Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POLYSTYRENE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

WE-D-18A-04: How Iterative Reconstruction Algorithms Affect the MTFs of Variable-Contrast Targets in CT Images

Purpose: To determine how filtered back-projection (FBP), adaptive statistical (ASiR), and model based (MBIR) iterative reconstruction algorithms affect the measured modulation transfer functions (MTFs) of variable-contrast targets over a wide range of clinically applicable dose levels. Methods: The Catphan 600 CTP401 module, surrounded by an oval, fat-equivalent ring to mimic patient size/shape, was scanned on a GE HD750 CT scanner at 1, 2, 3, 6, 12 and 24 mGy CTDIvol levels with typical patient scan parameters: 120kVp, 0.8s, 40mm beam width, large SFOV, 2.5mm thickness, 0.984 pitch. The images were reconstructed using GE's Standard kernel with FBP; 20%, 40% and 70% ASiR; and MBIR. A task-based MTF (MTFtask) was computed for six cylindrical targets: 2 low-contrast (Polystyrene, LDPE), 2 medium-contrast (Delrin, PMP), and 2 high-contrast (Teflon, air). MTFtask was used to compare the performance of reconstruction algorithms with decreasing CTDIvol from 24mGy, which is currently used in the clinic. Results: For the air target and 75% dose savings (6 mGy), MBIR MTFtask at 5 lp/cm measured 0.24, compared to 0.20 for 70% ASiR and 0.11 for FBP. Overall, for both high-contrast targets, MBIR MTFtask improved with increasing CTDIvol and consistently outperformed ASiR and FBP near the system's Nyquist frequency. Conversely, for Polystyrene at 6 mGy, MBIR (0.10) and 70% ASiR (0.07) MTFtask was lower than for FBP (0.18). For medium and low-contrast targets, FBP remains the best overall algorithm for improved resolution at low CTDIvol (1–6 mGy) levels, whereas MBIR is comparable at higher dose levels (12–24 mGy). Conclusion: MBIR improved the MTF of small, high-contrast targets compared to FBP and ASiR at doses of 50%–12.5% of those currently used in the clinic. However, for imaging low- and mediumcontrast targets, FBP performed the best across all dose levels. For assessing MTF from different reconstruction algorithms, task-based MTF measurements are necessary.

60 APPLIED LIFE SCIENCES↗

SU-C-213-02: Characterizing 3D Printing in the Fabrication of Variable Density Phantoms

Purpose: In this work, we present characterization, process flow, quality control and application of 3D fabricated low density phantoms for radiotherapy quality assurance. Methods: A Rostock delta 3D printer using polystyrene filament of diameter 1.75 mm was used to print geometric volumes of 2×2×1 cm{sup 3} of varying densities. The variable densities of 0.1 to 0.75 g/cm {sup 3} were created by modulating the infill. A computed tomography (CT) scan was performed to establish an infill-density calibration curve as well as characterize the quality of the print such as uniformity and the infill pattern. The time required to print these volumes was also recorded. Using the calibration, two low density cones (0.19, 0.52 g/cm{sup 3}) were printed and benchmarked against commercially available phantoms. The dosimetric validation of the low density scaling of Anisotropic Analytical Algorithm (AAA) was performed by using a 0.5 g/cm{sup 3} slab of 10×10×2.4 cm{sup 3} with EBT3 GafChromic film. The gamma analysis at 3%/3mm criteria were compared for the measured and computed dose planes. Results: Analysis of the volume of air pockets in the infill resulted in a reasonable uniformity for densities 0.4 to 0.75 g/cm{sup 3}. Printed phantoms with densities below 0.4 g/cm{sup 3} exhibited a higher ratio of air to polystyrene resulting in large non-uniformity. Compared to the commercial inserts, good agreement was observed only for the printed 0.52 g/cm{sup 3} cone. Dosimetric comparison for a printed low density volume placed in-between layers of solid water resulted in >95% gamma agreement between AAA calculated dose planes and measured EBT3 films for a 6MV 5×5 cm{sup 2} clinical beam. The comparison showed disagreement in the penumbra region. Conclusion: In conclusion, 3D printing technology opens the door to desktop fabrication of variable density phantoms at economical prices in an efficient manner for the quality assurance needs of a small clinic.

