Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Investigation of Helical Tomotherapy for Partial-Breast Irradiation of Prone-Positioned Patients

Purpose: To investigate whether helical tomotherapy can provide conformal, uniform target-dose coverage for partial-breast irradiation (PBI) of patients positioned prone while achieving organ-at-risk sparing compliant with National Surgical Adjuvant Breast and Bowel Project (NSABP) B-39/Radiation Therapy Oncology Group (RTOG) 0413 guidelines; and to report our initial experience with the delivery of prone-breast PBI treatments using tomotherapy. Methods and Materials: For our pilot study, we generated helical tomotherapy plans upon the images of 10 prone-positioned patients previously treated using conventional techniques. We also generated plans for 4 left-breast prone-positioned PBI patients who were treated using helical tomotherapy, and recalculated the planned sinograms upon the pretreatment megavoltage computed tomographic images. Of the planning target volume (PTV), 95% was prescribed to receive 38.5 Gy, administered twice daily for 5 days. Results: For our pilot study, on average the maximum point dose to the PTV was 41.3 Gy, and 99% or more of the PTV received 90% or more of the prescribed dose. RTOG 0413 dose-volume histogram objectives were fulfilled for all organs at risk except the contralateral breast, which received a maximum point dose as high as 3.2 Gy in 1 case. For the prospective prone-positioned tomotherapy PBI plans, all objectives were met except the contralateral-breast maximum dose, which was 3.7 Gy on average. Dose calculation using the planned sinogram upon the pretreatment megavoltage computed tomographic images indicated consistency with the planned dose distributions. Conclusions: Helical tomotherapy can provide conformal and uniform target-dose coverage simultaneous with adequate sparing of critical structures; in this study only the contralateral breast dose exceeded RTOG 0413 guidelines. Dosimetric results for our 4 prospective patient cases were consistent with those for our 10-case pilot study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toward Submillimeter Accuracy in the Management of Intrafraction Motion: The Integration of Real-Time Internal Position Monitoring and Multileaf Collimator Target Tracking

Purpose: We report on an integrated system for real-time adaptive radiation delivery to moving tumors. The system combines two promising technologies-three-dimensional internal position monitoring using implanted electromagnetically excitable transponders and corresponding real-time beam adaptation using a dynamic multileaf collimator (DMLC). Methods and Materials: In a multi-institutional academic and industrial collaboration, a research version of the Calypso position monitoring system was integrated with a DMLC-based four-dimensional intensity-modulated radiotherapy delivery system using a Varian 120-leaf multileaf collimator (MLC). Two important determinants of system performance-latency (i.e., elapsed time between target motion and MLC response) and geometric accuracy-were investigated. Latency was quantified by acquiring continuous megavoltage X-ray images of a moving phantom (with embedded transponders) that was tracked in real time by a circular MLC field. The latency value was input into a motion prediction algorithm within the DMLC tracking system. Geometric accuracy was calculated as the root-mean-square positional error between the target and the centroid of the MLC aperture for patient-derived three-dimensional motion trajectories comprising two lung tumor traces and one prostate trace. Results: System latency was determined to be approximately 220 milliseconds. Tracking accuracy was observed to be sub-2 mm for the respiratory motion traces and sub-1 mm for prostate motion. Conclusion: We have developed and characterized a research version of a novel four-dimensional delivery system that integrates nonionizing radiation-based internal position monitoring and accurate real-time DMLC-based beam adaptation. This system represents a significant step toward achieving the eventual goal of geometrically ideal dose delivery to moving tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement of Interfraction Variations in Position and Size of Target Volumes in Stereotactic Body Radiotherapy for Lung Cancer

