Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

The energy spectrum of cosmic ray electrons between 9 and 300 GeV

The high-energy cosmic-ray electron spectrum between 9 and 300 GeV has been measured using an instrument consisting of a combination of a transition-radiation detector and a shower detector. The instrument has been calibrated at accelerators over the energy range 5-300 GeV and has been exposed in a balloon flight for 9.3 sq m sr hr. The design of the instrument and the data analysis procedures are described. It is found that the electron spectrum is significantly steeper than the proton spectrum. If the spectrum is fitted to a single power law, a spectral index of 3.35 is obtained. This suggests the influence of radiative energy losses on galactic electrons at low energies. The results are interpreted in the context of the homogeneous model for galactic cosmic rays.

Prince, T. A.↗

A Search for Sterile Neutrino Dark Matter (Final Report)

Decades of dark matter searches with increasingly higher sensitivity have so far not been able to detect the most-favored hypothetical dark matter particles. This has increased interest in sterile neutrinos with masses in the kilo-electronvolt (keV) range as possible dark matter candidates. We have established a and new and world-leading approach to search for keV-scale sterile neutrinos with superconducting radiation detectors. For this, we have implanted radioactive beryllium-7 (Be-7) nuclei into our superconducting tunnel junction (STJ) detectors and measured the recoil energy of the lithium-7 (Li-7) daughter nucleus with high accuracy. If the associated electron neutrino wave function contains some admixture of a keV sterile flavor, the Li-7 recoil energy will be shifted and produce an additional peak in the spectrum whose energy depends on the sterile neutrino mass. While we have not observed any evidence for sterile neutrinos in these precision decay experiments, the experiment has increased the sensitivity of sterile neutrino searches by a factor of ~10 over competing approaches in the mass range from ~10 to ~800 keV. The next generation of STJ detectors that we have developed as part of this project will be able further increase the sensitivity of the sterile neutrino search by at least another two orders of magnitude.

42 ENGINEERING↗

Utilization of ACE nuclear data file toolkit ACEtk to calculate relative sensitivity coefficients of point-kinetics parameters

Sensitivity and uncertainty methods are quintessential for nuclear criticality safety and experiment design. This type of analysis relies on calculations of sensitivity coefficients; sensitivity coefficients of the effective neutron multiplication factor with respect to some nuclear data are predominantly calculated and used. As a part of the Laboratory Directed Research & Development project EUCLID (Experiments Underpinned by Computational Learning for Improvements in nuclear Data) at Los Alamos National Laboratory, sensitivity coefficients of many radiation detector measurement responses with respect to nuclear data were investigated. Specifically, this paper outlines a method to calculate point-kinetics parameters relative sensitivity coefficients with respect to nuclear data. Point-kinetics parameters such as the prompt neutron decay constant, effective delayed neutron fraction, and neutron generation time are especially important to experimenters and reactor operators designing systems with dynamic neutron populations. This method couples capabilities of the ACE (A Compact ENDF) nuclear data file toolkit, ACEtk, with the ability to load cross sections into the radiation transport code Monte Carlo N-Particle (MCNP). In conclusion, key aspects of optimizing this method for a particular application and sensitivity profiles of the Jezebel criticality experiment are examined and discussed.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Development of a military-specific mesh-type computational phantom library and its application to internal dosimetry and in-field radiological triage screening

Estimates of organ-absorbed and committed doses to individuals exposed to radioactive materials via acute inhalation often rely on internal dose coefficients and detector responses from reference human computational models. To achieve more accurate dose assessments to United States Armed Forces service members exposed in-field, computational models with varying morphometric parameters representative of this population are necessary. The International Commission on Radiological Protection (ICRP) Publication 145 provides detailed mesh reference computational phantoms (MRCPs) for adult males and females, with morphometric parameters matched to the 50th percentile. Previously, these phantoms were 2D and 3D scaled to match desired height, mass, and secondary anthropomorphic parameters in the creation of the University of Florida / Memorial Sloan Kettering (UF/MSK) computational phantom library. To achieve body fat percentage targets required for accession into the US Armed Forces, muscle and fat volumes were adjusted accordingly, thus, creating the UF/Department of Defence computational phantom library presented in this study. A comprehensive library of mesh-type computational human phantoms was created, including 57 adult males and 49 adult females with morphometric parameters aligned with United States Armed Forces service members. Phantoms were restricted to a body mass index between 19 and 27.5, with body fat percentages below 26% for males and 36% for females. Specific absorbed fractions were computed for selected source and target combinations, demonstrating how variations in height and body mass influence energy absorption in target regions relative to the ICRP MRCPs. Radiation detector responses were also computed, revealing that higher body masses resulted in decreased registered counts in the detection volume. These findings highlight the importance of incorporating morphometric variability in computational phantoms to achieve more accurate dose assessments and radiation detection responses for United States Armed Forces service members who inhale radioactive materials in-field.

