Removal Of Nitric Oxide From Different Mixtures Of Gases Using Dielectric Barrier Discharge

Dielectric barrier discharge (DBD) is employed in this project as the processing medium to remove nitric oxide in gas stream. Gas stream containing different components was released continuously into a series of dielectric barrier discharge cells and the output gas was analyzed using a chemiluminescence's type NO analyzer. Almost complete removal (more than 99%) of NO was observed when the gas stream contained only NO and nitrogen. In the presence of SO{sub 2}, the removal rate was decreased to as low as 70%. Adding air into the stream gave a more erratic results. The removal rate was also affected by the number of DBD cell used and the flow rate of the input gas. However, In this paper, only results using 2 cells whilst varying the flow rate are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A high-speed photoresist removal process using multibubble microwave plasma under a mixture of multiphase plasma environment

This paper proposes a photoresist removal process that uses multibubble microwave plasma produced in ultrapure water. A non-implanted photoresist and various kinds of ion-implanted photoresists such as B, P, and As were treated with a high ion dose of 5 × 10{sup 15} atoms/cm{sup 2} at an acceleration energy of 70 keV; this resulted in fast removal rates of more than 1 μm/min. When the distance between multibubble microwave plasma and the photoresist film was increased by a few millimeters, the photoresist removal rates drastically decreased; this suggests that short-lived radicals such as OH affect high-speed photoresist removal.

36 MATERIALS SCIENCE↗

The mechanics of motorised momentum exchange tethers when applied to active debris removal from LEO

The concept of momentum exchange when applied to space tethers for propulsion is well established, and a considerable body of literature now exists on the on-orbit modelling, the dynamics, and also the control of a large range of tether system applications. The authors consider here a new application for the Motorised Momentum Exchange Tether by highlighting three key stages of development leading to a conceptualisation that can subsequently be developed into a technology for Active Debris Removal. The paper starts with a study of the on-orbit mechanics of a full sized motorised tether in which it is shown that a laden and therefore highly massasymmetrical tether can still be forced to spin, and certainly to librate, thereby confirming its possible usefulness for active debris removal (ADR). The second part of the paper concentrates on the modelling of the centripetal deployment of a symmetrical MMET in order to get it initialized for debris removal operations, and the third and final part of the paper provides an entry into scale modelling for low cost mission design and testing. It is shown that the motorised momentum exchange tether offers a potential solution to the removal of large pieces of orbital debris, and that dynamic methodologies can be implemented to in order to optimise the emergent design.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nitrate removal performance of Diaphorobacter nitroreducens using biodegradable plastics as the source of reducing power

Strain NA10B{sup T} and other two strains of the denitrifying betaproteobacterium Diaphorobacter nitroreducens were studied for the performance of solid-phase denitrification (SPD) using poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHBV) and some other biodegradable plastics as the source of reducing power in wastewater treatment. Sequencing-batch SPD reactors with these organisms and PHBV granules or flakes as the substrate exhibited good nitrate removal performance. Vial tests using cultures from these parent reactors showed higher nitrate removal rates with PHBV granules (ca. 20 mg-NO{sub 3}{sup −}‐N g{sup −1} [dry wt cells] h{sup −1}) than with PHBV pellets and flakes. In continuous-flow SPD reactors using strain NA10B{sup T} and PHBV flakes, nitrate was not detected even at a loading rate of 21 mg-NO{sub 3}{sup −}‐N L{sup −1} h{sup −1}. This corresponded to a nitrate removal rate of 47 mg-NO{sub 3}{sup −}‐N g{sup −1} (dry wt cells) h{sup −1}. In the continuous-flow reactor, the transcription level of the phaZ gene, coding for PHB depolymerase, decreased with time, while that of the nosZ gene, involved in denitrificaiton, was relatively constant. These results suggest that the bioavailability of soluble metabolites as electron donor and carbon sources increases with time in the continuous-flow SPD process, thereby having much higher nitrate removal rates than the process with fresh PHBV as the substrate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low Power Thermal Tuning in Resonant Vertical Junction Silicon Modulators Through Substrate Removal

We report on thermally tunable modulators, with efficiencies up to 2.16 nm/mW. Efficient performance was accomplished through integrated heater design and Si substrate removal, where the heavily N+ doped Si heater element is integrated into the body of the microdisk. For comparison, modulators with an external heater design were also tested with small diameter Si substrate removed. The external heavily doped N+Si heater bars were fabricated outside the diameter of the microdisk. Efficiency for external heater design was 0.68 nm/mW with substrate removed. Both types of thermal modulators were experimentally tested and simulated for a complete understanding of the Si substrate's influence on heat dissipation with both types benefiting significantly from substrate removal. Agreement between simulation and experimental results was greater than 80% in all instances.