60 APPLIED LIFE SCIENCES↗

SU-E-T-388: Evaluation of Electronic Brachytherapy Dose Distributions in Tissue Equivalent Materials

Purpose: To study the measured and calculated dose distributions for electronic brachytherapy (EBT) in various tissue equivalent homogenous materials. Methods: Calculated dose distributions in water were generated using published TG-43 parameters in Varian BrachyVision software for a 50 kVp, 50 cm Xoft source. Dose distributions were measured within a 3D-scanning tank using dosimeters including: PTW 0.125 cc, pin-point, and parallel-plate ion chambers, Sun Nuclear “Edge” diode and Gafchromic EBT3 film. Multi-channel film dosimetry was used in film analysis. EBT3 film curves were calibrated via radial dose comparison to both independently measured and published data. The resulting film calibration was utilized to measure dose distributions created by titanium filtered source utilized in clinical brachytherapy applications. Data was collected within homogenous PMMA, vinyl, polystyrene, paraffin, and water-equivalent plastic phantoms. Results: Ion-chamber data was corrected to effective points of measurement and normalized prior to comparison between calculated and measured dose distributions. Measurements made in water and water equivalent materials compared well with results from treatment planning software. The maximum percent differences (relative to water) observed between 1 cm and 3.5 cm depth from source for each of the phantom materials are as follows: PMMA 35%, polystyrene 41%, plastic-water 23%, vinyl 115%, and paraffin 46%. Conclusion: The increased probability of photoelectric interactions occurring within the patient during electronic brachytherapy will emphasize the radiological differences between varying human tissues in dose deposition. These differences can Result in clinically significant dose perturbations and it is therefore recommended to move to a model based dose calculation, as outlined in TG-186, to improve the dosimetric accuracy of low energy EBT.

60 APPLIED LIFE SCIENCES↗

Rheological Behavior of Oligomeric Ionomers

The rheological behavior of the alkali metal salts of oligomeric sulfonated polystyrene (PS) ionomers was characterized using dynamic and steady shear measurements. The starting PS had a weight average molecular weight of 4000 g/mol and a narrow molecular weight distribution (1.06). Two sulfonation levels were examined, 2.5 and 4.8 mol %, which corresponded, respectively, to one and two sulfonate groups per chain on average. The ionomers exhibited nanophase separation of an ion-rich phase, and as a consequence, time-temperature superposition failed for all samples. Sulfonation increased the melt viscosity of the ionomers, as much as seven orders of magnitude. The zero shear viscosity scaled as cq/a, where c was the concentration of the ionic groups, q was the charge of the cation, and a was the cation radius, and although the molecular weight of the parent polystyrene was much lower than the entanglement molecular weight, the ionomer melts exhibited strong elastic behavior. The flow activation energy of the ionomers was similar to that of high molecular weight PS and the calculated molecular weight between 'entanglements' of the ionomers was the same as for PS.

59 BASIC BIOLOGICAL SCIENCES↗

Silicon photomultiplier choice for the scintillating fibre tracker in second generation proton computed tomography scanner

Scintillating fibers are capable of charged particle tracking with high position resolution, as demonstrated by the central fiber tracker of the D0 experiment. The charged particles will deposit less energy in the polystyrene scintillating fibers as opposed to a typical silicon tracker of the same thickness, while SiPM's are highly efficient at detecting photons created by the passage of the charged particle through the fibers. The current prototype of the Proton Computed Tomography (pCT) tracker uses groups of three 0.5 mm green polystyrene based scintillating fibers connected to a single SiPM, while first generation prototype tracker used Silicon strip detectors. The results of R&D for the Scintillating Fiber Tracker (SFT) as part of the pCT detector are outlined, and the premise for the selection of SiPM is discussed.

43 PARTICLE ACCELERATORS↗

Effect of Molecular Weight on the Morphology of a Polymer Semiconductor–Thermoplastic Elastomer Blend

