Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ROI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Testing Saliency Parameters for Automatic Target Recognition

A bottom-up visual attention model (the saliency model) is tested to enhance the performance of Automated Target Recognition (ATR). JPL has developed an ATR system that identifies regions of interest (ROI) using a trained OT-MACH filter, and then classifies potential targets as true- or false-positives using machine-learning techniques. In this project, saliency is used as a pre-processing step to reduce the space for performing OT-MACH filtering. Saliency parameters, such as output level and orientation weight, are tuned to detect known target features. Preliminary results are promising and future work entails a rigrous and parameter-based search to gain maximum insight about this method.

regions of interest (ROI)↗

Lessons Learned from the Private Sector

This session is focused on lessons learned from private sector energy projects that could be applied to the federal sector. This presentation tees up the subsequent presentations by outlining the differences between private and federal sectors in objectives, metrics for determining success, funding resources/mechanisms, payback and ROI evaluation, risk tolerance/aversion, new technology adoption perspectives, and contracting mechanisms.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Concept of an upright wearable positron emission tomography imager in humans

Abstract Background Positron Emission Tomography ( PET ) is traditionally used to image patients in restrictive positions, with few devices allowing for upright, brain‐dedicated imaging. Our team has explored the concept of wearable PET imagers which could provide functional brain imaging of freely moving subjects. To test feasibility and determine future considerations for development, we built a rudimentary proof‐of‐concept prototype (Helmet_ PET ) and conducted tests in phantoms and four human volunteers. Methods Twelve Silicon Photomultiplier‐based detectors were assembled in a ring with exterior weight support and an interior mechanism that could be adjustably fitted to the head. We conducted brain phantom tests as well as scanned four patients scheduled for diagnostic F 18‐ FDG PET / CT imaging. For human subjects the imager was angled such that field of view included basal ganglia and visual cortex to test for typical resting‐state pattern. Imaging in two subjects was performed ~4 hr after PET / CT imaging to simulate lower injected F 18‐ FDG dose by taking advantage of the natural radioactive decay of the tracer (F 18 half‐life of 110 min), with an estimated imaging dosage of 25% of the standard. Results We found that imaging with a simple lightweight ring of detectors was feasible using a fraction of the standard radioligand dose. Activity levels in the human participants were quantitatively similar to standard PET in a set of anatomical ROI s. Typical resting‐state brain pattern activation was demonstrated even in a 1 min scan of active head rotation. Conclusion To our knowledge, this is the first demonstration of imaging a human subject with a novel wearable PET imager that moves with robust head movements. We discuss potential research and clinical applications that will drive the design of a fully functional device. Designs will need to consider trade‐offs between a low weight device with high mobility and a heavier device with greater sensitivity and larger field of view.

60 APPLIED LIFE SCIENCES↗

Comparison of [ 11 C]TZ1964B and [ 18 F]MNI659 for PET imaging brain PDE10A in nonhuman primates

Abstract Phosphodiesterase 10A ( PDE 10A) inhibitors show therapeutic effects for diseases with striatal pathology. PET radiotracers have been developed to quantify in vivo PDE 10A levels and target engagement for therapeutic interventions. The aim of this study was to compare two potent and selective PDE 10A radiotracers, [ 11 C] TZ 1964B and [ 18 F] MNI 659 in the nonhuman primate ( NHP ) brain. Double scans in the same cynomolgus monkey on the same day were performed after injection of [ 11 C] TZ 1964B and [ 18 F] MNI 659. Specific uptake was determined in two ways: nondisplaceable binding potential ( BP ND ) was calculated using cerebellum as the reference region and the PDE ‐10A enriched striatum as the target region of interest ( ROI ); the area under the time–activity curve ( AUC ) for the striatum to cerebellum ratio was also calculated. High‐performance liquid chromatography ( HPLC ) analysis of solvent‐extracted NHP plasma identified the percentage of intact tracer versus radiolabeled metabolites samples post injection of each radiotracer. Both radiotracers showed high specific accumulation in NHP striatum. [ 11 C] TZ 1964B has higher striatal retention and lower specific striatal uptake than [ 18 F] MNI 659. The BP ND estimates of [ 11 C] TZ 1964B were 3.72 by Logan Reference model (Logan REF ) and 4.39 by simplified reference tissue model ( SRTM ); the BP ND estimates for [ 18 F] MNI 659 were 5.08 (Logan REF ) and 5.33 ( SRTM ). AUC ratios were 5.87 for [ 11 C] TZ 1964B and 7.60 for [ 18 F] MNI 659. Based on BP ND values in NHP striatum, coefficients of variation were ~10% for [ 11 C] TZ 1964B and ~30% for [ 18 F] MNI 659. Moreover, the metabolism study showed the percentage of parent compounds were ~70% for [ 11 C] TZ 1964B and ~50% for [ 18 F] MNI 659 60 min post injection. These data indicate that either [ 11 C] TZ 1964B or [ 18 F] MNI 659 could serve as suitable PDE 10A PET radiotracers with distinguishing features for particular clinical application.