42 ENGINEERING↗

Damaged silicon contact layer removal using atomic layer etching for deep-nanoscale semiconductor devices

Silicon atomic layer etching (ALET) using Cl{sub 2} is applied to remove the damaged layer on a 30 nm contact silicon surface formed by high-energy reactive ions during high aspect ratio contact etching, and its effects on the damage removal characteristics are investigated. Compared to a conventional damage removal method, such as the low-power CF{sub 4} plasma treatment technique, ALET produces less secondary damage to the substrate and gives exact etch depth control and extremely high etch selectivity to the contact SiO{sub 2} insulating pattern mold. When ALET is applied after a conventional damage removal technique, the sheet resistance of the damaged contact silicon surface is improved to a level close to that of a clean silicon surface, while exact atomic-scale depth control is maintained without changes in the pattern mold profile.

36 MATERIALS SCIENCE↗

Native oxide transport and removal during the atomic layer deposition of Ta{sub 2}O{sub 5} on InAs(100) surfaces

Atomic layer deposition (ALD) was used to deposit Ta{sub 2}O{sub 5} on etched and native oxide-covered InAs(100) using pentakis dimethyl amino tantalum and H{sub 2}O at 200–300 °C. The transport and removal of the native oxides during the ALD process was investigated using x-ray photoelectron spectroscopy (XPS). Depositions above 200 °C on etched surfaces protected the interface from reoxidation. On native oxide-covered surfaces, depositions resulted in enhanced native oxide removal at higher temperatures. The arsenic oxides were completely removed above 250 °C after 3 nm of film growth, but some of the As{sub 2}O{sub 3} remained in the film at lower temperatures. Angle-resolved and sputter depth profiling XPS confirmed indium and arsenic oxide migration into the Ta{sub 2}O{sub 5} film at deposition temperatures as low as 200 °C. Continuous removal of both arsenic and indium oxides was confirmed even after the deposition of several monolayers of a coalesced Ta{sub 2}O{sub 5} film, and it was demonstrated that native oxide transport is a prevalent component of the interface “clean-up” mechanism.

36 MATERIALS SCIENCE↗

Removal Rate Model for Magnetorheological Finishing of Glass

Magnetorheological finishing (MRF) is a deterministic subaperture polishing process. The process uses a magntorheological (MR) fluid that consists of micrometer-sized, spherical, magnetic carbonyl iron (CI) particles, nonmagnetic polishing abrasives, water, and stabilizers. Material removal occurs when the CI and nonmagnetic polishing abrasives shear material off the surface being polished. We introduce a new MRF material removal rate model for glass. This model contains terms for the near surface mechanical properties of glass, drag force, polishing abrasive size and concentration, chemical durability of the glass, MR fluid pH, and the glass composition. We introduce quantitative chemical predictors for the first time, to the best of our knowledge, into an MRF removal rate model. We validate individual terms in our model separately and then combine all of the terms to show the whole MRF material removal model compared with experimental data. All of our experimental data were obtained using nanodiamond MR fluids and a set of six optical glasses.