Purpose: To investigate the interfraction variations in volume, motion range, and position of the gross tumor volume (GTV) in hypofractionated stereotactic body radiotherapy (SBRT) for lung cancer using four-dimensional computed tomography. Methods and Materials: Four-dimensional computed tomography scans were acquired for 8 patients once at treatment planning and twice during the SBRT period using a stereotactic body frame. The image registration was performed to correct setup errors for clinical four-dimensional computed tomography. The interfraction variations in volume, motion range, and position of GTV were computed at end-inhalation (EI) and end-exhalation (EE). Results: The random variations in the GTV were 0.59 cm{sup 3} at EI and 0.53 cm{sup 3} at EE, and the systematic variations were 3.04 cm{sup 3} at EI and 3.21 cm{sup 3} at EE. No significant variations in GTV were found during the SBRT sessions (p = .301 at EI and p = .081 at EE). The random variations in GTV motion range for the upper lobe in the craniocaudal direction were within 1.0 mm and for the lower lobe was 3.4 mm. The interfraction variations in the GTV centroid position in the anteroposterior and craniocaudal directions were mostly larger than in the right-left direction; however, no significant displacement was observed among the sessions in any direction. Conclusion: For patients undergoing hypofractionated SBRT, interfraction variations in GTV, motion range, and position mainly remained small. An additional approach is needed to assess the margin size.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of Pancreatic Tumor Motion Using Cine MRI: Surrogates for Tumor Position Should Be Used With Caution

Purpose: Our current understanding of intrafraction pancreatic tumor motion due to respiration is limited. In this study, we characterized pancreatic tumor motion and evaluated the application of several radiotherapy motion management strategies. Methods and Materials: Seventeen patients with unresectable pancreatic cancer were enrolled in a prospective internal review board-approved study and imaged during shallow free-breathing using cine MRI on a 3T scanner. Tumor borders were agreed on by a radiation oncologist and an abdominal MRI radiologist. Tumor motion and correlation with the potential surrogates of the diaphragm and abdominal wall were assessed. These data were also used to evaluate planning target volume margin construction, respiratory gating, and four-dimensional treatment planning for pancreatic tumors. Results: Tumor borders moved much more than expected. To provide 99% geometric coverage, margins of 20 mm inferiorly, 10 mm anteriorly, 7 mm superiorly, and 4 mm posteriorly are required. Tumor position correlated poorly with diaphragm and abdominal wall position, with patient-level Pearson correlation coefficients of -0.18-0.43. Sensitivity and specificity of gating with these surrogates was also poor, at 53%-68%, with overall error of 35%-38%, suggesting that the tumor may be underdosed and normal tissues overdosed. Conclusions: Motion of pancreatic tumor borders is highly variable between patients and larger than expected. There is substantial deformation with breathing, and tumor border position does not correlate well with abdominal wall or diaphragmatic position. Current motion management strategies may not account fully for tumor motion and should be used with caution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Does Lymphovascular Invasion Predict Regional Nodal Failure in Breast Cancer Patients With Zero to Three Positive Lymph Nodes Treated With Conserving Surgery and Radiotherapy? Implications for Regional Radiation

Purpose: To examine the relationship between lymphovascular invasion (LVI) and regional nodal failure (RNF) in breast cancer patients with zero to three positive nodes treated with breast-conservation therapy (BCT). Methods and Materials: The records of 1,257 breast cancer patients with zero to three positive lymph nodes were reviewed. All patients were treated with BCT at Massachusetts General Hospital from 1980 to December 2003. Lymphovascular invasion was diagnosed by hematoxylin and eosin-stained sections and in some cases supported by immunohistochemical stains. Regional nodal failure was defined as recurrence in the ipsilateral supraclavicular, axillary, or internal mammary lymph nodes. Regional nodal failure was diagnosed by clinical and/or radiologic examination. Results: The median follow-up was 8 years (range, 0.1-21 years). Lymphovascular invasion was present in 211 patients (17%). In univariate analysis, patients with LVI had a higher rate of RNF (3.32% vs. 1.15%; p = 0.02). In multivariate analysis, only tumor size, grade, and local failure were significant predictors of RNF (p = 0.049, 0.013, and 0.0001, respectively), whereas LVI did not show a significant relationship with RNF (hazard ratio = 2.07; 95% CI, 0.8-5.5; p = 0.143). The presence of LVI in the T2/3 population did not increase the risk of RNF over that for those with no LVI (p = 0.15). In addition, patients with Grade 3 tumors and positive LVI did not have a higher risk of RNF than those without LVI (p = 0.96). Conclusion: These results suggest that LVI can not be used as a sole indicator for regional nodal irradiation in breast cancer patients with zero to three positive lymph nodes treated with BCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Matched Cohort Analysis of Outcomes of Definitive Radiotherapy for Prostate Cancer in Human Immunodeficiency Virus-Positive Patients

