Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Readout electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Portable Fourier Transform Spectroscopy for Analysis of Surface Contamination and Quality Control

Progress has been made into adapting and enhancing a commercially available infrared spectrometer for the development of a handheld device for in-field measurements of the chemical composition of various samples of materials. The intent is to duplicate the functionality of a benchtop Fourier transform infrared spectrometer (FTIR) within the compactness of a handheld instrument with significantly improved spectral responsivity. Existing commercial technology, like the deuterated L-alanine triglycine sulfide detectors (DLATGS), is capable of sensitive in-field chemical analysis. This proposed approach compares several subsystem elements of the FTIR inside of the commercial, non-benchtop system to the commercial benchtop systems. These subsystem elements are the detector, the preamplifier and associated electronics of the detector, the interferometer, associated readout parameters, and cooling. This effort will examine these different detector subsystem elements to look for limitations in each. These limitations will be explored collaboratively with the commercial provider, and will be prioritized to meet the deliverable objectives. The tool design will be that of a handheld gun containing the IR filament source and associated optics. It will operate in a point-and-shoot manner, pointing the source and optics at the sample under test and capturing the reflected response of the material in the same handheld gun. Data will be captured via the gun and ported to a laptop.

Pugel, Diane↗

Directional detection of dark matter using solid-state quantum sensing

Next-generation dark matter (DM) detectors searching for weakly interacting massive particles (WIMPs) will be sensitive to coherent scattering from solar neutrinos, demanding an efficient background-signal discrimination tool. Directional detectors improve sensitivity to WIMP DM despite the irreducible neutrino background. Wide-bandgap semiconductors offer a path to directional detection in a high-density target material. A detector of this type operates in a hybrid mode. Here, the WIMP or neutrino-induced nuclear recoil is detected using real-time charge, phonon, or photon collection. The directional signal, however, is imprinted as a durable sub-micron damage track in the lattice structure. This directional signal can be read out by a variety of atomic physics techniques, from point defect quantum sensing to x-ray microscopy. In this Review, we present the detector principle as well as the status of the experimental techniques required for directional readout of nuclear recoil tracks. Specifically, we focus on diamond as a target material; it is both a leading platform for emerging quantum technologies and a promising component of next-generation semiconductor electronics. Based on the development and demonstration of directional readout in diamond over the next decade, a future WIMP detector will leverage or motivate advances in multiple disciplines toward precision dark matter and neutrino physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Mu2e Digitizer ReAdout Controller (DiRAC): characterization and radiation hardness

The Mu2e experiment at Fermilab will search for the neutrino-less coherent conversion of a muon into an electron in the field of a nucleus. Mu2e detectors comprise a straw tracker, an electromagnetic calorimeter and a veto for cosmic rays. The calorimeter employs 1348 Cesium Iodide crystals readout by silicon photo-multipliers and fast front-end, and digitization electronics. The digitization board is named DiRAC (Digitizer ReAdout Controller) and 140 cards are needed for the readout of the full calorimeter. The DiRACs are hosted in crates located on the external surface of calorimeter disks, inside the detector solenoid cryostat and must sustain very high radiation and magnetic field so it was necessary to fully qualify it. Several version of prototypes were validated for operation in a high-vacuum (10−4 Torr) and under a 1T magnetic field. An extensive radiation hardness qualification campaign, carried out with photons, 14 MeV neutron beams, and 200 MeV protons, certified the DiRAC design to sustain doses up to 12 Krad, neutron fluences up to ∼ 1011 1 MeV neq/cm2, and very low occurrences of single-event effects. The qualification campaigns and quality assurance procedures will be reviewed.

43 PARTICLE ACCELERATORS↗

First results from a high-frame-rate, multi-GHz ionizing particle detection system geared toward accelerator diagnostic applications

An integrated detection system, consists of a thin diamond sensor incorporated into a compact signal loop, coupled in turn to an application-specific integrated circuit readout chip, has been tested for the first time, using ps-duration electron pulses from the Next Linear Collider Test Accelerator at the SLAC National Accelerator Laboratory. For readout frame rates as high as 120 kHz, the detection system is shown to achieve a linear dynamic range of 10 3 and a bandwidth of 4–5 GHz, with no ringing seen on the tail of the output pulse. These results represent the best-performing multi-GHz ionizing particle detection system achieved to date.

