Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RF Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Ultra-stable superconducting cavity maser oscillator

An ultra-stable superconducting triple cavity ruby maser oscillator (10) is obtained by providing the oscillator with a superconducting quantum interference device (SQUID) (50), which measures the magnetic field at the ruby (14) and compensates for changes by adjusting the RF pump signal amplitude (42), thereby attaining stabilities of about four orders of magnitude greater than presently attainable.

Strayer, Donald M.↗

Operational Parameters, Considerations, and Design Decisions for Resource-Constrained Ion Trap Mass Spectrometers

Mass spectrometers are increasingly finding applications in new and unique areas, often in situations where key operational resources (i.e. power, weight and size) are limited. One such example is the Mars Organic Molecule Analyzer (MOMA). This instrument is a joint venture between NASA and the European Space Agency (ESA) to develop an ion trap mass spectrometer for chemical analysis on Mars. The constraints on such an instrument are significant as are the performance requirements. While the ideal operating parameters for an ion trap are generally well characterized, methods to maintain analytical performance with limited power and system weight need to be investigated and tested. Methods Experiments have been performed on two custom ion trap mass spectrometers developed as prototypes for the MOMA instrument. This hardware consists of quadrupole ion trap electrodes that are 70% the size of common commercial instrumentation. The trapping RF voltage is created with a custom tank circuit that can be tuned over a range of RF frequencies and is driven using laboratory supplies and amplifiers. The entire instrument is controlled with custom Lab VIEW software that allows a high degree of flexibility in the definition of the scan function defining the ion trap experiment. Ions are typically generated via an internal electron ionization source, however, a laser desorption source is also in development for analysis of larger intact molecules. Preliminary Data The main goals in this work have been to reduce the power required to generate the radio frequency trapping field used in an ion trap mass spectrometer. Generally minimizing the power will also reduce the volume and mass of the electronics to support the instrument. In order to achieve optimum performance, commercial instruments typically utilize RF frequencies in the 1 MHz range. Without much concern for power usage, they simply generate the voltage required to access the mass range of interest. In order to reduce the required RF voltage (and power), operation of the ion trap at lower RF frequencies has been investigated. Surprisingly, the performance of the instrument has only been slightly degraded at RF frequencies all the way down to 500 kHz. Mass resolution is relatively stable to this point and depending on the resonant ejection point used, the peak intensity is also quite stable. To date only masses up to m/z 200 have been fully investigated, however, additional studies are planned to verify the performance with higher mass ions. The lower frequency and voltage should reduce the pseudo potential well depth, eventually affecting the trapping efficiency of the instrument -- effect that could manifest itself in significantly limiting the mass range of trapped ions. Other methods to reduce the RF power while maintaining analytical performance are also under investigation. This includes ion ejection at lower q(sub z) values to access a given mass with a lower RF voltage. The loss of mass resolution at lower q(sub eject) points has been measured and current work is underway to leverage scan speed and the use of non-linear resonances in order to counter this trend. The overall trap performance under this range of operating conditions will be presented with a goal of identifying what trade-offs are acceptable.

Danell, Ryan M.↗

Core Analysis Combining MT (TIPPER) and Dielectric Sensors (Sans EC) in Earth and Space