computational phantoms↗

Three-colour digital holographic microscopy based on a Mach – Zender interferometer and a solid-state RGB laser

We have developed a facility for recording colour digital holograms involving a Mach – Zender interferometer and a pulsed solid-state RGB laser, which radiates simultaneously at three wavelengths: 451, 532, and 634 nm. These wavelengths are obtained in the conversion of the radiation of a pulsed Nd{sup 3+} : YAG laser (1064 nm), which operates in the regime of intracavity parametric oscillation at a wavelength of 1570 nm, with the subsequent conversion of its frequencies to the red, green, and blue spectral regions in nonlinear KTP-crystal elements. The combination of this three-wavelength pulsed light source with the Mach – Zender interferometer provides the simultaneous recording of three spectral digital holograms with one matrix RGB radiation detector. Pulsed three-colour digital holography shows promise for the analysis of fast processes and rapidly varying colour phase objects. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Skeletal and body composition evaluation

Research on radiation detectors for absorptiometry; analysis of errors affective single photon absorptiometry and development of instrumentation; analysis of errors affecting dual photon absorptiometry and development of instrumentation; comparison of skeletal measurements with other techniques; cooperation with NASA projects for skeletal evaluation in spaceflight (Experiment MO-78) and in laboratory studies with immobilized animals; studies of postmenopausal osteoporosis; organization of scientific meetings and workshops on absorptiometric measurement; and development of instrumentation for measurement of fluid shifts in the human body were performed. Instrumentation was developed that allows accurate and precise (2% error) measurements of mineral content in compact and trabecular bone and of the total skeleton. Instrumentation was also developed to measure fluid shifts in the extremities. Radiation exposure with those procedures is low (2-10 MREM). One hundred seventy three technical reports and one hundred and four published papers of studies from the University of Wisconsin Bone Mineral Lab are listed.

Mazess, R. B.↗

OSCAR-Mike: Why not ATAK?

The Office of Nuclear Smuggling Detection and Deterrence (NSDD) is evaluating methods to increase the probability that international partners will detect radioactive materials. One proposed method to accomplish this goal is to improve communications within teams operating in challenging environments. The goal of these improvements would be to enable remote monitoring of detection equipment, share data among end users in the field and subject matter experts, and integrate data from radiation detectors with other types of sensors and camera systems. Accomplishing this goal has the potential to improve the capabilities of currently deployed NSDD equipment. During FY 2021, Oak Ridge National Laboratory demonstrated some core and expanded capabilities of the Android Team Awareness Kit (ATAK), a situational awareness application developed by the US Department of Defense, to enable precision targeting, navigation, and data sharing. During FY 2022, Oak Ridge National Laboratory developed software requirements for an NSDD team awareness kit–based system. The requirements were developed by liaising with NSDD management and subject matter experts to determine NSDD’s needs and by reviewing available software and hardware solutions with US Department of Defense team awareness kit program managers and developers and radiation detection equipment vendors.

97 MATHEMATICS AND COMPUTING↗

Effect of Space Radiation on TES Detectors Performance

The Athena mission and its X-IFU instrument (X-ray Integral Field Unit) will be positioned at the Sun-Earth Lagrangian point L1, where it will be subject to solar wind (low flux plasma of 95% protons and 5% alpha particles) with energy below 0.1 MeV, and to galactic cosmic rays and solar flares (energetic protons, alpha particles, and electrons) with energies up to hundreds of MeV for protons and the GeV for heavier ions. Some of these particles will go through the satellite and hit the focal plane assembly and hence the detectors. These detectors will be TES (Transition-edge sensor) microcalorimeters, flown for the first time in such an environment. In order to ensure the performance of this type of detectors throughout the duration of such mission, it is critical to study the impact of the radiation on their behavior. Indeed, although a lot of reference material exist for semiconductor detectors such as CCDs, little is currently known about the impact of radiation on TES detectors. These energetic events could cause local heating or damage to the detectors and affect their performance. In this work, we describe how we designed a test campaign to assess the impact of L1 radiation on TES detectors for Athena/X-IFU-like missions and present the results of the tests. Analyses includes assessing changes in the pulse shapes and energy resolution of the detectors measured at 55 mK after several radiation dose steps performed at 4 K.

