Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “QUARTZ”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Kinetics of carbothermal reduction of quartz under vacuum.

Study of the kinetics of carbothermal reduction of quartz in a batch reactor between 0.25 torr and 1 microtorr. The effects of temperature, CO partial pressure, SiO2 phase transformation, and alkali and alkaline-earth oxide additives on the rate of reaction are reported. The results are consistent with a model based on a transitory phase intermediate.

Khalafalla, S. E.↗

Quartz and feldspar glasses produced by natural and experimental shock.

Refractive index, density, and infrared absorption studies of naturally and experimentally shocked-produced glasses formed from quartz, plagioclase, and alkali-feldspar confirm the existence of two main groups of amorphous forms of the framework silicates: solid-state and liquid-state glasses. These were apparently formed as metastable release products of high-pressure-phases above and below the glass transition temperatures. Solid-state glasses exhibit a series of structural states with increasing disorder caused by increasing shock pressures and temperatures. They gradually merge into the structural state of fused minerals similar to that of synthetic glasses quenched from a melt. Shock-fused alkali feldspars can, however, be distinguished from their laboratory-fused counterparts by infrared absorption and by higher density.

Stoeffler, D.↗

X-ray reflection efficiency of nickel-coated quartz optical flats

The reflection efficiency of quartz optical flats vacuum coated with 1000-A nickel was evaluated. Of the three vacuum coated samples tested, two had been contaminated during the firing of the Lunar Module Reaction Control System in the vacuum chamber. Measurements were made for 1.54-, 1.79-, and 2.29-A incident radiation. The reflection efficiency of the contaminated samples was reduced by as much as 50 percent for some angles of incidence.

Reynolds, J. M.↗

Quartz crystal microbalance contamination monitors on Skylab: A quick look analysis

Six quartz crystal microbalance contamination monitors were flown on Skylab to monitor the deposition of material from spacecraft outgassing and from the rendezvous and docking maneuvers of the Command/Service Module. This report contains a quick-look analysis of the data from these units during the unmanned and manned portions of SL2.

Naumann, R.↗

Flight evaluation of a quartz-fiberfrax heat shield.

The results of temperature and base heat flux measurements made on two heat-shield evaluation flights of six-solid-motor Delta boosters are reviewed. Curtains made of quartz cloth and Fiberfrax felt sandwiches formed the heat shield. A comparison is presented of the flight data to ground test results and to an analytical thermal model of the curtain material. In general, the results obtained have confirmed the excellent suitability of the proposed material as a heat shield for the application considered.

Greenwald, G. F.↗

Thermoelectrically-cooled quartz microbalance

Temperature of microbalance can be maintained at ambient temperature or held at some other desired temperature. Microbalance has tow-stage thermoelectric device that controls temperature of quartz crystal. Heat can be pumped to or from balance by Peltier effect.

Mckeown, D.↗

Data from a synchronous altitude satellite quartz crystal microbalance monitor

Results of one year's operation in orbit of the Quartz Crystal Microbalance Monitor on the ATS-6 satellite are presented. The data indicate a general decreasing trend for the first four and one-half months in orbit. At that time, a sudden increase in beat frequency occurred; this correlates in time with the firing of the North Cesium Ion Engine. A general increase in beat frequency is evidenced since that time. Laboratory tests conducted to investigate the phenomenon are described.

Rogers, J. F.↗

Cryogenic Quartz Crystal Microbalance

A radiatively cooled Cryogenic Quartz Crystal Microbalance designed to monitor highly volatile contaminants on the shuttle is described. Measurements are made with two 15-MHz microbalances having removable, optically polished sensors mounted in a radiant cooler. One sensor operates below the freezing point of water and monitors contamination including that of water vapor. The second sensor is heated and monitors the contamination background. It provides a reference from which the density of the water vapor cloud enveloping the shuttle is determined. The design incorporates a low-power dissipation oscillator, heaters for ice removal, and a method for attaching second-surface mirrors to the radiator employing an indium type solder instead of a room temperature vulcanizer.

D Mckeown↗

Feasibility demonstration for hydrogen chloride detection using a chemisorption technique and a quartz crystal microbalance

A method of measuring concentrations of hydrogen chloride between 1 part per billion and 10 parts per million at standard temperature and pressure is presented. The feasibility of a low-cost device incorporating a chemisorption technique coupled with a quartz crystal microbalance was demonstrated in the field at the Viking B launch using a Titan-Centaur vehicle from Kennedy Space Center on August 20, 1975. Hydrogen chloride is a product of solid rocket combustion. The concentration level of hydrogen chloride for this particular launch was measured as approximately 0.2 parts per million at 4 km from the launch site.