On terrestrial planets and moons of our solar system cores reveal details about a geological structure's formation, content, and history. The strategy for the search for life is focused first on finding water which serves as a universal solvent, and identifying the rocks which such solvent act upon to release the constituent salts, minerals, ferrites, and organic compounds and chemicals necessary for life. Dielectric spectroscopy measures the dielectric properties of a medium as a function of frequency. Reflection measurements in the frequency range from 300 kHz to 300 MHz were carried out using RF and microwave network analyzers interrogating SansEC Sensors placed on clean geological core samples. These were conducted to prove the concept feasibility of a new geology instrument useful in the field and laboratory. The results show that unique complex frequency spectra can be acquired for a variety of rock core samples. Using a combination of dielectric spectroscopy and computer simulation techniques the magnitude and phase information of the frequency spectra can be converted to dielectric spectra. These low-frequency dielectric properties of natural rock are unique, easily determined, and useful in characterizing geology. TIPPER is an Electro-Magnetic Passive-Source Geophysical Method for Detecting and Mapping Geothermal Reservoirs and Mineral Resources. This geophysical method uses distant lightning and solar wind activity as its energy source. The most interesting deflections are caused by the funneling of electrons into more electrically conductive areas like mineralized faults, water or geothermal reservoirs. We propose TIPPER to be used with SansEC for determining terrain/ocean chemistry, ocean depth, geomorphology of fracture structures, and other subsurface topography characteristics below the ice crust of Jovian moons. NASA envisions lander concepts for exploration of these extraterrestrial icy surfaces and the oceans beneath. One such concept would use a nuclear powered heated tip for melting through the ice sheath of Europa and inserting a down hole SansEC with TIPPER interface. NASA's Juno space probe already on the way to Jupiter as part of the Exploration New Frontiers Program and the planned Europa mission will conduct detailed reconnaissance of Jupiter's moon Europa and investigate whether the icy moon could harbor conditions suitable for life. It has already been observed that Jovian moons have auroras that may serve as naturally occurring active energy sources for a TIPPER instrument.

Mound, Michael C.↗

Experiment and numerical simulation of RF heating in the Tandem Mirror plasma propulsion device

Recent results of experimental and theoretical studies of ICRF heating of the plasma in the Tendem Mirror rocket are presented. The radial and axial profile of the magnetic field of the wave have been measured, and the data agree with the results from numerical simulation. One very important new finding is that the wave damped when it approached the resonance plane. This is a strong indication of beach heating effect and that RF power is absorbed by the ions in the plasma as expected. This power absorption phenomenon was also further confirmed by the refined analytical study of the wave propagation in a slab model. The electron density in the central cell has been measured by a microwave interferometer. The existence of two types of discharge similar to those of H-alpha emission have also been observed from the density measurements. A preliminary design of a flight system for a 100-day Mars transit has been undertaken. The specific weight for a 10 MW rocket is only 0.04 kg/kW.

Yang, T. F.↗

Coded 16-CPFSK for downlink applications

A bandwidth-efficient constant-envelope Proof-of-Concept (POC) modem is described. The modem was developed on an Advanced Modulation Techniques Development contract for the NASA/Lewis Research Center. The POC modem employs 16-ary Continuous Phase Frequency Shift Keying (16-CPFSK) modulation. The 16 frequencies are spaced every 1/16th baud rate which produces a compact spectrum allowing 2 bits/sec/Hz operation. The modem is designed for 200 mb/s Time Division Multiple Access (TDMA) application with 100 MHz adjacent channel spacing. Overall rate 3.4 convolutional coding is incorporated. The demodulator differs significantly from typical quadrature phase detector approaches in that phase is coherently measured by processing the baseband output of a frequency discriminator. Baud rate phase samples for the baseband processor are subsequently decoded to yield the original data stream. The method of encoding onto the 16-ary symbol-ending phase nodes, together with convolutional coding gain, results in near Quadrature Phase Shift Keying (QPSK) theoretical performance. The modulated signal is of constant envelope; thus the power amplifier can be saturated for peak performance. The spectrum is inherently bandlimited and requires no RF filter for sidelobe containment. Two novel theoretical techniques are used in this 16-CPFSK modem: (1) coherent phase measurements are obtained by processing an FM discriminator baseband output; and (2) modulation is accomplished via a closed-loop-linearized voltage controlled oscillator (VCO).

Davis, Robert↗

UCMS - A new signal parameter measurement system using digital signal processing techniques

The User Constraint Measurement System (UCMS) is a hardware/software package developed by NASA Goddard to measure the signal parameter constraints of the user transponder in the TDRSS environment by means of an all-digital signal sampling technique. An account is presently given of the features of UCMS design and of its performance capabilities and applications; attention is given to such important aspects of the system as RF interface parameter definitions, hardware minimization, the emphasis on offline software signal processing, and end-to-end link performance. Applications to the measurement of other signal parameters are also discussed.

Choi, H. J.↗

The ATS-F interferometer - A precision wide field-of-view attitude sensor

An RF phase interferometer has been integrated into the ATS-F spacecraft attitude control system. Laboratory measurements indicate that the interferometer is capable of determining spacecraft attitude in pitch and roll to an accuracy of 0.18 deg over a field-of-view of plus or minus 12.5 deg about the spacecraft normal axis with an angular resolution of 0.004 deg. The system is completely solid state, weighs 17 pounds, and consumes 12.5 W of DC power.

