Informing solar blind radioluminescence imaging through a calibrated spectrum

While direct radiation detection methods offer great insight into the origin of ionizing particles and photons, their use to locate contaminated areas or concealed radioactive sources can lead to undue exposure of personnel and equipment to ionizing radiation or the potential for contamination. These same sources induce ultraviolet (UV) optical photon fluorescence in air – a process referred to as radioluminescence – that may be imaged from low dose regions over larger attenuation lengths than ionizing radiation. However, most optical detection methods are limited to low lighting conditions to image the more abundant ultraviolet-A (UV-A) photons. To extend this capability to room light or daytime conditions, the solar blind region (Ultraviolet-C (UV-C), <280 nm) can be tapped. Though the emission yield of UV-C photons is roughly two orders of magnitude lower than that in the UV-A regime, the UV-C offers dramatic improvements in signal-to-noise ratios under bright lighting conditions due to decreased background interferences. The yield of specific UV-C lines, if present in the literature at all, varies widely, which has a large impact in modeling and analyzing standoff UV-C measurement scenarios. Thus, we have captured improved radioluminescence spectra over 250–400 nm and identified observed emission peaks in ambient air. Many of the UV-C photons produced by ionizing radiation excitation result from high-energy, molecular nitrogen Gaydon-Herman transitions which have had limited study to date for this application. Relating these findings to published UV-A yields, we estimate emissions between 0.15–0.19 photons/MeV over 250–280 nm. Additionally, we also use a commercial corona-discharge imaging camera to demonstrate outdoor UV-C radiation mapping of alpha and gamma emitters from 50 and 75 m standoffs, respectively. The imaged “counts” are compared to optically modelled values and show the same trend over distance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radioisotope replacement with compact electron linear accelerators

The replacement of radioactive sources with alternative technologies has been identified as a priority by international authorities, due to the risk of accidents and diversion by terrorists for use in Radiological Dispersal Devices. Many of these sources can be replaced with the X-rays produced by electron beams accelerated to MeV energies. However, the size, weight and costs of electron linacs must be significantly reduced to be considered for radioisotope replacement. RadiaBeam Technologies, LLC is developing a series of inexpensive compact electron accelerators in the 1–10 MeV range for radioisotope replacement such as Ir-192, Cs-137 and Co-60 for various applications. The dramatic level of miniaturization and cost-reduction was achieved thanks to the implementation of such innovative technologies as high-frequency magnetrons, split accelerating structure fabrication technology and solid-state Marx modulators. Here, in this paper, we overview RadiaBeam's compact linac developments, discuss the enabling technologies, and report on the current progress.

43 PARTICLE ACCELERATORS↗

Quantum-dot doped polymeric scintillation material for radiation detection

In this study, scintillation and luminescence enhancement were observed in a Quantum Dot-doped scintillating polymer, facilitating energy transfer with polymer medium and scintillating dye. 2,5-diphenyloxazole (PPO) and Cadmium Sulfide (CdS) Quantum Dots (QD) with 418 nm emission coated with oleic acid were dispersed in a polyvinyl toluene (PVT) matrix with transparency retained. Under UV excitation a sharp emission was detected at 426 nm from minimal QD loading with possible indication of QD energy transfer. Scintillation enhancement was observed with different radioactive sources in PVT-PPO/QD polymer with a photomultiplier detector setup. The response to gamma and beta radiation was investigated with differences in the energy spectrum and a count increase observed with increased QD loading.

36 MATERIALS SCIENCE↗

Experimental Approach to Controllably Vary Protein Oxidation While Minimizing Electrode Adsorption for Boron-Doped Diamond Electrochemical Surface Mapping Applications

Oxidative protein surface mapping has become a powerful approach for measuring the solvent accessibility of folded protein structures. A variety of techniques exist for generating the key reagent hydroxyl radicals for these measurements; however, many of these approaches require use of radioactive sources or caustic oxidizing chemicals. The purpose of this research was to evaluate and optimize the use of boron-doped diamond (BDD) electrochemistry as a highly accessible tool for producing hydroxyl radicals as a means to induce a controllable level of oxidation on a range of intact proteins. These experiments utilize a relatively high flow rates to reduce protein residence time inside the electrochemical flow chamber, along with a unique cell activation approach to improve control over the intact protein oxidation yield. Studies were conducted to evaluate the level of protein adsorption onto the electrode surface. This report demonstrates a robust protocol for the use of BDD electrochemistry and high performance LC-MS/MS as a high-throughput experimental pipeline for probing higher order protein structure, and illustrates how it is complementary to predictive computational modeling efforts.