Purpose: To compare the biochemical outcome and toxicity scores of men with human immunodeficiency virus (HIV) and prostate cancer with a matched control population with negative or unknown HIV status when treated with external-beam radiotherapy (EBRT). Methods and Materials: A single-institution database of men with prostate cancer treated with EBRT from 1999 to 2009 was reviewed. Thirteen men with HIV were identified and matched to 2 control patients according to age, race, T stage, prostate-specific antigen level, Gleason score, RT dose, intensity-modulated RT vs. three-dimensional conformal RT, and whole-pelvis vs. prostate-only RT, for a total of 39 cases. The median follow-up time was 39 months (range, 3-110 months). Results: The 4-year biochemical failure (BF)-free survival rate was 87% in the HIV-positive group vs. 89% in the controls (p = 0.94). Pre- and post-RT viral loads were found to be predictive of BF (p = 0.04 and p = 0.04, respectively). No men with HIV died, whereas 2 in the control group died of causes unrelated to prostate cancer. Acute and chronic genitourinary and gastrointestinal toxicity were less in the HIV-positive patients than in controls (p < 0.001, p < 0.001, p = 0.003, and p < 0.001, respectively). The HIV-positive men experienced an average decline in CD4 count of 193 cells/mm{sup 3}. Conclusions: Our findings suggest that men with HIV treated with EBRT have a similar risk of BF; however, high viral loads may contribute to an increased risk. This analysis supports that HIV-positive men with prostate cancer can be treated with definitive EBRT with similar disease control and toxicity outcomes as in the general population.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Impact of Definitive Local Therapy for Lymph Node-Positive Prostate Cancer: A Population-Based Study

Purpose: To evaluate the survival outcomes for patients with lymph node-positive, nonmetastatic prostate cancer undergoing definitive local therapy (radical prostatectomy [RP], external beam radiation therapy [EBRT], or both) versus no local therapy (NLT) in the US population in the modern prostate specific antigen (PSA) era. Methods and Materials: The Surveillance, Epidemiology, and End Results database was queried for patients with T1-4N1M0 prostate cancer diagnosed from 1995 through 2005. To allow comparisons of equivalent datasets, patients were analyzed in separate clinical (cN+) and pathologically confirmed (pN+) lymph node-positive cohorts. Kaplan-Meier overall survival (OS) and prostate cancer-specific survival (PCSS) estimates were generated, with accompanying univariate log-rank and multivariate Cox proportional hazards comparisons. Results: A total of 796 cN+ and 2991 pN+ patients were evaluable. Among cN+ patients, 43% underwent EBRT and 57% had NLT. Outcomes for cN+ patients favored EBRT, with 10-year OS rates of 45% versus 29% (P<.001) and PCSS rates of 67% versus 53% (P<.001). Among pN+ patients, 78% underwent local therapy (RP 57%, EBRT 10%, or both 11%) and 22% had NLT. Outcomes for pN+ also favored local therapy, with 10-year OS rates of 65% versus 42% (P<.001) and PCSS rates of 78% versus 56% (P<.001). On multivariate analysis, local therapy in both the cN+ and pN+ cohorts remained independently associated with improved OS and PCSS (all P<.001). Local therapy was associated with favorable hazard ratios across subgroups, including patients aged ≥70 years and those with multiple positive lymph nodes. Among pN+ patients, no significant differences in survival were observed between RP versus EBRT and RP with or without adjuvant EBRT. Conclusions: In this large, population-based cohort, definitive local therapy was associated with significantly improved survival in patients with lymph node-positive prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Extended Field Intensity Modulated Radiation Therapy With Concomitant Boost for Lymph Node–Positive Cervical Cancer: Analysis of Regional Control and Recurrence Patterns in the Positron Emission Tomography/Computed Tomography Era

