Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Particle characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Examining the Ice Nucleating Particles from Southern Great Plains Part II (ExINP-SGP). Field Campaign Report

Knowledge of airborne particulate matter (PM), especially the particles that have supermicron diameters, is key for understanding ice-nucleating particles (INPs). Supported by the Atmospheric Radiation Measurement (ARM) user facility, recent INP measurements at the Southern Great Plains observatory (SGP; 36'' 36' 18→ N, 97° 29' 6'' W) during multiple campaigns, such as SINCE-2014 (DeMott et al. 2015), Examining the Ice-Nucleating Particles from SGP (ExINP-2019; Hiranuma and Vepuri 2020), and Aerosol-Ice Formation Closure Pilot Study (AEROICESTUDY; Knopf et al. 2021a), strongly suggested the contribution of supermicron aerosol particles to observed INP abundance at SGP. However, verification of this hypothesis was hampered since additional offline laboratory analyses require sufficient amounts of collected airborne PM, which was lacking. Therefore, the principal investigators (PIs) conducted a field campaign, named ExINP-SGP II, to collect airborne PM at SGP for complementary laboratory characterization of the particles’ physicochemical properties (including ice nucleation properties). We used a passive particle sampler, which is a 4’ x 4’ x 2” (L x W x D) aluminum pan inside the 12”-high wooden windshield wall at the rooftop deck of the ARM Aerosol Observing System (AOS) trailer to collect dry PM deposits from January to April 2021. Figure 1 shows images of our experimental setup at the site. Additionally, we also collected surface soil near the ARM AOS trailer on 20 November 2020 (Figure 1b) to examine the ground soil dust particles (< 63 µm sieved) for their propensities to initiate immersion freezing compared to collected ambient PM. Surface soil and airborne samples were stored in the chemically inert container separately and kept in a dry, cool place until analyzed.

54 ENVIRONMENTAL SCIENCES↗

Low voltage scanning electron microscopy of interplanetary dust particles

The resolution of available low-voltage SEM (LVSEM) models used in the characterization of interplanetary dust particles (IDPs) is limited by a number of factors including energy spread in the electron source, beam brightness, scanning electron detector geometry, and various lens aberrations. This paper describes an improved model of LVSEM which offers an increased resolution at low voltage. The improvements include a cold cathode FE source which has an extremely low inherent energy spread and high brightness, a second condenser lens to converge the beam and maintain an optimum aperture half-angle, and a detector optimized for low-voltage scanning-electron collection. To reduce lens aberrations, the specimen is immersed in the objective lens field. The features of several IDP samples observed using the images obtained with this LVSEM model are described.

Blake, D. F.↗

Structural analysis of platelet fragments and extracellular vesicles produced by apheresis platelets during storage

Platelets (PLTs) for transfusion can be stored for up to 7 days at room temperature (RT). The quality of apheresis PLTs decreases over storage time, which affects PLT hemostatic functions. Here, we characterized the membranous particles produced by PLT storage lesion (PSLPs), including degranulated PLTs, PLT ghosts, membrane fragments, and extracellular membrane vesicles (PEVs). The PSLPs generated in apheresis platelet units were analyzed on days 1, 3, 5, and 7 of RT storage. A differential centrifugation and a sucrose density gradient were used to separate PSLP populations. PSLPs were characterized using scanning and transmission electron microscopy (EM), flow cytometry (FC), and nanoparticle tracking analysis (NTA). PSLPs have different morphologies and a broad size distribution; FC and NTA showed that the concentration of small and large PSLPs increases with storage time. The density gradient separated 3 PSLP populations: (1) degranulated PLTs, PLT ghosts, and large PLT fragments; (2) PEVs originated from PLT activation and organelles released by necrotic PLTs; and (3) PEV ghosts. Most PSLPs expressed phosphatidyl serine and induced thrombin generation in the plasma. PSLPs contained extracellular mitochondria and some had the autophagosome marker LC3. PSLPs encompass degranulated PLTs, PLT ghosts, large PLT fragments, large and dense PEVs, and low-density PEV ghosts. The activation-related PSLPs are released, particularly during early stage of storage (days 1-3), and the release of apoptosis- and necrosis-related PSLPs prevails after that. No elevation of LC3- and TOM20-positive PSLPs indicates that the increase of extracellular mitochondria during later-stage storage is not associated with PLT mitophagy.