boron-doped diamond electrochemistry↗

Tetris-inspired detector with neural network for radiation mapping

Abstract Radiation mapping has attracted widespread research attention and increased public concerns on environmental monitoring. Regarding materials and their configurations, radiation detectors have been developed to identify the position and strength of the radioactive sources. However, due to the complex mechanisms of radiation-matter interaction and data limitation, high-performance and low-cost radiation mapping is still challenging. Here, we present a radiation mapping framework using Tetris-inspired detector pixels. Applying inter-pixel padding for enhancing contrast between pixels and neural networks trained with Monte Carlo (MC) simulation data, a detector with as few as four pixels can achieve high-resolution directional prediction. A moving detector with Maximum a Posteriori (MAP) further achieved radiation position localization. Field testing with a simple detector has verified the capability of the MAP method for source localization. Our framework offers an avenue for high-quality radiation mapping with simple detector configurations and is anticipated to be deployed for real-world radiation detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sterile-neutrino search based on 259 days of KATRIN data

Neutrinos are the most abundant fundamental matter particles in the Universe and play a crucial part in particle physics and cosmology. Neutrino oscillation, discovered about 25 years ago, shows that the three known species mix with each other. Anomalous results from reactor and radioactive-source experiments suggest a possible fourth neutrino state, the sterile neutrino, which does not interact through the weak force. The Karlsruhe Tritium Neutrino (KATRIN) experiment, primarily designed to measure the neutrino mass using tritium β-decay, also searches for sterile neutrinos suggested by these anomalies. A sterile-neutrino signal would appear as a distortion in the β-decay energy spectrum, characterized by a discontinuity in curvature (kink) related to the sterile-neutrino mass. This signature, which depends only on the shape of the spectrum rather than its absolute normalization, offers a robust, complementary approach to reactor experiments. Here we report the analysis of the energy spectrum of 36 million tritium β-decay electrons recorded in 259 measurement days within the last 40 eV below the endpoint. The results exclude a substantial part of the parameter space suggested by the gallium anomaly and challenge the Neutrino-4 claim. Together with other neutrino-disappearance experiments, KATRIN probes sterile-to-active mass splittings from a fraction of an eV 2 to several hundred eV 2 , excluding light sterile neutrinos with mixing angles above a few per cent.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of the sensitivity and fading characteristics of an image plate system for x-ray diagnostics

Image plates (IPs) are a reusable recording media capable of detecting ionizing radiation, used to diagnose x-ray emission from laser-plasma experiments. Due to their superior performance characteristics in x-ray applications [C. C. Bradford, W. W. Peppler, and J. T. Dobbins III, Med. Phys. 26, 27 (1999) and J. Digit. Imaging. 12, 54 (1999)], the Fuji Biological Analysis System (BAS) IPs are fielded on x-ray diagnostics for the HELEN laser by the Plasma Physics Department at AWE. The sensitivities of the Fuji BAS IPs have been absolutely calibrated for absolute measurements of x-ray intensity in the energy range of 0-100 keV. In addition, the Fuji BAS IP fading as a function of time was investigated. We report on the characterization of three Fuji BAS IP responses to x-rays using a radioactive source, and discrete x-ray line energies generated by the Excalibur soft x-ray facility and the Defense Radiological Standards Centre filter-fluorescer hard x-ray system at AWE.

07 ISOTOPE AND RADIATION SOURCES↗

Positron-Electron Pair Creation Near Threshold

Positron-electron pair creation near the threshold energy is extremely difficult to investigate by both experiments and theory. First test experiments were performed at the ILL to determine the cross sections for positron-electron pair creation near threshold using prompt {gamma}-rays from different targets after neutron capture and conventional radioactive sources. Pair creation was studied in a Ge detector, which simultaneously acted as sample and detector. First results are presented which show a significant deviation from theoretical values near threshold.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photon Interaction Parameters for Some Borate Glasses