Purpose: Positron emission tomography/computed tomography (PET/CT) is commonly used for nodal staging in locally advanced cervical cancer; however the false negative rate for para-aortic disease are 20% to 25% in PET-positive pelvic nodal disease. Unless surgically staged, pelvis-only treatment may undertreat para-aortic disease. We have treated patients with PET-positive nodes with extended field intensity modulated radiation therapy (IMRT) to address the para-aortic region prophylactically with concomitant boost to involved nodes. The purpose of this study was to assess regional control rates and recurrence patterns. Methods and Materials: Sixty-one patients with cervical cancer (stage IBI-IVA) diagnosed from 2003 to 2012 with PET-avid pelvic nodes treated with extended field IMRT (45 Gy in 25 fractions with concomitant boost to involved nodes to a median of 55 Gy in 25 fractions) with concurrent cisplatin and brachytherapy were retrospectively analyzed. The nodal location was pelvis-only in 41 patients (67%) and pelvis + para-aortic in 20 patients (33%). There were a total of 179 nodes, with a median number of positive nodes of 2 (range, 1-16 nodes) per patient and a median nodal size of 1.8 cm (range, 0.7-4.5 cm). Response was assessed by PET/CT at 12 to 16 weeks. Results: Complete clinical and imaging response at the first follow-up visit was seen in 77% of patients. At a mean follow-up time of 29 months (range, 3-116 months), 8 patients experienced recurrence. The sites of persistent/recurrent disease were as follows: cervix 10 (16.3%), regional nodes 3 (4.9%), and distant 14 (23%). The rate of para-aortic failure in patients with pelvic-only nodes was 2.5%. There were no significant differences in recurrence patterns by the number/location of nodes, largest node size, or maximum node standardized uptake value. The rate of late grade 3+ adverse events was 4%. Conclusions: Extended field IMRT was well tolerated and resulted in low regional recurrence in node-positive cervical cancer. The dose of 55 Gy in 25 fractions was effective in eradicating disease in involved nodes, with acceptable late adverse events. Distant metastasis is the predominant mode of failure, and the OUTBACK trial may challenge the presented paradigms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Outcome for Patients With Pathologic Node-Positive Prostate Cancer Treated With Intensity Modulated Radiation Therapy and Androgen Deprivation Therapy: A Case-Matched Analysis of pN1 and pN0 Patients

Purpose: Improved outcome is reported after surgery or external beam radiation therapy (EBRT) plus androgen deprivation therapy (ADT) for patients with lymph node (LN) positive (N1) prostate cancer (PC). Surgical series have shown that pathologic (p)N1 PC does not behave the same in all patients. The aim of this study was to perform a matched-case analysis to compare the outcome of pN1 and pN0 PC after high-dose EBRT plus ADT. Methods and Materials: Radiation therapy up to 80 Gy was delivered to the prostate with a minimal dose of 45 Gy to the pelvis for pN1 patients. After matching, Kaplan-Meier statistics were used to compare the 5-year biochemical and clinical relapse-free survival (bRFS and cRFS), prostate cancer–specific survival (PCSS), and overall survival (OS). Acute and late rectal and urinary toxicity was evaluated. Results: Sixty-nine pN1 PC patients were matched 1:1 with pN0 PC patients. The median follow-up time was 60 months. The 5-year bRFS and cRFS for pN1 versus pN0 PC patients were 65% ± 7% versus 79% ± 5% (P=.08) and 70% ± 6% versus 83% ± 5% (P=.04) respectively. No significant difference was found in bRFS or cRFS rates between low volume pN1 (≤2 positive LNs) and pN0 patients. The 5-year PCSS and OS were comparable between pN1 and pN0 PC patients: PCSS: 92% ± 4% versus 93% ± 3% (P=.66); OS: 82% ± 5% versus 80% ± 5% (P=.58). Severe toxicity was rare for both groups, although pN1 patients experienced significantly more acute grade 2 rectal toxicity. Conclusion: Primary EBRT plus 2 to 3 years of ADT is a legitimate treatment option for pN1 PC patients, especially those with ≤2 positive LNs, and this with bRFS and cRFS rates comparable to those in pN0 PC patients. For pN1 PC patients with >2 positive LNs, bRFS and cRFS are worse than in pN0 patients, but even in this subgroup, long-term disease control is obtained.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Favorable Local Control From Consolidative Radiation Therapy in High-Risk Neuroblastoma Despite Gross Residual Disease, Positive Margins, or Nodal Involvement