59 BASIC BIOLOGICAL SCIENCES↗

Particle and field stress balance within a planetary magnetosphere

A technique is developed for experimentally estimating the local tensor stresses within a planetary magnetic field configuration characterized by local spacecraft measurements. Key to the technique is the determination of the shapes of field lines using the symmetry properties of the system coupled with local and instantaneous measurements of the field line inclination angles. The technique is applied here to the inner and middle Saturnian magnetosphere using data returned by the Magnetic Field Experiment on the Voyager 1 spacecraft. It is concluded that the ring current has substantial radial structure, heretofore not shown. Outside about 13 R(s) the newly derived field stresses match remarkably well the funtional variation of the centrifugal corotation stresses of the cool particle population measured previously by the Plasma Science Experiment. Inside about 13 R(s) the key structure in the derived field stresses, a prominent local maximum, matches the approximate position of an apparent strong pressure gradient in the energetic particles characterized by the Low-Energy Charged Particle detectors.

Mauk, B. H.↗

Er3+-Yb3+/Er3+-Yb3+-Li+/Er3+-Yb3+-Zn2+:Gd2O3 nanophosphors for efficient frequency upconverter and temperature sensing applications

Highlights: • The Er{sup 3+}-Yb{sup 3+}:Gd{sub 2}O{sub 3} nanophosphors infer the enhancement in UC emission intensity via incorporation of Li{sup +} and Zn{sup 2+} ions. • The average particles size of the developed nanophosphors is found to be lie in nanometer range by XRD and TEM analysis. • The maximum sensitivity ∼ 0.0116 K{sup −1} has been reported in the Er{sup 3+}-Yb{sup 3+}-Zn{sup 2+}:Gd{sub 2}O{sub 3} nanophosphors. • The colour coordinate for the developed Er{sup 3+}-Yb{sup 3+}-Zn{sup 2+}:Gd{sub 2}O{sub 3} nanophosphors lie in the greenish yellow colour region. - Abstract: Er{sup 3+}/Yb{sup 3+}/Li{sup +}/Zn{sup 2+}:Gd{sub 2}O{sub 3} nanophosphors synthesized via combustion synthesis method have been structurally and optically characterized. The average particles size of the developed nanophosphors has been found to be ∼ 25 nm by Transmission Electron Microscopy (TEM) analysis which is in good agreement with the X-rays Diffraction (XRD) results. The significant enhancement in upconversion (UC) emission intensity for green (∼ 20 and 70 times) and red (∼ 7 and 20 times) band have been observed after codoping with Li{sup +} and Zn{sup 2+} ions respectively in Er{sup 3+}-Yb{sup 3+}:Gd{sub 2}O{sub 3} system. The temperature sensing capability of the optimized nanophosphors has been studied corresponding to two thermally coupled {sup 2}H{sub 11/2} and {sup 4}S{sub 3/2} levels of the Er{sup 3+} ions. The sensitivity ∼ 0.0096 K{sup -1}, 0.00109 K{sup -1} and 0.0116 K{sup -1} have been reported in the Er{sup 3+}-Yb{sup 3+}:Gd{sub 2}O{sub 3}, Er{sup 3+}-Yb{sup 3+}- Li{sup +}:Gd{sub 2}O{sub 3} and Er{sup 3+}-Yb{sup 3+}- Zn{sup 2+}:Gd{sub 2}O{sub 3} nanophosphors respectively. The photometric characterizations of the developed nanophosphors have also been reported.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Review—Drag Coefficients of Non-Spherical and Irregularly Shaped Particles

Abstract The knowledge of simple and relatively accurate closure equations for the drag coefficients of nonspherical particles is very important for Eulerian multiphase numerical codes that require such inputs for the solution of the momentum equation. However, the existing correlations for the drag coefficients are laden with high uncertainty, which propagates in the numerical results. This review paper examines critically the state of our knowledge of the drag coefficients of nonspherical particles starting with our understanding of the “size” and “shape” of particles. Lengthscales and other parameters that have been used to characterize sizes of nonspherical particles are presented. Shape factors and shape descriptors that have been used in past correlations are also presented together with an appraisal of their applicability. Several correlations that have been developed for the determination of the drag coefficients of nonspherical particles with regular and irregular shapes are also presented together with available information on their accuracy and applicability. Based on the review of the available correlations general recommendations are offered on the use of the correlations as closure equations and inputs in computatioal fluid dynamics (CFD) codes.

