Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Chandra Observations of the Anomalous X-ray Pulsar 4U 0142+61

We present X-ray imaging, timing, and phase resolved spectroscopy of the anomalous X-ray pulsar 4U 0142+61 using the Chandra X-ray Observatory. The spectrum is well described by a power law plus blackbody model with Gamma = 3.35(2), kT=0.458(3) keV, and N-H = 0.91(2) x 10(exp 22)/sq cm); we find no significant evidence for spectral features (0.5 - 7.0 keV). Time resolved X-ray spectroscopy shows evidence for evolution in phase in either Gamma, or kT or some combination thereof as a function of pulse phase. We derive a precise X-ray position for the source and determine its spin period, P=8.68866(30) s. We have detected emission beyond 4 arcsec from the central source and extending beyond 100 arcsec, likely due to dust scattering in the interstellar medium.

Patel, Sandeep K.↗

Constraining the oblateness of transiting planets with photometry and spectroscopy

ABSTRACT Rapid planetary rotation can cause the equilibrium shape of a planet to be oblate. While planetary oblateness has mostly been probed by examining the subtle ingress and egress features in photometric transit light curves, we investigate the effect of oblateness on the spectroscopic Rossiter–McLaughlin (RM) signals. We found that a giant planet, with planet-to-star radius ratio of 0.15 and Saturn-like oblateness of 0.098, can cause spectroscopic signatures with amplitudes up to 1.1 m s−1 which is detectable by high-precision spectrographs such as ESPRESSO. We also found that the spectroscopic oblateness signals are particularly amplified for transits across rapidly rotating stars and for planets with spin-orbit misalignment thereby making them more prominent than the photometric signals at some transit orientations. We compared the detectability of oblateness in photometry and spectroscopy and found that photometric light curves are more sensitive to detecting oblateness than the spectroscopic RM signals mostly because they can be sampled with higher cadence to better probe the oblateness ingress and egress anomaly. However, joint analyses of the light curve and RM signal of a transiting planet provides more accurate and precise estimate of the planet’s oblateness. Therefore, ESPRESSO alongside ongoing and upcoming photometric instruments such as TESS, CHEOPS, PLATO, and JWST will be extremely useful in measuring planet oblateness.

Akinsanmi, B.↗

Tunable Few-Layer van der Waals Crystals and Heterostructures as Emerging Energy and Quantum Materials (Final Technical Report)

2D and layered (van der Waals) semiconductors offer extraordinary opportunities for manipulating optically excited charge carriers, many-body excitations, and non-charge based quantum numbers. To date, research has focused on a limited group of materials, mostly transition metal dichalcogenides in the monolayer limit. Other van der Waals semiconductors, and especially few-layer to multilayer crystals and their heterostructures, carry large potential for the discovery of phenomena of interest for future energy and information technologies. But they remain largely unexplored, often due to a lack of access to high-quality materials and approaches for measuring their properties at the relevant scales. The goal of this project was to develop an EPSCoR-State/National Laboratory Partnership that addresses the challenges of preparing high-quality van der Waals semiconductors and of probing their structure, composition, and especially their optoelectronic and photonic properties, near the atomic scale using electron microscopy techniques. A central component of the project was the development of advanced methods for electron microscopy and electron-excited spectroscopy, taking advantage of unique samples as well as leading capabilities and expertise at the partner institutions. Efforts to advance leading-edge techniques was supported by ancillary developments, such as precision sample preparation for electron microscopy/spectroscopy, coordinated chemical imaging, and analytical electron microscopy. Experiments in materials synthesis and technique development were closely linked to theory and computation. The results obtained under this project yielded multifaceted benefits to the involved partners and their institutions, DOE-BES, the wider scientific community, and society at large, particularly in the State of Nebraska through dividends from knowledge and human capital generated under the project.

36 MATERIALS SCIENCE↗

Improved precision in As speciation analysis with HERFD-XANES at the As K -edge: the case of As speciation in mine waste