Jex, D. W.↗

Inherent time delay for dielectric breakdown in shock-loaded x-cut quartz

Dielectric breakdown in shock-loaded x-cut quartz is examined under conditions of both impact loading and Q-switched laser-irradiation loading. It is observed that breakdown is characterized by an inherent time delay which depends on the magnitude of the electric field. For pulse duration less than about 30 ns, dielectric breakdown is not observed.

Graham, R. A.↗

ATS-6 - Quartz-Crystal Microbalance

The Quartz-Crystal Microbalance Experiment provided data on the possible return of contaminants to the exterior surfaces of the spacecraft. The experiment measures the change in resonant frequency of the crystal due to deposition of material on the surface. There has been no mass accretion corresponding to the firing of hydrazine thrusters to unload the spacecraft momentum wheels. There have been accretions corresponding to the firing of the cesium ion engines.

Rogers, J. F.↗

Correlation between stimulated scattering processes and laser-induced damage in crystalline quartz

The results of a systematic series of experiments to uncover possible correlation between laser-induced stimulated-Brillouin-scattering (SBS) phonons and damage in quartz are presented. Such correlation is confirmed and the various thresholds are established. The anomalous transmission factor under phonon generation is found to decay exponentially as predicted with increasing incident laser power. The LF SBS phonon is also demonstrated to be a sensitive probe for precatastrophic damage.

Yu, C.↗

Experimental hypervelocity impact into quartz sand. II - Effects of gravitational acceleration

Experimental results for craters formed by aluminum spheres impacting at normal incidence against quartz sand targets in gravitational acceleration environments ranging from 0.073 to 1.0 g (g = 980 cm/sq sec) are reported. Impact velocities varied from 0.4 to 8.0 km/sec. Crater dimensions and formation times are compared with results from a simplified dimensional analysis of the cratering processes. Although the comparison indicates a dominant role of gravity relative to the target strength for craters formed in sand, the results serve primarily to emphasize that both gravity and strength are variables of fundamental significance to cratering processes.

Gault, D. E.↗

Effects of accumulated film layers on the accuracy of quartz film thickness monitors

The effect of accumulation layers on the accuracy of quartz thin-film thickness monitors is evaluated. Use of an expanded plane wave ultrasonic propagation theory correctly accounts for observed experimental data. The magnitude of the maximum errors calculated for simply reversing the order of a series of aluminum gold deposits is on the order of 5%. If one totally neglects intervening layers, multiple film propagation and nonlinearity can produce errors greater than 50%.

Heyman, J. S.↗

Experimental study of pyroxene-liquid interaction in quartz-normative basalt 15597

Equilibrium and controlled cooling rate experiments on a synthetic analog of Apollo 15 quartz normative basalt 15597 are reported. While the partitioning of the major elements Ca, Mg, and Fe between pyroxene and liquid is rate independent, the K sub D parameter for Fe/Mg, which is calculated for low-Ca pyroxene, is temperature dependent. It is suggested that chemical trends observed in lunar pyroxenes are a consequence of three rate processes. The processes are (1) rate-dependent suppression of crystallization of other phases until lower temperature alters liquid composition and, therefore, the composition of the pyroxene that crystallizes; (2) the efficiency of fractional crystallization and the extent of crystal zoning are rate dependent; and (3) the partitioning of Al2O3, TiO2, and Cr2O3 between pyroxene and liquid depends on cooling rate.

Grove, T. L.↗

The Response of a Quartz Crystal Microbalance to a Liquid Deposit

A theory was developed for predicting the loss of response of a QCM (Quartz Crystal Microbalance) to a liquid deposit due to viscous effects in the deposit. The loss of response is expressed by a response factor, equal to the response of the QCM to a liquid film divided by its response to a solid film of the same mass per unit area. The theory assumes a droplet-type deposit morphology, and considers the influence of droplet distribution parameters. Experiments were conducted to examine the validity of the theory, using DC 704 silicone oil as the subject deposit material. Experiments were made in two series: one with constant deposit mass and variable temperature, the other with variable deposit mass and constant temperature. Interpretation of the data using the theory has enabled information on droplet area coverage and number density to be deduced.

Glassford, A. P. M.↗