Sophie Beaumont↗

Uranium Holdup Monitoring with Compton Imaging as Function of Depth and Mass

Material Control and Accountability (MC&A) programs track masses of materials flowing through production processes, where some material remains in process equipment as holdup. Quantification of these masses using gamma emissions typically involves usage of a well characterized radiation detector and assumptions of geometric configuration to constrain detection efficiencies, where the Generalized Geometry Holdup (GGH) method is often used. Uncertainties on the order of ±50% are observed, where the difficulties arise based on the asymmetric and gradient distributions of material that do not fall within the bounds of GGH. Gamma imagers provide a possible means to improve this geometric knowledge. This work describes the process used in creating a series of mass standards to aid the development of imaging algorithms for quantification.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Contributions to the BeEST sterile neutrino search

Sterile neutrinos are hypothetical right-handed leptons that have been postulated as extensions to the Standard Model to help explain the origin of neutrino masses and the matter-antimatter asymmetry in the Universe. Sterile neutrinos with keV-scale masses are also a promising candidate for dark matter. LLNL and the Colorado School of Mines are developing an experiment to search for sterile neutrinos by measuring the \Beryllium-7 Electron capture in Superconducting Tunnel junctions (STJs)" (the \BeEST" Experiment). When 7 Be implanted into STJ radiation detectors decays by electron capture, the neutrino escapes and the energy of the recoiling 7 Li nucleus can be measured with high accuracy. Using conservation of energy and momentum, the mass of the emitted neutrino can then be found. Sterile keV neutrinos would generate additional peaks in the spectrum, and the experiment uses high-resolution STJs to observe such a potential signal. During my internship, I contributed to different aspects of the BeEST experiment. I designed a UHV setup for X-ray spectroscopy analysis with STJs. It will allow high-resolution X-ray spectroscopy of different materials to examine the broadening in the BeEST spectra, the origins of which are unknown but may be related to material effects inside the STJ detectors. The design accounts for the specific demands of the BeEST project, but provides a degree of flexibility that makes it useful for other potential STJ projects. Additionally, to test the accuracy of the electronics and data analysis routine, an arbitrary waveform generator (AWG) will be used to generate simulated spectra that contain sterile neutrino signals of a specified mass and admixture. For this I programmed an AWG to output random STJ signals whose amplitudes follow the appropriate user-de ned probability distribution. The AWG signals can be input into the 32-channel preamplifier to simulate any spectrum of interest and test the uniformity of the amplifier chain, as well as the sensitivity of the data analysis.

42 ENGINEERING↗

Sensor Placement Optimization Study for the Built Environment: Operational Use Cases

Systems of fixed-position radiation sensors can provide information that assists emergency responders following nuclear and radiological incidents. State, local, tribal, and territorial (SLTT) government agencies that implement systems of fixed-position sensors are faced with numerous decisions regarding sensor selection, quantity, and placement. To develop guidance on implementation of radiation detection systems, we simulated the release of radioactive material in an urban environment using a combination of three models: the Weather Research Forecasting (WRF), Quick Urban and Industrial Complex (QUIC), and Monte Carlo N-Particle (MCNP) models. We then evaluated the performance of several hypothetical sensor systems. The small number of simulations we conducted are not sufficient to generate definitive design guidance for radiation sensor systems, but we did identify trends that would be of interest to emergency planners. For a scenario that releases 1000 curies of Cs-137, radiation detectors were needed at 500-meter intervals to have a high likelihood of event detection and to estimate source location and plume detection. We also noted that optimal detector altitude varied with distance to the source. We recommend additional research in this area be conducted to support developing sensor placement guidelines that expand on a range of locations, isotopes, activity levels, and different weather conditions. Original simulation strategies included a range of environments, additional radioisotopes (Am241 and AmBe), and a larger selection of sensor types. These types of expansions would support SLTT guidance on sensor system recommendations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Matrix-Assisted Ionization of Molecular Uranium Species