High-energy-resolution fluorescence-detected (HERFD) X-ray absorption near-edge spectroscopy (XANES) is a spectroscopic method that allows for increased spectral feature resolution, and greater selectivity to decrease complex matrix effects compared with conventional XANES. XANES is an ideal tool for speciation of elements in solid-phase environmental samples. Accurate speciation of As in mine waste materials is important for understanding the mobility and toxicity of As in near-surface environments. In this study, linear combination fitting (LCF) was performed on synthetic spectra generated from mixtures of eight measured reference compounds for both HERFD-XANES and transmission-detected XANES to evaluate the improvement in quantitative speciation with HERFD-XANES spectra. The reference compounds arsenolite (As 2 O 3 ), orpiment (As 2 S 3 ), getchellite (AsSbS 3 ), arsenopyrite (FeAsS), kaňkite (FeAsO 4 ·3.5H 2 O), scorodite (FeAsO 4 ·2H 2 O), sodium arsenate (Na 3 AsO 4 ), and realgar (As 4 S 4 ) were selected for their importance in mine waste systems. Statistical methods of principal component analysis and target transformation were employed to determine whether HERFD improves identification of the components in a dataset of mixtures of reference compounds. LCF was performed on HERFD- and total fluorescence yield (TFY)-XANES spectra collected from mine waste samples. Arsenopyrite, arsenolite, orpiment, and sodium arsenate were more accurately identified in the synthetic HERFD-XANES spectra compared with the transmission-XANES spectra. In mine waste samples containing arsenopyrite and either scorodite or kaňkite, LCF with HERFD-XANES measurements resulted in fits with smaller R -factors than concurrently collected TFY measurements. The improved accuracy of HERFD-XANES analysis may provide enhanced delineation of As phases controlling biogeochemical reactions in mine wastes, contaminated soils, and remediation systems.

58 GEOSCIENCES↗

Revealing Nanoscale Confinement Effects on Hyperbolic Phonon Polaritons with an Electron Beam

Hyperbolic phonon polaritons (HPhPs) in hexagonal boron nitride (hBN) enable the direct manipulation of mid-infrared light at nanometer scales, many orders of magnitude below the free-space light wavelength. High-resolution monochromated electron energy-loss spectroscopy (EELS) facilitates measurement of excitations with energies extending into the mid-infrared while maintaining nanoscale spatial resolution, making it ideal for detecting HPhPs. The electron beam is a precise source and probe of HPhPs, which allows the observation of nanoscale confinement in HPhP structures and directly extract hBN polariton dispersions for both modes in the bulk of the flake and modes along the edge. The measurements reveal technologically important nontrivial phenomena, such as localized polaritons induced by environmental heterogeneity, enhanced and suppressed excitation due to 2D interference, and strong modification of high-momenta excitations such as edge-confined polaritons by nanoscale heterogeneity on edge boundaries. Finally, the work opens exciting prospects for the design of real-world optical mid-infrared devices based on hyperbolic polaritons.

2D materials↗

Vapor Phase Installation of CpCo(CO) 2 in MOF‐808

Metal-organic frameworks (MOFs), including MOF-808 present an opportunity for vapor phase installation of reactive centers that may serve as uniform sites for precision catalysis. The mechanism of cobalt installation in MOF-808 through atomic layer deposition (ALD) upon CpCo(CO )2 exposure is investigated through in situ FTIR spectroscopy complemented by density functional theory modeling. The role of subsequent H 2 O exposure in the hydrolysis of carbonyl and cyclopentadienyl ligands to complete the installation is also investigated. In situ FTIR study reveals that upon exposure of CpCo(CO) 2 to MOF-808 at 115 °C, a long-lived, stable intermediate is formed that presents carbonyl stretching vibrations similar to the undissociated precursor that are attributed to multiple chemisorbed carbonyl complexes. In MOF-808, cobalt species are initially absorbed near the BTC linker rather than directly on the nodes, revealing the importance of non-covalent interactions in the installation process. DFT suggests that H 2 O exposure promotes carbonyl elimination but leaves a cyclopentadienyl-capped cobalt that is more stable than the complete hydrolysis product. The simulations are consistent with cobalt installation in MOF-808 using CpCo(CO) 2 and H 2 O at 115 °C and further consistent with the lack of ALD thin film deposition of cobalt oxide thin films on planar supports.

36 MATERIALS SCIENCE↗

Limits of Detection for EXAFS Characterization of Heterogeneous Single-Atom Catalysts