36 MATERIALS SCIENCE↗

Demonstrate the removal efficiency and capacity of MOF materials for krypton recovery

Metal organic framework materials (MOFs) were developed and tested in support of the U.S. Department of Energy Office of Nuclear Energy, Fuel Cycle Technology Separations and Waste Forms Campaign. Specifically, materials are being developed for the removal of xenon (Xe) and krypton (Kr) from gaseous products of nuclear fuel reprocessing unit operations. Two metal organic framework structures were investigated in greater detail to demonstrate the removal efficiency and capacity of MOF materials for krypton recovery. Our two bed breakthrough measurements on NiDOBDC and FMOFCu indicate these materials can capture and separate parts per million levels of Xe and Kr from air. The removal efficiency and adsorption capacity for Kr on these two MOFs were further increased upon removal of Xe upfront.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pre-Conceptual Design for Northstar ⁹⁹Mo Process Tritium Removal System

In this report we describe a preliminary concept for a Tritium Removal System (TRS) to remove tritium that is generated in the ⁹⁹Mo production process. Preliminary calculations have been performed to evaluate an approximate size for the system. The concept described utilizes well-established detritiation technology based on catalytic oxidation of tritium and tritiated hydrocarbons to water in a high temperature (400 °C) reactor and capture of water in a molecular sieve bed. The TRS concept involves use of a single system that would cycle through each of the seven online target systems and remove tritium that has been accumulated after one week’s run time. The TRS would perform cleanup operations on each target system for a period of approximately 24 hours. This would occur while the system is still online and just prior to target replacement, so tritium levels would at their minimum values for target replacement. In the concept, during normal operation a small fraction (1%) of the helium recirculating in the system would be diverted through the TRS and returned to the flow loop. With this approach sufficient levels of detritiation can be accomplished in a 24 hour period. In the study it was found that because of the need to maintain low oxygen levels in the system (<100 ppm) this increases the size of the catalytic reactor. As a result of this finding, consideration should be given to other methods for removing tritium from the system. Other methods such as catalytic exchange of tritium with an unsaturated organic compound and subsequent trapping on activated carbon or molecular sieve could offer advantages of reducing reactor size and operation at lower reactor temperature. However the most significant advantage of such an approach would be the ability to operate in very low oxygen environments, which would eliminate any concerns for oxidation of the target.

07 ISOTOPE AND RADIATION SOURCES↗

Standard Waste Box Lid Screw Removal Option Testing

This report provides results from test work conducted to resolve the removal of screws securing the standard waste box (SWB) lids that hold the remediated nitrate salt (RNS) drums. The test work evaluated equipment and process alternatives for removing the 42 screws that hold the SWB lid in place. The screws were secured with a red Loctite thread locker that makes removal very difficult because the rivets that the screw threads into would slip before the screw could be freed from the rivet, making it impossible to remove the screw and therefore the SWB lid.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preliminary Evaluation of Removing Used Nuclear Fuel from Shutdown Sites

A preliminary evaluation of removing spent nuclear fuel (SNF) from 13 shutdown nuclear power reactor sites was conducted. At these shutdown sites the nuclear power reactors have been permanently shut down and the sites have been decommissioned or are undergoing decommissioning. The shutdown sites were Maine Yankee, Yankee Rowe, Connecticut Yankee, Humboldt Bay, Big Rock Point, Rancho Seco, Trojan, La Crosse, Zion, Crystal River, Kewaunee, San Onofre, and Vermont Yankee. The evaluation was divided into four components: (1) characterization of the SNF and greater-than-Class C low-level radioactive waste (GTCC waste) inventory, (2) a description of the on-site infrastructure and conditions relevant to transportation of SNF and GTCC waste, (3) an evaluation of the near-site transportation infrastructure and experience relevant to shipping transportation casks containing SNF and GTCC waste, including identification of gaps in information, and (4) an evaluation of the actions necessary to prepare for and remove SNF and GTCC waste. Every site was found to have at least one off-site transportation mode option for removing its SNF and GTCC waste; some have multiple options. Experience removing large components during reactor decommissioning provided an important source of information used to identify the transportation mode options for the sites. Especially important in conducting the evaluation were site visits, through which information was obtained that would not have been available otherwise. Extensive photographs taken during the site visits proved to be particularly useful in documenting the current conditions at or near the sites. It is expected that additional site visits will be conducted to add to the information presented in the evaluation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of electrostatic precipitator (ESP) technology to remove elemental mercury vapor, HG(0)

