Changes in the high state of AM Herculis - A simultaneous X-ray, optical, polarimetric, and spectroscopic study

Simultaneous UBVR photometry, circular polarimetry, and high resolution spectroscopy observations (during May, 1979), coordinated with a monitor proportional counter and a solid state spectrometer, are reported for the cataclysmic variable AM Her, when it was in its normal 'high' state, where the mean visual magnitude was 12.5 mag versus 15 mag for the infrequent 'low' state. The circular polarization was always negative and had the smallest peak to peak amplitude yet reported. The emission lines He II 4686, H-beta, N III 4634, N III 4640-4641, C III 4650-4651, and He I 4713 present at least two components identified with the broad and sharp components of Greenstein at al. (1977). The radial velocity curve of the broad component shows a 50% reduction of amplitude in comparison to their values, and a third very broad component in 4686 is identified. No correlation between the optical photometry and 1-10 keV X-ray intensity was found on flickering time scales. Results of the observations are discussed within the framework of models with accretion onto one or both magnetic poles of the white dwarf.

Crosa, L.↗

X-ray detection of the symbiotic star AG Draconis

The detection of the yellow symbiotic star AG Draconis is reported. The star was detected by an imaging proportional counter at a count rate of 0.27 counts/s. The object is an intense source of very soft X-rays, and the X-ray luminosity is estimated to be equal to approximately 10 to the 32nd ergs/s, with a temperature of less than 2,000,000 K. If an interstellar column density of 3 x 10 to the 20th/sq cm is assumed, the emission measure is deduced to be greater than 3 x 10 to the 55th/ cu cm from the X-ray data, and less than 3 x 10 to the 59th/cu cm from the optical data. The observation is discussed in the context of various models of the symbiotic stars.

Anderson, C. M.↗

An X-ray active region in Orion - X-rays from a Herbig-Haro object

The Imaging Proportional Counter on the Einstein X-ray Observatory has observed an approximately 1.0 deg square region in Orion centered near right ascension (1950) = 5 hours 34 min, declination = -6 deg 47 arcmin. This is an area containing a dark cloud with evidence for recent star formation and several Herbig-Haro objects. Some 25 stellar X-ray sources are found, and several are identified with stars which have X-ray luminosities at the upper end of the distribution of X-ray luminosity versus stellar type. In addition there is evidence for X-ray emission associated with HH 1 which can provide support for models which include strong stellar winds interacting with the interstellar medium.

Pravdo, S. H.↗

The Einstein Observatory and future X-ray telescopes

A history of the events leading to the development and flight of the Einstein Observatory is given. The advantages of using grazing-incidence telescopes for solar and extrasolar X-ray astronomy is first discussed and followed by a description of the HEAO program. The Einstein Observatory marks a departure from the manner in which X-ray investigations are carried out, from individual experiments to the shared use of large facilities. The Observatory has achieved a sensitivity to point sources of 10 to the -14th erg/sq cm-sec in the 1-3 keV band, a flux 500 times smaller than previously detected and about 10 million times smaller than that of the first extrasolar source detected in 1962. The design philosophy of the Observatory entails three principles: (1) the unified scientific approach, (2) the establishment of spacecraft requirements at lowest acceptable levels that still allow operating flexibility, and (3) the idea of 'soft' rather than 'hard' failure. The mirror design, including the high resolution imager, the imaging proportional counter, and the solid-state and focal plane crystal spectrometers, is also given. An account of the struggle to gain acceptance by the scientific community and the funding agencies of the need for the Einstein Observatory mission is discussed. Finally, results of observations made by the Observatory are presented in detail, along with plans for future observation experiments.

Giacconi, R.↗

Spectroscopy in X-ray astronomy

Detailed features in cosmic X-ray sources and their associated temporal variation over a wide energy range were studied. Excess emission and absorption at approximately 6 to 7 kiloelectron volts in the spectra of supernova remnants, binary X-ray sources, and clusters of galaxies were observed. A gas scintillation proportional counter (GSPC) will be used as the detector system. In the gas scintillator the principal limitation is due to the statistics of the initial ionization process only.