Engineering↗

UAS Payload Design for In-Situ Smoke Plume Sensing

To aid in the detection of harmful aerosols and trace gases emitted in wildfires and prescribed burns, we are designing a smoke-specific payload which can be flown on the Black Swift S2™ Uncrewed Aerial System (UAS) platform. The payload will be custom and mounted within the nosecone, equipped with a trace gas sensor suite and particle spectrometer for characterization of wildfire and prescribed burn emissions. This data will aid in the improvement of HYSPLIT3 modeling to make more informed decisions regarding prescribed burns, particularly for mountain valleys in the Pacific Northwest. The trace gas suite will be composed of 8 low-cost trace gas sensors (CH4, CO2, CO, HCN, NO2, NO, O3, and Volatile Organic Compounds (VOCs)). Portable Optical Particle Spectrometer (POPS) measures particle size range between 0.14 to 3 µm, which is crucial for assessing public health impact, air quality, and visibility.

Henry Miller↗

Characterization of Three Carbon- and Nitrogen-Rich Particles from Comet 81P/WILD

Comets may sample the early solar system s complement of volatile-forming elements - including C and N - more fully and reliably than do the terrestrial planets or asteroids. Until recently, all elemental analyses of unambiguously cometary material were carried out remotely. The return of the Stardust mission makes it possible to analyze documented material from P81/Wild 2 in the laboratory Wild 2 particles fragmented when they stopped in the aerogel collectors. We have studied three fragments thought to be rich in C and N by using several techniques: FTIR to characterize organic matter; synchrotron-induced x-ray fluorescence (SXRF) to determine Fe and certain element/Fe ratios; SEM to image sample morphology and to detect semiquantitatively Mg, Al, Si, Ca, and Fe; and nuclear reaction analysis (NRA) to measure C, N, O, and Si.

Gallien, J.-P.↗

Dissolution of Intermetallic Second-Phase Particles in Zircaloy-2 in High-Temperature Steam

The stability of intermetallic second-phase particles (SPPs) in coated Zircaloy-2 was studied in 700 °C steam environments up to 20 hours. Hydrogen generated from high-temperature steam oxidation of uncoated Zr-induced δ-hydrides formation in the Zircaloy matrix. Synchrotron XRD demonstrated that longer exposure times increased hydride peak intensity and decreased intermetallic SPPs’ peak intensity. Cross-sectional SEM analysis verified the intermetallic SPPs’ volume fraction reduction. The size distribution of intermetallic SPPs was characterized and larger particles were dissolved at longer oxidation time. Finally, a correlation between the hydrogen concentration and the volume fraction of intermetallic SPPs at 700 °C steam environment was found, with the volume fraction of SPPs decreasing as hydrogen concentration increases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Preparation and Characterization of Polyaniline and Ag/ Polyaniline Composite Nanoporous Particles and Their Antimicrobial Activities

Polyaniline (PANI) and Ag/PANI nanoporous composite were prepared by an oxidative polymerization method. The oxidation process of PANI nanoparticles was occurred using (NH{sub 4}){sub 2}S{sub 2}O{sub 8} while the oxidation process of Ag/PANI nanoporous composite was occurred using AgNO{sub 3} under the effect of artificial radiation. The structural, morphological, and optical properties of the PANI and Ag/PANI nanoporous structures were studied using different characterization tools. The results confirm the formation of polycrystalline nanoporous PANI and spherical nanoporous composite of Ag/PANI particles. Antibacterial activity tests against gram-positive bacteria, Bacillus subtilis and Staphylococcus aureus, and gram-negative bacteria, Escherichia coli, and Salmonella species were carried out using different concentrations of PANI nanoparticles and Ag/PANI nanoporous composites. PANI has not antibacterial effect against all studied pathogens. In contrast, Ag/PANI nanoporous composites possessed antibacterial activity that is identified by the zone of inhibition. The inhibition zones of bacteria are in order; Salmonella species > S. aureus > B. subtilis > E. coli. The inhibition zones of all bacteria increased with increasing concentrations of Ag/PANI nanoporous composites from 200 to 400 ppm then decreased with further increasing of the dose concentrations to 600 ppm. Finally, a simplified mechanism based on the electrostatic attraction is presented to describe the antimicrobial activity of Ag/PANI nanoporous composite.