The presence of mercury vapor or other forms of mercury presents issues with worker safety, decommissioning facilities, and environmental impacts. As such, it is desired to develop a strategy to either remove or reduce mercury levels in Oak Ridge’s Y-12 Complex facilities. A testing methodology was developed to evaluate electrostatic precipitator technology for removal of mercury vapor. This methodology involved supplying mercury vapor-containing air to the ESP device by flowing air through a column containing alternating layers of sand and liquid mercury droplets. Initial attempts at quantifying the efficacy of the ESP device in removing mercury vapor were plagued with difficulties in controlling the flow of mercury into the ESP device due to poor performance of the generator column and the contamination of these experiments with mercury from an unknown source. These issues were resolved by creating a new generator column with slower air velocity and higher surface area of liquid mercury, along with moving the air intake for the ESP device to outside of the chemical hood in which testing took place. This resulted in a steady, quantified flow of mercury vapor from the generator column and no observation of unintended mercury sources. A final test of the ESP device under these controlled conditions showed that for a certain amount of time (on the order of 20-30 minutes) mercury concentrations were reduced by approximately 33 - 67% of the inlet concentration. However, episodic releases or pulses of mercury observed only at the outlet indicated that the mercury accumulated in the ESP device is periodically expelled. As a result, it was not deemed to be an efficient strategy for the removal of elemental mercury vapor.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

REMOVAL OF IODIDE FROM GROUNDWATER USING SILVER CHLORIDE WHITE PAPER

Releases from the F and H Area Seepage Basins on the Savannah River Site (SRS) have caused groundwater plumes that contain a variety of contaminants. These plumes are releasing contaminants into Fourmile Branch, which is a small tributary of the Savannah River. The metallic contaminant releases to the branch are being controlled by base injection. The base injection targets cationic contaminants and was not intended to reduce the concentration of I-129 in groundwater. SRS and the regulatory agencies believe it is appropriate to investigate remedial alternatives that could reduce the I-129. The Savannah River Site Area Closures Projects (ACP) and the Savannah River National Laboratory (SRNL) are developing an innovative in situ treatment for I-129 using silver chloride (AgCl). The proposed AgCl amendment has a very small particle size and is designed to be injected into the contaminated aquifer to capture I-129. The solubility of AgI is several orders of magnitude lower than the solubility of AgCl. Thus, when I-129 comes in contact with AgCl it forms silver iodide (AgI), which is very stable and essentially insoluble in water. SRNL has been performing bench-scale column tests on the effectiveness of silver chloride to capture iodine in an aqueous solution. These initial tests evaluate silver chloride in four different particle sizes; 4-5 millimeters (standard reagent silver chloride), approximately 1 millimeters (sieved reagent silver chloride), approximately 2 micrometers (ultra fine grind without a grinding agent), and <1 micrometer (ultra fine grind with a grinding agent). The first two experiments with macro-sized particles were proof of principle tests. In these the AgCl was mechanically mixed into a portion of the soil filling the columns. The last two were to test the effectiveness of injecting particles suspended in an aqueous solution--the ability to inject the particles, their retention in the column and their effectiveness at removing dissolved iodide from solution. The amendments for these two columns were obtained from a private company specializing in ultra-fine grinding of materials. They were ground in propylene glycol because when ground in water silver metal electroplated onto the steel grinding equipment. Table 1 shows the list of columns and the amendment characteristics. The results of these column experiments demonstrate that solid silver chloride is highly effective at removing dissolved iodine from water and should be an effective amendment for removing I-129 from groundwater. Based on known groundwater chemistry and the reaction of AgCl with I- to produce AgI, the only interference will be natural dissolved stable iodine (I-127). Millings et al. (2002) reported a maximum I-127 concentration of 2.2 ug/L in groundwater from well P-27D, a background water table well near F-Area. The concentration of dissolved iodide used in these experiments is approximately 4500 times this natural concentration. Therefore, a AgCl amendment in the subsurface at the same concentration used in these experiments, might effectively remove I-129 for up to 4500 times the number of pore volumes of groundwater as observed here. This assumes homogeneous distribution of the amendment and no occlusion by other minerals in the subsurface. The only reliable way to evaluate these effects is by trial in the field. The column studies also suggest that the amendment is readily injectable into sediments, but will not be highly mobile. The fact that the effluent from Column 4 shows no iodide breakthrough after nearly 11 pore volumes indicates that some of the injected AgCl was trapped in the column. A mass balance on iodide reacted so far suggests that a minimum of 0.056 grams of silver chloride was trapped in the column to react with the iodide. This is 5.6% of the mass injected. Assume the 1-foot column represents the first foot of sediment in the subsurface into which the amendment is injected. If 5.6% of the AgCl particles are trapped in each subsequent foot of sediment through which the injectate moves, at 100 feet the concentration of particles will be 3% of the injection concentration. This is the maximum possible concentration indicated by these column studies, because far more AgCl may have been trapped in the column. Continued data collection will tell how much more. Dissolved silver concentrations from the silver chloride amendment will be low. Effluent from Column 1 was analyzed for dissolved silver and the concentrations were below the detection limit of 0.2 mg/L.

