Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRESSURE GAUGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Vacuum measurements on the lunar surface.

Results of measurements of neutral gas pressure on the lunar surface made with a cold cathode ionization gauge carried to the moon by Apollo 14. The vacuum quality at the landing site is much influenced by the adsorption of rocket gases and their later release. During surface operations by the astronauts, the pressure was near 10 to the minus 8th torr. No data were obtained between the time of the surface operations and lunar sunset about 12 days later, at which time the temperature fell rapidly to the vicinity of 100 K. The pressure was about 10 to the minus 12th torr shortly after sunset, but intermittent releases of gas, perhaps from within the moon itself, occasionally raised the pressure by less than an order of magnitude for as long as a day or two at a time and on one occasion to about 10 to the minus 10th torr for about an hour. At lunar sunrise, as the surface was warmed rapidly to about 300 K, the pressure rose rapidly to about 10 to the minus 10th torr, most likely due to the release of absorbed gases in the immediate landing area or on the landing module itself. For comparison with interplanetary vacuum conditions, the directed pressure of the solar wind is usually less than 10 to the minus 11th torr and the pressure of random gas motion within the solar wind, less than 10 to the minus 13th torr.

Johnson, F. S.↗

Crossover as Determinant for Safety and Performance Tradeoffs in Proton Exchange Membrane Water Electrolyzers

Hydrogen (H2) crossover is a pressing challenge constraining safe and efficient operation of proton exchange membrane water electrolyzers (PEMWEs) especially amongst strides to employ thinner membranes, which enables improved energy efficiency, and elevated cathode pressures, that reduces the energy burden on downstream compressors. Here, we develop a microstructure-aware multicomponent reactive-transport framework that resolves dissolved and gaseous H2 transport pathways and mechanistically links electrode architecture to crossover related safety and performance. We show that operability is co-governed by the cathode catalyst layer (CCL) and the anode porous transport layer (APTL) which sets the H2 crossover flux and the egress capacity respectively. Elevated Pt/C ratio in the CCL suppresses crossover flux by up to 23% while a higher APTL porosity lowers H2 in O2 fraction by 0.6% in the anode effluent. We condense the findings into (cathode pressure-current density) maps overlaid with safety limits and performance targets and ultimately define two safety-performance unified metrics to gauge the size and quality of the operating window. Given the push towards higher pressure and deeper turndown for renewable integration, this study provides mechanistic design guidance to prevent crossover-induced safety risks while preserving the desired performance.

Electrolysis↗

Microgravity Liquid-Gas Two-Phase Flow: Review of Pressure Drop and Heat Transfer Correlations and Guidelines for Equipment Operability

In this report we have catalogued the flow regimes observed in microgravity, summarized correlations for the pressure drop and rate of heat transfer that are commonly used, and discuss the validation of a few correlations from available experimental results. Two-phase flow through some specific components such as bends, tees, filters and pumps are discussed from a physical perspective to guide the designer on how reduced gravity might affect their performance. Phase separation in zero gravity is addressed through the behavior and basic design concepts for devices based on passive centrifugal action, capillary forces, gas extraction through a membrane installed in a channel wall and the use of a syringe with a perforated piston to remove bubbles from small liquid volumes. We address the common instabilities that develop in flow loops owing exclusively to the two-phase nature of the flow, e.g., Ledinegg instability and concentration waves. Finally we briefly review flow metering and gauging; two-phase flow through porous media, where pressure drop and flow regime map correlations in zero-g are a current research topic; and basic operation principles of heat pipes and capillary pumped loops.

liquid-gas↗

Knittable and Washable Multifunctional MXene-Coated Cellulose Yarns

Textile-based electronics enable the next generation of wearable devices, which have the potential to transform the architecture of consumer electronics. Highly conductive yarns that can be manufactured using industrial-scale processing and be washed like everyday yarns are needed to fulfill the promise and rapid growth of the smart textile industry. By coating cellulose yarns with Ti 3 C 2 T x MXene, highly conductive and electroactive yarns are produced, which can be knitted into textiles using an industrial knitting machine. It is shown that yarns with MXene loading of ≈77 wt% (≈2.2 mg cm -1 ) have conductivity of up to 440 S cm -1 . After washing for 45 cycles at temperatures ranging from 30 to 80 °C, MXene-coated cotton yarns exhibit a minimal increase in resistance while maintaining constant MXene loading. The MXene-coated cotton yarn electrode offers a specific capacitance of 759.5 mF cm -1 at 2 mV s -1 . Additionally, a fully knitted textile-based capacitive pressure sensor is also prepared, which offers high sensitivity (gauge factor of ≈6.02), wide sensing range of up to ≈20% compression, and excellent cycling stability (2000 cycles at ≈14% compression strain). This work provides new and practical insights toward the development of platform technology that can integrate MXene in cellulose-based yarns for textile-based devices.