Single-atom catalysts (SACs), consisting of individual metal atoms dispersed on a support, attract attention due to their unique reactivity, efficient use of precious metals, and precise chemical tunability. Characterization of the metal species is crucial to substantiate structure–function relationships. Authors often use—and referees often require—X-ray absorption spectroscopy (XAS) data to prove the absence of clustered metal (or metal oxide) structures after pre-treatment and under in situ or operando conditions. However, there has been no critical assessment of the limitations of XAS in substantiating such conclusive statements, which is particularly important given the potential outsized influence of minority catalyst structures in dictating catalytic activity. Here, in this article, we quantitatively assess the detection limits of XAS to identify metal (or metal oxide) clusters in samples containing predominantly single atoms by modeling the extended X-ray absorption fine structure (EXAFS) of mixtures of structures. We identified that a significant fraction of clusters can coexist with SAC active sites (e.g., ~10% metallic Pt or ~40% oxidized Pt clusters in Pt/CeO 2 SACs), while eluding detection via EXAFS with any statistical significance. To generalize these conclusions, a descriptor-based screening of bulk metal oxides using a continuous Cauchy wavelet transform was proposed that suggests certain materials for which differentiating atomically dispersed metal species and metal oxide clusters would be infeasible by EXAFS (e.g., ReO x ). Based on this analysis, we suggest best practices for the study of SACs using EXAFS and provide recommendations to ensure that conclusions do not outpace the evidence used to support them. In this rapidly expanding research area, rigorous characterization will lead to greater understanding of the behavior of SACs and ultimately improved catalytic materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uranium Single Particle Analysis for Simultaneous Fluorine and Uranium Isotopic Determinations via Laser-Induced Breakdown Spectroscopy/Laser Ablation–Multicollector–Inductively Coupled Plasma–Mass Spectrometry

Uranyl fluoride (UO 2 F 2 ) particles (<20 μm) were subjected to first-of-its-kind analysis via simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation multi-collector inductively coupled plasma–mass spectrometry (LA–MC–ICP–MS). Briefly, a nanosecond pulsed high-energy laser was focused onto the sample (particle) surface. In a single laser pulse, the UO 2 F 2 particle was excited/ionized within the microplasma volume, and the emission of light was collected via fiber optics such that emission spectroscopy could be employed for the detection of uranium (U) and fluorine (F). The ablated particle was simultaneously transported into the MC–ICP–MS for high precision isotopic (i.e., 234 U, 235 U, and 238 U) analysis. This method, LIBS/LA–MC–ICP–MS was optimized and employed to rapidly measure 80+ UO 2 F 2 particles, which were subjected to different calcination processes, which results in varying degrees of F loss from the individual particles. In measuring the particles, the average F/U ratios for the populations treated at 100 and 500 °C were 2.78 ± 1.28 and 1.01 ± 0.50, respectively, confirming loss of F through the calcination process. The average 235 U/ 238 U on the particle populations for the 100 and 500 °C were 0.007262 (22) and 0.007231 (23), which was determined to be <0.2% from the expected value. The 234 U/ 238 U ratios on the same particles were 0.000053 (11) and 0.000050 (10) for the 100 and 500 °C, respectively, <10% from the expected value. Notably, each population was analyzed in under 5 min, demonstrating the truly rapid analysis technique presented here in this paper.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Toward monochromated sub-nanometer UEM and femtosecond UED

A preliminary design of a mega-electron-volt (MeV) monochromator with 10 –5 energy spread for ultrafast electron diffraction (UED) and ultrafast electron microscopy (UEM) is presented. Such a narrow energy spread is advantageous in both the single shot mode, where the momentum resolution in diffraction is improved, and the accumulation mode, where shot-to-shot energy jitter is reduced. In the single-shot mode, we numerically optimized the monochromator efficiency up to 13% achieving 1.3 million electrons per pulse. In the accumulation mode, to mitigate the efficiency degradation caused by the shot-to-shot energy jitter, an optimized gun phase yields only a mild reduction of the single-shot efficiency, therefore the number of accumulated electrons nearly proportional to the repetition rate. Inspired by the recent work of Qi et al. (Phys Rev Lett 124:134803, 2020), a novel concept of applying reverse bending magnets to adjust the energy-dependent path length difference has been successfully realized in designing a MeV monochromator to achieve the minimum energy-dependent path length difference between cathode and sample. Thanks to the achromat design, the pulse length of the electron bunches and the energy-dependent timing jitter can be greatly reduced to the 10 fs level. The introduction of such a monochromator provides a major step forward, towards constructing a UEM with sub-nm resolution and a UED with ten-femtosecond temporal resolution. The one-to-one mapping between the electron beam parameter and the diffraction peak broadening enables a real-time nondestructive diagnosis of the beam energy spread and divergence. The tunable electric–magnetic monochromator allows the scanning of the electron beam energy with a 10 –5 precision, enabling online energy matching for the UEM, on-momentum flux maximizing for the UED and real-time energy measuring for energy-loss spectroscopy. A combination of the monochromator and a downstream chicane enables “two-color” double pulses with femtosecond duration and the tunable delay in the range of 10 to 160 fs, which can potentially provide an unprecedented femtosecond time resolution for time resolved UED.

