Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pulse Reactor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Experimental validation of an 8 element EMAT phased array probe for longitudinal wave generation

Sodium cooled Fast Reactors (SFR) use liquid sodium as a coolant. Liquid sodium being opaque, optical techniques cannot be applied to reactor vessel inspection. This makes it necessary to develop alternative ways of assessing the state of the structures immersed in the medium. Ultrasonic pressure waves are well suited for inspection tasks in this environment, especially using pulsed electromagnetic acoustic transducers (EMAT) that generate the ultrasound directly in the liquid sodium. The work carried out at CEA LIST is aimed at developing phased array EMAT probes conditioned for reactor use. The present work focuses on the experimental validation of a newly manufactured 8 element probe which was designed for beam forming imaging in a liquid sodium environment. A parametric study is carried out to determine the optimal setup of the magnetic assembly used in this probe. First laboratory tests on an aluminium block show that the probe has the required beam steering capabilities.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Transient Reactor Test Facility (TREAT)

TREAT operated from 1959-1994, later refurbished & resumed operation in 2017 to support fuel safety testing Zircaloy-clad graphite/fuel blocks comprise core Virtually any power history possible within ~2000 MJ core transient energy capacity From milliseconds to minutes: Pulses, Ramps, LOCA Fuel motion monitoring system “hodoscope” observes fast neutrons emitted from specimens to track fuel relocation in real time Reactor also can be a neutron source to adjacent radiography facility Experiment vehicle does everything else Safety containment, specimen environment, and instrumentation

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Tritium permeability measurement in hydrogen-tritium system

Fusion power promises to provide electricity generation with outstanding safety and environmental performance. Safety plays a crucial role in fusion material selection since tritium behavior in materials determines two key safety evaluation source terms: in-vessel inventory source term and ex-vessel release term, which are used in reactor safety assessments for licensing fusion facilities. Tritium permeation through materials at elevated temperature during long pulse operation expected in a burning plasma environment will become a major safety issue and development of tritium permeation barrier materials is required to minimize ex-vessel release to the environment [1]. Extensive work on hydrogen and deuterium behavior in fusion materials has been conducted, but very little database is available for tritium, the radioactive fuel for future reactors, due to the cost and difficulty associated with handling tritium [2]. A majority of the experiments were carried out at high hydrogen/deuterium partial pressure (> 100 Pa), but the expected tritium partial pressure in the blanket system is at low tritium partial pressure (< 100 Pa), where the tritium behavior deviates from diffusion-limited to surface-limited permeation. At these pressures the behavior of tritium is suspected to deviate from diffusion-limited to surface-limited permeation or isotope-limited [3]. The use of tritium enables us to investigate hydrogen isotope behavior in low partial pressure range with beta radiation detection. The physics of two-component hydrogen (H+T) permeation through metal in the surface-limited regime and through liquid breeding material are still too poorly understood to confidently design environmentally benign and safe fusion systems. In this paper, we discuss development of tritium permeation system for low tritium partial pressure [4], and discuss the results from two-component hydrogen (H+T) permeation in 20 mm disc samples of pure alpha-iron at H2 partial pressure of 100 Pa, wide T2 partial pressure range from 10-12 to 10 Pa, and sample temperature up to 600 °C to uncover the basic scientific understanding of tritium permeation behavior at realistic blanket conditions for DEMO. [1] FESAC report on “Opportunities for Fusion Materials Science and Technology Research Now and During the ITER Era” (2012) DOE/SC-0149 [2] R.A. Causey, R.A. Karnesky, and C. San Marchi, “4.16 Tritium Barriers and Tritium Diffusion in Fusion Reactors”, Comprehensive Nuclear Materials (2012) Chapter 4.16. [3] P. Humrickhouse “Permeation of Tritium and Hydrogen in the Diffusion-Limited and Surface–Limited Regimes”, submitted to Journal of Nuclear Materials. [4] R.J. Pawelko, M. Shimada, K. Katayama, S. Fukada, P.W. Humrickhouse, and T. Terai, “Low tritium partial pressure permeation system for mass transport measurement in lead lithium eutectic”, Fusion Engineering and Design 102 (2016) 8