36 MATERIALS SCIENCE↗

100-KE REACTOR CORE REMOVAL PROJECT ALTERNATIVE ANALYSIS WORKSHOP REPORT

On December 15-16, 2009, a 100-KE Reactor Core Removal Project Alternative Analysis Workshop was conducted at the Washington State University Consolidated Information Center, Room 214. Colburn Kennedy, Project Director, CH2M HILL Plateau Remediation Company (CHPRC) requested the workshop and Richard Harrington provided facilitation. The purpose of the session was to select the preferred Bio Shield Alternative, for integration with the Thermal Shield and Core Removal and develop the path forward to proceed with project delivery. Prior to this workshop, the S.A. Robotics (SAR) Obstruction Removal Alternatives Analysis (565-DLV-062) report was issued, for use prior to and throughout the session, to all the team members. The multidisciplinary team consisted ofrepresentatives from 100-KE Project Management, Engineering, Radcon, Nuclear Safety, Fire Protection, Crane/Rigging, SAR Project Engineering, the Department of Energy Richland Field Office, Environmental Protection Agency, Washington State Department of Ecology, Defense Nuclear Facility Safety Board, and Deactivation and Decommission subject matter experts from corporate CH2M HILL and Lucas. Appendix D contains the workshop agenda, guidelines and expectations, opening remarks, and attendance roster going into followed throughout the workshop. The team was successful in selecting the preferred alternative and developing an eight-point path forward action plan to proceed with conceptual design. Conventional Demolition was selected as the preferred alternative over two other alternatives: Diamond Wire with Options, and Harmonic Delamination with Conventional Demolition. The teams preferred alternative aligned with the SAR Obstruction Removal Alternative Analysis report conclusion. However, the team identified several Path Forward actions, in Appendix A, which upon completion will solidify and potentially enhance the Conventional Demolition alternative with multiple options and approaches to achieve project delivery. In brief, the Path Forward was developed to reconsider potential open air demolition areas; characterize to determine if any zircaloy exists, evaluate existing concrete data to determine additional characterization needs, size the new building to accommodate human machine interface and tooling, consider bucket thumb and use ofshape-charges in design, and finally to utilize complex-wide and industry explosive demolition lessons learned in the design approach. Appendix B documents these results from the team's use ofValue Engineering process tools entitled Weighted Analysis Alternative Matrix, Matrix Conclusions, Evaluation Criteria, and Alternative Advantages and Disadvantages. These results were further supported with the team's validation of parking-lot information sheets: memories (potential ideas to consider), issues/concerns, and assumptions, contained in Appendix C. Appendix C also includes the recorded workshop flipchart notes taken from the SAR Alternatives and Project Overview presentations. The SAR workshop presentations, including a 3-D graphic illustration demonstration video have been retained in the CHPRC project file, and were not included in this report due to size limitations. The workshop concluded with a round robin close-out where each member was engaged for any last minute items and meeting utility. In summary, the team felt the session was value added and looked forward to proceeding with the recommended actions and conceptual design.

