Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RACKS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Photonic integration for UV to IR applications

Photonic integration opens the potential to reduce size, power, and cost of applications normally relegated to table- and rack-sized systems. Today, a wide range of precision, high-end, ultra-sensitive, communication and computation, and measurement and scientific applications, including atomic clocks, quantum communications, processing, and high resolution spectroscopy, are ready to make the leap from the lab to the chip. However, many of these applications operate at wavelengths not accessible to the silicon on insulator-based silicon photonics integration platform due to absorption, power handling, unwanted nonlinearities, and other factors. Next generation photonic integration will require ultra-wideband photonic circuit platforms that scale from the ultraviolet to the infrared and that offer a rich set of linear and nonlinear circuit functions as well as low loss and high power handling capabilities. This article provides an assessment of the field in ultra-wideband photonic waveguides to bring power efficient, ultra-high performance systems to the chip-scale and enable compact transformative precision measurement, signal processing, computation, and communication techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compact single-shot electro-optic detection system for THz pulses with femtosecond time resolution at MHz repetition rates

Electro-optical detection has proven to be a valuable technique to study temporal profiles of THz pulses with pulse durations down to femtoseconds. As the Coulomb field around a relativistic electron bunch resembles the current profile, electro-optical detection can be exploited for non-invasive bunch length measurements at accelerators. We have developed a very compact and robust electro-optical detection system based on spectral decoding for single-shot longitudinal bunch profile monitoring at the European X-ray Free Electron Laser (XFEL) for electron bunch lengths down to 200 fs (rms). Apart from the GaP crystal and the corresponding laser optics at the electron beamline, all components are housed in 19 in. chassis for rack mount and remote operation inside the accelerator tunnel. An advanced laser synchronization scheme based on radio-frequency down-conversion has been developed for locking a custom-made Yb-fiber laser to the radio-frequency of the European XFEL accelerator. In order to cope with the high bunch repetition rate of the superconducting accelerator, a novel linear array detector has been employed for spectral measurements of the Yb-fiber laser pulses at frame rates of up to 2.26 MHz. In this paper, we describe all sub-systems of the electro-optical detection system as well as the measurement procedure in detail and discuss the first measurement results of longitudinal bunch profiles of around 400 fs (rms) with an arrival-time jitter of 35 fs (rms).

47 OTHER INSTRUMENTATION↗

Status of the CMS Detector Control System

The Compact Muon Solenoid (CMS) is a CERN multi-purpose experiment that exploits the physics of the Large Hadron Collider (LHC). The Detector Control System (DCS) is responsible for ensuring the safe, correct and efficient operation of the experiment, and has contributed to the recording of high quality physics data. The DCS is programmed to automatically react to the LHC operational mode. CMS sub-detectors bias voltages are set depending on the machine mode and particle beam conditions. An operator provided with a small set of screens supervises the system status summarized from the approximately 6M monitored parameters. Using the experience of nearly two years of operation with beam the DCS automation software has been enhanced to increase the system efficiency by minimizing the time required by sub-detectors to prepare for physics data taking. From the infrastructure point of view the DCS will be subject to extensive modifications in 2012. The current rack mounted control PCs will be replaced by a redundant pair of DELL Blade systems. These blade servers are a high-density modular solution that incorporates servers and networking into a single chassis that provides shared power, cooling and management. This infrastructure modification associated with the migration to blade servers will challenge the DCS software and hardware factorization capabilities. The on-going studies for this migration together with the latest modifications are discussed in the paper.