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A stilbene–strontium iodide based radioxenon detection system for monitoring nuclear explosions

Atmospheric measurement of noble gases has been extensively used for monitoring clandestine nuclear weapon explosions for many years. The ratios of four xenon isotopes of interest ( 131 mXe, 133 mXe, 133 Xe, and 135 Xe) help in discriminating regular reactor operations from nuclear tests. A new coincidence-based detection system using stilbene and strontium iodide [SrI 2 (Eu)] for electron and photon detection respectively was developed at Oregon State University to address some of the challenges of the radioxenon systems deployed in the field such as memory effect, and poor energy resolution. Silicon photomultipliers (SiPMs) were used for sensing optical photons from all scintillation media. Real-time coincidence identification was achieved using the eight-channel digital pulse processor. The detection system was evaluated using lab check sources and Oregon State TRIGA reactor irradiated radioxenon samples. A 48-hour background coincidence spectrum was collected yielding a coincidence count rate and background rejection rate of 0.0174 ± 0.0003 counts per second (cps) and 98.9% respectively. The minimum detectable concentration (MDC) of the system was evaluated to be 0.11 ± 0.01, 0.13 ± 0.02, 0.20 ± 0.02, and 0.73 ± 0.08 for 131 mXe, 133 mXe, 133 Xe, and 135 Xe respectively. The memory effect of the detection system was found to be 0.069 ± 0.015%, which is almost a 70-fold reduction compared to traditional plastic scintillators. Here, the detection elements, custom-designed electronics, and the detector response to radioxenon are detailed in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of Advanced Experimental and Theoretical Characterization of Hydrogen Dynamics and Associated Behavior in Advanced Reactors

Advanced materials development, manufacturing, and modeling capabilities for innovative reactor designs support nuclear security and mission-focused science through enhanced technology for safer and more efficient and secure production of nuclear energy. The research in this project has established: 1) a state-of-the-art neutron-based hydrogen mapping and cross-section measurement capability as well as detailed crystallographic characterization of hydrogen atoms at LANSCE, and 2) a multi-physics framework for simulating behavior of moderator materials and other material performance in advanced nuclear reactors. Through the course of this project, we successfully developed and demonstrated measurement techniques for hydrogen distribution and atomistic-scale behavior of hydrogen atoms using pulsed neutron techniques. In parallel, advanced multi-physics simulation tools to predict the behavior of hydrogen atoms, e.g. in a moderator for a nuclear reactor, through materials performance, neutron transport, and thermal mechanical behavior were enhanced. Multi-discipline areas across the laboratory were involved in the project as the integration of improved experimental capabilities with enhanced modeling and simulation through MST, NEN, SIGMA, and XCP division subject matter experts.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Overview of KSTAR initial operation

Since the successful first plasma generation in the middle of 2008, three experimental campaigns were successfully made for the KSTAR device, accompanied with a necessary upgrade in the power supply, heating, wall-conditioning and diagnostic systems. KSTAR was operated with the toroidal magnetic field up to 3.6 T and the circular and shaped plasmas with current up to 700 kA and pulse length of 7 s, have been achieved with limited capacity of PF magnet power supplies. The mission of the KSTAR experimental program is to achieve steady-state operations with high performance plasmas relevant to ITER and future reactors. The first phase (2008-2012) of operation of KSTAR is dedicated to the development of operational capabilities for a super-conducting device with relatively short pulse. Development of start-up scenario for a super-conducting tokamak and the understanding of magnetic field errors on start-up are one of the important issues to be resolved. Some specific operation techniques for a super-conducting device are also developed and tested. The second harmonic pre-ionization with 84 and 110 GHz gyrotrons is an example. Various parameters have been scanned to optimize the pre-ionization. Another example is the ICRF wall conditioning (ICWC), which was routinely applied during the shot to shot interval. The plasma operation window has been extended in terms of plasma beta and stability boundary. The achievement of high confinement mode was made in the last campaign with the first neutral beam injector and good wall conditioning. Plasma control has been applied in shape and position control and now a preliminary kinetic control scheme is being applied including plasma current and density. Advanced control schemes will be developed and tested in future operations including active profiles, heating and current drives and control coil-driven magnetic perturbation.