59 BASIC BIOLOGICAL SCIENCES↗

Texture analysis of small renal cell carcinomas at MDCT for predicting relevant histologic and protein biomarkers

Purpose: To assess CT texture features of small renal cell carcinomas (≤ 4cm) for association with key pathologic features including protein biomarkers. Methods: Quantitative CT texture analysis (CTTA) of small renal cancers (≤ 4cm) was performed on non-contrast and portal venous phase abdominal MDCT scans with an ROI drawn at the largest cross-sectional diameter of the tumor using commercially available software. Texture parameters including mean pixel attenuation, the standard deviation (SD) of the pixel distribution histogram, entropy, the mean of positive pixels, the skewness (i.e., asymmetry) of the pixel histogram, kurtosis (i.e., peakness) of the pixel histogram, and the percentage of positive pixels were correlated with pathologic data from surgical resection, including histology and nuclear grade, as well as microarray analysis in a subset (n = 40) including Ki67 index, CRP, and neovascularization (CD105/CD31). Results: Portal venous phase images were available in 249 patients (105 women, 144 men; mean age, 56.7 years) with tumors ≤ 4cm (mean, median, range, ± SD; 2.66, 2.60, 0.3–4.0 ± 0.85 cm). CT texture features of standard deviation, mean of the positive pixels, and entropy of the pixel histogram were significantly associated with histologic cell type (clear vs. non-clear; p < 0.001). Entropy and mean of the positive pixels also showed an association with nuclear grade, although not statistically significant. In the microarray analysis subset, kurtosis of the pixel histogram was associated with CD105/CD31 (p = 0.05). SD also showed some association with CD 105 positivity (p = 0.02) and CAIX expression (p = 0.01). Non-contrast CT images were available in 174 patients (72 women, 102 men; mean age, 57.5 years). Although the association with histology was not as strong as on the portal venous phase, in the subset of patients with microarray data, SD was found to correlate with CRP (p = 0.08), kurtosis with CRP (p = 0.004), CD105/CD31 (p = 0.002), and with Ki 67 index (p < 0.001). Conclusion: CT texture features were significantly associated with important histopathologic features in small renal cancers. These non-invasive measures can be performed retrospectively and may provide useful information when determining follow-up and treatment of small renal cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Virtual monoenergetic reconstruction of contrast-enhanced CT scans of the abdomen and pelvis at 40 keV improves the detection of peritoneal metastatic deposits