36 MATERIALS SCIENCE↗

Mass Gauging Demonstrator for Any Gravitational Conditions

The present invention is a mass gauging interferometry system used to determine the volume contained within a tank. By using an optical interferometric technique to determine gas density and/or pressure a much smaller compression volume or higher fidelity measurement is possible. The mass gauging interferometer system is comprised of an optical source, a component that splits the optical source into a plurality of beams, a component that recombines the split beams, an optical cell operatively coupled to a tank, a detector for detecting fringes, and a means for compression. A portion of the beam travels through the optical cell operatively coupled to the tank, while the other beam(s) is a reference.

Korman, Valentin↗

Black holes, compact objects and solar system tests in non-relativistic general covariant theory of gravity

We study spherically symmetric static spacetimes generally filled with an anisotropic fluid in the nonrelativistic general covariant theory of gravity. In particular, we find that the vacuum solutions are not unique, and can be expressed in terms of the U(1) gauge field A. When solar system tests are considered, severe constraints on A are obtained, which seemingly pick up the Schwarzschild solution uniquely. In contrast to other versions of the Horava-Lifshitz theory, non-singular static stars made of a perfect fluid without heat flow can be constructed, due to the coupling of the fluid with the gauge field. These include the solutions with a constant pressure. We also study the general junction conditions across the surface of a star. In general, the conditions allow the existence of a thin matter shell on the surface. When applying these conditions to the perfect fluid solutions with the vacuum ones as describing their external spacetimes, we find explicitly the matching conditions in terms of the parameters appearing in the solutions. Such matching is possible even without the presence of a thin matter shell.

79 ASTRONOMY AND ASTROPHYSICS↗

Supersonic-Spray Cleaner

Spraying system for cleaning mechanical components uses less liquid and operates at pressures significantly lower. Liquid currently used is water. Designed to replace chlorofluorocarbon (CFC) solvent-based cleaning and cleanliness verification methods. Consists of spray head containing supersonic converging/diverging nozzles, source of gas at regulated pressure, pressurized liquid tank, and various hoses, fittings, valves, and gauges. Parameters of nozzles set so any of large variety of liquids and gases combined in desired ratio and rate of flow. Size and number of nozzles varied so system built in configurations ranging from small hand-held spray heads to large multinozzle cleaners. Also used to verify part adequately cleaned. Runoff liquid from spray directed at part collected. Liquid analyzed for presence of contaminants, and part recleaned if necessary.

Caimi, Raoul E. B.↗

Calf Venous Compliance in Supine Posture Equals that Measured with Head-up Tilt

Calf venous compliance is measured conventionally with venous occlusion, where compliance equals calf volume elevation per mmHg thigh occlusion pressure in relaxed legs of supine subjects. Compliance may also be measured during stepwise head-up tilt (HUT) as calf volume elevation per mmHg gravitational venous pressure elevation produced by HUT. Although HUT on a tilt table with a footplate activates calf muscles which could reduce compliance, this muscle activation is relatively small (less than or = 10% of maximal voluntary levels). Therefore, we hypothesized that calf compliance measured with HUT equals that measured with conventional supine venous occlusion. The venous occlusion protocol consisted of 20, 40, 60 and 80 mmHg thigh cuff inflations held for 1, 2, 3 and 4 min, respectively, in 14 supine subjects. One min of cuff deflation to 0 mmHg separated occlusions. Nine other subjects underwent HUT through the following angles held for 30s each: -12 deg., -6 deg., 0 deg., 12 deg., 30 deg., 54 deg., and 90 deg. HUT calf venous pressure data were interpolated from Katkov and Chestukhin; these data correspond to 70-80% of calculated calf venous pressure changes (pgh). Liquid metal-in-silastic strain gauges measured calf volume for both venous occlusion and HUT compliance. Relaxed calf compliance in supine subjects equaled 4.6 +/- 0.4 ml/mmHg (X +/- SE), as measured with venous occlusion. Calf compliance during HUT equaled 4.6 +/- 1.0 ml/mmHg. Therefore, calf compliance in supine, relaxed subjects equals that measured during head-up tilt. We conclude that the minimal calf muscle activation which occurs during HUT does not importantly affect calf compliance.

