Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ROOFS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Rooftop Photovoltaic Technical Potential in the United States

This data submission contains a workbook with data, and three sets of shapefiles that correspond to that data. The workbook contains data that underlies the 2016 technical report Rooftop Solar Photovoltaic Technical Potential in the United States: A Detailed Assessment. This data is separated into small, medium, and large buildings. A small building is less than 5,000 square feet, a medium building is between 5,000 and 25,000 square feet, and a large building is greater than 25,000 square feet. The suitability of roof area for hosting PV was determined based on shading (energy production not less than 70% of an identical unshaded system in the same location), tilt (no greater than 60 degree tilt), azimuth (not facing north), and contiguous roof area (at least 10 square meters available) criteria. For further documentation of methods and assumptions, see the 2016 report. The tab Rooftop_PV_with_Lidar_Coverage contains estimates for zip codes where at least some lidar data was available. The zip_percentage column indicates the percentage of area of each zip code was covered by lidar data -- only buildings within the covered area are reported here, meaning that the values for incompletely covered zip codes are under-reported. The tab Small_Building_Suitability contains estimates of the number of small buildings and the percentage of those buildings that have at least some area that is suitable for rooftop PV, for all zip codes in the contiguous US. Where lidar data was not available, a model was used to estimate the data. Estimates for medium and large buildings were not produced at the zip code level, because of insufficient input data.

14 SOLAR ENERGY↗

Applications of thermal infrared imagery for energy conservation and environmental surveys

The survey procedures, developed during the winter and summer of 1976, employ color and color infrared aerial photography, thermal infrared imagery, and a handheld infrared imaging device. The resulting imagery was used to detect building heat losses, deteriorated insulation in built-up type building roofs, and defective underground steam lines. The handheld thermal infrared device, used in conjunction with the aerial thermal infrared imagery, provided a method for detecting and locating those roof areas that were underlain with wet insulation. In addition, the handheld infrared device was employed to conduct a survey of a U.S. Army installation's electrical distribution system under full operating loads. This survey proved to be cost effective procedure for detecting faulty electrical insulators and connections that if allowed to persist could have resulted in both safety hazards and loss in production.

Carney, J. R.↗

Thermal structure and kinematics of mid-oceanic ridge axis - Some implications to basaltic volcanism

Based on studies of ophiolitic complexes, a characterization of basaltic magmas at midocean ridges is proposed. A thin molten region about 3 km wide probably exists at the top of the magma chamber; primitive material enters the uppermost part of the chamber from below, and fractionated material is removed by the upward extrusion of dikes and settling of crystals to form a mush which probably fills the bulk of the chamber. The roof of the magma chamber is probably cooler than the melting temperature of primitive basalt. Secondary melts and the volume of the uppermost molten region are considered. Weaknesses along the line of dike intrusion and limited plating of material onto the roof of the chamber may restrict dike intrusion to the exceeding narrow zone inferred from ophiolitic complexes.

Sleep, N. H.↗

Development and Testing of Shingle-type Solar Cell Modules

The design, development, fabrication and testing of a shingle-type terrestrial solar cell module which produces 98 watts/sq m of exposed module area at 1 kW/sq m insolation and 61 C are reported. These modules make it possible to easily incorporate photovoltaic power generation into the sloping roofs of residential or commercial buildings by simply nailing the modules to the plywood roof sheathing. This design consists of nineteen series-connected 53 mm diameter solar cells arranged in a closely packed hexagon configuration. These cells are individually bonded to the embossed surface of a 3 mm thick thermally tempered hexagon-shaped piece of glass. Polyvinyl butyral is used as the laminating adhesive.

Shepard, N. F., Jr.↗

An approach to automated longwall mining

The longwall system of mining coal, providing advantages in the areas of productivity as well as health and safety, is described, and technological developments leading to a full automation of the system are discussed. In the longwall system large blocks of coal (up to 600 feet wide and up to 5000 feet long) are developed, with each block mined out by taking successive slices across the short dimension of the block and loading the broken coal onto a conveyor. A self-advancing system supports the roof over the length of the face throughout cutting and loading, with the supports advanced with the face, and the roof allowed to collapse behind them. A double-ranging drum longwall shearer provides the system with an efficient yaw, roll, and variable-thickness vertical control. Currently two machine operators function as error detectors and controllers. It is shown that electronic sensors can lead to a fully automated vertical control system, and automatic roll control is achievable with available instruments and machine tilt actuators.