Purpose: To report the influence of radiation therapy (RT) dose and surgical pathology variables on disease control and overall survival (OS) in patients treated for high-risk neuroblastoma at a single institution. Methods and Materials: We conducted a retrospective study of 67 high-risk neuroblastoma patients who received RT as part of definitive management from January 2003 until May 2014. Results: At a median follow-up of 4.5 years, 26 patients (38.8%) failed distantly; 4 of these patients also failed locally. One patient progressed locally without distant failure. Local control was 92.5%, and total disease control was 59.5%. No benefit was demonstrated for RT doses over 21.6 Gy with respect to local relapse–free survival (P=.55), disease-free survival (P=.22), or OS (P=.72). With respect to local relapse–free survival, disease-free survival, and OS, no disadvantage was seen for positive lymph nodes on surgical pathology, positive surgical margins, or gross residual disease. Of the patients with gross residual disease, 75% (6 of 8) went on to have no evidence of disease at time of last follow-up, and the 2 patients who failed did so distantly. Conclusions: Patients with high-risk neuroblastoma in this series maintained excellent local control, with no benefit demonstrated for radiation doses over 21.6 Gy, and no disadvantage demonstrated for gross residual disease after surgery, positive surgical margins, or pathologic lymph node positivity. Though the limitations of a retrospective review for an uncommon disease must be kept in mind, with small numbers in some of the subgroups, it seems that dose escalation should be considered only in exceptional circumstances.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postmastectomy Radiation Therapy Is Associated With Improved Survival in Node-Positive Male Breast Cancer: A Population Analysis

Purpose: Because of its rarity, there are no randomized trials investigating postmastectomy radiation therapy (PMRT) in male breast cancer. This study retrospectively examines the impact of PMRT in male breast cancer patients in the National Cancer Institute's Surveillance, Epidemiology, and End Results (SEER) database. Methods and Materials: The SEER database 8.3.2 was queried for men ages 20+ with a diagnosis of localized or regional nonmetastatic invasive ductal/lobular carcinoma from 1998 to 2013. Included patients were treated by modified radical mastectomy (MRM), with or without adjuvant external beam radiation. Univariate and multivariate analyses evaluated predictors for PMRT use after MRM. Kaplan-Meier overall survival (OS) curves of the entire cohort and a case-matched cohort were calculated and compared by the log-rank test. Cox regression was used for multivariate survival analyses. Results: A total of 1933 patients were included in the unmatched cohort. There was no difference in 5-year OS between those who received PMRT and those who did not (78% vs 77%, respectively, P=.371); however, in the case-matched analysis, PMRT was associated with improved OS at 5 years (83% vs 54%, P<.001). On subset analysis of the unmatched cohort, PMRT was associated with improved OS in men with 1 to 3 positive nodes (5-year OS 79% vs 72% P=.05) and those with 4+ positive nodes (5-year OS 73% vs 53% P<.001). On multivariate analysis of the unmatched cohort, independent predictors for improved OS were use of PMRT: HR=0.551 (0.412-0.737) and estrogen receptor–positive disease: HR=0.577 (0.339-0.983). Predictors for a survival detriment were higher grade 3/4: HR=1.825 (1.105-3.015), larger tumor T2: HR=1.783 (1.357-2.342), T3/T4: HR=2.683 (1.809-3.978), higher N-stage: N1 HR=1.574 (1.184-2.091), N2/N3: HR=2.328 (1.684-3.218), black race: HR=1.689 (1.222-2.336), and older age 81+: HR=4.164 (1.497-11.582). Conclusions: There may be a survival benefit with the addition of PMRT for male breast cancer with node-positive disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A composite position independent monitor of reactor fuel irradiation using Pu, Cs, and Ba isotope ratios