Kwon, M↗

Radioxenon signatures of molten salt reactors

Developments of molten salt reactor (MSR) technologies are making rapid progress across the globe. These reactor designs involve properly controlling radionuclides through off-gas systems. This work examines radioxenon emissions and assesses treaty detection technology to be used for monitoring. This work also includes a sensitivity study with ORIGEN on the nuclear forensic signals possible from a MSR. Multiple Isotope Ratio Comparison (MIRC) plots are used to compare the ratios of radioxenon isotopes in an MSR to a highly enriched uranium (HEU) reactor. Finally, the results show that MSR emissions may significantly overlap with signals produced in a HEU reactor and that changing reactor operations or retaining emissions in an off-gas system can significantly shift the radioxenon signature away from the HEU pulse.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Modeling Nondestructive Defect Detection in Additively Manufactured Metallic Structures for Nuclear Applications

The future of quickly, economically produced metallic nuclear reactor parts with minimal supply-chain dependence lies in Laser Powder Bed Fusion (LPBF) Additive Manufacturing (AM): a 3D printing method involving laser melting and net shaping stainless steel and Inconel metallic powder into a solid structure. However, intrinsic features in LPBF frequently leads to the formation of materials defects, such as pores, within 3D printed structures. As safe long-term use in energy applications requires knowledge of all relevant defects before deployment in a reactor, we must develop methods for nondestructive detection of these defects. We are investigating Pulsed Thermal Tomography (PTT), which is a non-contact nondestructive imaging method scalable to arbitrary structure size. Thermal tomography (TT) is a computational method for 3D spatial reconstruction of material thermal effusivity from flash or pulsed thermography temperature data cube. Thermography data cube consists of 2D surface temperature measurements at different times. The objective of the present work is to investigate limits on defect detection in AM metallic structures with PTT. To this effect, we modeled PTT with COMSOL heat transfer computer simulations. We developed a layered media COMSOL simulation consisting of a Stainless Steel 316 (SS316) plate with an internal layer of un-sintered SS316 powder. Thermophysical properties of the powder layer were modeled with equivalent volume mixing model. To account for partial sintering at the boundary of the defect, the transition between solid and powder layers was modeled as a Gaussian. Using data from COMSOL simulations, we reconstructed depth-dependent thermal effusivity, which allowed defect visibility estimation. A series of parametric studies determined that at 1mm depth, 50µm is the smallest detectable defect. In addition, classification of the defects which can lead to early fatigue of the metallic structure in a reactor is briefly discussed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fission-Fusion Neutron Source Progress Report Sept 30, 2009

In this report the authors describe the progress made in FY09 in evaluating the feasibility of a new concept for using the DT fusion reaction to produce intense pulses of 14 MeV neutrons. In this new scheme the heating of the DT is accomplished using fission fragments rather than ion beams as in conventional magnet confinement fusion schemes or lasers in inertial confinement schemes. As a source of fission fragments they propose using a dust reactor concept introduced some time ago by one of us (RC). An attractive feature of this approach is that there is no need for a large auxiliary power source to heat the DT plasma to the point where self-sustaining fusion become possible. Their scheme does require pulsed magnetic fields, but generating these fields requires only a modest power source. The dust reactor that they propose using for their neutron source would use micron-sized UC pellets suspended in a vacuum as the reactor fuel. Surrounding the fuel with a moderator such as heavy water (D{sub 2}O) would allow the reactor to operate as a thermal reactor and require only modest amounts of HEU. The scheme for using fission fragments to generate intense pulses of 14 MeV neutrons is based on the fission fragment rocket idea. In the fission fragment rocket scheme it was contemplated that the fission fragments produced in a low density reactor core could be guided out of the reactor by large magnetic fields used to form a 'rocket exhaust'. Their adaptation of this idea for the purposes of making a neutron source involves using the fission fragments escaping from one side of a tandem magnet mirror to heat DT gas confined in the adjacent magnetic trap.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Geant4 evaluation of the Hornyak button and two candidate detectors for the TREAT hodoscope