Some photon interaction parameters of dosimetric interest such as mass attenuation coefficients, effective atomic number, electron density and KERMA relative to air have been computed in the wide energy range from 1 keV to 100 GeV for some borate glasses viz. barium-lead borate, bismuth-borate, calcium-strontium borate, lead borate and zinc-borate glass. It has been observed that lead borate glass and barium-lead borate glass have maximum values of mass attenuation coefficient, effective atomic number and KERMA relative to air. Hence, these borate glasses are suitable as gamma ray shielding material, packing of radioactive sources etc.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement Of Gas Electron Multiplier (GEM) Detector Characteristics

The High Energy Physics group of the University of Texas at Arlington has been developing gas electron multiplier detectors to use them as sensitive gap detectors in digital hadron calorimeters for the International Linear Collider, a future high energy particle accelerator. For this purpose, we constructed numerous GEM detectors that employ double GEM layers. In this study, two kinds of prototype GEM detectors were tested; one with 28x28 cm{sup 2} active area double GEM structure with a 3 mm drift gap, a 1 mm transfer gap and a 1 mm induction gap and the other with two 3x3 cm{sup 2} GEM foils in the amplifier stage with a 5 mm drift gap, a 2 mm transfer gap and a 1 mm induction gap. The detectors' characteristics from exposure to high-energy charged particles and other radiations were measured using cosmic rays and {sup 55}Fe radioactive source. From the {sup 55}Fe tests, we observed two well separated characteristic X-ray emission peaks and confirmed the detectors' functionality. We also measured chamber gains to be over 6000 at a high voltage of 395 V across each GEM electrode. The responses to cosmic rays show the spectra that fit well to Landau distributions as expected from minimum ionizing particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Production And Characterization Of Tungsten-Based Positron Moderators

Experiments of interest in Atomic Physics require production of well-defined low-energy positron beams through a moderation process of high-energy positrons, which can be produced by either the use of a radioactive source or by accelerator based pair production process. Tungsten is one of the most commonly used moderator materials because of its reasonable efficiency, high work function and relatively low cost. In this work we present different methods to produce tungsten-based candidate moderators in a variety of shapes. We also present results from characterizing these candidate moderators by ion beam analysis and microscopy techniques.

43 PARTICLE ACCELERATORS↗

Dose received by occupationally exposed workers at a nuclear medicine department

Personal Dose Equivalent (PDE) values were determined for occupational exposed workers (OEW) at the Nuclear Medicine Department (NMD) of 'Instituto Nacional de Cancerologia' (INCan), Mexico, using TLD-100 thermoluminescent dosemeters. OEW at NMD, INCan make use of radiopharmaceuticals for diagnosis and treatment of diseases. Radionuclides associated to a pharmaceutical compound used at this Department are {sup 131}I, {sup 18}F, {sup 68}Ga, {sup 99m}Tc, {sup 111}In and {sup 11}C with main gamma emission energies between 140 and 511 keV. Dosemeter calibration was performed at the metrology department of 'Instituto Nacional de Investigaciones Nucleares' (ININ), Mexico. Every occupational worker used dark containers with three dosimeters which were replaced monthly for a total of 5 periods. Additionally, control dosemeters were also placed at a site free of radioactive sources in order to determine the background radiation. Results were adjusted to find PDE/day and estimating annual PDE values in the range between 2 mSv (background) and 9 mSv. The mean annual value is 3.51 mSv and the standard deviation SD is 0.78 mSv. Four of the 16 OEW received annual doses higher than the average +1 SD (4.29 mSv). Results depend on OEW daily activities and were consistent for each OEW for the 5 studied periods as well as with PDE values reported by the firm that performs the monthly service. All obtained values are well within the established annual OEW dose limit stated in the {sup R}eglamento General de Seguridad Radiologica{sup ,} Mexico (50 mSv), as well as within the lower limit recommended by the 'International Commission on Radiation Protection' (ICRP), report no.60 (20 mSv). These results verify the adequate compliance of the NMD at INCan, Mexico with the norms given by the national regulatory commission.