Bauer, Gerry↗

Dielectric Response of Cross-Linked Polyethylene (XLPE) Cable Insulation Material to Radiation and Thermal Aging

This work seeks dielectric indicators of the aged state of cross-linked polyethylene (XLPE) that has been simultaneously irradiated and thermally aged. The XLPE samples studied here were of the same material formulation as XLPE insulation found in RSCC I46-0021 instrumentation cable, formed into tapes with dimensions approximately 20 × 0.7 × 100 mm 3 . Aging was conducted by suspending the samples from a rack within an oven and subsequently exposing oven and samples to gamma radiation. Samples were aged at 60, 90, and 115 °C, with gamma-radiation dose rates from 0 to 450 Gy/h with total received doses from 0 to 216 kGy. The dielectric spectra of these samples were measured over the frequency range 1 Hz to 1 MHz using custom electrodes and a Novocontrol dielectric spectrometer before dielectric breakdown strength was measured on the same samples. Dielectric loss tangent was observed to increase as a function of dose, dose rate and exposure time for XLPE samples exposed as described above. Dielectric loss tangent did not, however, show sensitivity to thermal aging for the range of temperatures studied. Dielectric breakdown strength initially increased as the material oxidized, then decreased for more extreme aging, due to chain scission. It is concluded that dielectric loss tangent is a promising indicator of XLPE aging due to gamma radiation exposure.

dielectric losses, dielectric breakdown, cable ins↗

An Accurate Fast Fluid Dynamics Model for Data Center Applications

Traditional CFD is broadly useful in the design and operation of reliable and efficient data centers. It is nevertheless computationally expensive, particularly when employed for design optimization, which usually requires multiple simulations. To speed-up calculations while retaining essential airflow physics, several researchers have turned to an alternative CFD methodology, namely, fast fluid dynamics (FFD). FFD has been reported to be much faster than traditional CFD, but at an assumed (acceptable) trade-off of reduced accuracy. However, a recent comparison of FFD and traditional CFD for data center plenum applications produced nearly indistinguishable results and suggested that previously-reported FFD/traditional-CFD differences were due primarily to inconsistent: 1) advection schemes, 2) computational grids, and 3) turbulence models. The present paper extends this FFD/traditional-CFD comparison to the data center whitespace and confirms the finding that a true like-for-like comparison produces nearly identical predictions. Our FFD implementation utilizes a first-order upwind finite-volume scheme for advection like traditional CFD, so alternative advection schemes (e.g., semi-Lagrangian) are not considered further here. Likewise, the effect of grid choice on traditional-CFD predictions is well known. However, the effect of turbulence model for data center applications has not been reported extensively so we do consider this topic further here. We compare the standard k-e and a simpler algebraic model to benchmark experimental data from a real data center. We find that the algebraic turbulence model predicts rack-inlet temperatures at a similar level-of-accuracy as the k-e model for our fairly-simple-airflow reference data center.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of Photovoltaic Module Materials and Design on Module Deformation Under Load

Static structural finite element models of an aluminum-framed crystalline silicon (c-Si) photovoltaic (PV) module and a glass-glass thin film PV module were constructed and validated against experimental measurements of deflection under uniform pressure loading. Parametric analyses using Latin Hypercube Sampling (LHS) were performed to propagate simulation input uncertainties related to module material properties, dimensions, and manufacturing tolerances into expected uncertainties in simulated deflection predictions. This exercise verifies the applicability and validity of finite element modeling for predicting mechanical behavior of solar modules across architectures and enables computational models to be used with greater confidence in assessment of module mechanical stressors and design for reliability. Sensitivity analyses were also performed on the uncertainty quantification data sets using linear correlation coefficients to elucidate the key parameters influencing module deformation. This information has implications on which materials or parameters may be optimized to best increase module stiffness and reliability, whether the key optimization parameters change with module architecture or loading magnitudes, and whether parameters such as frame design and racking must be replicated in reduced-scale reliability studies to adequately capture full module mechanical behavior.

14 SOLAR ENERGY↗

A Compact, Flexible, High Channel Count DAQ Built From Off-the-Shelf Components

Medium to large channel count detectors are usually faced with a few unattractive options for data acquisition (DAQ). Small to medium sized TPC experiments, for example, can be too small to justify the high expense and long development time of application specific integrated circuit (ASIC) development. In some cases an experiment can piggy-back on a larger experiment and the associated ASIC development, but this puts the time line of development out of the hands of the smaller experiment. Another option is to run perhaps thousands of cables to rack mounted equipment, which is clearly undesirable. The development of commercial high-speed high-density FPGAs and ADCs combined with the small discrete components and robotic assembly open a new option that scales to tens of thousands of channels and is only slightly larger than ASICs using off-the-shelf components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring Properties and Correlations of Fatal Events in a Large-Scale HPC System