The performance of traditional Hornyak buttons and two proposed variants for fast-neutron hodoscope applications was evaluated using Geant4. The Hornyak button is a ZnS(Ag)-based device previously deployed at the Idaho National Laboratory's TRansient REActor Test Facility (better known as TREAT) for monitoring fast neutrons emitted during pulsing of fissile fuel samples. Past use of these devices relied on pulse-shape discrimination to reduce the significant levels of background Cherenkov radiation. Proposed are two simple designs that reduce the overall light guide mass (here, polymethyl methacrylate or PMMA), employ silicon photomultipliers (SiPMs), and can be operated using pulse-height discrimination alone to eliminate background noise to acceptable levels. Geant4 was first used to model a traditional Hornyak button, and for assumed, hodoscope-like conditions, an intrinsic efficiency of 0.35% for mono-directional fission neutrons was predicted. The predicted efficiency is in reasonably good agreement with experimental data from the literature and, hence, served to validate the physics models and approximations employed. Geant4 models were then developed to optimize the materials and geometries of two alternatives to the Hornyak button, one based on a homogeneous mixture of ZnS(Ag) and PMMA, and one based on alternating layers of ZnS(Ag) and PMMA oriented perpendicular to the incident neutron beam. For the same radiation environment, optimized, 5-cm long (along the beam path) devices of the homogeneous and layered designs were predicted to have efficiencies of approximately 1.3% and 3.3%, respectively. For longer devices, i.e., lengths larger than 25 cm, these efficiencies were shown to peak at approximately 2.2% and 5.9%, respectively. Furthermore, both designs were shown to discriminate Cherenkov noise intrinsically by using an appropriate pulse-height discriminator level, i.e., pulse-shape discrimination is not needed for these devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

VUV Photoionization Cross Sections of HO 2 , H 2 O 2 , and H 2 CO

The absolute vacuum ultraviolet (VUV) photoionization spectra of the hydroperoxyl radical (HO2), hydrogen peroxide (H 2 O 2 ), and formaldehyde (H2CO) have been measured from their first ionization thresholds to 12.008 eV. HO 2 , H 2 O 2 , and H 2 CO were generated from the oxidation of methanol initiated by pulsed-laser-photolysis of Cl 2 in a low-pressure slow flow reactor. Reactants, intermediates, and products were detected by time-resolved multiplexed synchrotron photoionization mass spectrometry. Absolute concentrations were obtained from the time-dependent photoion signals by modeling the kinetics of the methanol oxidation chemistry. Photoionization cross sections were determined at several photon energies relative to the cross section of methanol, which was in turn determined relative to that of propene. These measurements were used to place relative photoionization spectra of HO 2 , H 2 O 2 , and H 2 CO on an absolute scale, resulting in absolute photoionization spectra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Origin of a signal detected with the LSD detector after the accident at the chernobyl nuclear power plant

A rare signal was detected at 23:53 Moscow time on April 27, 1986 with the LSD low-background scintillation detector located under Mont Blanc at a distance of 1820 km from Chernobyl. To reveal the origin of this signal, we discuss the results obtained with other instruments operating within a similar program, as well as analyze the characteristics of the pulses of the signal and facts referring to the explosion of the Chernobyl reactor. A hypothesis based on detection with the LSD of gamma-quanta from {beta} decays of {sup 135}I nuclei ejected into atmosphere by the reactor explosion and carried in the underground detector camera with air of positive ventilation is considered. The explosion origin of the LSD signal indicates a new technogenic source of the background in the search for neutrino bursts from cores of collapsing stars.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility Study for a Combined Radiation Environment in the ACRR-FRECII Cavity.

