Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Parameter Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

High-Throughput Material Characterization using the Virtual Fields Method

Modeling material and component behavior using finite element analysis (FEA) is critical for modern engineering. One key to a credible model is having an accurate material model, with calibrated model parameters, which describes the constitutive relationship between the deformation and the resulting stress in the material. As such, identifying material model parameters is critical to accurate and predictive FEA. Traditional calibration approaches use only global data (e.g. extensometers and resultant force) and simplified geometries to find the parameters. However, the utilization of rapidly maturing full-field characterization techniques (e.g. Digital Image Correlation (DIC)) with inverse techniques (e.g. the Virtual Feilds Method (VFM)) provide a new, novel and improved method for parameter identification. This LDRD tested that idea: in particular, whether more parameters could be identified per test when using full-field data. The research described in this report successfully proves this hypothesis by comparing the VFM results with traditional calibration methods. Important products of the research include: verified VFM codes for identifying model parameters, a new look at parameter covariance in material model parameter estimation, new validation techniques to better utilize full-field measurements, and an exploration of optimized specimen design for improved data richness.

36 MATERIALS SCIENCE↗

Adjoint-based Calibration of Plasticity Model Parameters from Digital Image Correlation Data

Parameter estimation for mechanical models of plastic deformation utilized in nuclear weapons systems is a laborious process for both experimentalists and constitutive modelers and is critical to producing meaningful numerical predictions. In this work we derive an adjoint-based optimization approach for a stabilized, large-deformation J 2 plasticity model that is considerably more computationally efficient but no less accurate than current state of the art methods. Unlike most approaches to model calibration, we drive the inversion procedure with full-field deformation data that can be experimentally measured through established digital image or volume correlation techniques. We present numerical results for two and three dimensional model problems and comment on various directions of future research.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Optimum data weighting and error calibration for estimation of gravitational parameters

A new technique was developed for the weighting of data from satellite tracking systems in order to obtain an optimum least-squares solution and an error calibration for the solution parameters. Data sets from optical, electronic, and laser systems on 17 satellites in GEM-T1 Goddard Earth Model-T1 (GEM-T1) were employed toward application of this technique for gravity field parameters. Also GEM-T2 (31 satellites) was recently computed as a direct application of the method and is summarized. The method employs subset solutions of the data associated with the complete solution to agree with their error estimates. With the adjusted weights the process provides for an automatic calibration of the error estimates for the solution parameters. The data weights derived are generally much smaller than corresponding weights obtained from nominal values of observation accuracy or residuals. Independent tests show significant improvement for solutions with optimal weighting. The technique is general and may be applied to orbit parameters, station coordinates, or other parameters than the gravity model.

Lerch, Francis J.↗

MODIS On-orbit Calibration Uncertainty Assessment

MODIS has 20 reflective solar bands (RSB) and 16 thermal emissive bands (TEB). Compared to its heritage sensors, MODIS was developed with very stringent calibration uncertainty requirements. As a result, MODIS was designed and built with a set of on-board calibrators (OBC), which allow key sensor performance parameters and on-orbit calibration coefficients to be monitored and updated. In terms of its calibration traceability, MODIS RSB calibration is reflectance based using an on-board solar diffuser (SD) and the TEB calibration is radiance based using an on-board blackbody (BB). In addition to on-orbit calibration coefficients derived from its OBC, calibration parameters determined from sensor pre-launch calibration and characterization are used in both the RSB and TEB calibration and retrieval algorithms. This paper provides a brief description of MODIS calibration methodologies and an in-depth analysis of its on-orbit calibration uncertainties. Also discussed in this paper are uncertainty contributions from individual components and differences due to Terra and Aqua MODIS instrument characteristics and on-orbit performance.