Purpose: To evaluate the role of virtual monoenergetic imaging (VMI) in the detection of peritoneal metastatic disease in contrast-enhanced computed tomography (CT) of the abdomen and pelvis and to compare this technique to the conventional 120 kV mixed dataset. Materials and methods: Institutional review board approval was obtained with no informed consent required for this retrospective analysis. 43 consecutive patients with histopathologically confirmed peritoneal disease were scanned using a standard protocol on a 128-section dual-source, dual-energy CT system (100/140 keV). Scans were retrospectively reconstructed at VMI energy levels from 40–110 keV in 10 keV increments and were analyzed both quantitatively and qualitatively. CNR values for peritoneal metastatic deposits were recorded using region of interest (ROI) analysis at each energy level for all VMI datasets. Subjective analysis was performed by two independent fellowship-trained readers with combined experience of greater than 15 years. Qualitative parameters included diagnostic acceptability, subjective noise, and contrast resolution and confidence. Results: The contrast-to-noise ratios (CNRs) for peritoneal metastatic deposits at the different VMI energy levels were compared using a one-way ANOVA with Tukey Post Test, and the optimal CNR was observed at 40 keV (p < 0.0001). Qualitative parameters were compared using a Paired T Test. Subjective noise, diagnostic acceptability, and contrast resolution was significantly better on the conventional images, but readers reported increased confidence on VMI at 40 keV (p < 0.001). Conclusion: VMI reconstruction of contrast-enhanced dual-energy CT scans of the abdomen and pelvis at 40 keV maximizes the conspicuity of metastatic peritoneal deposits and improves radiologists’ diagnostic confidence compared with conventional CT images. We recommend using virtual monoenergetic datasets at 40 keV as a tool for improving the detection of these lesions in routine clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Liver metastases of neuroendocrine tumors: is it possible to diagnose different histologic subtypes depending on multiphasic CT features?

Purpose: To assess and compare the multiphasic computed tomography (CT) features of neuroendocrine tumor (NET) liver metastases and to investigate the possibility to predict the histologic subtype of the primary tumor. Materials and methods: Between January 2013 and December 2017 patients with biopsy proven NET with at least one liver metastasis who underwent multiphasic CT were enrolled in this study. All cases were acquired using a standardized multiphasic liver CT protocol, arterial, portal, and hepatic venous phases were obtained. Images were retrospectively analyzed in consensus by two abdominal radiologists blinded to clinical data and histologic subtype. The size, number, and location of lesions were noted. Enhancement patterns of each lesion on arterial, portal, and hepatic venous phases were assessed. For quantitative analysis, CT attenuation of tumors, liver parenchyma, and aorta were measured using a circular region of interest (ROI) on arterial, portal, and hepatic venous phases for reflecting the blood supply of the tumor. Tumor-to-aorta and tumor-to-liver ratio were calculated in all three phases. Differences between subtypes of NET liver metastases were studied using ROC analysis of clustered data. Results: A total of 255 neuroendocrine tumor liver metastases divided into 101 (39.6%) pancreatic, 60 (23.5%) gastroenteric and 94 (36.8%) lung NET liver metastases were analyzed. Contrast enhancement of lesions was homogeneous in 78% of patients (n = 199), which was significantly more frequent in patients with pancreatic group than in those with gastroenteric origin (n = 90, 89.1% vs. n = 28, 46.7%; p < 0.001). Gastroenteric NET metastases frequently showed heterogeneous enhancement, which was significantly higher than in the other two groups (50% vs. 3% and 2%). With respect to the location of the primary tumor, the difference in enhancement patterns of the liver lesions was statistically significant (p < 0.001). Pancreatic NET metastases were mostly hyperdense on arterial images and isodense on portal and hepatic venous phase images (79.2%, n = 80). Gastroenteric NET metastases were mostly hyperdense on arterial phase images and hypodense on portal and hepatic venous phase images (n = 28, 46.7%). The most frequent pattern for lung NET metastases was hypoattenuation on all three phase images (n = 44, 46.8%). ROC analysis of clustered data revealed statistically significant differences between pancreatic NET liver metastases, gastroenteric NET liver metastases, and lung NET liver metastases in terms of tumor-to-aorta (T–A) ratio and tumor-to-liver (T–L) ratio (p < 0.001). Conclusion: We observed statistically significant differences in multiphasic CT features (enhancement pattern, T–A ratio, and T–L ratio) between histologic subtypes of NET liver metastases. As the difference in histological subtypes of NET liver metastases results in a different prognosis and different management strategy, these CT features might help to identify the primary tumor when it is not known to ensure accurate tumor staging and to provide optimal treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

5-Fluorouracil induced liver toxicity in patients with colorectal cancer: role of computed tomography texture analysis as a potential biomarker