Ferezghi, Mohammadreza Mohseni [University of Cali↗

Commissioning of an MPGD-based Drift Chamber for Heavy-ion Tracking in FRIB's Sweeper magnet system

A newly developed drift chamber equipped with an innovative hybrid Micro-Pattern Gaseous Detector based readout was commissioned at FRIB. The detector consists of a Multi-layer Thick Gas Electron Multiplier (M-THGEM) mounted over a high-granularity, position-sensitive readout board. Denoted as the Micro-Pattern Drift Chamber (MPDC), the new device is used to provide tracking capability as part of the detectors of the Sweeper magnet system for neutron-invariant-mass spectrometry at the Facility for Rare Isotope Beams (FRIB). The localization of impinging ions in a 30 × 30 cm 2 drift area is derived by processing the charge-avalanche distribution induced on the segmented readout board. The signals induced on the readout pads are processed by a compact, multi-channel Data Acquisition System (DAQ) based on the Scalable Readout System (SRS). To facilitate synchronization with other detector systems of the Sweeper magnet system, the SRS has been configured to accept an external trigger.

Gaseous detectors↗

Enhancing Neutrino Event Reconstruction with Pixel-Based 3D Readout for Liquid Argon Time Projection Chambers

In this paper we explore the potential improvements in neutrino event reconstruction that a 3D pixelated readout could offer over a 2D projective wire readout for liquid argon time projection chambers. We simulate and study events in two generic, idealized detector configurations for these two designs, classifying events in each sample with deep convolutional neural networks to compare the best 2D results to the best 3D results. In almost all cases we find that the 3D readout provides better reconstruction efficiency and purity than the 2D projective wire readout, with the advantages of 3D being particularly evident in more complex topologies, such as electron neutrino charged current events. We conclude that the use of a 3D pixelated detector could significantly enhance the reach and impact of future liquid argon TPC experiments physics program, such as DUNE.

Adams, C↗

Novel Liquid Argon Time-Projection Chamber Readouts

Liquid argon time-projection chambers (LArTPCs) have become a prominent tool for experiments in particle physics. Recent years have yielded significant advances in the techniques used to capture the signals generated by these cryogenic detectors. This article summarizes these novel developments for detection of ionization electrons and scintillation photons in LArTPCs. New methods to capture ionization signals address the challenges of scaling traditional techniques to the large scales necessary for future experiments. Pixelated readouts improve signal fidelity and expand the applicability of LArTPCs to higher-rate environments. Methods that leverage amplification in argon enable measurements in the keV regime and below. Techniques to enhance collection of argon scintillation photons improve calorimetry and expand the physics program for very large detectors. Future efforts aim to demonstrate systems for the combined detection of both electrons and photons.

43 PARTICLE ACCELERATORS↗

Electronic interactions in Dirac fluids visualized by nano-terahertz spacetime interference of electron-photon quasiparticles

Ultraclean graphene at charge neutrality hosts a quantum critical Dirac fluid of interacting electrons and holes. Interactions profoundly affect the charge dynamics of graphene, which is encoded in the properties of its electron-photon collective modes: surface plasmon polaritons (SPPs). Here, we show that polaritonic interference patterns are particularly well suited to unveil the interactions in Dirac fluids by tracking polaritonic interference in time at temporal scales commensurate with the electronic scattering. Spacetime SPP interference patterns recorded in terahertz (THz) frequency range provided unobstructed readouts of the group velocity and lifetime of polariton that can be directly mapped onto the electronic spectral weight and the relaxation rate. Our data uncovered prominent departures of the electron dynamics from the predictions of the conventional Fermi-liquid theory. The deviations are particularly strong when the densities of electrons and holes are approximately equal. The proposed spacetime imaging methodology can be broadly applied to probe the electrodynamics of quantum materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A High-Speed, Event-Driven, Active Pixel Sensor Readout for Photon-Counting Microchannel Plate Detectors

Silicon array readouts for microchannel plate intensifiers offer several attractive features. In this class of detector, the electron cloud output of the MCP intensifier is converted to visible light by a phosphor; that light is then fiber-optically coupled to the silicon array. In photon-counting mode, the resulting light splashes on the silicon array are recognized and centroided to fractional pixel accuracy by off-chip electronics. This process can result in very high (MCP-limited) spatial resolution for the readout while operating at a modest MCP gain (desirable for dynamic range and long term stability). The principal limitation of intensified CCD systems of this type is their severely limited local dynamic range, as accurate photon counting is achieved only if there are not overlapping event splashes within the frame time of the device. This problem can be ameliorated somewhat by processing events only in pre-selected windows of interest or by using an addressable charge injection device (CID) for the readout array. We are currently pursuing the development of an intriguing alternative readout concept based on using an event-driven CMOS Active Pixel Sensor. APS technology permits the incorporation of discriminator circuitry within each pixel. When coupled with suitable CMOS logic outside the array area, the discriminator circuitry can be used to trigger the readout of small sub-array windows only when and where an event splash has been detected, completely eliminating the local dynamic range problem, while achieving a high global count rate capability and maintaining high spatial resolution. We elaborate on this concept and present our progress toward implementing an event-driven APS readout.