36 MATERIALS SCIENCE↗

Synthesis and Characterization of Silver-Modified Nanoporous Silica Materials for Enhanced Iodine Removal

In aquatic environments, the presence of iodine species, including radioactive isotopes like 129 I and I 2 , poses significant environmental and health concerns. Iodine can enter water resources from various sources, including nuclear accidents, medical procedures, and natural occurrences. To address this issue, the use of natural occurring nanoporous minerals, such as zeolitic materials, for iodine removal will be explored. This study focuses on the adsorption of iodine by silver-modified zeolites (13X-Ag, 5A-Ag, Chabazite-Ag, and Clinoptilolite-Ag) and evaluates their performance under different conditions. All materials were characterized using scanning electron microscopey (SEM), energy-dispersive X-ray spectroscopy (EDS), powdered X-ray diffraction (P-XRD), Fourier-transform infrared spectrometry (FTIR), and nitrogen adsorption studies. The results indicate that Chabazite-Ag exhibited the highest iodine adsorption capacity, with an impressive 769 mg/g, making it a viable option for iodine removal applications. 13X-Ag and 5A-Ag also demonstrated substantial adsorption capacities of 714 mg/g and 556 mg/g, respectively, though their behavior varied according to different models. In contrast, Clinoptilolite-Ag exhibited strong pH-dependent behavior, rendering it less suitable for neutral to slightly acidic conditions. Furthermore, this study explored the impact of ionic strength on iodine adsorption, revealing that Chabazite-Ag is efficient in low-salinity environments with an iodine adsorption capacity of 51.80 mg/g but less effective in saline conditions. 5A-Ag proved to be a versatile option for various water treatments, maintaining its iodine adsorption capacity across different salinity levels. In contrast, Clinoptilolite-Ag exhibited high sensitivity to ionic competition, virtually losing its iodine adsorption ability at a NaCl concentration of 0.1 M. Kinetic studies indicated that the pseudo-second-order model best describes the adsorption process, suggesting chemisorption mechanisms dominate iodine removal. Chabazite-Ag exhibited the highest initial adsorption rate with a k 2 value of 0.002 mg g -1 h -1 , emphasizing its superior adsorption capabilities. Chabazite and Clinoptilolite, naturally occurring minerals, provide eco-friendly solutions for iodine adsorption. Chabazite superior iodine removal highlights its value in critical applications and its potential for addressing pressing environmental challenges.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SLUDGE HEEL REMOVAL BY ALUMINUM DISSOLUTION AT SAVANNAH RIVER SITE 12390

High Level Waste (HLW) at the Savannah River Site (SRS) is currently stored in aging underground storage tanks. This waste is a complex mixture of insoluble solids, referred to as sludge, and soluble salts. Continued long-term storage of these radioactive wastes poses an environmental risk. Operations are underway to remove and disposition the waste, clean the tanks and fill with grout for permanent closure. Heel removal is the intermediate phase of the waste retrieval and tank cleaning process at SRS, which is intended to reduce the volume of waste prior to treatment with oxalic acid. The goal of heel removal is to reduce the residual amount of radioactive sludge wastes to less than 37,900 liters (10,000 gallons) of wet solids. Reducing the quantity of residual waste solids in the tank prior to acid cleaning reduces the amount of acid required and reduces the amount of excess acid that could impact ongoing waste management processes. Mechanical heel removal campaigns in Tank 12 have relied solely on the use of mixing pumps that have not been effective at reducing the volume of remaining solids. The remaining waste in Tank 12 is known to have a high aluminum concentration. Aluminum dissolution by caustic leaching was identified as a treatment step to reduce the volume of remaining solids and prepare the tank for acid cleaning. Dissolution was performed in Tank 12 over a two month period in July and August, 2011. Sample results indicated that 16,440 kg of aluminum oxide (boehmite) had been dissolved representing 60% of the starting inventory. The evolution resulted in reducing the sludge solids volume by 22,300 liters (5900 gallons), preparing the tank for chemical cleaning with oxalic acid.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ozone Removal by Filters Containing Activated Carbon: A Pilot Study

This study evaluated the ozone removal performance of moderate-cost particle filters containing activated carbon when installed in a commercial building heating, ventilating, and air conditioning (HVAC) system. Filters containing 300 g of activated carbon per 0.09 m2 of filter face area were installed in two 'experimental' filter banks within an office building located in Sacramento, CA. The ozone removal performance of the filters was assessed through periodic measurements of ozone concentrations in the air upstream and downstream of the filters. Ozone concentrations were also measured upstream and downstream of a 'reference' filter bank containing filters without any activated carbon. The filter banks with prefilters containing activated carbon were removing 60percent to 70percent of the ozone 67 and 81 days after filter installation. In contrast, there was negligible ozone removal by the reference filter bank without activated carbon.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