36 MATERIALS SCIENCE↗

Waveform retrieval for ultrafast applications based on convolutional neural networks

Electric field waveforms of light carry rich information about dynamical events on a broad range of timescales. The insight that can be reached from their analysis, however, depends on the accuracy of retrieval from noisy data. In this article, we present a novel approach for waveform retrieval based on supervised deep learning. We demonstrate the performance of our model by comparison with conventional denoising approaches, including wavelet transform and Wiener filtering. The model leverages the enhanced precision obtained from the nonlinearity of deep learning. The results open a path toward an improved understanding of physical and chemical phenomena in field-resolved spectroscopy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessment of errors in analytic modeling of permanent magnet electron spectrometers for laser-plasma accelerators

Here, we assess the error in three treatments of a critical electron beam diagnostic for laser-plasma acceleration (LPA) experiments: a permanent magnet electron spectrometer. Since LPA electron spectrometers are often difficult to calibrate due to the scarcity of well-characterized, tunable electron beam sources in the appropriate energy range and the mechanical complexity of electron spectrometers, the standard of calibration is Hall probe measurements. We first compare the electron spectrometer performance between SIMION calculations and the Hall probe measurements. We find up to a 60% (<8%) error in determining the absolute energy for electrons below (above) 80 MeV when using the SIMION-modeled magnetic field vs the measured magnetic field due to SIMION overpredicting fringe field strength. The difference in spectrometer energy resolution is within ∼10% between the modeled and measured fields. We then assess a simple block model, which is commonly used. We find that the simple block model presented here sufficiently captures the predicted as-built spectrometer performance for any application provided that the user can tolerate uncertainties on absolute energy determination up to 5% and errors on energy resolution up to 1%.

Electromagnetic optics↗

Ground-state and decay properties of neutron-rich 106 Nb

The ground-state properties of neutron-rich 106 Nb and its β decay into 106 Mo have been studied using the CARIBU radioactive-ion-beam facility at Argonne National Laboratory. Niobium-106 ions were extracted from a 252 Cf fission source and mass separated before being delivered as low-energy beams to the Canadian Penning Trap, as well as the X-Array and SATURN β-decay-spectroscopy station. The measured 106 Nb ground-state mass excess of –66202.0(13) keV is consistent with a recent measurement but has three times better precision; this work also rules out the existence of a second long-lived, β-decaying state in 106 Nb above 5 keV in excitation energy. The decay half-life of 106 Nb was measured to be 1.097(21) s, which is 8% longer than the adopted value. Here, the level scheme of the decay progeny, 106 Mo, has been expanded up to ≈ 4 MeV. The distribution of decay strength and considerable population of excited states in 106 Mo of J ≥ 3 emphasizes the need to revise the adopted J π = 1 – ground-state spin-parity assignment of 106 Nb; it is more likely to be J ≥ 3.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Next Generation Ta-STJ Sensor Arrays for BSM Physics Searches

The Beryllium Electron capture in Superconducting Tunnel junctions (BeEST) experiment uses superconducting tunnel junction (STJ) sensors to search for physics beyond the standard model (BSM) with recoil spectroscopy of the 7 Be EC decay into 7 Li. A pulsed UV laser is used to calibrate the STJs throughout the experiment with ∼20 meV precision. Phase-III of the BeEST experiment revealed a systematic calibration discrepancy between STJs. We found these artifacts to be caused by resistive crosstalk and by intensity variations of the calibration laser. For phase-IV of the BeEST experiment, we have removed the crosstalk by designing the STJ array so that each pixel has its own ground wire. We now also use a more stable UV laser for calibration. The new STJ arrays were fabricated at STAR Cryoelectronics and tested at LLNL and FRIB. They have the same high energy resolution of ∼1-2~eV in the energy range of interest below 100~eV as before, and they no longer exhibit the earlier calibration artifacts. We discuss the design changes and the STJ array performance for the next phase of the BeEST experiment.

Laser Calibration↗

High-resolution Interferometer Sounder (HIS), phase 2

The High-resolution Interferometer Sounder (HIS) was successfully built, tested, and flight proven on the NASA U-2/ER-2 high altitude aircraft. The HIS demonstration has shown that, by using the technology of Fourier Transform Spectroscopy (FTS), it is possible to measure the spectrum of upwelling infrared radiance needed for temperature and humidity sounding with high spectral resolution and high radiometric precision. By resolving individual carbon dioxide lines, the retrieved temperature profiles have vertical resolutions of 1 to 2 km and RMS errors less than 1 C, about 2 to 4 times better than possible with current sounders. Implementing this capability on satellite sounders will greatly enhance the dynamical information content of temperature measurements from space. The aircraft model HIS is now a resource which should be used to support field experiments in mesoscale meteorology, to monitor trace gas concentrations and to better understand their effects on climate, to monitor the surface radiation budget and the radiative effects of clouds, and to collect data for research into retrieval techniques, especially under partially cloudy conditions.