Kimble, Randy A.↗

Sixteen multiple-amplifier sensing charge-coupled devices and characterization techniques targeting the next generation of astronomical instruments

We present a candidate sensor for future spectroscopic applications, such as a Stage-5 Spectroscopic Survey Experiment or the Habitable Worlds Observatory. This type of charge-coupled device (CCD) sensor features multiple in-line amplifiers at its output stage allowing multiple measurements of the same charge packet, either in each amplifier or in the different amplifiers. Recently, the operation of an eight-amplifier sensor has been experimentally demonstrated, and we present the operation of a 16-amplifier sensor. This new sensor enables a noise level of ∼1 erms− with a single sample per amplifier. In addition, it is shown that sub-electron noise can be achieved using multiple samples per amplifier. In addition to demonstrating the performance of the 16-amplifier sensor, we aim to create a framework for future analysis and performance optimization of this type of detectors. New models and techniques are presented to characterize specific parameters, which are absent in conventional CCDs and Skipper CCDs: charge transfer between amplifiers and independent and common noise in the amplifiers and their processing.

16 multiple-amplifer sensing CCD (MAS-CCD)↗

Evaluation of GaAs FETs for cryogenic readout

Low-frequency, low-noise, low-power cryogenic electronics to read out photodetectors is being investigated for the star-tracking telescope of the Gravity Probe B spacecraft. We report our initial findings from evaluating more than 20 types of GaAs FETs, both commercial and non-commercial, for this application. Most exhibit useable dc characteristics at cryogenic temperatures, although gate leakage and hysteretic effects (presumably due to charge trapping) could be troublesome. Low-frequency noise (based primarily on grounded-gate measurements) at 4 K is '1/f-like' and for the quietest GaAs FETs appears to be at least as low as the lowest noise values reported for Si MOSFETs at 4 K. Further investigation is needed in several areas.

Kirschman, Randall K.↗

The large-area hybrid-optics CLAS12 RICH: First years of data-taking

The CLAS12 deep-inelastic scattering experiment at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Lab conjugates luminosity and wide acceptance to study the 3D nucleon structure in the yet poorly explored valence region, and to perform precision measurements in hadron spectroscopy. A large area ring-imaging Cherenkov detector has been designed to achieve the required hadron identification in the momentum range from 3 GeV/c to 8 GeV/c, with the kaon rate about one order of magnitude lower than the rate of pions and protons. The adopted solution comprises aerogel radiator and composite mirrors in a novel hybrid optics design, where either direct or reflected light could be imaged in a high-packed and high-segmented photon detector. The first RICH module was assembled during the second half of 2017 and installed at the beginning of January 2018, in time for the start of the experiment. The second RICH module, planned with the goal to be ready for the beginning of the operation with polarized targets, has been timely built despite the complications caused by the pandemic crisis and successfully installed in June 2022. Finally, the detector performance is here discussed with emphasis on the operation and stability during the data-taking, calibration and alignment procedures, reconstruction and pattern recognition algorithms, and particle identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phonon-mediated quantum efficiency measurement in semiconductors

Accurate quantum efficiency measurement not only provides crucial information for the photovoltaic cell industry but also supports experiments aimed at directly detecting dark matter and elastic neutrino interactions. The dark matter direct searches paradigm has recently expanded to include particles with masses below 1,MeV/c2, where the expected signal in an electron–recoil interaction is approximately in the eV range, just above the energy gap for silicon and germanium. A robust calibration method for ionization signals in this lower energy region is essential. This paper presents a method for measuring quantum efficiency and yield (q/E) in semiconductors using phonon-mediated calorimetry. The Neganov–Trofimov–Luke phonon amplification method in low-temperature semiconductor crystals has been employed to indirectly measure ionization down to single-electron accuracy. Specifically, at zero bias, the phonon readout directly quantifies the total energy deposited within the detector, independent of the ionization yield. This eliminates a significant source of systematic uncertainty in quantum efficiency estimates associated with total energy uncertainty. The paper includes results from an updated ionization efficiency measurement in a germanium detector.