Andresen, R.↗

Develop real-time dosimetry concepts and instrumentation for long term missions

The development of a rugged portable instrument to evaluate dose and dose equivalent is described. A tissue-equivalent proportional counter simulating a 2 micrometer spherical tissue volume was operated satisfactorily for over a year. The basic elements of the electronic system were designed and tested. And finally, the most suitable mathematical technique for evaluating dose equivalent with a portable instrument was selected. Design and fabrication of a portable prototype, based on the previously tested circuits, is underway.

Braby, L. A.↗

An X-ray study of the galactic center

The results from two long observations with the Einstein Observatory Imaging Proportional Counter (IPC) of an approximately 1 x 1 deg field centered near the galactic nucleus are presented. The X-ray images reveal a complex of weak sources within 20 arcmin of the galactic nucleus (Sgr A West) together with a region of apparently diffuse emission about 25 x 15 arcmin in extent. Three of the sources are tentatively identified: two with nearby galactic objects, and a third positionally coincident with Sgr A West itself (within the arcmin-accuracy available with the IPC). The nature of this source and the implications of both the high source density and presence of diffuse emission in the galactic center region are discussed.

Watson, M. G.↗

X-ray emission from Of stars and OB supergiants

The result of a survey of X-ray emission from luminous early-type stars is reported in which observations were made using the imaging proportional counter on the Einstein Observatory. The survey suggests that all Of stars and OB supergiants earlier than B1 I are X-ray sources with luminosities not less than 10 to the 32nd ergs/s and that some later B supergiants have X-ray luminosities not less than 10 to the 31st ergs/s. The X-ray luminosities are roughly 10 to the -7.2nd of the bolometric luminosities for supergiants earlier than B1 and perhaps a factor of 3 less for later B supergiants. Spectral analysis of the X-rays in conjunction with information on anomalous ionization in the wind from four of the strongest sources implies that the data are not consistent with a model in which the X-rays originate in a thin slab coronal zone at the base of the wind. Constraints on the source of X-rays from B supergiants are derived by combining the X-ray flux information with that on ultraviolet line anomalies.

Cassinelli, J. P.↗

The correlation of X-ray emission with strong millimeter activity in extragalactic sources

A sample of 25 strong extragalactic millimeter sources have been observed at about 1 keV with the Imaging Proportional Counter on the Einstein X-Ray Observatory and at 90 GHz with the NRAO 11 m telescope. A strong correlation between the millimeter and X-ray flux densities is found. This result is consistent with a synchronous self-Compton model in which the X-ray emission arises from the Compton scattering of millimeter radio photons off the relativistic electrons which created them.

Owen, F. N.↗

Search for high frequency pulsations in the onset of the March 5 gamma-ray burst

The onset of the March 5 Gamma-Ray burst was observed with microsecond time resolution by the Monitor Proportional Counter aboard the HEAO-2/Einstein Observatory. The data were analyzed for high frequency periodic pulsations which, if present, would be strong evidence for vibrations of a neutron star following the initial release of energy. Evidence is not found for such pulsations in the data over the period range 29.4737 to 0.0962 ms, and upper limits to the amplitude of 49-70% are set.

Weisskopf, M. C.↗

Einstein observations of the galactic centre

A description is presented of the X-ray observations made with the Einstein Observatory Imaging Proportional Counter of a 1 x 1 degree field centered near the galactic nucleus. In the direction of the galactic center the interstellar medium is generally opaque to all radiation between the visual and extreme ultraviolet due to the large column density of the intervening gas and dust. The importance of this X-ray study lies in the fact that it opens up a new window in which the central regions of the Milky Way Galaxy can be observed. The X-ray image is clearly dominated by a bright, central region of emission elongated along the galactic plane. Also presented are a number of unresolved sources.

Watson, M. G.↗

X-ray observations of cataclysmic variables

Cataclysmic variables (CVs) as a class are defined by their optical properties, in particular the amplitudes and frequency of their outbursts. The availability of the Imaging Proportional Counter (IPC) on the Einstein Laboratory has increased significantly the number of CVs which can be studied on the basis of X-ray observations. In this connection, Becker and Marshall (1981) and Cordova et al. (1980) have surveyed 20 CVs and detected 70% of them. A description is presented of observations of an additional 12 CVs, and the properties of the combined set of 32 CVs are discussed. It is found that the CVs do not have any distinguishing X-ray characteristics. The IPC data alone cannot be used to determine to which category of CVs a particular source belongs, or even to identify an object as a CV. On the other hand, the optical observations are essential for estimating the X-ray luminosity from the IPC data.