Purpose: To assess if CT texture analysis (TA) can serve as a biomarker of liver toxicity in patients with colorectal cancer treated with 5-fluorouracil (5-FU)-based chemotherapy. Methods: In this IRB-approved, HIPAA-compliant retrospective study, patients with colorectal cancer treated with 5-FU-based regimens during 2008–2010 were identified from institutional electronic database. Total 43 patients (23 women; mean age 56 years) with normal baseline liver function tests (LFTs), availability of baseline (pre-chemotherapy) and first follow-up CT (median 1.7 months, interquartile range (IQR) 1.5–2.5) performed during chemotherapy were included. Two single-slice ROI of right and left liver lobe were obtained on baseline and first follow-up CT for TA. Texture features [mean, entropy, kurtosis, skewness, mean of positive pixel, standard deviation (SD)] were extracted using a commercially available software (TexRAD; Feedback Medical Ltd, Cambridge, UK). Changes in texture parameters between baseline and follow-up CT were evaluated with Wilcoxon signed-rank test for patients with and without LFT elevation during chemotherapy. Results: Patients with LFT elevation (n = 34; 79%) showed significantly different mean, entropy, skewness, and SD (p values range 0.007–0.047) between baseline and first follow-up CT. No significant changes in features were observed in patients without LFT elevation (n = 9; 21%). In 19 patients (56%), first follow-up CT was performed before elevation of LFTs was observed. Conclusions: This proof-of-concept study shows that there are early changes in liver texture on first follow-up CT in patients with LFT elevation during 5-FU-based chemotherapy for colorectal cancer. In more than 50% of cases, these changes occur before LFT elevation becomes evident on blood tests.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection of Lung Contour with Closed Principal Curve and Machine Learning

Radiation therapy plays an essential role in the treatment of cancer. In radiation therapy, the ideal radiation doses are delivered to the observed tumor while not affecting neighboring normal tissues. In three-dimensional computed tomography (3D-CT) scans, the contours of tumors and organs-at-risk (OARs) are often manually delineated by radiologists. The task is complicated and time-consuming, and the manually delineated results will be variable from different radiologists. We propose a semi-supervised contour detection algorithm, which firstly uses a few points of region of interest (ROI) as an approximate initialization. Then the data sequences are achieved by the closed polygonal line (CPL) algorithm, where the data sequences consist of the ordered projection indexes and the corresponding initial points. Finally, the smooth lung contour can be obtained, when the data sequences are trained by the backpropagation neural network model (BNNM). We use the private clinical dataset and the public Lung Image Database Consortium and Image Database Resource Initiative (LIDC-IDRI) dataset to measure the accuracy of the presented method, respectively. To the private dataset, experimental results on the initial points which are as low as 15% of the manually delineated points show that the Dice coefficient reaches up to 0.95 and the global error is as low as 1.47 × 10{sup −2}. The performance of the proposed algorithm is also better than the cubic spline interpolation (CSI) algorithm. While on the public LIDC-IDRI dataset, our method achieves superior segmentation performance with average Dice of 0.83.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis and imaging of boron distribution in maize by quantitative neutron capture radiography

Quantitative neutron capture radiography (QNCR) of 10 B found in pre-dried maize samples has been conducted. Calibration standards constructed from filter paper mimicked plant tissues to reduce confounding matrix effects. A mathematical track elimination method improves the LOD as well as the visual contrast image at low boron concentration levels. The LOD for total boron is 1.7 µg/g in a 4 mm 2 region of interest (ROI). The w(B) in five individual maize tassel meristems has been determined to be 14.9 µg/g – 21.2 µg/g.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

The economic impacts of carbon emission trading scheme on building retrofits: A case study with U.S. medium office buildings