Matrix-assisted ionization (MAI) demonstrates high sensitivity for a variety of organic compounds; however, few studies have reported the application of MAI for the detection and characterization of inorganic analytes. Trace-level uranium analysis is important in the realms of nuclear forensics, nuclear safeguards, and environmental monitoring. Traditional mass spectrometry methods employed in these fields require combinations of extensive laboratory chemistry sample preparation and destructive ionization methods. There has been recent interest in exploring ambient mass spectrometry methods that enable timely sample analysis and higher sensitivity than what is attainable by field-portable radiation detectors. Rapid characterization of uranium at nanogram levels is demonstrated in this study using MAI techniques. Mass spectra were collected on an atmospheric pressure mass spectrometer for solutions of uranyl nitrate, uranyl chloride, uranyl acetate, and uranyl oxalate utilizing 3-nibrobenzonitrile as the ionization matrix. The uranyl complexes investigated were detectable, and the chemical speciation was preserved. Sample analysis was accomplished in a matter of seconds, and limits of detection of 5 ng of uranyl nitrate, 10 ng of uranyl oxalate, 100 ng of uranyl chloride, and 200 ng of uranyl acetate were achieved. The observed gas-phase speciation was similar to negative-ion electrospray ionization of uranyl compounds with notable differences. Six matrix-derived ions were detected in all negative-ion mass spectra, and some of these ions formed adducts with the uranyl analyte. Subsequent analysis of the matrix suggests that these molecules are not matrix contaminants and are instead created during the ionization process.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

$β$-delayed-neutron studies of 135,136 Sb and 140 I performed with trapped ions

In this work, Beta-delayed-neutron $(βn)$ spectroscopy was performed using the Beta-decay Paul Trap and an array of radiation detectors. The $βn$ branching ratios and energy spectra for 135,136 Sb and 140 I were obtained by measuring the time of flight of recoil ions emerging from the trapped ion cloud. These nuclei are located at the edge of an isotopic region identified as having $βn$ branching ratios that impact the $r$-process abundance pattern around the A ≈ 130 peak. For 135,136 Sb and 140 I, $βn$ branching ratios of 14.6(13)%, 17.6(29)%, and 7.6(28)% were determined, respectively. The $βn$ energy spectra obtained for 135 Sb and 140 I are compared with results from direct neutron measurements, and the $βn$ energy spectrum for 136 Sb has been measured for the first time.

42 ENGINEERING↗

Study on Application of Distributed Network of Sensors with List Mode for NMAC Literature Review

Nuclear material accounting and control (NMAC) for nuclear security detects, deters, and resolves questions related to unauthorized removal (i.e. theft) or misuse of nuclear material. NMAC also serves as a key insider threat mitigation measure and aids in recovery of nuclear material that is missing. Effective nuclear security depends on NMAC for timely and accurate information about nuclear material types, quantities, and locations. Bulk nuclear material processing facilities, however, present unique challenges for effective NMAC due to the presence of large quantities of material in-process and the accumulation of residual material holdup within process equipment. These holdup accumulations can obscure accurate physical inventory taking and complicate efforts to resolve NMAC irregularities at the facility level. Bulk material monitoring systems often rely on material balance calculations and indirect measurement techniques, which may mask protracted theft of smaller amounts of nuclear material. These monitoring limitations have generated increased interest in continuous monitoring technologies, including distributed non-destructive assay (NDA) sensor networks capable of providing real-time or near-real-time measurement of material movement and accumulation within bulk processing environments. Recent advancements in distributed networks of NDA radiation detectors and sensing technologies provide an opportunity to address these limitations. Although such distributed sensor networks have been implemented in select facilities for IAEA Safeguards applications, their potential for supporting NMAC functions specifically tailored to nuclear security objectives remains largely unexplored. Furthermore, emerging list-mode data acquisition technologies have reached high technology readiness levels, enabling time-correlated detection of nuclear events across multiple temporal scales. These capabilities provide enhanced opportunities for accurate holdup measurement, continuous process monitoring, and improved detection of material theft or misuse over time. The increasing global expansion of civil nuclear power and development of related bulk material processing facilities, including those supporting high-assay low-enriched uranium (HALEU) and other advanced reactor fuel fabrication, further increases the need for advanced measurement and monitoring strategies for NMAC.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enhanced sensitivity to trace 238 U impurity of sapphire via coincidence neutron activation analysis

