector-like quarks (VLQs). Should they exist, these hypothetical particles would indicate physics scenarios beyond the SM. Experimental constraints suggest VLQs decay preferentially to a third generation quark and a Higgs, W or Z boson. Today at 13 TeV, both multi-lepton (electron and muon) and jet substructure signatures are sensitive to identifying the VLQ decay products. The large Run 2 dataset (collected through 2018) of up to 150 fb -1 will allow us to simultaneously use multi-lepton signatures with jet-substructure in searches for new physics. UT-Austin is well positioned to be a leader in this area. Prof. P. Onyisi’s postdoctoral researchers and graduate students are searching for ttH signatures in three- and four-lepton channels and we benefit from their experience. We are also aided by the availability of the Texas Advanced Computing Center, which provides us with easy access to several high performance computing (HPC) systems. My previous experience in VLQ searches propels the work today. I have published both the first investigation into the single production of top partners (signatures of composite Higgs Models) of any LHC experiment 1 as well as one of the first analyses utilizing jet-substructure techniques to search for the single production of vector-like quarks. 2 Adding to this is my group’s work with the Liquid Argon (LAr) calorimeter, the primary instrument we use in detecting electrons. Second, my group is contributing to the operations of the LAr calorimeter while preparing to install and commission new electronic hardware (the Phase 1 upgrade) to this crucial component of the ATLAS detector. I have played a leading role in the development of a critical, radiation-hard, high-speed Analog-to-Digital Convertor (ADC) that is essential inselecting data collected by the LAr calorimeter. 3 This upgrade will improve the e!ciency with which we can select events in our detector. Postdoctoral researcher N. Nikiforou (based at CERN May 2016 onward) and graduate students (one based at CERN from the start of 2018 onward, with one additional graduate students from summer 2018) are growing our already deep experience in the operation of the LAr calorimeter to prepare for installation and commissioning of the new trigger readout in 2018-2019. My group will then be positioned to be the first to exploit the potential of the improved triggers in our multi-lepton searches for new physics. Third, a suite of preparations for a major detector upgrade, scheduled to be completed in 2024, are underway. My group is building hardware that will improve the electronic readout of the ATLAS detector. I am partnering with a group in the Electrical and Computer Engineering (ECE) Department at UT-Austin (Prof. N. Sun) to employ his work at the cutting edge of ADC research. We will support an ECE grad student for the layout of this design, and collaborate with engineering groups at Nevis Laboratory and the Electrical Engineering Department (Prof. P. Kinget) at Columbia University to integrate our ADC with gain selection circuits. We will provide this critical component of the ASIC at the challenging boundary of the analog and digital signals in the LAr calorimeter readout chain. Furthermore UT-Austin will lead the testing of this device during development and production (approximately 55,000 four-channel chips). This effort compliments my work as the deliverables manager for the LAr front-end ASICs for the US ATLAS HL-LHC project and strengthens the US commitment to that upgrade.In so doing, my group at the UT-Austin will be at the forefront of efforts to probe the structure of the universe to an unmatched degree both at the current LHC and with its future upgrades. Through both the ongoing analysis of data at the ATLAS detector and improvements to the detector itself, an answer to what lies beyond the SM may come within our grasp. My background in instrumentation and analysis allows my group to establish a singular research effort on the ATLAS experiment. In addition to answering fundamental questions about the subatomic world, the technologies developed could advance the broader scientific community and result in valuable spin-offs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A readout digitization system for the ATLAS muon spectrometer phase-I tRPC trigger upgrade

The front-end digitization electronics for thin-Resistive Plate Chambers to be installed as part of the ATLAS Muon Spectrometer Phase-I upgrade project is described. Here, the design is based on the CERN HPTDC and GOL chips. In this paper, the design of the digitization system is presented, including power, connection interfaces to front-end amplifier-shaper-discriminator board and to the low level trigger processor board. System performance tests were conducted and validated with a prototype which includes one HPTDC/GOL pair.

Digital electronic circuits↗

Large Time Projection Chambers for Rare Event Detection

The Time Projection Chamber (TPC) concept [add ref to TPC section] has been applied to many projects outside of particle physics and the accelerator based experiments where it was initially developed. TPCs in non-accelerator particle physics experiments are principally focused on rare event detection (e.g. neutrino and darkmater experiments) and the physics of these experiments can place dramatically different constraints on the TPC design (only extensions to the traditional TPCs are discussed here). The drift gas, or liquid, is usually the target or matter under observation and due to very low signal rates a TPC with the largest active mass is desired. The large mass complicates particle tracking of short and sometimes very low energy particles. Other special design issues include, efficient light collection, background rejection, internal triggering and optimal energy resolution. Backgrounds from gamma-rays and neutrons are significant design issues in the construction of these TPCs. They are generally placed deep underground to shield from cosmogenic particles and surrounded with shielding to reduce radiation from the local surroundings. The construction materials have to be carefully screened for radiopurity as they are in close contact with the active mass and can be a signification source of background events. The TPC excels in reducing this internal background because the mass inside the fieldcage forms one monolithic volume from which fiducial cuts can be made ex post facto to isolate quiet drift mass, and can be circulated and purified to a very high level. Self shielding in these large mass systems can be significant and the effect improves with density. The liquid phase TPC can obtain a high density at low pressure which results in very good self-shielding and compact installation with a lightweight containment. The down sides are the need for cryogenics, slower charge drift, tracks shorter than the typical electron diffusion, lower energy resolution (e.g. xenon) and limited charge readout options. Slower charge drift requires long electron lifetimes placing strict limits on the oxygen and other impurities with high electron affinity. A significant variation of the liquid phase TPC, that improves the charge readout, is the dual-phase TPC where a gas phase layer is formed above the liquid into which the drifting electrons are extracted and amplified, typically with electroluminescence. The successful transfer of electrons through the phase boundary requires careful control of its position and setting up an appropriate electric field. A high pressure gas phase TPC has no cryogenics and density is easily optimized for the signal, but a large heavy pressure vessel is required. Although shelf shielding is reduced, it can in some cases approach that of the liquid phase; in xenon at 50atm the density is about half that of water or about 1/6 of liquid xenon. A significant feature of high pressure xenon gas is the energy resolution. Below a density of about 0.5g/cc the intrinsic resolution is only a few times that of high purity germanium. A neutrino-less double beta decay (0{nu}2{beta}) TPC operated below this density limit could enjoy excellent energy resolution and maintain particle tracking for background rejection. An observable interaction with the TPC results in a charged particle that travels in the drift matter exciting and ionizing the atoms until the initial energy is converted into ionization, scintillation, or heat with relatively large fluctuations around a mean distribution. Rare event TPCs can be designed to detect scintillation light as well as charge to exploit the anti-correlation to improve energy resolution and/or signal to noise. An electric drift field separates the electrons and positive ions from the ionization although the separation is not complete and some electrons are captured, exciting atoms and releasing more light than the primary excitation alone. The average partition between the scintillation and ionization can be manipulated to increase the ionization (at a loss of scintillation) by a number of methods such as, increasing the strength of the electric field up to a saturation of the ionization yield, increasing the temperature to enhance the diffusion of the ionized electrons, and adding dopants such as triethylamine that can be photoionized by the scintillation photons releasing more ionization. Scintillation light is typically collected with photomultiplier tubes (PMTs) and avalanche photo diodes (APDs) although any fast (compared to the ionization drift speed) light collector capable of detecting the typically UV photons, maintaining high radiopurity and perhaps withstanding pressure would work. CCDs are slow and therefore only record 2 dimensions integrating over the time direction, some of which can be recovered with a few PMTs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