As a popular emission reduction tool, the carbon emission trading scheme (ETS) can potentially add an economic incentive for building owners to retrofit buildings in addition to the cost savings in energy. However, the additional economic benefits of building retrofits brought by ETS has not been quantitively investigated yet. Here, in order to fill this gap, this study proposed a systematic economic evaluation method to investigate the economic impacts of ETS on building retrofits. The reduction of the payback period and the increase of the return on investment are adopted as evaluation metrics. Using medium office buildings as an example, this study predicted the economic impacts of ETS on building retrofits at four locations in the U.S., and three different carbon prices were investigated. The results show that carbon prices have significant economic impacts on building retrofits. With the relatively low forecasted time-variant carbon prices (around 10 USD per ton), the economic impacts of ETS on building retrofits are small. When carbon prices increase, the impacts of ETS would be up to 25% for 50 USD per ton (current prices in European Union) and 51% for 100 USD per ton. Furthermore, locations with more fossil energy have higher relative changes in the payback period and ROI but are more sensitive to carbon prices.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Considerations and code for partial volume correcting [ 18 F]-AV-1451 tau PET data

[ 18 F]-AV-1451 is a leading tracer used with positron emission tomography (PET) to quantify tau pathology. However, [ 18 F]-AV-1451 shows “off target” or non-specific binding, which we define as binding of the tracer in unexpected areas unlikely to harbor aggregated tau based on autopsy literature. Along with caudate, putamen, pallidum and thalamus nonspecific binding, we have found binding in the superior portion of the cerebellar gray matter, leading us to use inferior cerebellar gray as the reference region. We also addressed binding in the posterior portion of the choroid plexus. PET signal unlikely to be associated with tau also occurs in skull, meninges and soft tissue. We refer to [ 18 F]- AV-1451 binding in the skull and meninges as extra-cortical hotspots (ECH) and find them near lateral and medial orbitofrontal, lateral occipital, inferior and middle temporal, superior and inferior parietal, and inferior cerebellar gray matter. Lastly, the choroid plexus also shows nonspecific binding that bleeds into hippocampus. We are providing the code (http://www.runmycode.org/companion/view/2798) used to create different regions of interest (ROIs) that we then used to perform Partial Volume Correction (PVC) using the Rousset geometric transfer matrix method. This method was used in the companion article, “Comparison of multiple tau-PET measures as biomarkers in aging and Alzheimer's Disease” (DOI 10.1016/j.neuroimage.2017.05.058).

59 BASIC BIOLOGICAL SCIENCES↗

White Matter Fractional Anisotropy Correlates With Speed of Processing and Motor Speed in Young Childhood Cancer Survivors

Purpose: To determine whether childhood medulloblastoma and acute lymphoblastic leukemia (ALL) survivors have decreased white matter fractional anisotropy (WMFA) and whether WMFA is related to the speed of processing and motor speed. Methods and Materials: For this study, 17 patients (6 medulloblastoma, 5 ALL treated with high-dose methotrexate (MTX) (4 x 5 g/m{sup 2}) and 6 with low-dose MTX (3 x 2 g/m{sup 2})) and 17 age-matched controls participated. On a 3.0-T magnetic resonance imaging (MRI) scanner, diffusion tensor imaging (DTI) was performed, and WMFA values were calculated, including specific regions of interest (ROIs), and correlated with the speed of processing and motor speed. Results: Mean WMFA in the patient group, mean age 14 years (range 8.9 - 16.9), was decreased compared with the control group (p = 0.01), as well as WMFA in the right inferior fronto-occipital fasciliculus (IFO) (p = 0.03) and in the genu of the corpus callosum (gCC) (p = 0.01). Based on neurocognitive results, significant positive correlations were present between processing speed and WMFA in the splenium (sCC) (r = 0.53, p = 0.03) and the body of the corpus callosum (bCC) (r = 0.52, p = 0.03), whereas the right IFO WMFA was related to motor speed (r = 0.49, p < 0.05). Conclusions: White matter tracts, using a 3.0-T MRI scanner, show impairment in childhood cancer survivors, medulloblastoma survivors, and also those treated with high doses of MTX. In particular, white matter tracts in the sCC, bCC and right IFO are positively correlated with speed of processing and motor speed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Metabolic Imaging Biomarkers of Postradiotherapy Xerostomia