When post-irradiation materials from the nuclear fuel cycle are released to the environment, certain isotopes of actinides and fission products carry signatures of irradiation history that can potentially aid a nuclear forensic investigation into the material's provenance. In this study, combinations of Pu, Cs, and Ba isotope ratios that produce position (in the reactor core) independent monitors of irradiation history in spent light water reactor fuel are identified and explored. These position independent monitors (PIMs) are modeled for various irradiation scenarios using automated depletion codes as well as ordinary differential equation solutions to approximate nuclear physics models. Experimental validation was performed using irradiated low enriched uranium oxide fuel from a light water reactor, which was sampled at 8 axial positions from a single rod. Plutonium, barium and cesium were chemically separated and isotope ratio measurements of the separated solutions were made by quadrupole and multi-collector inductively coupled mass spectrometry (Cs and Pu, respectively) and thermal ionization mass spectrometry (Ba). The effect of axial variations in neutron fluence and energy spectrum are evident in the measured isotope ratios. Furthermore, two versions of a combined Pu and Cs based PIM are developed. A linear PIM model, which can be used to solve for irradiation time is found to work well for natural U fuel with <10% 240 Pu and known or short cooling times. A non-linear PIM model, which cannot be solved explicitly for irradiation time without additional information, can nonetheless still group samples by irradiation history, including high burnup LEU fuel with unknown cooling time. 137 Ba/ 138 Ba is also observed to act as a position independent monitor; it is nearly single valued across the sampled fuel rod, indicating that samples sharing an irradiation history (same irradiation time and cooling time) in a reactor despite experiencing different neutron fluxes will have a common 137 Ba/ 138 Ba ratio. Modeling of this Ba PIM shows it increases monotonically with irradiation and cooling time, and a confirmatory first order analytical solution is also presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Line positions and intensities of the phosphine (PH 3 ) Pentad near 4.5μm

In order to improve the spectroscopic database for remote sensing of the giant planets, line positions and intensities are determined for the five bands (2ν 2 , ν 2 + ν 4 , 2ν 4 , ν 1 and ν 3 ) that comprise the Pentad of PH 3 between 1950 and 2450 cm -1 . Knowledge of PH 3 spectral line parameters in this region is important for the exploration of dynamics and chemistry on Saturn, (using existing Cassini/VIMS observations) and future near-IR data of Jupiter from Juno and ESA’s Jupiter Icy Moons Explorer (JUICE). For this study, spectra of pure PH 3 from two Fourier transform spectrometers were obtained: (a) five high-resolution (0.00223 cm -1 ), high signal-to-noise (~1800) spectra recorded at room temperature (298.2 K) with the Bruker IFS 125HR Fourier transform spectrometer (FTS) at the Pacific Northwest National Laboratory (PNNL), Richland, Washington and (b) four high-resolution (at 0.0115 cm -1 resolution), high signal-to-noise (~700) spectra recorded at room temperature in the region 1800–5200 cm -1 using the McMath-Pierce Fourier transform spectrometer located at the National Solar Observatory (NSO) on Kitt Peak. Individual line parameters above 2150 cm -1 were retrieved by simultaneous multispectrum fittings of all five Bruker spectra, while retrievals with the four Kitt Peak spectra were done in the 1938–2168 cm -1 range spectrum by spectrum and averaged. In all, positions and intensities were obtained for more than 4400 lines. These included 53 A+A- split pairs of transitions (arising due to vibration–rotation interactions (Coriolis-type interaction) between the ν 3 and ν 1 fundamental bands) for K" = 3, 6, and 9. Over 3400 positions and 1750 intensities of these lines were ultimately identified as relatively unblended and modeled up to J = 14 and K = 12 with rms values of 0.00133 cm -1 and 7.7%, respectively. The PH 3 line parameters (observed positions and measured intensities with known quantum assignments) and Hamiltonian constants are reported. Finally, comparisons with other recent studies are discussed.