Palowitch, E. R.↗

Development of a shingle-type solar cell module

The development of a solar cell module, which is suitable for use in place of shingles on the sloping roofs of residental or commercial buildings, is reported. The design consists of nineteen series-connected 53 mm diameter solar cells arranged in a closely packed hexagon configuration. The shingle solar cell module consists of two basic functional parts: an exposed rigid portion which contains the solar cell assembly, and a semi-flexible portion which is overlapped by the higher courses of the roof installation. Consideration is given to the semi-flexible substrate configuration and solar cell and module-to-module interconnectors. The results of an electrical performance analysis are given and it is noted that high specific power output can be attributed to the efficient packing of the circular cells within the hexagon shape. The shingle should function for at least 15 years, with a specific power output of 98 W/sq w.

Shepard, N. F., Jr.↗

Solar potential inventory and modeling

Image processing procedures for calculating the energy that roof-mounted solar collectors can potentially supply in a metropolitan area are presented. Satellite multispectral imagery from which land cover types can be determined digitally was sampled in order to estimate the percentage of land area occupied by flat or south-facing roof tops in residential and commercial/industrial areas. Procedures were applied to the various power subdistricts of the western San Fernando valley of California, and it was found that on the average 120% of the existing power demand could be met if only half the useable rooftop area were utilized, amounting to 385 MW of peak power and indicating the applicability of solar cells to power generation in urban areas.

Angelici, G. L.↗

Closed-circulation system for motel hot water--Savannah, Georgia

Inexpensive guy wires support roof-mounted solar-energy collectors. Mounting system withstands 120 mph winds with no roof penetrations. Collectors circulate 50 percent ethylene glycol solution eliminating need for drain system for freeze protection. Heat exchanger transfers energy to domestic hot water which heats to 140 F.

Source record↗

Design, fabrication, test, and qualification and price analysis of third generation design solar cell modules

The Block 4 shingle type module makes it possible to apply a photovoltaic array to the sloping roof of a residential building by simply nailing the overlapping hexagon shaped shingles to the plywood roof sheathing. This third-generation shingle module design consists of nineteen series connected 100 mm diameter solar cells which are arranged in a closely packed hexagon configuration to provide in excess of 75 watts/sq m of exposed module area under standard operating conditions. The solar cells are individually bonded to the embossed underside of a 4.4 mm thick thermally tempered piece of glass. An experimental silicone pottant was used as the transparent bonding adhesive between the cells and glass. The semi-flexible portion of each shingle module is a composite laminate construction consisting of an outer layer of FLEXSEAL bonded to an inner core of closed cell polyethylene foam. Silaprene is used as the substrate laminating adhesive. The module design has satisfactorily survived qualification testing program which includes 50 thermal cycles between -40 and +90 C, a seven day temperature-humidity exposure test, and a wind resistance test.

Shepard, N. F.↗

Integrated residential photovoltaic array development

Sixteen conceptual designs of residential photovoltaic arrays are described. Each design concept was evaluated by an industry advisory panel using a comprehensive set of technical, economic and institutional criteria. Key electrical and mechanical concerns that effect further array subsystem development are also discussed. Three integrated array design concepts were selected by the advisory panel for further optimization and development. From these concepts a single one will be selected for detailed analysis and prototype fabrication. The three concepts selected are: (1) An array of frameless panels/modules sealed in a T shaped zipper locking neoprene gasket grid pressure fitted into an extruded aluminum channel grid fastened across the rafters. (2) An array of frameless modules pressure fitted in a series of zipper locking EPDM rubber extrusions adhesively bonded to the roof. Series string voltage is developed using a set of integral tongue connectors and positioning blocks. (3) An array of frameless modules sealed by a silicone adhesive in a prefabricated grid of rigid tape and sheet metal attached to the roof.

Royal, G. C., III↗

Design, fabrication and test of last cut Follower

An optical device for following the cut in mining operations is described, and the results of acceptance testing reported. A measuring accuracy of + or - 1/16 inch was demonstrated. Preliminary results on longwall testing with the device mounted on a shearer are presented. Roof profiles measured during tramming and during cutting are presented. Comparison of acoustic measurements with optical measurement of the roof profiles indicates close agreement.