In this study, we explore potential correlations of fatal system events for one of the most powerful supercomputers-IBM Blue Gene/Q Mira, which is deployed at Argonne National Laboratory, based on its 5-year reliability, availability, and serviceability (RAS) log. Our contribution is two-fold. (1) We design an efficient log analysis tool, namely LogAider, with a novel filtering method to effectively extract fatal events from masses of system messages that are heavily duplicated in the log. LogAider exhibits a very precise detection of temporal-correlation with a high similarity (up to 95 percent) to the ground-truth (i.e., compared to the failure records reported by the administrators). The total number of fatal events can be reduced to about 1,255 compared with originally 2.6 million duplicated fatal messages. (2) We analyze the 5-year RAS log of the MIRA system using LogAider, and summarize six important "takeaways" which can help system vendors and administrators better understand an extreme-scale system's fatal events. Specifically, we find that the distribution or proportion of the fatal system events follow a Pareto-like principle in general. The temporal correlation among fatal events is much stronger than that of warn messages and info messages, and the correlated events tend to constitute a few clusters. The mean time between fatal events (MTBFE) of the Mira system is about 1.3 days from the perspective of the system, and the MTTI is 2-4 days from the perspective of users. The most error-prone item value with respect to any key attribute appears likely in the log every 2-10 days. Weibull, Gamma, and Pearson6 are the three best-fit distributions for the fatal event intervals. The overall correlation of fatal events on the 5D torus network is not prominent, whereas the small-region locality correlation (e.g., the fatal events inside racks) is relatively strong. We believe our work will be interesting to large-scale HPC system administrators and vendors and to fault tolerance researchers, enabling them to better understand fatal events and mitigate such events accordingly.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-501: Initial Orthovoltage Beam Profile Analysis of a Small Brass MLC

Purpose To create brass leaves for an orthovoltage MLC and take initial beam profile measurements. Methods The low-energy MLC was designed in previous work. Brass was chosen for its self-lubrication and low cost. Stock brass rectangles (30cm × 1.0cm × 0.5cm) were ordered with pre-cut gear rack along the topmost long edges. Leaf designs were translated into G-code, then cut with a Tormach CNC-1100 mill. Intense bowing was observed in the beam direction, which required straightening via an in-house jig. Straightened leaves were placed into MLC assembly and mounted to a 320 kVp orthovoltage tube. EDR2 film was irradiated in four situations: MLC open so one edge was isocentric, and MLC open more than isocentric, completely closed MLC, and an open field shot with the MLC removed. The first two scans tested penumbra for our rectangular edges due to unfocused design. The final two scans tested transmission and interleaf leakage. All four experiments were set to 120 kVp and 10 mA for two minutes. Results Transmission and interleaf leakage were found to be zero. Interleaf leakage is faintly visible on film, but undetected by our film scanner despite high spatial resolution. Penumbra at isocenter was found to be 0.72mm, which matched the penumbras of true field edges. Penumbra off-isocenter was 1.1mm. Mechanically, leaves are moving smoothly once straightened. Conclusion Beam profiles through our brass MLC are acceptable. Leaves attenuate and move as designed. Looking forward, we intend to animate our MLC to deliver more complicated treatment plans.

60 APPLIED LIFE SCIENCES↗

An evaluation of the CORAL interconnects

The US Department of Energy deployed the Summit and Sierra supercomputers with the latest state-of-the-art network interconnect technology in 2018 and both systems entered production in 2019. In this paper, we provide an in-depth assessment of the systems' network interconnects that are based on Enhanced Data Rate (EDR) 100 Gb/s Mellanox InfiniBand. Both systems use second-generation EDR Host Channel Adapters (HCAs) and switches with several new features such as Adaptive Routing (AR), switch-based collectives, and HCA-based tag matching. Although based on the same components, Summit's network is "non-blocking" (i.e., a fully provisioned Clos network) and Sierra's network has a 2:1 taper between the racks and aggregation switches. We evaluate the two systems' interconnects using traditional communication benchmarks as well as production applications. We find that the new Adaptive Routing dramatically improves performance but the other new features still need improvement.