Chiang, Vincent↗

MODIS Radiometric Calibration and Uncertainty Assessment

Since launch, Terra and Aqua MODIS have collected more than II and 9 years of datasets for comprehensive studies of the Earth's land, ocean, and atmospheric properties. MODIS observations are made in 36 spectral bands: 20 reflective solar bands (RSB) and 16 thermal emissive bands (TEB). Compared to its heritage sensors, MODIS was developed with very stringent calibration and uncertainty requirements. As a result, MODIS was designed and built with a set of state of the art on-board calibrators (OBC), which allow key sensor performance parameters and on-orbit calibration coefficients to be monitored and updated if necessary. In terms of its calibration traceability, MODIS RSB calibration is reflectance based using an on-board solar diffuser (SD) and the TEB calibration is radiance based using an on-board blackbody (BB). In addition to on-orbit calibration coefficients derived from its OBC, calibration parameters determined from sensor pre-launch calibration and characterization are used in both the RSB and TEB calibration and retrieval algorithms. This paper provides a brief description of MODIS calibration methodologies and discusses details of its on-orbit calibration uncertainties. It assesses uncertainty contributions from individual components and differences between Terra and Aqua MODIS due to their design characteristics and on-orbit periormance. Also discussed in this paper is the use of MODIS LIB uncertainty index CUI) product.

Xiong, Xiaoxiong↗

Half-hard copper PTW model parameters for plastic deformation calibrated to strain rates from 10 −3 -10 7 /s

This document demonstrates a calibration of the Preston-Tonks-Wallace (PTW) model of plastic deformation that fairly accurately reproduces the flow stress of half-hard copper across strain rates varying by a factor of more than ten billion. The experiments included are quasistatic compression at low rates, Split Hopkinson Pressure Bar (SHPB) compression at intermediate rates, and arrested Richtmyer-Meshkov instability (RMI) growth at high strain rates. The temperatures vary from liquid nitrogen (77 K) to around 500 K. The largest true strains obtained are approximately 0.5. It would be interesting to compare the results to copper deformation data at higher pressures and higher strains.

36 MATERIALS SCIENCE↗

SU-D-304-06: Measurement of LET in Patient-Specific Proton Therapy Treatment Fields Using Optically Stimulated Luminescence Detectors

Purpose: To investigate the use of optically stimulated luminescence (OSL) detectors (OSLDs) for measurements of dose-averaged linear energy transfer (LET) in patient-specific proton therapy treatment fields. Methods: We used Al{sub 2}O{sub 3}:C OSLDs made from the same material as commercially available nanoDot OSLDs from Landauer, Inc. We calibrated two parameters of the OSL signal as functions of LET in therapeutic proton beams: the ratio of the ultraviolet and blue emission intensities (UV/blue ratio) and the OSL curve shape. These calibration curves were created by irradiating OSLDs in passively scattered beams of known LET (0.96 to 3.91 keV/µm). The LET values were determined using a validated Monte Carlo model of the beamline. We then irradiated new OSLDs with the prescription dose (16 to 74 cGy absorbed dose to water) at the center of the spread-out Bragg peak (SOBP) of four patient-specific treatment fields. From readouts of these OSLDs, we determined both the UV/blue ratio and OSL curve shape parameters. Combining these parameters with the calibration curves, we were able to measure LET using the OSLDs. The measurements were compared to the theoretical LET values obtained from Monte Carlo simulations of the patient-specific treatments fields. Results: Using the UV/blue ratio parameter, we were able to measure LET within 3.8%, 6.2%, 5.6% and 8.6% of the Monte Carlo value for each of the patient fields. Similarly, using the OSL curve shape parameter, LET measurements agreed within 0.5%, 11.0%, 2.5% and 7.6% for each of the four fields. Conclusion: We have demonstrated a method to verify LET in patient-specific proton therapy treatment fields using OSLDs. The possibility of enhancing biological effectiveness of proton therapy treatment plans by including LET in the optimization has been previously shown. The LET verification method we have demonstrated will be useful in the quality assurance of such LET optimized treatment plans. DA Granville received financial support from the Natural Sciences and Engineering Research Council of Canada.