36 MATERIALS SCIENCE↗

X-Ray Computed Tomography of Apollo Drive Tube 73001 as Part of the Apollo Next Generation Sample Analysis Program

Introduction: Starting in 2019, the Apollo Next Generation Sample Analysis (ANGSA) Program has enabled consortium studies of specially curated Apollo samples that were previously unstudied (or under studied). This program was intended as a participating scientist program for these Apollo samples, as well as a preparation for upcoming lunar sample return missions (e.g., Artemis). The work began with studies of unsealed core tube 73002 [1,2] that is the upper ~35 cm of an Apollo 17 double drive tube (~70 cm total depth) collected on the landslide deposit near Lara Crater at Station 3 in the Taurus Littrow Valley. More recently the program extended to the study of a variety of frozen Apollo 17 samples [3], as well as the gas extraction [4] and dissection [5] of 73001, the lower half of the station 3 double drive tube. Sample 73001 was sealed under vacuum on the Moon in a Core Sample Vacuum Container (CSVC). In this abstract we will examine the role of X-ray Computed Tomography (XCT) during the preliminary examination process for sealed core 73001, including: (1) engineering scans to aid in understanding the gas extraction process, (2) whole-core scanning prior to opening to inform extrusion and dissection work, and (3) individual particle scanning to characterize rock fragment lithologies for follow on studies. Methodology: Sample 73001 is a 33 cm long, 4 cm diameter regolith sample collected inside a lunar drive tube (~1 mm aluminum walls). That drive tube was sealed inside a 0.5 mm thick stainless steel (SS) CSVC. XCT scans for engineering purposes were done on the Nikon XTH 320 system at Johnson Space Center using the 225 kV multi-metal reflection source at 215 kV, 179 A, and a 38.49 m voxel size. Individual >4 mm particles separated from the core during processing (then triply sealed in Teflon bags) were also scanned at JSC using the 180 kV source at 90 kV, 33 A, and a 2.98 – 10.65 m voxel size. Whole-core scans were done at the University of Texas High-Resolution X-ray Computed Tomography Facility (UTCT) on the 225 kV reflection source on the North Star Imaging cabinet XCT system. These scans included: (1) a series of 9 overlapping super-resolution scans each covering a ~4 cm length of the tube at 190 kV, 180 µA, and a 12.9 µm voxel size and (2) a lower resolution continuous helical scan of the entire core at 190 kV, 180 µA, and a 51.8 µm voxel size. Progress and Results: Before piercing and extracting the gas from sample 73001, an XCT scan of the bottom portion of the CSVC was used to confirm the location of the Teflon cap on the inner drive tube and whether there was an “air” gap between the Teflon cap and the CSVC. This was to ensure the Teflon cap (which immobilized the soil inside the drive tube) was not accidentally pierced during gas extraction. Similarly, after piercing, the bottom and top portions of the CSVC were scanned in order to capture engineering knowledge about the results of the piercing process, as well as the metal knife edge vacuum seal (SS into an In-Ag alloy). Both scans will provide constraints on future work of this type, both for the design of tools used on the lunar surface during Artemis, as well as how we open future samples of this type. An unexpected finding from these engineering scans was that the device in the drive tube that immobilizes the regolith (the keeper) was not seated in the tube properly. This meant that (1) the drive tube could not be removed from the CSVC for the trip to UTCT, and (2) the procedure for opening and extruding the drive tube had to be modified. Had either of these things not been known prior to opening the CSVC, it could have led to an inability to XCT scan the whole core at high resolution and/or potential disruption of the core stratigraphy during extrusion. At UTCT, the entire length of the core was scanned at high resolution (12.9 microns per voxel). This scan serves multiple purposes: (1) A lower resolution (and uncorrected) version of these scans stitched together was used to help inform the processors of potential pitfalls during extrusion and dissection (voids, angular fragments at the edges of the sample, etc.); and (2) the full resolution corrected data will serve as the permanent in situ record of the stratigraphy of the sample and will enable future researchers to perform a variety of analyses. All 121 >4 mm particles separated during dissection pass 1 of sample 73001 have been individually scanned. These scans clearly show the lithology of each particle while keeping the particles in pristine condition (they are individually triply bagged in Teflon within our N2 purged processing cabinets). Because of the dust adhering to particle exteriors, it would otherwise be impossible to determine lithologies in a non-contaminating way. Thus far the types of lithologies seen in sample 73001 (e.g., regolith breccias, impact-melt breccias, agglutinates, and bas-alts) are similar to those previously identified in sample 73002 [2]. By the time of the meeting, all particles from all 3 dissection passes will have been scanned and statistics on the different lithologies in 73001 compiled. References: [1] Shearer et al. (2020) 51st LPSC, abstract 1181. [2] Zeigler et al. (2020) 51st LPSC, abstract 3023. [3] Kent et al. (2022) This Volume. [4] McDonald et al. (2022) European Lunar Symposium. [5] Gross et al (2022) This volume.