Ashley, P. R.↗

In-mine testing of a natural background sensor, part B

The capability of a natural background sensor for measuring the thickness of top coal on a longwall face was examined. The limitations on the time during which tests could be performed, and the roof conditions, did not produce readings of top coal measurements during the shearer operation. It was demonstrated that the system is capable to survive operating conditions in the mine environment, while the static tests confirmed that the natural background sensor approach is a valid method of measuring top coal thickness in mines where the roof rock provides a constant radiation level. It is concluded that the practical results will improve sequent development of an integrated vertical control system which is information from the natural background system.

Martzloff, F. D.↗

Side Shield for Wall Support

Method employs curved shield on each side of mining machine. In stowed position, shield folded against roof-support columns on one side. In deployed position, shield raised and braced against coal-seam wall by hydraulic cylinder. Shield supports wall until roof and wall properly secured by bolting and cement coating.

Lewis, E. V.↗

Residential Photovoltaic/Thermal Energy System

Proposed system supplies house with both heat and electricity. Pair of reports describes concept for self-sufficient heating, cooling, and power-generating system for house. Panels on walls of house provide hot water, space heating, and heat to charge heat-storage system, and generate electricity for circulation pumps and fans. Roof panels generate electricity for household, operate heat pump for summer cooling, and provide supplementary winter heating via heat pump, using solar-cell cooling-fluid loop. Wall and roof panels used independently.

Selcuk, M. K.↗

The structure of the Martian cryolithosphere upper levels

Structural inhomogeneities of the Martian cryolithosphere upper levels were studied by the proposed crater method. On the basis of analysis of 127 photomaps of 1:2 million scale morphological and morphometrical parameters of all the fresh craters larger than 1 km in diameter with fluidized ejecta and without it were investigated. Using the parameters of the craters, the roof depths of ice-bearing rocks were estimated and the data on the ice relative constant in the excavated permafrost layer were obtained. These data were used for the construction of maps of the boundary depth between ice-free nearsurface layer and ice-bearing rocks. A series of maps of the relative ice content for individual permafrost horizons was constructed. It was deduced from the obtained maps that the zone of the dryest nearsurface rocks on Mars is in the latitude belt + or - 30 degrees where maximum floor depths of the ice-bearing rocks vary from 400 to more than 400 m. It was found that the thickness of ice-free rocks in the Southern Hemisphere is larger than in the Northern one. The tendency of similarity of latitudinal zonality observed both on the maps of the minimal and mean roof depths may be considered as an indicator of structural stability of upper horizons of the Martian cryolithosphere down to the depths of 300 to 400 m. The areas of minimal ice content in the nearsurface layers coincide with the zone of maximum thickness of ice-free rocks. The ice relative content in Martian rocks becomes systematically higher from 30 deg latitude to the polars. The same tendency is observed in depth. The data obtained may be useful for the selecting of landing sites for Mars samples return and other missions.

Kuzmin, R. O.↗

Fate of a perched crystal layer in a magma ocean

The pressure gradients and liquid compressibilities of deep magma oceans should sustain the internal flotation of native crystals owing to a density crossover between crystal and liquid. Olivine at upper mantle depths near 250 km is considered. The behavior of a perched crystal layer is part of the general question concerning the fate of any transient crystal carried away from a cooling surface, whether this be a planetary surface or the roof of an intrusive magma body. For magma bodies thicker than a few hundred meters at modest crustal depths, the major cooling surface is the roof even when most solidification occurs at the floor. Importation of cool surroundings must also be invoked for the generation of a perched crystal layer in a magma ocean, but in this case the perched layer is deeply embedded in the hot part of the magma body, and far away from any cooling surface. Other aspects of this study are presented.

Morse, S. A.↗

Causes of failure of airship shed

The causes of the collapse of airship shed, which was being taken down at Niediergorsdorf, are discussed. This shed, which was built of iron, was 184 m long, 28 m high, and 35 m wide. The demolition of the shed had been assigned to unskilled men who proceeded to remove certain key structural supports, leaving the structure in such a condition that relatively small eccentricities of the columns or spans or of lateral forces could easily have caused the columns or spans to break down. A small gust of wind would have perhaps sufficed to bring the building down. An analysis is also given of the suction effects on the roof of an air shed in Staaken. The damage to this shed, which occurred during a storm, was due to the fact that the shed had no opening in its top for equalizing the air pressure within and without. The location of the plates blown off the roof correspond to the point of greatest suction.

Sonntag, R↗