Abstract Polymer semiconductors (PSCs) are essential active materials in mechanically stretchable electronic devices. However, many exhibit low fracture strain due to their rigid chain conformation and the presence of large crystalline domains. Here, a PSC/elastomer blend, poly[((2,6‐bis(thiophen‐2‐yl)‐3,7‐bis(9‐octylnonadecyl)thieno[3,2‐b]thieno[2′,3′:4,5]thieno[2,3‐d]thiophene)‐5,5′‐diyl)(2,5‐bis(8‐octyloctadecyl)‐3,6‐di(thiophen‐2‐yl)pyrrolo[3,4‐c]pyrrole‐1,4‐dione)‐5,5′‐diyl]] (P2TDPP2TFT4) and polystyrene‐ block ‐poly(ethylene‐ran‐butylene)‐ block ‐polystyrene (SEBS) are systematically investigated. Specifically, the effects of molecular weight of both SEBS and P2TDPP2TFT4 on the resulting blend morphology, mechanical, and electrical properties are explored. In addition to commonly used techniques, atomic force microscopy‐based nanomechanical images are used to provide additional insights into the blend film morphology. Opposing trends in SEBS‐induced aggregation are observed for the different P2TDPP2TFT4 molecular weights upon increasing the SEBS molecular weight from 87 to 276 kDa. Furthermore, these trends are seen in device performance trends for both molecular weights of P2TDPP2TFT4. SEBS molecular weight also has a substantial influence on the mesoscale phase separation. Strain at fracture increases dramatically upon blending, reaching a maximum value of 640% ± 20% in the blended films measured with film‐on‐water method. These results highlight the importance of molecular weight for electronic devices. In addition, this study provides valuable insights into appropriate polymer selections for stretchable semiconducting thin films that simultaneously possess excellent mechanical and electrical properties.

36 MATERIALS SCIENCE↗

Surfactant-Induced Interfacial Aggregation of Porphyrins for Structuring Color-Tunable Liquids

Locking nonequilibrium shapes of liquids into targeted architectures by interfacial jamming of nanoparticles is an emerging area in material science. 5,10,15,20-tetrakis(4-sulfonatophenyl) porphyrin (H 6 TPPS) shows three different aggregation states that present an absorption imaging platform to monitor the assembly and jamming of supramolecular polymer surfactants (SPSs) at the liquid/liquid interface. The interfacial interconversion of H 6 TPPS, specifically H 4 TPPS 2- dissolved in water, from J- to an H-aggregation was induced by strong electrostatic interactions with amine-terminated polystyrene dissolved in toluene at the water/toluene interface. We find that this resulted in color-tunable liquids due to interfacial jamming of the SPSs formed between H 4 TPPS 2- and amine-terminated polystyrene. However, the formed SPSs cannot lock in nonequilibrium shapes of liquids. In addition, a self-wrinkling behavior was observed when amphiphilic triblock copolymers of PS-block-poly(2-vinylpyridine)-block-poly(ethylene oxide) were used to interact with H 4 TPPS 2- . Subsequently, the SPSs formed can lock in nonequilibrium shapes of liquids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Size and structure of Chlorella zofingiensis /FeCl 3 flocs in a shear flow: Algae Floc Structure

Flocculation is a promising method to overcome the economic hurdle to separation of algae from its growth medium in large scale operations. But, understanding of the floc structure and the effects of shear on the floc structure are crucial to the large scale implementation of this technique. The floc structure is important because it determines, in large part, the density and settling behavior of the algae. Freshwater algae floc size distributions and fractal dimensions are presented as a function of applied shear rate in a Couette cell using ferric chloride as a flocculant. Comparisons are made with measurements made for a polystyrene microparticle model system taken here as well as reported literature results. The algae floc size distributions are found to be self-preserving with respect to shear rate, consistent with literature data for polystyrene. Moreover, three fractal dimensions are calculated which quantitatively characterize the complexity of the floc structure. Low shear rates result in large, relatively dense packed flocs which elongate and fracture as the shear rate is increased. Our results presented here provide crucial information for economically implementing flocculation as a large scale algae harvesting strategy.

59 BASIC BIOLOGICAL SCIENCES↗

Assessing a Spectroelectrochemical Sensor's Performance for Detecting [Ru(bpy)3]2+ in Natural and Treated Water

A spectroelectrochemical sensor that combines three modes of selectivity in a single device was evaluated in natural and treated water samples using tris-(2,2’-bipyridyl) ruthenium(II) dichloride hexahydrate, [Ru(bpy)3]2+, as a model analyte. The sensor was an optically transparent indium tin oxide (ITO) electrode coated with a thin film of partially sulfonated polystyrene-block-poly(ethylene-ran-butylene)-block-polystyrene (SSEBS). As the potential of the ITO electrode was cycled from +0.7 to +1.3 V, the analyte changed from the colored [Ru(bpy)3]2+ complex to colorless [Ru(bpy)3]3+ complex and the change in absorbance at 450 nm was used as the optical signal for quantification. Calibration curves were obtained for [Ru(bpy)3]2+ in natural well water, river water and treated tap water with detection limits of 108, 139 and 264 nM, respectively. A standard addition method was developed to determine an *unknown* spike addition concentration of [Ru(bpy)3]2+ in well water. The spectroelectrochemical sensor determined the concentration of [Ru(bpy)3]2+ spiked into a sample of Hanford well water to be 0.39*0.03 mM versus the actual concentration of 0.40 mM.