Physics↗

Multiplexing readout channels in proportional counters

Proportional counters are important instruments used in sensing hard x-rays. The possibility is described of doubling the number of readout channels in the detector without increasing the electronics needed to amplify channel signals. This suggests that it should be possible, conversely, to reduce the number of amplifiers, thereby reducing the weight and energy budget of the instrument. Various numerical multiplexing schemes are analyzed, and a computer program is presented that can reconstruct multiplexed channel outputs with very good accuracy.

Caristi, James↗

Characterization of Pixelated Cadmium-Zinc-Telluride Detectors for Astrophysical Applications

Comparisons of charge sharing and charge loss measurements between two pixelated Cadmium-Zinc-Telluride (CdZnTe) detectors are discussed. These properties along with the detector geometry help to define the limiting energy resolution and spatial resolution of the detector in question. The first detector consists of a 1-mm-thick piece of CdZnTe sputtered with a 4x4 array of pixels with pixel pitch of 750 microns (inter-pixel gap is 100 microns). Signal readout is via discrete ultra-low-noise preamplifiers, one for each of the 16 pixels. The second detector consists of a 2-mm-thick piece of CdZnTe sputtered with a 16x16 array of pixels with a pixel pitch of 300 microns (inter-pixel gap is 50 microns). This crystal is bonded to a custom-built readout chip (ASIC) providing all front-end electronics to each of the 256 independent pixels. These detectors act as precursors to that which will be used at the focal plane of the High Energy Replicated Optics (HERO) telescope currently being developed at Marshall Space Flight Center. With a telescope focal length of 6 meters, the detector needs to have a spatial resolution of around 200 microns in order to take full advantage of the HERO angular resolution. We discuss to what degree charge sharing will degrade energy resolution but will improve our spatial resolution through position interpolation.

Gaskin, Jessica↗

The MIGDAL experiment: Measuring a rare atomic process to aid the search for dark matter

We present the Migdal In Galactic Dark mAtter expLoration (MIGDAL) experiment aiming at the unambiguous observation and study of the so-called Migdal effect induced by fast-neutron scattering. It is hoped that this elusive atomic process can be exploited to enhance the reach of direct dark matter search experiments to lower masses, but it is still lacking experimental confirmation. Our goal is to detect the predicted atomic electron emission which is thought to accompany nuclear scattering with low, but calculable, probability, by deploying an Optical Time Projection Chamber filled with a low-pressure gas based on CF 4 . Initially, pure CF 4 will be used, and then in mixtures containing other elements employed by leading dark matter search technologies — including noble species, plus Si and Ge. High resolution track images generated by a Gas Electron Multiplier stack, together with timing information from scintillation and ionisation readout, will be used for 3D reconstruction of the characteristic event topology expected for this process — an arrangement of two tracks sharing a common vertex, with one belonging to a Migdal electron and the other to a nuclear recoil. Different energy-loss rate distributions along both tracks will be used as a powerful discrimination tool against background events. In this article we present the design of the experiment, informed by extensive particle and track simulations and detailed estimations of signal and background rates. In pure CF 4 we expect to observe 8.9 (29.3) Migdal events per calendar day of exposure to an intense D–D (D–T) neutron generator beam at the NILE facility located at the Rutherford Appleton Laboratory (UK). With our nominal assumptions, 5σ median discovery significance can be achieved in under one day with either generator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Space-Flight Compatible Room-Temperature Electronics for the Lynx X-Ray Microcalorimeter

We are studying the development of space-flight compatible room-temperature electronics for the Lynx x-ray microcalorimeter (LXM) of the Lynx mission. The baseline readout technique for the LXM is microwave SQUID multiplexing. The key modules at room temperature are the RF electronics module and the digital electronics and event processor (DEEP). The RF module functions as frequency converters and mainly consists of local oscillators and I/Q mixers. The DEEP performs demultiplexing and event processing, and mainly consists of field-programmable gate arrays, ADCs, and DACs. We designed the RF electronics and DEEP to be flight ready, and estimated the power, size, and mass of those modules. There are two boxes each for the RF electronics and DEEP for segmentation, and the sizes of the boxes are 13 in: × 13 in: × 9 in: for the RF electronics and 15.5 in: × 11.5 in: × 9.5 in: for the DEEP. The estimated masses are 25.1 kg∕box for the RF electronics box and 24.1 kg∕box for the DEEP box. The maximum operating power for the RF electronics is 141 W or 70.5 W∕box, and for the DEEP box is 615 W or 308 W∕box. The overall power for those modules is 756 W. We describe the detail of the designs as well as the approaches to the estimation of resources, sizes, masses, and powers.

Sakai, Kazuhiro↗