61 RADIATION PROTECTION AND DOSIMETRY↗

The half-life of {sup 131g,m}Te

In this work, the half-lives of {sup 131m}Te and {sup 131g}Te were measured. Radioactive sources of {sup 131}Te were obtained using the {sup 130}Te(n,{gamma}){sup 131}Te nuclear reaction. These nuclear parameters have been determined with a better confidence and accuracy than previously available: 18.89 {+-} 0.11 min and 33.18 {+-} 0.13 h, respectively. These results are quite helpful for new calculations that attempt to describe the low-lying levels in {sup 131}I from the decay of {sup 131g,m}Te.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The “accumulation effect” of positrons in the stack of foils, detected by measurements of the positron implantation profile

The profiles of positrons implanted from the radioactive source {sup 22}Na into a stack of foils and plates are the subject of our experimental and theoretical studies. The measurements were performed using the depth scanning of positron implantation profile method, and the theoretical calculations using the phenomenological multi-scattering model (MSM). Several stacks consisting of silver, gold and aluminum foils, and titanium and germanium plates were investigated. We notice that the MSM describes well the experimental profiles; however when the stack consisting of silver and gold foils, the backscattering and linear absorption coefficients differ significantly from those reported in the literature. We suggest the energy dependency of the backscattering coefficient for silver and gold. In the stacks which comprise titanium and germanium plates, there were observed the features, which indicate the presence of the “accumulation effect” in the experimental implantation profile. This effect was previously detected in implantation profiles in Monte Carlo simulations using the GEANT4 tool kit, and it consists in higher localization of positrons close the interface. We suppose that this effect can be essential for positron annihilation in any heterogeneous materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental investigation of silicon photomultipliers as compact light readout systems for gamma-ray spectroscopy applications in fusion plasmas

A matrix of Silicon Photo Multipliers has been developed for light readout from a large area 1 in. × 1 in. LaBr{sub 3} crystal. The system has been characterized in the laboratory and its performance compared to that of a conventional photo multiplier tube. A pulse duration of 100 ns was achieved, which opens up to spectroscopy applications at high counting rates. The energy resolution measured using radioactive sources extrapolates to 3%–4% in the energy range E{sub γ} = 3–5 MeV, enabling gamma-ray spectroscopy measurements at good energy resolution. The results reported here are of relevance in view of the development of compact gamma-ray detectors with spectroscopy capabilities, such as an enhanced gamma-ray camera for high power fusion plasmas, where the use of photomultiplier is impeded by space limitation and sensitivity to magnetic fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Half-life determination for {sup 108}Ag and {sup 110}Ag

In this work, the half-life of the short-lived silver radionuclides {sup 108}Ag and {sup 110}Ag were measured by following the activity of samples after they were irradiated in the IEA-R1 reactor. The results were then fitted using a non-paralizable dead time correction to the regular exponential decay and the individual half-life values obtained were then analyzed using both the Normalized Residuals and the Rajeval techniques, in order to reach the most exact and precise final values. To check the validity of dead-time correction, a second correction method was also employed by means of counting a long-lived {sup 60}Co radioactive source together with the samples as a livetime chronometer. The final half-live values obtained using both dead-time correction methods were in good agreement, showing that the correction was properly assessed. The results obtained are partially compatible with the literature values, but with a lower uncertainty, and allow a discussion on the last ENSDF compilations' values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Future short baseline neutrino searches with nuclear decays

Several anomalies coming from neutrino experiments may be pointing towards new physics: these hints suggest the existence of one (or more) sterile neutrinos. We discuss some of the experiments proposed to verify (or disproof) this hypothesis by using an intense radioactive source in proximity of large neutrino detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Silicon detectors for monitoring neutron beams in n-TOF beamlines

During 2014, the second experimental area (EAR2) was completed at the n-TOF neutron beam facility at CERN (n-TOF indicates neutron beam measurements by means of time of flight technique). The neutrons are produced via spallation, by means of a high-intensity 20 GeV pulsed proton beam impinging on a thick target. The resulting neutron beam covers the energy range from thermal to several GeV. In this paper, we describe two beam diagnostic devices, both exploiting silicon detectors coupled with neutron converter foils containing {sup 6}Li. The first one is based on four silicon pads and allows monitoring of the neutron beam flux as a function of the neutron energy. The second one, in beam and based on position sensitive silicon detectors, is intended for the reconstruction of the beam profile, again as a function of the neutron energy. Several electronic setups have been explored in order to overcome the issues related to the gamma flash, namely, a huge pulse present at the start of each neutron bunch which may blind the detectors for some time. The two devices were characterized with radioactive sources and also tested at the n-TOF facility at CERN. The wide energy and intensity range they proved capable of sustaining made them attractive and suitable to be used in both EAR1 and EAR2 n-TOF experimental areas, where they became immediately operational.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