Environmental Molecular Sciences Laboratory↗

Effect of intrafractional prostate motion on simultaneous boost intensity-modulated radiotherapy to the prostate: A simulation study based on intrafractional motion in the prone position

Although the prostate displacement of patients in the prone position is affected by respiration-induced motion, the effect of intrafractional prostate motion in the prone position during “simultaneous integrated boost intensity-modulated radiotherapy” (SIB-IMRT) is unclear. The purpose of this study was to evaluate the dosimetric effects of intrafractional motion on SIB-IMRT to a dominant intraprostatic lesion (IPL) using measured motion data of patients in a prone position, fixed with a thermoplastic shell. We obtained 2 orthogonal x-ray fluoroscopic images at the same moment every 0.2 seconds for 30 seconds before and after treatment, once weekly, from 7 patients with localized prostate cancer with detectable prostatic calcification. Prostate displacements in the left-right (LR), anteroposterior (AP), and superoinferior (SI) directions were calculated using the prostatic calcification as a fiducial marker. We defined the displacement between pretreatment and posttreatment as baseline drift (BD). An SIB-IMRT plan was generated in which each IPL + 3 mm received a dose of 94.5 Gy, whereas the remainder of the prostate + 7 mm received a dose of 75.6 Gy in 9 fields. A simulated plan of dose blurring was generated by the convolution of isocenter-shifted plans using measured motion data in 30 seconds and motion in 30 seconds + distance between pretreatment and posttreatment position (BD) for each of the 7 patients. The motion in 30 seconds mainly reflected respiration-induced motion. The mean displacements of BD were 1.4 mm (− 3.1 to 8.2 mm), − 2.2 mm (− 9.1 to 1.5 mm), and − 0.3 mm (− 5.0 to 1.8 mm) in the AP, SI, and LR directions, respectively. The differences in the target coverage with V{sub 90%} of the IPL and V{sub 100%} of the prostate between the simulated plan and original plan were − 3.9% to − 0.3% and − 0.6% to 1.1% for respiration-induced motion and 3.1% to − 67.8% and 3.6% to − 13.3% for BD with respiration-induced motion, respectively. The large motion of BD resulted in an inadequate coverage by the prescribed dose of the SIB-IMRT to the IPL. A 7-mm margin is recommended when real-time tracking techniques are not applied. The effect of respiration-induced motion was small, so long as a 3-mm margin was added.

61 RADIATION PROTECTION AND DOSIMETRY↗

Interaction position, time, and energy resolution in organic scintillator bars with dual-ended readout

We report on the position, timing, and energy resolution of a range of plastic scintillator bars and reflector treatments using dual-ended silicon photomultiplier readout. These measurements are motivated by the upcoming construction of an optically segmented single-volume neutron scatter camera, in which neutron elastic scattering off of hydrogen is used to kinematically reconstruct the location and energy of a neutron-emitting source. For this application, interaction position resolutions of about 10 mm and timing resolutions of about 1 ns are necessary to achieve the desired efficiency for fission-energy neutrons. The results presented here indicate that this is achievable with an array of 5 x 5 x 190 mm 3 bars of EJ-204 scintillator wrapped in Teflon tape, read out with SensL’s J-series 6 x 6 mm 2 silicon photomultipliers. With two independent setups, we also explore the systematic variability of the position resolution, and show that, in general, using the difference in the pulse arrival time at the two ends is less susceptible to systematic variation than using the log ratio of the charge amplitude of the two ends. Finally, we measure a bias in the absolute time of interactions as a function of position along the bar: the measured interaction time for events at the center of the bar is 100 ps later than interactions near the SiPM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applications of principal component analysis for energy reconstruction in position-sensitive semiconductor detectors