60 APPLIED LIFE SCIENCES↗

Land-surface parameter optimisation using data assimilation techniques: the adJULES system V1.0

Land-surface models (LSMs) are crucial components of the Earth system models (ESMs) that are used to make coupled climate–carbon cycle projections for the 21st century. The Joint UK Land Environment Simulator (JULES) is the land-surface model used in the climate and weather forecast models of the UK Met Office. JULES is also extensively used offline as a land-surface impacts tool, forced with climatologies into the future. In this study, JULES is automatically differentiated with respect to JULES parameters using commercial software from FastOpt, resulting in an analytical gradient, or adjoint, of the model. Using this adjoint, the adJULES parameter estimation system has been developed to search for locally optimum parameters by calibrating against observations. This paper describes adJULES in a data assimilation framework and demonstrates its ability to improve the model–data fit using eddy-covariance measurements of gross primary production (GPP) and latent heat (LE) fluxes. adJULES also has the ability to calibrate over multiple sites simultaneously. This feature is used to define new optimised parameter values for the five plant functional types (PFTs) in JULES. The optimised PFT-specific parameters improve the performance of JULES at over 85 % of the sites used in the study, at both the calibration and evaluation stages. Furthermore, the new improved parameters for JULES are presented along with the associated uncertainties for each parameter.

58 GEOSCIENCES↗

Modeling soil temperature in a temperate region: A comparison between empirical and physically based methods in SWAT

Although Soil and Water Assessment Tool (SWAT) has been widely used in temperate regions, the performance of its soil temperature module has not been extensively assessed. The aim of the present study was to evaluate the performance of the SWAT model’s built-in empirical soil temperature module and a physically-based soil temperature algorithm using four years of daily soil temperature measurements at three depths (i.e., 5, 10, and 50 cm) across 10 monitoring stations in and around the Choptank River watershed, Maryland, USA. Two versions of physically-based soil temperature module were considered: one was calibrated using parameter values adopted from previous studies, another one remained calibrated. Results show that the empirical soil temperature module and both versions of physically-based soil temperature module reproduce well variations of measured soil temperatures at 5 and 10 cm depths for all stations in non-winter seasons. However, the empirical and uncalibrated physically-based soil temperature modules tended to underestimate soil temperatures in non-winter seasons at the deeper soil layer (50 cm depth); they also severely underestimated soil temperatures in winter for soil surface layers (5 and 10 cm depths). Results indicate that the calibrated physically-based soil temperature module improved soil temperature simulation, especially for winter due to its accounting for insulation effect of crop residue on soil surface. This study suggested that when equipping a physically-based soil temperature module in a hydrological model, a better representation of surface residue was needed for applications in agricultural watersheds and assessing best management practices.

soil temperature, surface residue, heat transfer, ↗

Optimization of a Remote Sensing Energy Balance Method over Different Canopy Applied at Global Scale

Parameterization methods which calculate turbulent heat and water fluxes with thermal remote sensing data were evaluated in the revised remote sensing surface energy balance system (SEBS) model (Chen et al., 2013). The model calculates sensible heat (H) based on the Monin-Obukhov similarity theory (MOST) and determines latent heat (LE) as the residual of energy balance. We examined the uncertainties of H and LE in the SEBS model due to five key parameters at the local station point scale. Observations at 27 flux towers located in seven land cover types (needle-leaf forest, broad leaf forest, shrub, savanna, grassland, cropland, and sparsely vegetated land) and an artificial intelligence particle swarm optimization (PSO) algorithm was combined to calibrate the five parameters (leaf drag coefficient, leaf heat transfer coefficients, roughness length for soil, and two parameters for ground heat calculation) in the SEBS model. The root-mean-square error at the site scale was reduced by 9 W/sq.m for H, and 92 W/sq.m for LE, and their correlation coefficients were increased by 0.07 (H) and 0.11 (LE) after using the calibrated parameters. The updated model validation was further conducted globally for the remotely sensed evapotranspiration (ET) calculations. Overestimation of SEBS global ET was significantly improved by using the optimized values of the parameters. The results suggested PSO was able to consistently locate the global optimum of the SEBS model, and appears to be capable of solving the ET model optimization problem.

Chen, Xuelong↗