Teichman, M. A.↗

Radio frequency fields generated by the S-band communication link on OV102

The Space Shuttle STS-3 mission carried a Plasma Diagnostics Package (PDP) whose instrumentation included an S-band antenna and detector. The PDP was maneuvered by the Remote Manipulator System arm through a computer controlled sequence in the Orbiter's X-Z plane, above the quad and hemi S-band communications antennas. Antenna field strength measurements were conducted during transmitter high power modes, and the results were compared to ground full scale measurements and predictions. A field strength 4.8 + or - 3 dB higher than predicted is noted. This RF field is primarily due to the quad PM transmitter, whose power output of 115 W compares with 15 W for the hemi.

Murphy, G. B.↗

Performance measurements for a laboratory-simulated 30/20 GHz communication satellite transponder

NASA has developed a digital satellite communications system simulator and test bed facility, known as the Systems Integration, Test and Evaluation (SITE) Project. The purpose of the facility is to evaluate satellite system components, develop and verify system concepts, and perform satellite system experiments. A recently completed set of experiments measured the performance of the 30/20 GHz satellite transponder portion of the system in terms of RF parameters and high rate digital data transmission. The results of these tests indicate the quality of data transmission which can be obtained under various transponder conditions, as well as the relative effects of degraded RF performance on the bit-error rate (BER) of transmitted data.

Kerczewski, Robert J.↗

Performance measurements for a laboratory-simulated 30/20 GHz communication satellite transponder

NASA has developed a digital satellite communications system simulator and test bed facility, known as the SITE (System Integratrion, Test and Evaluation) Project. The purpose of the facility is to evaluate satellite system components, develop and verify system concepts, and perform satellite system experiments. A recently completed set of experiments measured the performance of the 30/20 GHz satellite transponder portion of the system in terms of RF parameters and high rate digital data transmission. The results of these tests indicate the quality of data transmission which can be obtained under various transponder operating conditions, as well as the relative effects of degraded RF performance on the bit-error rate (BER) of transmitted data.

Kerczewski, Robert J.↗

End-loaded crossed-slot radiating elements

Three cavity-backed crossed-slot antenna configurations are described that offer simple design, easy frequency tuning, light weight, low loss, and low cost. These antennas are designed for mobile satellite (MSAT) vehicle phased-array applications. The slots in these antennas are end-loaded. The end loading makes the slots effectively longer, and hence reduces their resonant frequency. Therefore, relatively small radiating elements can be achieved for large-angle-scanning phased-array antennas. These antennas have good RF characteristics and provide a relatively wide bandwidth without needing external tuning circuits for impedance matching. Measurements for the return loss and the far-field pattern of these antennas are presented.

Manshadi, F.↗

Measurement of satellite PCS fading using GPS

A six-channel commercial GPS receiver with a custom-made 40 deg tilted, rotating antenna has been assembled to make fade measurements for personal satellite communications. The system can measure up to two times per minute fades of up to 15 dB in the direction of each tracked satellite from 10 to 90 deg elevation. Photographic fisheye lens images were used to categorize the fade data obtained in several test locations according to fade states of clear, shadowed, or blocked. Multipath effects in the form of annular rings can be observed when most of the sky is clear. Tree fading by a Pecan exceeding 3.5 dB and 12 dB at 50 to 10 percent probability, respectively, compared with median fades of 7.5 dB measured earlier and the discrepancy is attributed to the change in ratio when measuring over an area as opposed to along a line. Data acquired inside buildings revealed 'rf-leaky' ceilings. Satellite diversity gain in a shadowed environment exceeded 6 dB at the 10 percent probability.