Sapphire has mechanical and electrical properties that are advantageous for the construction of internal components of radiation detectors such as time projection chambers and bolometers. However, it has proved difficult to assess its 232 Th and 238 U content down to the picogram per gram level. Here, this work reports an experimental verification of a computational study that demonstrates 𝛾⁢𝛾 coincidence counting, coupled with neutron activation analysis (NAA), can reach ppt sensitivities. Combining results from 𝛾⁢𝛾 coincidence counting with those of earlier single-𝛾 counting based NAA shows that a sample of Saint Gobain sapphire has 232 Th and 238 U concentrations of <0.26 ppt and <2.3 ppt, respectively; the best constraints on the radiopurity of sapphire.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enhanced Neutron and γ-Ray Detection via 6 Li Substitution in Undoped and Tl-Doped Zero-Dimensional Perovskite Cs 3 Cu 2 I 5 Scintillators

Radiation detectors are crucial in a wide variety of research and commercial applications, such as oil and gas exploration, medical imaging, nuclear nonproliferation, and homeland security. Neutron and gamma-ray detectors are fundamental components in portal monitors at ports and border crossings, bolstering national security against radiological threats. This study presents a dual-mode scintillator, undoped and Tl-doped 6 Li-Cs 3 Cu 2 I 5 , and demonstrates its potential as a promising material for simultaneous thermal neutron and gamma-ray detection. We explore the Bridgman growth of both undoped and thallium doped Li → Cu and Li → Cs substitutional systems with various Li doping levels and assess their impact on scintillation properties. Under 662 keV gamma-ray excitation, the undoped crystals had light yields up to 35,900 ph/MeV, with energy resolutions down to 4.5%. The Tl-doped crystals performed better than the undoped crystals with light yields peaking at 65,900 ph/MeV and energy resolutions as low as 3.5%. When exposed to a moderated 252 Cf excitation source, our crystals had light yields between 102,900 and 167,200 photons per thermal neutron capture, with a full energy thermal neutron peak reaching 3 MeV in gamma equivalent energy. Pulse shape discrimination studies reveal well-separated gamma and neutron events, resulting in Figure-Of-Merit (FOM) as high as 3.7. Furthermore, these findings highlight the potential of Li-doped Cs 3 Cu 2 I 5 as a viable candidate for next-generation dual-mode scintillators.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Infrared response measurements on radiation-damaged Si/Li/ detectors.

The improved infrared response (IRR) technique has been used to qualitatively compare radiation effects on Si(Li) detectors with energy levels reported for silicon in the literature. Measurements have been made on five commercial silicon detectors and one fabricated in-house, both before and after irradiation with fast neutrons, 1.9-MeV protons, and 1.6-MeV electrons. Effects dependent upon the extent of radiation damage have been observed. It seems likely that the photo-EMF, or photo-voltage, effect is the basic mechanism for the observation of IRR in p-i-n diodes with a wide i-region. Experimental characteristics of the IRR measurement are in agreement with those of the photovoltage effect.

Sher, A. H.↗

Investigation of the Solution Chemistry of Hybrid Organic–Inorganic Indium Halides for New Material Discovery

Recently, metal halide perovskites (MHPs) have emerged as a new class of materials for optical and electronic applications such as solar cells and ionizing radiation detectors. Although the solution-processability of MHPs is among their greatest advantages, the solution chemistries of most metal halide systems and their relationship with the observed structural and chemical diversity are poorly understood. In this work, we study the solution chemistry of a model indium halide system, methylammonium (MA)–In–Br, using a combination of the UV–vis spectroscopy, electrospray ionization mass spectrometry (ESI-MS) measurements, small-angle X-ray scattering (SAXS), and density functional theory (DFT) calculations. Our results show that indium could form either octahedral [InBr 6 3– ] or tetrahedral [InBr 4 – ] anions in solution or a combination of both, depending on the loading ratios of MABr and InBr 3 reactants. Understanding the solution chemistry of this system and recognizing the optical fingerprints of these polyanions allow for targeted crystallization of two novel compounds: MAInBr 4 featuring tetrahedral [InBr 4 – ] anions and MA 2 InBr 5 containing both octahedral [InBr 6 3– ] and tetrahedral [InBr 4 – ] anions. Further increase of the MABr content leads to the formation of previously reported MA 4 InBr 7 , containing only octahedral [InBr 6 3– ] anions separated by Br – anions. Furthermore, our results suggest that understanding the solution chemistry of multinary metal halide systems could be a valuable tool for discovering functional materials for practical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