Watenpaugh, Donald E.↗

Molten Salt Reactor Experiment (MSRE) Lay-Up - 19187

UCOR, an AECOM-led partnership with Jacobs, manages the cleanup of the 2,200-acre East Tennessee Technology Park for its client, the U.S. Department of Energy (DOE), in Oak Ridge, Tennessee. The site was contaminated with radioactive, hazardous and industrial wastes generated by more than 40 years of national defense and energy missions. 2019 is the 50. anniversary of the shutdown of the Molten Salt Reactor Experiment (MSRE). MSRE ran a brief four years in the 1960's but earned an enduring legacy as an innovative reactor technology concept which has enjoyed a renewal of global interest in the past several years. In 2018, it was given elevated status among advanced reactor programs within DoE's Nuclear Energy office. The MSRE was a graphite-moderated, liquid fueled reactor that operated from June 1965 through December 1969. Although it was shut down nearly 50 years ago, certain systems within the reactor have continued to operate to maintain the facility in a safe and stable condition until it can be demolished as part of the comprehensive cleanup of the Oak Ridge Reservation. These systems are composed of a complex network of pipes, valves, gauges and associated equipment that control air filtration and pressure buildup resulting from fluorine gas generated through radiolysis of the fluoride salt which once fueled the reactor. In 2016, an MSRE Engineering Evaluation Team was chartered to assess current facility conditions and develop recommendations to maintain the facility in a safe state until deactivation and demolition commences. Plans are now underway to 'lay up' the MSRE facility until deactivation and demolition can occur. The proposed MSRE Facility Layup will minimize maintenance costs, reduce personnel risk of injury and exposure, provide reliable electric service to the facility and require zero personnel occupancy at MSRE. In the proposed layup approach a new source of electrical power to required loads will be routed through the facility, and new gas processing and ventilation systems will be installed that will be optimized for safe processing of the constituent hazardous gasses that exist in the legacy vessels at MSRE. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of an Experimental Approach for Thermal Testing in Bedded Salt - 19431

Safe and permanent isolation of used nuclear fuel (UNF) and high-level nuclear waste (HLW) is an integral component of the cradle-to-grave philosophy of radioactive waste management. Out of the multitude of rock types considered for the permanent deep disposal of nuclear waste (tuff, shale, granite, clay, and salt), salt has received significant interest particularly because of the advantage offered by salt as an impermeable and dry medium with self-sealing properties. The concept of HLW disposal in salt has been investigated through several testing campaigns in the U.S. and in Germany. Serval knowledge gaps still exist in our understanding of how brine is generated and how it transports under heat generating conditions. These knowledge gaps limit our ability to build a robust safety case for the disposal of heat generating waste in salt. The current manuscript reports on efforts performed to develop a field-testing campaign to study brine and water vapor migration in heated salt. The paper summarizes initial work done in a phased thermal testing program in bedded salt at the Waste Isolation Pilot Plant (WIPP), Carlsbad, New Mexico. The testing to date has been focused on existing boreholes and is being used to 'shakedown' the process for implementation of a more refined testing program that will be implemented in freshly drilled boreholes planned for FY2019. We designed and deployed a heater assembly that consisted of a packer, borehole deformation gauge, heater block, a network of thermocouples, and a pressure transducer setup to measure in situ temperature and pressure. The assembly was deployed in an existing borehole and several heating and cooling experiments were performed to test the performance of the different instruments fielded. We report on the results obtained for brine generation as a function of time and heating and cooling cycles and temperature evolution in the rock salt. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Precipitation Meteorological Instruments (PRECIPMET) Handbook

The PRECIPMET surface meteorology instrument system provides temperature, relative humidity, pressure, wind speed and direction, and precipitation data relevant to the precipitation network instruments: laser disdrometer (PARS2) and radar wind profiler (RWP). The PRECIPMET is installed at the intermediate facilities (IF) of the U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) atmospheric observatory. The instrument system consists of a Vaisala WXT520 weather transmitter and a 12”-diameter Novalynx tipping bucket rain gauge (TBRG). The WXT520 is mounted on top of the control building at a height of approximately 4 meters. The tipping bucket is mounted on a pole level with the surrounding fencing (approximately 2 meters) to prevent physical interference with the gauge.