Zimmer, Christopher↗

Thermal Management for FPGA Nodes in HPC Systems

The integration of FPGAs into large-scale computing systems is gaining attention. In these systems, real-time data handling for networking, tasks for scientific computing, and machine learning can be executed with customized datapaths on reconfigurable fabric within heterogeneous compute nodes. At the same time, thermal management, particularly battling the cooling cost and guaranteeing the reliability, is a continuing concern. The introduction of new heterogeneous components into HPC nodes only adds further complexities to thermal modeling and management. The thermal behavior of multi-FPGA systems deployed within large compute clusters is less explored. Here, we first show that the thermal behaviors of different FPGAs of the same generation can vary due to their physical locations in a rack and process variation, even though they are running the same tasks. We present a machine learning–based model to capture the thermal behavior of each individual FPGA in the cluster. We then propose two thermal management strategies guided by our thermal model. First, we mitigate thermal variation and hotspots across the cluster by proactive thermal-aware task placement. Under the tested system and benchmarks, we achieve up to 26.4° C and on average 13.3° C system temperature reduction with no performance penalty. Second, we utilize this thermal model to guide HLS parameter tuning at the task design stage to achieve improved thermal response after deployment.

97 MATHEMATICS AND COMPUTING↗

Berkeley eXtensible Environment (BXE) v3

The Berkeley eXtensible Environment (BXE) provides a cloud environment for hardware designers and computer architects to design, build, and simulate their custom architectures on an on-premises FPGA cluster. Utilizing the Chipyard, MoSAIC, and FireSim frameworks, users are provided an environment where they can assemble SoC designs from an existing library of components or import their own source code. Once their designs are ready, they can utilize the FireSim framework provided by BXE to deploy and simulate their designs on the FPGA. Users aren't limited to a single FPGA; they can deploy multiple instances across multiple FPGAs, acting like a rack of servers, or partition their large design across multiple FPGAs, ganging multiple FPGAs into a single simulated system.

Fatollahi-Fard, Farzin↗

Summer Aerosol and Trace Gas Observations in Houston, Texas Using an Adaptable Mobile Facility

An aerosol container featuring a shared inlet system was deployed to Houston, Texas in July 2022, enabling direct, high-time-resolution in situ measurements of aerosols and trace gases. The internal rack system and floorplan was designed for adaptable modularity to elucidate aerosol physicochemical processes at fine scales. The design allowed for the deployment of a core instrument suite and additional customized research grade instruments. A heterogeneous mixture of aerosols was observed during three regimes: (1) intermittent black carbon (BC) and diurnal variations in aerosol chemical composition, (2) observed particle growth associated with SO 2 , (3) transported supermicron dust. The high variability of observed particles and gases in high time resolution indicated a complex urban area with multiple local and regional sources and processes. Particle growth rates of 7–16 nm/hr were observed for submicron particles during periods when SO 2 was >0.5 ppbv. Two periods of multi-day long-range transport events of dust from the African Sahara were observed in the supermicron and submicron particle modes with total mass concentrations up to 30 μg m −3 . Aerosol scattering angstrom exponents and extinction coefficients (B ext ) increased with humidity as a function of particle composition. The measurements demonstrate collaborative capabilities that can be used to increase observations of aerosol processing, microphysical and optical properties, internal mixing state, and supermicron aerosol that are not parameterized or missing in global Earth energy system models.

54 ENVIRONMENTAL SCIENCES↗

Collection of Disk Failure Events from Alpine, the Parallel File System for Summit Supercomputer

This dataset contains disk (HDD) failure events collected from the Alpine storage system of the Summit supercomputer, hosted at OLCF, spanning from January 4, 2019, to December 21, 2023 (a total of 4 years, 11 months, and 18 days), covering 89% of its operational lifetime. It includes 3,766 disk failure events, each recorded with its detection timestamp (in ISO 8601 format) and detailed by its location within the storage system - rack, enclosure, and drive slot number.