Source record↗

A harmonized protocol to assess the single-cell performance of proton exchange membrane water electrolyzers

The harmonization of testing protocols for proton exchange membrane (PEM) electrolyzers is essential for ensuring accurate and reliable performance assessments and accelerating the development of hydrogen production technologies. This protocol provides a structured approach to PEM electrolyzer setup and testing, incorporating key considerations for test station design and single-cell characterization techniques. Polarization curves and electrochemical impedance spectroscopy (EIS) are detailed, along with best practices from academic and industry research groups to enhance data accuracy and comparability. By addressing material variability and harmonizing testing methodologies, this framework enables more precise evaluations of membrane electrode assemblies and electrolyzer components. Harmonized protocols not only streamline development efforts but also foster collaboration across institutions, ultimately supporting the commercialization of hydrogen solutions through improved stack efficiency and durability.

08 HYDROGEN↗

Microbial Vessel for Impedance Spectroscopy and Electrochemistry (Mvise): an Extensible, Interoperable Data Acquisition Platform for Liquid Culture Studies in Space Biology Research

The White House Office of Science and Technology Policy (OSTP) has declared 2023 to be the Year of Open Science following an initiative to democratize scientific knowledge. Simultaneously, new sensor technologies have broadened the experimental space available to bioastronautics research. With these open-science goals and technological advances in mind, we have designed and constructed a data acquisition platform for high-precision, real-time monitoring of liquid culture systems. The vessel rig is fitted with six Atlas Scientific probes (micro pH, electrical conductivity, dissolved oxygen, oxidation-reduction potential, liquid temperature, air CO2) and a custom optical density probe similar to the one on BioSentinel’s BioSensor payload. A custom dielectric spectroscopy probe is also planned. The structure of the vessel is resin 3-D printed on a hobbyist-level machine, reducing the production cost and iteration time by over 60% each while increasing extensibility. Data acquisition and storage is controlled with a standalone C state machine-based program running on a Raspberry Pi 3 Model B. When not running headless, an additional program automatically generates and updates plots for live data visualization. Validation of the rig as a data collection system was performed with a yeast liquid culture experiment. While the vessel rig is currently used for standalone experiments, it can also be used as the base perception unit in a self-driving laboratory (SDL). SDLs are high-throughput data collection systems that employ automation and artificial intelligence to conduct and manage routine experiments. Here, we envision an SDL driven by several vessel rigs in which an automated script compares key results, informing the design of future experiments. A vessel rig SDL would streamline many operations, including 1) strain selection for the Lunar Explorer Instrument for space biology Applications (LEIA) investigation and 2) the study of bioregenerative life support systems (BLSS). Ultimately, the datasets that can now be acquired will provide crucial information for accelerating bioastronautics application development in the era of commercial space.

Stephen Lantin↗

Nature of native atomic defects in ZrTe 5 and their impact on the low-energy electronic structure

Over the past decades, investigations of the anomalous low-energy electronic properties of ZrTe 5 have reached a wide array of conclusions. An open question is the growth method's impact on the stoichiometry of ZrTe 5 samples, especially given the very small density of states near its chemical potential. In this work, we report on high-resolution scanning tunneling microscopy and spectroscopy measurements performed on samples grown via different methods. Using density functional theory calculations, we identify the most prevalent types of atomic defects on the surface of ZrTe 5 , namely, Te vacancies and intercalated Zr atoms. Finally, we precisely quantify their density and outline their role as ionized defects in the anomalous resistivity of this material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spatial defects nanoengineering for bipolar conductivity in MoS 2

Understanding the atomistic origin of defects in two-dimensional transition metal dichalcogenides, their impact on the electronic properties, and how to control them is critical for future electronics and optoelectronics. Here, we demonstrate the integration of thermochemical scanning probe lithography (tc-SPL) with a flow-through reactive gas cell to achieve nanoscale control of defects in monolayer MoS 2 . The tc-SPL produced defects can present either p- or n-type doping on demand, depending on the used gasses, allowing the realization of field effect transistors, and p-n junctions with precise sub-μm spatial control, and a rectification ratio of over 10 4 . Doping and defects formation are elucidated by means of X-Ray photoelectron spectroscopy, scanning transmission electron microscopy, and density functional theory. We find that p-type doping in HCl/H 2 O atmosphere is related to the rearrangement of sulfur atoms, and the formation of protruding covalent S-S bonds on the surface. Alternatively, local heating MoS 2 in N 2 produces n-character.

36 MATERIALS SCIENCE↗