Becker, R. H.↗

Detection of X-rays during the outburst of supernova 1980k

X-ray emission from SN 1980k in NGC 6946 was detected about 35 days after maximum light using the imaging proportional counter on the Einstein Observatory. The absorption corrected X-ray flux of SN 1980k was about 0.03 micro-Jy at 0.24 x 10 to the 18th Hz (1 keV), which corresponds to a luminosity of about 2 x 10 to the 39th ergs/s (0.2-4 keV) at 10 Mpc. This detection of radio emission suggests the presence of relativistic electrons and a magnetic field strength of not greater than about 1 gauss. Inverse Compton scattering of the optical photons on the electrons can explain the X-ray emission without additional ad hoc assumptions, although other emission mechanisms are possible.

Canizares, C. R.↗

An unbiased survey of field star X-ray emission

To determine the X-ray luminosity function of normal stars, 1700 stars brighter than 10th magnitude were surveyed by the imaging proportional counter aboard the Einstein Observatory. Seventy star positions were found to contain excess X-ray counting rates. The number of stars per square degree in a number of magnitude intervals was calculated as a function of spectral type and luminosity class, and the total number of stars for each spectral type brighter than magnitude 9.5 derived in this manner was compared with the 1700-star sample. The agreement is good, as is that between the surface density of soft X-ray sources and the number of stellar emitters predicted from the field star survey. It is concluded that stars probably do not contribute significantly to the diffuse soft X-ray background. The findings are consistent with the notion that stellar age and/or rotation velocity are important determinants of stellar X-ray emission level.

Helfand, D. J.↗

Towards understanding solar flares

Instrumentation and spacecraft payloads developed at Lockheed for solar flare studies are reviewed, noting the significance of the observations for adding to a data base for eventual prediction of the occurrence of flares and subsequent radiation hazards to people in space. Developmental work on the two solar telescopes on board the Skylab pallet was performed at a Lockheed facility, as was the fabrication of very-large-area proportional counter for flights on the Aerobee rocket in 1967. The rocket work led to the fabrication of the Mapping X Ray Heliometer on the Orbiting Solar Observatory and the X Ray Polychromator for the Solar Maximum Mission. The Polychromator consists of a bent crystal spectrometer for high time resolution flare studies over a wide field of view, and a flat crystal spectrometer for simultaneous polychromatic imaging at 7 different X ray wavelengths.

Acton, L. W.↗

Einstein observations of the 1978 November 19 gamma ray burst source field

It is pointed out that several years after the discovery of cosmic gamma ray bursts (GRB) their sources have not yet been identified, although searches have been conducted in optical, X-ray, and radio wavelengths. The three smallest error boxes are now related to the events of Mar. 5, 1979, Apr. 6, 1979, and Nov. 19, 1978. X-ray observations, with the Imaging Proportional Counter (IPC) of the Einstein Observatory, were made for all three locations. A description is presented of the results of the 8200 second IPC observation of the Nov. 19, 1978 GRB, made on July 1 and 2, 1980. Three sources were detected. However, two of them were outside the GRB error box. The third source is located well inside the burst error box.

Pizzichini, G.↗

X-ray sources in globular clusters

The Einstein X-ray Observatory globular cluster observation program has completed a survey of 30 clusters, using the HRI detector. Preliminary results are reported for a more sensitive survey being conducted with the imaging proportional counter (IPC) of the satellite, which has found four possible new sources in the first 32 clusters observed. Also described are detailed studies of several luminous, globular cluster sources, including the X-ray burst from Terzan 2, and an effort is made to locate the X-ray sources with respect to cluster centers. Sources of systematic error, required optical studies of globular cluster structure, and the implications of the plausible binary systems for cluster core evolution are discussed.

Grindlay, J. E.↗