The objective of this report is to determine the feasibility of a combined pulsed - power accelerator machine, similar to HERMES - III, with the Annular Core Research Reactor (ACRR) Fueled - Ring External Cavity (FREC - II) in a new facility. The document is conceptual in nature, and includes some neutronic analysis that i llustrates that that the physics of such a concept would be feasible. There would still be many engineering design considerations and issues that would need to be investigated in order to determine the true viability of such a concept. This report does n ot address engineering design details, the cost of such a facility, or what would be required to develop the safety authorization of the concept. The radiation requirements for the "on - target" gamma - ray dose and dose rate are not addressed in this report . It is assumed that if the same general on - target specifications for a HERMES - III type machine could be met with the proposed concept, that the machine would b e considered highly useful as a radiation effects sciences platform. In general, the combined accelerator/ACRR reactor concept can be shown to be feasible with no major issues that would preclude the usefulness of such a facility. The new facility would provide a capability that currently does not exist in the radiation testing complex.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Neutron Leakage Spectra Sensitivities for ICSBEP Benchmarks

Neutron leakage spectra have been measured, simulated, and investigated by many groups. These spectra have many uses, including determining shielding requirements and calculating dose for radiation protection purposes, validating nuclear data, and determining material composition. It has even been proposed to use measurements of neutron leakage spectra to determine the soil composition of Mars. As part of the Los Alamos National Laboratory (LANL) Experiments Underpinned by Computational Learning for Improvements in nuclear Data (EUCLID) Laboratory Directed Research Development (LDRD) project, the authors are working on developing methods to calculate sensitivities to neutron leakage spectra. This may allow nuclear data evaluators to better use neutron leakage spectra data to constrain or adjust nuclear data. This may also be particularly useful as many neutron leakage spectra measurements do not require fissile material and can be performed with well characterized neutron sources. Neutron leakage spectra measurements are usually performed by placing a detector at the outside of a nuclear system. This may be a reactor, a neutron generator, or a neutron source. Certain detection systems can use pulse height data to infer neutron energies, other detector systems rely on other ways of determining neutron energy (for example, a Bonner sphere with multiple moderator thicknesses can be used to measure neutron spectrum). These measurements typically rely on some unfolding of the measured results. For pulsed systems like the "Livermore Pulsed Spheres," time-of-flight information can also help to constrain the neutron energy spectra data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Developing the test conditions for the first fueled transients in the TREAT reactor

The restart of the Transient Reactor Test (TREAT) facility at Idaho National Laboratory, re-establishes a national in-pile testing capability for nuclear fuels in accident scenarios. The purpose of the first tests in TREAT are to study the response of nuclear fuel durring a reactivity initiated accident (RIA). The initial objective is to demonstrate the ability to create a desired enthalpy increase in a representative fuel test specimen over a desired time step and to better understand the uncertainty. The five test rods initially available for these irradiations are UO2-Zircaloy with standard Pressurized Water Reactor (PWR) geometry. The rods are 15 cm long with 9 cm of active fuel. The initial testing environment is dry helium. BISON fuel performance calculations were run to model the heat transfer during postulated transients. Based on those results energy deposition targets were selected around the range of observable phenomena in the testing environment. Reactor / experiment power coupling factors, step insertion size and transient clipping response times were then calculated using results from a RELAP point kinetics model. Calculated energy deposition targets are 150, 350, 650, 960, and 1300 J/gUO2. The energy coupling factor for the experiments was calculated to be ~1.5 J/gUO2-MJ. Two step insertion sizes were selected: a 0.6% ?k/k step for the 150 J/g transient and a 1.8% ?k/k step for the other transients. Clipping response times ranged from 1.3 seconds to unclipped transients. The experiments will be irradiated in the TREAT facility in the fall of 2018. The first transient will be the 150 J/g pulse with a 0.6% ?k/k step that is unclipped. Follow on tests may modify the reactor operating parameters based on results from previous transients. Any preliminary data available on the results of the transients at the time of the NUMAT Conference will be presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Behavior of high-burnup advanced LWR fuels under accident conditions