54 ENVIRONMENTAL SCIENCES↗

Wall Pressure Unsteadiness and Side Loads in Overexpanded Rocket Nozzles

Surveys of both the static and dynamic wall pressure signatures on the interior surface of a sub-scale, cold-flow and thrust optimized parabolic nozzle are conducted during fixed nozzle pressure ratios corresponding to FSS and RSS states. The motive is to develop a better understanding for the sources of off-axis loads during the transient start-up of overexpanded rocket nozzles. During FSS state, pressure spectra reveal frequency content resembling SWTBLI. Presumably, when the internal flow is in RSS state, separation bubbles are trapped by shocks and expansion waves; interactions between the separated flow regions and the waves produce asymmetric pressure distributions. An analysis of the azimuthal modes reveals how the breathing mode encompasses most of the resolved energy and that the side load inducing mode is coherent with the response moment measured by strain gauges mounted upstream of the nozzle on a flexible tube. Finally, the unsteady pressure is locally more energetic during RSS, albeit direct measurements of the response moments indicate higher side load activity when in FSS state. It is postulated that these discrepancies are attributed to cancellation effects between annular separation bubbles.

Baars, Woutijn J.↗

Portable Dew Point Mass Spectrometry System for Real-Time Gas and Moisture Analysis

A portable instrument incorporates both mass spectrometry and dew point measurement to provide real-time, quantitative gas measurements of helium, nitrogen, oxygen, argon, and carbon dioxide, along with real-time, quantitative moisture analysis. The Portable Dew Point Mass Spectrometry (PDP-MS) system comprises a single quadrupole mass spectrometer and a high vacuum system consisting of a turbopump and a diaphragm-backing pump. A capacitive membrane dew point sensor was placed upstream of the MS, but still within the pressure-flow control pneumatic region. Pressure-flow control was achieved with an upstream precision metering valve, a capacitance diaphragm gauge, and a downstream mass flow controller. User configurable LabVIEW software was developed to provide real-time concentration data for the MS, dew point monitor, and sample delivery system pressure control, pressure and flow monitoring, and recording. The system has been designed to include in situ, NIST-traceable calibration. Certain sample tubing retains sufficient water that even if the sample is dry, the sample tube will desorb water to an amount resulting in moisture concentration errors up to 500 ppm for as long as 10 minutes. It was determined that Bev-A-Line IV was the best sample line to use. As a result of this issue, it is prudent to add a high-level humidity sensor to PDP-MS so such events can be prevented in the future.