Moon↗

Method for characterizing the upset response of CMOS circuits using alpha-particle sensitive test circuits

A method for predicting the SEU susceptibility of a standard-cell D-latch using an alpha-particle sensitive SRAM, SPICE critical charge simulation results, and alpha-particle interaction physics. A technique utilizing test structures to quickly and inexpensively characterize the SEU sensitivity of standard cell latches intended for use in a space environment. This bench-level approach utilizes alpha particles to induce upsets in a low LET sensitive 4-k bit test SRAM. This SRAM consists of cells that employ an offset voltage to adjust their upset sensitivity and an enlarged sensitive drain junction to enhance the cell's upset rate.

Buehler, Martin G.↗

X-Ray Computed Tomography During Preliminary Examination of Apollo Drive Tube 73001

Introduction: Starting in 2019, the Apollo Next Generation Sample Analysis (ANGSA) Program has enabled consortium studies of specially curated Apollo samples that were previously unstudied (or under studied). This began with unsealed core tube 73002 [1,2] that is the upper part of a station 3 double drive tube. More recently the pro-gram extended to the study of a variety of frozen Apollo 17 samples [3], as well as the gas extraction [4] and dis-section [5] of 73001, the lower half of the station 3 double drive tube, that was sealed under vacuum on the Moon. In this abstract we will examine the role of X-ray Computed Tomography (XCT) during the preliminary examination process for sealed core 73001, including: (1) engineering scans to aid in understanding the gas extraction process, whole-core scanning prior to opening to inform extrusion and dissection work, and (3) individual particle scanning to characterize rock fragment lithologies for follow on studies. Methodology: Sample 73001 is a 33 cm long, 4 cm diameter regolith sample collected inside a drive tube (~1 mm aluminum walls). That drive tube was sealed inside a 0.5 mm thick stainless steel (SS) Core Sample Vacuum Container (CSVC). XCT scans for engineering purposes were done on the Nikon XTH 320 system at Johnson Space Center using the 225 kV multi-metal reflection source at 215 kV, 179 A, and a 38.49 m voxel size. Individual >4 mm particles separated from the core during processing (then triply sealed in Teflon bags) were also scanned at JSC using the 180 kV source at 90 kV, 33 A, and a 2.98 – 10.65 m voxel size. Whole-core scans were done at the University of Texas High-Resolution X-ray Computed Tomography Facility (UTCT) on the 225 kV reflection source on the North Star Imaging cabinet XCT system. These scans included: (1) a series of 9 overlapping super-resolution scans each covering a ~4 cm length of the tube at 190 kV, 180 µA, and a 12.9 µm voxel size and (2) a lower resolution continuous helical scan of the entire core at 190 kV, 180 µA, and a 51.8 µm voxel size. Progress and Results: Before piercing and extracting the gas from sample 73001, an XCT scan of the bottom portion of the CSVC was used to confirm the location of the Teflon cap on the inner drive tube, to ensure it was not accidentally pierced during gas extraction. Similarly, after piercing, the bottom and top portions of the CSVC were scanned in order to capture engineering knowledge about the results of the piercing process, as well as the metal knife edge vacuum seal (SS into In-Ag alloy). Both scans will provide constraints on future work of this type, particularly for samples collected during the Artemis mission. Another finding from these "engineering" scans was that the device in the drive tube that immobilizes the regolith (the keeper) was not seated in the tube properly. This meant that (1) the drive tube could not be removed from the CSVC for the trip to UTCT, and (2) the procedure for opening and extruding the drive tube had to be modified. Had either of these things not been known prior to opening the CSVC, it could have led to an inability to XCT scan the whole core at high resolution and/or potential disruption of the core stratigraphy during extrusion. At UTCT, the entire length of the core was scanned at high resolution (12.9 microns per voxel). This scan serves multiple purposes: (1) A lower resolution (and uncorrected) version of these scans stitched together was used to help inform the processors of potential pitfalls during extrusion and dissection; and (2) the full resolution corrected data will serve as the permanent in situ record of the stratigraphy of the sample and will enable future researchers to perform a variety of analyses. So far, 92 of the 121 >4 mm particles separated during dissection pass 1 of sample 73001 have been individually scanned. These scans clearly show the lithology of each particle while keeping the particles in pristine condition. Because of the dust adhering to particle exteriors it would otherwise be impossible to determine lithologies in a non-contaminating way. Thus far the types of lithologies seen in sample 73001 (e.g., regolith breccias, impact-melt breccias, agglutinates, and basalts) are similar to those previously identified in sample 73002 [2]. By the time of the meeting, all particles from all 3 dissection passes will have been scanned and statistics on the different lithologies in 73001 compiled. References: [1] Shearer et al. (2020) 51st LPSC, abstract 1181. [2] Zeigler et al. (2020) 51st LPSC, abstract 3023. [3] Kent et al. (2022) This Volume. [4] McDonald et al. (2022) European Lunar Symposium. [5] Gross et al (2022) This volume.