Purpose: Xerostomia is a major complication of head and neck radiotherapy (RT). Available xerostomia measures remain flawed. [{sup 18}F]fluorodeoxyglucose-labeled positron emission tomography-computed tomography (FDG-PET-CT) is routinely used for staging and response assessment of head and neck cancer. We investigated quantitative measurement of parotid gland FDG uptake as a potential biomarker for post-RT xerostomia. Methods and Materials: Ninety-eight locally advanced head and neck cancer patients receiving definitive RT underwent baseline and post-RT FDG-PET-CT on a prospective imaging trial. A separate validation cohort of 14 patients underwent identical imaging while prospectively enrolled in a second trial collecting sialometry and patient-reported outcomes. Radiation dose and pre- and post-RT standard uptake values (SUVs) for all voxels contained within parotid gland ROI were deformably registered. Results: Average whole-gland or voxel-by-voxel models incorporating parotid D{sub Met} (defined as the pretreatment parotid SUV weighted by dose) accurately predicted posttreatment changes in parotid FDG uptake (e.g., fractional parotid SUV). Fractional loss of parotid FDG uptake closely paralleled early parotid toxicity defined by posttreatment salivary output (p < 0.01) and Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer xerostomia scores (p < 0.01). Conclusions: In this pilot series, loss of parotid FDG uptake was strongly associated with acute clinical post-RT parotid toxicity. D{sub Met} may potentially be used to guide function-sparing treatment planning. Prospective validation of FDG-PET-CT as a convenient, quantifiable imaging biomarker of parotid function is warranted and ongoing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A stilbene - CdZnTe based radioxenon detection system

Atmospheric monitoring of radioxenon is one of the most widely used methods by the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) to detect elevated levels of 131m Xe, 133/133m Xe, and 135 Xe. The ratios of these radionuclides help discriminate between peaceful use of nuclear technology and nuclear weapon explosions. Radioxenon detection systems often use plastic scintillators in the capacity of an electron detector and a gas cell, plastic gas cells are responsible for introducing high memory effect in these systems. This work presents the design of a new detection system for radioxenon monitoring that utilizes silicon photomultipliers, a stilbene gas cell, and a CdZnTe detector. This detector was evaluated using xenon radioisotope samples produced in the TRIGA reactor at Oregon State University. Here, a 48-h background was collected and calculations of the Minimum Detectable Concentration (MDC) were carried out using the Region of Interest (ROI) approach. An MDC of less than 1 mBq/m 3 was obtained for 131m Xe, 133 Xe, and 133m Xe in accordance with the sensitivity limits set by the CTBTO and performs respectably when compared to state-of-the-art radioxenon detection systems. Using 131m Xe, this study indicates that the stilbene gas cell exhibits a memory effect of 0.045 ±0.017%, this is almost a two-order magnitude improvement compared to plastic scintillators. The main purpose of this work is to explore the use of new stilbene detection media for radioxenon application and addressing the problem of memory effect.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A kernel machine method for detecting higher order interactions in multimodal datasets: Application to schizophrenia

Technological advances are enabling us to collect multimodal datasets at an increasing depth and resolution while with decreasing labors. Understanding complex interactions among multimodal datasets, however, is challenging. Here in this study, we tested the interaction effect of multimodal datasets using a novel method called the kernel machine for detecting higher order interactions among biologically relevant multimodal data. Using a semiparametric method on a reproducing kernel Hilbert space, we formulated the proposed method as a standard mixed-effects linear model and derived a score-based variance component statistic to test higher order interactions between multimodal datasets. The method was evaluated using extensive numerical simulation and real data from the Mind Clinical Imaging Consortium with both schizophrenia patients and healthy controls. Our method identified 13-triplets that included 6 gene-derived SNPs, 10 ROIs, and 6 gene-specific DNA methylations that are correlated with the changes in hippocampal volume, suggesting that these triplets may be important for explaining schizophrenia-related neurodegeneration. The performance of the proposed method is compared with the following methods: test based on only first and first few principal components followed by multiple regression, and full principal component analysis regression, and the sequence kernel association test. With strong evidence (p-value ≤0.000001), the triplet (MAGI2, CRBLCrus1.L, FBXO28) is a significant biomarker for schizophrenia patients. This novel method can be applicable to the study of other disease processes, where multimodal data analysis is a common task.

59 BASIC BIOLOGICAL SCIENCES↗