Arkin, C.↗

Validation of a Cephalad Fluid Shift Countermeasure

INTRODUCTION: This project will provide critical data required to objectively determine how an optimized thigh cuff could be incorporated into the NASA integrated physiological countermeasure suite. This project will determine if thigh cuffs used during simulated spaceflight impact intracranial pressure (ICP), ocular structure and function, and intraocular pressure (IOP) using state of-the-art techniques. Additionally, some of the same methods, hardware, and protocols will be employed in the present investigation to enable direct comparisons to the International Space Station (ISS) "Fluid Shifts" experiment with Chibis-Lower Body Negative Pressure (LBNP). This study will determine the temporal physiological responses of thigh cuff application and removal on ocular and cerebral variables (including invasive ICP) in a microgravity analog. Furthermore, this proposed study will determine tissue pressure distribution applied by thigh cuffs in order to improve comfort, mobility, and efficacy of the countermeasure. Our specific aim is to determine the efficacy of a novel thigh cuff device to mitigate cephalad fluid shifts. We hypothesize that a thigh cuff countermeasure employed in a microgravity analog will temporarily reverse or attenuate ocular and cerebral-volume-pressure variables, approaching normal Earth-based seated posture, the most frequent posture assumed in daily life. In addition, we hypothesize that the magnitude of fluid and pressure redistribution using a thigh cuff countermeasure may require a longer exposure time than that of Chibis-LBNP (using ground-based data from our "Fluid Shifts" project). This project directly addresses Critical Path Roadmap Risks and Questions regarding "Risk of Spaceflight-Induced Intracranial Hypertension/Vision Alterations," and IRP Gap VIIP13: We need to identify preventative and treatment countermeasures to mitigate changes in ocular structure and function and intracranial pressure during spaceflight. METHODS: Noninvasive measures and tissue pressure distributions beneath thigh cuffs The objectives of this study are to: 1) determine the distribution of skin surface pressures beneath the advanced thigh cuff in ten subjects, 2) calibrate the built-in pressure measurement system of the advanced thigh cuff using an industry standard device, and 3) collect subjective feedback and data on the new cuff design to allow for further adjustments prior to invasive studies. A Tekscan Industrial Sensing (I-Scan) system will measure the pressure distribution of the advanced thigh cuff against the skin. In addition, we will measure blood pooling in the thigh and record the circumference of the thigh using Hokanson strain gauge plethysmography. The advanced thigh cuff will be adjusted to obtain a skin contact pressure of 30-50 mmHg as visualized on the Tekscan system. The built-in advanced thigh cuff pressure monitor will be recorded simultaneously to allow direct comparison to the Tekscan measurements. The volunteer will then remove the thigh cuff and remain at rest for five minutes with no legging applied. The thigh cuff will be donned again and pressure measurements will be taken in the same manner for up to 10 repetitions to show reproducibility of pressure after donning. At the conclusion of the study, subjects will be asked to flex their knee, stand, walk, and sit with the thigh cuff activated. During each of these maneuvers the subject will rate their pain/comfort using a modified Borg scale. Effect of thigh cuffs on ICP during simulated microgravity Ommaya reservoir patients will be recruited from the John Wayne Cancer Institute. Ommaya reservoirs provide safe and direct access for the measurement of ICP. Subjects will be instrumented for continuous blood pressure, ECG, and invasive ICP measures. The subjects will be positioned in the upright sitting posture for a 10-minute stabilization period. After the 10-minute stabilization period, imaging measures [ICP, Optical Coherence Tomography, IOP, ocular and vascular ultrasound] will be performed. Following baseline seated measures, the subject will be positioned randomly in the supine, 15deg head-down-tilt, and 15deg head-down-tilt with thigh cuffs and measures repeated. DISCUSSION: Tests to down-select thigh cuff designs will occur in early 2016. Invasive ICP and noninvasive eye imaging tests will begin in spring 2016. Supported by NSBRI through NCC 9-58.

Macias, B.↗

Vapor compression distillation module

A Vapor Compression Distillation (VCD) module was developed and evaluated as part of a Space Station Prototype (SSP) environmental control and life support system. The VCD module includes the waste tankage, pumps, post-treatment cells, automatic controls and fault detection instrumentation. Development problems were encountered with two components: the liquid pumps, and the waste tank and quantity gauge. Peristaltic pumps were selected instead of gear pumps, and a sub-program of materials and design optimization was undertaken leading to a projected life greater than 10,000 hours of continuous operation. A bladder tank was designed and built to contain the waste liquids and deliver it to the processor. A detrimental pressure pattern imposed upon the bladder by a force-operated quantity gauge was corrected by rearranging the force application, and design goals were achieved. System testing has demonstrated that all performance goals have been fulfilled.

Nuccio, P. P.↗

Interfacial gauge methods for incompressible fluid dynamics

Designing numerical methods for incompressible fluid flow involving moving interfaces, for example, in the computational modeling of bubble dynamics, swimming organisms, or surface waves, presents challenges due to the coupling of interfacial forces with incompressibility constraints. A class of methods, denoted interfacial gauge methods, is introduced for computing solutions to the corresponding incompressible Navier-Stokes equations. These methods use a type of "gauge freedom" to reduce the numerical coupling between fluid velocity, pressure, and interface position, allowing high-order accurate numerical methods to be developed more easily. Making use of an implicit mesh discontinuous Galerkin framework, developed in tandem with this work, high-order results are demonstrated, including surface tension dynamics in which fluid velocity, pressure, and interface geometry are computed with fourth-order spatial accuracy in the maximum norm. Applications are demonstrated with two-phase fluid flow displaying fine-scaled capillary wave dynamics, rigid body fluid-structure interaction, and a fluid-jet free surface flow problem exhibiting vortex shedding induced by a type of Plateau-Rayleigh instability. The developed methods can be generalized to other types of interfacial flow and facilitate precise computation of complex fluid interface phenomena.