Moon↗

Material Dimensionality Effects on Electron Transfer Rates Between CsPbBr 3 and CdSe Nanoparticles

Films containing mixtures of zero- or two-dimensional nanostructures (quantum dots or nanoplatelets) were prepared in order to investigate the impacts of dimensionality on electronic interactions. Electron transfer from CsPbBr 3 to CdSe was observed in all of the mixtures, regardless of particle dimensionality, and characterized via static and transient absorption and photoluminescence spectroscopies. We find that mixtures containing nanoplatelets, either as the electron donor (CsPbBr 3 ) or acceptor (CdSe), undergo charge transfer more rapidly than those containing quantum dots. These results bolster the use of one- or two-dimensional nanomaterials in the place of zero-dimensional quantum dots in the design of related optoelectronic devices such as solar cells, light-emitting diodes, and photocatalysts and further offer the prospect of fewer required hopping events to transport carriers due to the larger spatial extent of the particles.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Implications of Aerosol Physicochemical Properties Including Ice Nucleation at ARM Mega Sites for Improved Understanding of Microphysical Atmospheric Cloud Processes (Final Technical Report)

Continuous, long-term measurements of atmospheric ice-nucleating particles (INPs) that influence clouds and precipitation were conducted to investigate the abundance and variability of ground-level INPs across the world. Three field campaigns were organized by the DOE Atmospheric Radiation Measurement (ARM) program, including Examining INP from Southern Great Plains (ExINP-SGP, 2019), Examining INP from Eastern North Atlantic (ExINP-ENA, 2020 – 2021), and Examining INP from North Slope of Alaska (ExINP-NSA, 2021 – 2024). Additional small-scale supporting field experiments were performed in 2019 and 2021 to collect airborne particulate matter at SGP for complementary laboratory characterization of the particles’ physical and chemical properties [Aerosol-Ice Formation Closure Pilot Study (AEROICESTUDY), 2019; ExINP-SGP II, 2021]. In these studies, the PI’s team measured INP concentration with both real-time and laboratory measurements in a wide range of freezing temperatures ($T$ from 0 °C to about –30 °C). This project elucidated spatial variability and seasonality in the abundance of immersion mode active INPs across three ARM sites using a single instrument, a Portable Ice Nucleation Experiment (PINE) chamber version 03 (PINE-03 hereafter). Collocated aerosol and meteorological data were analyzed to assess the correlation between ambient INP abundance, air mass origin region, and meteorological variability. Our findings suggest very high freezing efficiency of INPs at the NSA site across the measured temperatures (ice nucleation active surface site density, $n_s(T)$, $\approx 2 \times 10^{8} - 10^{10}$ m -2 for from –16 to –31 °C), which is a factor of 10 – 1000 times greater efficiency as compared to that found in the previous mid-latitude INP measurements in autumn using the same instrument; surprisingly high INP abundance ($\ge 1 \text{ L}^{-1}$ at –25 °C) for the examined temperatures throughout the year that PINE-03 did not measure at other sites; and high INP concentration in spring, possibly related to arctic haze episodes.