Vogel, Wolfhard J.↗

Fast, high sensitivity dewpoint hygrometer

A dewpoint/frostpoint hygrometer that uses a surface moisture-sensitive sensor as part of an RF oscillator circuit with feedback control of the sensor temperature to maintain equilibrium at the sensor surface between ambient water vapor and condensed water/ice. The invention is preferably implemented using a surface acoustic wave (SAW) device in an RF oscillator circuit configured to generate a condensation-dependent output signal, a temperature sensor to measure the temperature of the SAW device and to distinguish between condensation-dependent and temperature-dependent signals, a temperature regulating device to control the temperature of the SAW device, and a feedback control system configured to keep the condensation-dependent signal nearly constant over time in the presence of time-varying humidity, corrected for temperature. The effect of this response is to heat or cool the surface moisture-sensitive device, which shifts the equilibrium with respect to evaporation and condensation at the surface of the device. The equilibrium temperature under feedback control is a measure of dewpoint or frostpoint.

Hoenk, Michael E.↗

Electron Heating and Quasiparticle Tunnelling in Superconducting Charge Qubits

We have directly measured non-equilibrium quasiparticle tunnelling in the time domain as a function of temperature and RF carrier power for a pair of charge qubits based on the single Cooper-pair box, where the readout is performed with a multiplexed quantum capacitance technique. We have extracted an effective electron temperature for each applied RF power, using the data taken at the lowest power as a reference curve. This data has been fit to a standard T? electron heating model, with a reasonable correspondence with established material parameters.

Single Cooper Pair Box↗

Light Detection and Ranging (LIDAR) From Space - Laser Altimeters

Light detection and ranging, or lidar, is like radar but atoptical wavelengths. The principle of operation and theirapplications in remote sensing are similar. Lidars havemany advantages over radars in instrument designs andapplications because of the much shorter laser wavelengthsand narrower beams. The lidar transmitters and receiveroptics are much smaller than radar antenna dishes. Thespatial resolution of lidar measurement is much finer thanthat of radar because of the much smaller footprint size onground. Lidar measurements usually give a better temporalresolution because the laser pulses can be much narrowerthan radio frequency (RF) signals. The major limitation oflidar is the ability to penetrate clouds and ground surfaces.

Sun, Xiaoli↗

Mass quantity gauging by RF mode analysis

Work done to date is reported concerning Radio Frequency Mass Quantity Gauging. Experimental apparatus has been designed and tested which measures the resonant frequencies of a tank in the time domain. These frequencies correspond to the total mass of fluid within the tank. Experimental results are discussed for nitrogen and hydrogen in normal gravity both in the supercritical state and also in the two phase (liquid-gas) region. Theoretical discussions for more general cases are given.

Collier, R. S.↗

Progress Towards High-Sensitivity Arrays of Detectors of Sub-mm Radiation Using Superconducting Tunnel Junctions with Integrated Radio Frequency Single-Electron Transistors

For high resolution imaging and spectroscopy in the FIR and submillimeter, space observatories will demand sensitive, fast, compact, low-power detector arrays with 104 pixels and sensitivity less than 10(exp -20) W/Hz(sup 0.5). Antenna-coupled superconducting tunnel junctions with integrated rf single-electron transistor readout amplifiers have the potential for achieving this high level of sensitivity, and can take advantage of an rf multiplexing technique. The device consists of an antenna to couple radiation into a small superconducting volume and cause quasiparticle excitations, and a single-electron transistor to measure current through junctions contacting the absorber. We describe optimization of device parameters, and results on fabrication techniques for producing devices with high yield for detector arrays. We also present modeling of expected saturation power levels, antenna coupling, and rf multiplexing schemes.

Stevenson, T. R.↗

Microwave radiometer for subsurface temperature measurement

A UHF radiometer, operating at a frequency of 800 MHz, was modified to provide an integral, three frequency voltage standing wave ratio (VSWR) circuit in the radio frequency (RF) head. The VSWR circuit provides readings of power transmission at the antenna-material interface with an accuracy of plus or minus 5 percent. The power transmission readings are numerically equal to the emissivity of the material under observation. Knowledge of material emissivity is useful in the interpretation of subsurface apparent temperatures obtained on phantom models of biological tissue. The emissivities of phantom models consisting of lean beefsteak were found to lie in the range 0.623 to 0.779, depending on moisture content. Radiometric measurements performed on instrumented phantoms showed that the radiometer was capable of sensing small temperature changes occurring at depths of at least 19 to 30 mm. This is consistent with previously generated data which showed that the radiometer could sense temperatures at a depth of 38 mm.

Porter, R. A.↗