Advanced fuels for LWRs which consist of cladding materials with high corrosion resistance and pellets with lower fission gas release have been developed by utilities and fuel vendors to improve the fuel performance even in the high burnup region and also raise the safety level of current nuclear power plants to a higher one. In order to evaluate the adequacy of present safety criteria and safety margins in terms of such advanced fuels and provide a database for future regulation of them, JAEA has started a new extensive research program called ALPS-II program. The ALPS-II program is primarily composed of tests simulating a RIA (Reactivity Initiated Accident) (VA-5 and -6 tests) and a LOCA (Loss Of Coolant Accident) on high burnup advanced fuels irradiated in commercial PWR or BWRs and started in JFY 2008. Recently, post-test examinations on the fuel rods after the pulse irradiation tests of VA-5 and -6 were performed and the relationship between the failure limits of the high burnup advanced fuels with M-MDA{sup TM} cladding and the morphology of the hydrides precipitated in the cladding during normal operation was investigated. The difference in the crack surface morphology was observed between tests VA-5 and-6, which seemed to reflect the difference in the direction along which hydrides precipitate in the cladding. This indicates that the hydride precipitated in the cladding, which is considered to be dependent on the final heat treatment at fabrication, affects the fuel enthalpy at failure. In terms of the simulated LOCA test, integral thermal shock tests and high temperature oxidation tests have been conducted on high burnup PWR and BWR fuel cladding with advanced materials, and their fracture limits, high temperature oxidation rates, etc. were investigated. In the recent integral thermal shock tests for high burnup BWR cladding, namely Zry-2/LK3 material, no fractures were observed. In terms of the oxidation rate tests, the oxidation rate of irradiated M5{sup TM} was similar to those of unirradiated Zry-4 and M5{sup TM} and lower than the values estimated by the Baker-Just equation. From the results of these tests, it was found that in terms of these materials the fracture boundaries do not decrease and the oxidation does not significantly accelerate in the burnup level examined.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Detecting Microbially Induced Calcite Precipitation in a Model Well-Bore Using Downhole Low-Field NMR

Microbially induced calcite precipitation (MICP) has been widely researched recently due to its relevance for subsurface engineering applications including sealing leakage pathways and permeability modification. These applications of MICP are inherently difficult to monitor nondestructively in time and space. Nuclear magnetic resonance (NMR) can characterize the pore size distributions, porosity, and permeability of subsurface formations. This investigation used a low-field NMR well-logging probe to monitor MICP in a sand-filled bioreactor, measuring NMR signal amplitude and T 2 relaxation over an 8 day experimental period. Following inoculation with the ureolytic bacteria, Sporosarcina pasteurii , and pulsed injections of urea and calcium substrate, the NMR measured water content in the reactor decreased to 76% of its initial value. T 2 relaxation distributions bifurcated from a single mode centered about approximately 650 ms into a fast decaying population ( T 2 less than 10 ms) and a larger population with T 2 greater than 1000 ms. The combination of changes in pore volume and surface minerology accounts for the changes in the T 2 distributions. Destructive sampling confirmed final porosity was approximately 88% of the original value. Here, these results indicate the low-field NMR well-logging probe is sensitive to the physical and chemical changes caused by MICP in a laboratory bioreactor.

54 ENVIRONMENTAL SCIENCES↗

Deuterium-tritium neutron yield measurements with the 4.5 m neutron-time-of-flight detectors at NIF

The first several campaigns of laser fusion experiments at the National Ignition Facility (NIF) included a family of high-sensitivity scintillator/photodetector neutron-time-of-flight (nTOF) detectors for measuring deuterium-deuterium (DD) and DT neutron yields. The detectors provided consistent neutron yield (Y{sub n}) measurements from below 10{sup 9} (DD) to nearly 10{sup 15} (DT). The detectors initially demonstrated detector-to-detector Y{sub n} precisions better than 5%, but lacked in situ absolute calibrations. Recent experiments at NIF now have provided in situ DT yield calibration data that establish the absolute sensitivity of the 4.5 m differential tissue harmonic imaging (DTHI) detector with an accuracy of {+-}10% and precision of {+-}1%. The 4.5 m nTOF calibration measurements also have helped to establish improved detector impulse response functions and data analysis methods, which have contributed to improving the accuracy of the Y{sub n} measurements. These advances have also helped to extend the usefulness of nTOF measurements of ion temperature and downscattered neutron ratio (neutron yield 10-12 MeV divided by yield 13-15 MeV) with other nTOF detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