58 GEOSCIENCES↗

Polarimetric Remote Sensing of Atmospheric Aerosols: Instruments, Methodologies, Results, and Perspectives

Polarimetry is one of the most promising types of remote sensing for improved characterization of atmospheric aerosol. Indeed, aerosol particles constitute a highly variable atmospheric component characterized by a large number of parameters describing particle sizes, morphologies (including shape and internal structure), absorption and scattering properties, amounts, horizontal and vertical distribution, etc. Reliable monitoring of all these parameters is very challenging, and therefore the aerosol effects on climate and environment are considered to be among the most uncertain factors in climate and environmental research. In this regard, observations that provide both the angular distribution of the scattered atmospheric radiation as well as its polarization state at multiple wavelengths covering the UV–SWIR spectral range carry substantial implicit information on the atmospheric composition. Therefore, high expectations in improving aerosol characterization are associated with detailed passive photopolarimetric observations. The critical need to use space-borne polarimetry for global accurate monitoring of detailed aerosol properties was first articulated in the late 1980s and early 1990s. By now, several orbital instruments have already provided polarization observations from space, and a number of advanced missions are scheduled for launch in the coming years by international and national space agencies. The first and most extensive record of polarimetric imagery was provided by POLDER-I, POLDER-II, and POLDER/PARASOL multi-angle multi-spectral polarization sensors. Polarimetric observations with the POLDER-like design intended for collecting extensive multi-angular multi-spectral measurements will be provided by several instruments, such as the MAI/TG-2, CAPI/TanSat, and DPC/GF-5 sensors recently launched by the Chinese Space Agency. Instruments such as the 3MI/MetOp-SG, MAIA, SpexOne and HARP2 on PACE, POSP, SMAC, PCF, DPC–Lidar, ScanPol and MSIP/Aerosol-UA, MAP/Copernicus CO2 Monitoring, etc. are planned to be launched by different space agencies in the coming decade. The concepts of these future instruments, their technical designs, and the accompanying algorithm development have been tested intensively and analyzed using diverse airborne prototypes. Certain polarimetric capabilities have also been implemented in such satellite sensors as GOME-2/MetOp and SGLI/GCOM-C.

Aerosols↗

Preparation for Scaling Studies of Ice-Crystal Icing at the NRC Research Altitude Test Facility

This paper describes experiments conducted at the National Research Council (NRC) of Canadas Research Altitiude Test Facility between March 26 and April 11, 2012. The tests, conducted collaboratively between NASA and NRC, focus on three key aspects in preparation for later scaling work to be conducted with a NACA 0012 airfoil model in the NRC Cascade rig: (1) cloud characterization, (2) scaling model development, and (3) ice-shape profile measurements. Regarding cloud characterization, the experiments focus on particle spectra measurements using two shadowgraphy methods, cloud uniformity via particle scattering from a laser sheet, and characterization of the SEA Multi-Element probe. Overviews of each aspect as well as detailed information on the diagnostic method are presented. Select results from the measurements and interpretation are presented which will help guide future work.

Ice formation↗

Stochastic 3D reconstruction of cracked polycrystalline NMC particles using 2D SEM data

Li-ion battery performance is strongly influenced by the 3D microstructure of its cathode particles. Cracks within these particles develop during calendaring and cycling, reducing connectivity but increasing reactive surface, making their impact on battery performance complex. Understanding these contradictory effects requires a quantitative link between particle morphology and battery performance. However, informative 3D imaging techniques are time-consuming, costly and rarely available, such that analyses often have to rely on 2D image data. This paper presents a novel stereological approach for generating virtual 3D cathode particles exhibiting crack networks that are statistically equivalent to those observed in 2D sections of experimentally measured particles. Consequently, 2D image data suffices for deriving a full 3D characterization of cracked cathodes particles. Such virtually generated 3D particles could serve as geometry input for spatially resolved electro-chemo-mechanical simulations to enhance our understanding of structure-property relationships of cathodes in Li-ion batteries.

36 MATERIALS SCIENCE↗