97 MATHEMATICS AND COMPUTING↗

Disk Failure Dataset from the Campaign Storage System

This dataset consists of 1,389 disk (HDD) failure events collected from the Campaign storage system at LANL. The Campaign system supported various compute platforms throughout its lifespan, including Cielo, Fire, Ice, and notably, the Trinity supercomputer. Each recorded event includes its detection timestamp (in ISO 8601 format) and details such as its location within the storage system—rack, enclosure, and drive slot number. The data, spanning from May 4, 2021, to July 25, 2023 (2 years, 2 months, and 22 days), represents failure events from the terminal years of Campaign's operational period, accounting for 26% of its total operational time.

97 MATHEMATICS AND COMPUTING↗

Approach for validating actinide and fission product compositions for burnup credit criticality safety analyses

This paper describes a depletion code validation approach for criticality safety analysis using burnup credit for actinide and fission product nuclides in spent nuclear fuel (SNF) compositions. The technical basis for determining the uncertainties in the calculated nuclide concentrations is comparison of calculations to available measurements obtained from destructive radiochemical assay of SNF samples. Probability distributions developed for the uncertainties in the calculated nuclide concentrations were applied to the SNF compositions of a criticality safety analysis model by the use of a Monte Carlo uncertainty sampling method to determine bias and bias uncertainty in effective neutron multiplication factor. Application of the Monte Carlo uncertainty sampling approach is demonstrated for representative criticality safety analysis models of pressurized water reactor spent fuel pool storage racks and transportation packages using burnup-dependent nuclide concentrations calculated with SCALE 6.1 and the ENDF/B-VII nuclear data. Furthermore, the validation approach and results support a recent revision of the U.S. Nuclear Regulatory Commission Interim Staff Guidance 8.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-performance and high-fidelity Monte Carlo solutions to the BEAVRS benchmark

The BEAVRS (Benchmark for Evaluation and Validation of Reactor Simulation) benchmark is solved by PRAGMA, the GPU-based continuous energy Monte Carlo code. The resulting solutions are comprised of the detailed simulation results of two cycles, each of which consists of the zero power physics test (ZPPT) and the core depletion calculations. The ZPPT consists of characteristic parameters, such as critical boron concentration (CBC), control rod bank worth, isothermal temperature coefficients, and assembly-wise detector signal, which are compared with measured data provided by the benchmark administration. The core depletion calculations were performed for both the hot full power and the load follow modes, and the comparison was made with the measured or deduced CBCs and assembly-wise detector signals. In the load follow calculations, the operating power history was approximately applied to simulate the real operation as closely as possible. PRAGMA performed the various calculations with a tremendous number of histories ranging up to hundreds of millions per cycle, exploiting GPUs' massively parallel performance. The load follow run time was shorter than 16 hours on a single rack of computing nodes mounded with 24 gaming GPUs with a remarkable agreement with the measurements for most comparisons. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

LCLS-II Cryomodule and Cryogenic Distribution Control

The new superconducting Linear Coherent Light Source (LCLS-II) at the SLAC National Accelerator Laboratory will be an upgrade to LCLS, the world’s first hard X-ray free-electron laser. LCLS-II is in an advanced stage of construction with equipment for both Cryoplants as well as more than half of the 37 cryomodules onsite. Jefferson Lab (JLab) is a partner lab responsible for building half of the LCLS-II cryomodules. Hence the Low Energy Recirculation Facility (LERF) at JLab was used to stage and test LCLS-II cryomodules before shipping them to SLAC. LERF was set up to test two cryomodules at a time. LERF used LCLS-II cryogenic controls instrumentation racks, Programmable Logic Controllers (PLC) controls and Experimental Physics and Industrial Control System (EPICS) Input/Output Controllers (IOCs) with the intention to use the LERF setup to check-out and verify cryogenic controls for LCLS-II. The cryogenic controls first utilized at LERF would then be replicated for controlling all 37 cryomodules via an EPICS user interface. This paper discusses the cryogenic controls currently developed for implementation in the LCLS-II project.

43 PARTICLE ACCELERATORS↗