High Inlet Temperature Combustor for Direct-Fired Supercritical Oxy-Combustion
It is envisioned that supercritical CO 2 (sCO 2 ) electric power plant efficiencies can exceed 52% with 99% carbon capture using direct-fired oxy-combustion. Such efficiencies would be competitive with Natural Gas Combined Cycles (NGCC) and operate with nearly zero carbon emissions. To achieve high plant efficiencies, turbine inlet conditions must approach 1,200 °C at 250 bar. Such conditions, while desirable from a systems perspective, exceed the current state of the art in turbine design and materials qualification. The team of Southwest Research Institute ® (SwRI ® ), Georgia Institute of Technology (Georgia Tech), Spectral Energies, LLC (Spectral), GE Global Research (GE-GRC), and the University of Central Florida (UCF) sought to demonstrate an intermediate step toward these high efficiency plants with the development of a 1 MWth, subscale direct-fired oxy-fuel combustor. The efforts focused largely on the development of an auto-ignition based combustion system capable of providing the targeted 1200 °C and the pilot-scale plant to operate the combustor. While the project was stopped short of the commissioning and demonstration work, the advances made in this effort will reduce risks associated with chemical kinetics, thermal management, water separation, flue gas cleanup, materials selection, and corrosion in future demonstration efforts for the direct-fired oxy-fuel combustion cycles. The following report documents the design, analysis, and installation efforts completed during the project periods of performance.