42 ENGINEERING↗

Equation of State and Damage in Polyethylene

The dynamic response of polymers differs significantly from those of metals, upon which many of the National Laboratories' deformation, damage, and failure models are based. Their moduli, yield strength, and damage characteristics are highly strain rate-, temperature-, and phase-dependent, requiring models that encompass a wide range of phenomena including some not in equilibrium. Recently, Los Alamos developed the Glassy Amorphous Polymer (GAP) 1 model [1] to address limitations in existing models of polymer deformation. GAP captures both volumetric (equation of state) and deviatoric (shear) response, including a non-equilibrium component to the former (a feature determined to be crucial in capturing the low-pressure, viscoelastic response to impact loading). GAP has already been applied to polymers such as PMMA, PTFE, epoxy, and Kel-F 800, but with an emphasis on impact response as opposed to damage or failure. The current effort was launched to address this gap in predictive capability. For reasons that will be made clear, semi-crystalline polyethylene (PE) was chosen to serve as a model system for parameterization and validation. PE (-C 2 H 4- )n is one of the most widely used polymers in industrial and engineering contexts, chiey due to the versatility of its mechanical response. This response can be tuned through network and chain structure, degree of crystallinity, and molecular weight. PE is found in several forms including low density (LDPE), high density (HDPE), and ultra-high molecular weight (UHMWPE). The focus here was on HDPE and UHMWPE, of pedigree described in the following section. Materials were well-characterized prior to study and are representative of semi-crystalline polymers of interest to DOE and DoD. Semi-crystalline PE undergoes a glass transition at low temperature (-35°C) and melts across a range of moderate temperatures (~80-180°C), depending on its structure. It is typically inert chemically, has low strength and high ductility, and the high strength and anisotropy of UHMWPE ber, in particular, have driven its use in engineering, impact, and armor applications. Surprisingly little is known, however, about the influence of PE's crystalline structure and associated phase transitions (including melt) on its response to dynamic compression. A broad suite of experiments was used to calibrate the GAP model for HDPE and UHMWPE. Section IV examines the effects of tensile strain on the structure and integrity of PE crystalline domains. These data were used to inform the preliminary damage model described in Section XII, whose roots lie in statistical physics and network theory. The viscoelastic and plastic components of GAP rely heavily on the stress-strain data of Section VI, which also include dynamic extrusion and Taylor anvil experiments used to validate the damage model. The thermal data of Section X provide crucial inputs to the equilibrium EOS in GAP, as well as the much broader range SESAME EOS whose construction is outlined in Section XI. Section VII details plate impact experiments characterizing the low-pressure shock locus and failure (spall) using in situ electromagnetic gauges. A previously reported \cusp" in the principal Hugoniot near 0.5 kbar was confirmed, and a multi-wave structure was observed over a limited input stress range above the cusp. This cusp is believed due to solid-solid phase transitions associated with the crystalline domains of the polymer.

36 MATERIALS SCIENCE↗

Turbine blade and vane heat flux sensor development, phase 1

Heat flux sensors available for installation in the hot section airfoils of advanced aircraft gas turbine engines were developed. Two heat flux sensors were designed, fabricated, calibrated, and tested. Measurement techniques are compared in an atmospheric pressure combustor rig test. Sensors, embedded thermocouple and the Gordon gauge, were fabricated that met the geometric and fabricability requirements and could withstand the hot section environmental conditions. Calibration data indicate that these sensors yielded repeatable results and have the potential to meet the accuracy goal of measuring local heat flux to within 5%. Thermal cycle tests and thermal soak tests indicated that the sensors are capable of surviving extended periods of exposure to the environment conditions in the turbine. Problems in calibration of the sensors caused by severe non-one dimensional heat flow were encountered. Modifications to the calibration techniques are needed to minimize this problem and proof testing of the sensors in an engine is needed to verify the designs.

Atkinson, W. H.↗