We report semiconductor detectors with pixelated anodes offer a desirable combination of position sensitivity and energy resolution that are suitable for numerous applications in gamma-ray detection and imaging. Pixelization of electrodes also entails a non-uniform amplitude response as a function of gamma-ray interaction position. Energy calibrations as a function of interaction position improve energy resolution, but systematic errors in the energy reconstruction process persist and limit energy resolution at fixed electronic noise. Digitization of signals induced on collecting and adjacent electrodes offers rich information about gamma-ray interactions and their charge drift and collection as a function of time. Despite the abundance of signals for each interaction, human intuition and rule-based approaches fail to utilize the entire set of observed signals to mitigate the sources of systematic error. In order to maximize the utility of digitized signals and improve energy resolution, principal component analysis is applied towards digitized signals observed in semiconductor detectors with pixelated anodes. Principal components identified in the process form the basis for position-specific energy corrections. By leveraging this additional information encoded within digitized signals, energy resolution improves by factors between 10 and 15% with respect to full-width at half and tenth maximum values. The feature that accounts for the maximum amount of explained variance between interactions in any given pixel correlates strongly with the depth of interaction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pseudomonas aeruginosa Adhesion and Biofilm Formation on Poly(l-lysine)-Tethered Hydrogels: Synergistic Effect of Substrate Stiffness and Positive Charge Density

Infections associated with antibacterial-resistant Pseudomonas aeruginosa (P. aeruginosa) are the major cause of morbidity and mortality of patients, presenting one of the greatest therapeutic challenges for treatment of community-acquired and nosocomial infections. To develop antimicrobial hydrogel coatings to control the adhesion and subsequent biofilm formation of P. aeruginosa, we have used photo-cross-linked poly(ethylene glycol) diacrylate (PEGDA) hydrogels with varied cross-linking densities and covalently grafted poly(l-lysine) (PLL) at different weight compositions (ϕ PLL ). Both surface stiffness and positive charge density of the hydrogels were efficiently tuned over a broad range to investigate their effects on two main strains of P. aeruginosa, PA01 and PA14. We found that both number and viability of attached cells were positively correlated with the hydrogel stiffness, leading to thicker and larger coverage of cell colonies at 72 h postseeding on the stiffer substrates. The dependence of both PA01 and PA14 strains on ϕ PLL , however, was nonmonotonic. Positive charges from dissociated amine groups in the grafted PLL chains significantly promoted initial adhesion and proliferation of both strains at low ϕ PLL and developed into the thickest biofilms on the stiffest hydrogels grafted with ϕ PLL of 1–2%. Nevertheless, on the softest hydrogels grafted with PLL at high ϕ PLL of 7–10%, the bacteria no longer attached or survived. These results not only improved our fundamental understanding of bacteria-material interactions but also provided a series of PLL-grafted PEGDA hydrogels with controlled stiffness and positive charge density as ideal surface coating materials to prevent bacterial infections.

bacteria↗

The Importance of Accounting for Landscape Position When Investigating Grasslands: A Multidisciplinary Characterisation of a California Coastal Grassland

Abstract Grasslands are one of the most common land‐cover types, providing important ecosystem services globally, yet few studies have examined grassland critical‐zone functioning throughout hillslopes. This study characterised a coastal grassland over a small hillslope at Point Reyes National Seashore, California, using multidisciplinary techniques, combining remotely‐sensed, geophysical, plant, and soil measurements. Clustering techniques delineated the study area into four landscape zones, up‐, mid‐, and down‐slope, and a bordering riparian ecotone, which had distinct environmental properties that varied spatially across the site, with depth, and time. Soil moisture increased with depth and down slope towards a bordering riparian zone, and co‐varied with soil CO 2 flux rates both spatially and temporally. This highlighted three distinct controls of soil moisture on soil respiration: CO 2 fluxes were inhibited by high moisture content in the down‐slope during the wet winter months, and converged across landscape positions in the dry summer months, while also displaying post‐rain pulses. The normalised difference vegetation index (NDVI) ranged from 0.32 (September)–0.80 (April) and correlated positively with soil moisture and aboveground biomass, moving down slope. Yet, NDVI, aboveground biomass, and soil moisture were not correlated to soil organic carbon (SOC) content (0.4%–4.5%), which was highest in the mid‐slope. The SOC content may instead be linked to shifts in dominant grassland species and their rhizosphere properties with landscape position. This multidisciplinary characterisation highlighted significant heterogeneity in grassland properties with landscape position, and demonstrated an approach that could be used to characterise other critical‐zone environments on hillslopes.

54 ENVIRONMENTAL SCIENCES↗