ITO electrode↗

Alignment frustration in block copolymer films with block copolymer grafted TiO 2 nanoparticles under soft-shear cold zone annealing

Block copolymers (BCPs) have received significant attention as promising candidates for sequestering nanoparticles and fabrication of aligned nanostructures with optimal optical or electrical properties. We investigate the influence of static and dynamic thermal field on the alignment of polystyrene-block-poly(methyl methacrylate) (PS-b-PMMA) BCP morphology with the loading of novel poly(methyl methacrylate-block-Polystyrene) (PMMA-b-PS)-grafted-TiO 2 nanoparticles (BCP-g-TiO 2 ). Observation of characteristics IR peaks for PMMA and PS in BCP-g-TiO 2 nanoparticles and Transmission Electron Microscopy (TEM) results of the outer coating of core nanoparticle, validate the grafting to approach in synthesizing BCP-g-TiO 2 . In this work, we report that under the sharp dynamic thermal field, at low loading of BCP-g-TiO 2 , there is good dispersion of nanoparticles in unidirectionally aligned BCP matrix in film interior probed by GISAXS, while, at high nanoparticle loading (~10 wt%), there is local frustration in the unidirectional alignment of the BCP matrix due to aggregation of BCP-g-TiO 2 nanoparticles. However, Grazing incidence small angle X-ray scattering (GISAXS) shows clearly that the BCP films remain largely locally ordered at the domain scale, despite these large perturbations to long-range ordering even at high loading level, while bringing in new TiO 2 functionality to the BCP films, such as UVO absorptivity or biofouling prevention, important to potential new applications of such membranes.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Degradation in Photovoltaic Encapsulant Transmittance: Results of the Second PVQAT TG5 Artificial Weathering Study

The optical degradation of encapsulants from ultraviolet (UV) radiation has historically resulted in a significant loss in performance throughout the life of a photovoltaic (PV) module. International Electrotechnical Commission (IEC) test methods have recently been developed to screen for PV encapsulants prone to loss in optical performance. The present study was performed to benchmark polymeric packaging materials relative to IEC 62788-1-4 (covering the measurement of optical transmittance) and IEC 62788-1-7 (on the durability of transmittance), provide feedback toward improvement of the methods, and develop insight regarding optical degradation. Contemporary materials were examined, including poly(ethylene-co-vinyl acetate) (EVA), thermoplastic polyolefin (TPO), polyolefin elastomer (POE), and polyvinyl butyral (PVB) encapsulants; a poly(ethene-co-tetrafluoroethene)/poly(ethylene terephthalate) (ETFE/PET) transparent backsheet; and a polystyrene (PS) working reference material. The use of silica-, specialty-, and rolled-glass was also compared in laminated coupons. Specimen size was separately examined from 2.5 to 12.5 cm. Weathering was performed with a xenon source, using IEC TS 62788-7-2 methods A2, A3, A4, and A5 (chamber temperature of 55 degrees C, 65 degrees C, 75 degrees C, or 85 degrees C), respectively. Characterizations were made using a UV-visible-near-infrared (UV-VIS-NIR) spectrophotometer (transmittance and reflectance, with and without an integrating sphere), a UV-VIS fluorescence spectrophotometer, a camera, and an optical microscope. Performance was analyzed, including solar weighted transmittance, yellowness index, UV cut-off wavelength, and haze (scattering). Separate Arrhenius analyses were performed to assess retention of transmittance and changes in yellowness index. The activation energy for both characteristics was found to range from 15-80 kJ mol-1, with an average of 48 kJ mol-1, similar to the average of 45 kJ mol-1 identified in the previous international PV Quality Assurance Task Force (PVQAT) Task Group 5 (TG5) study of more traditional encapsulants. The separate degradation modes of discoloration and scattering were distinguished in the encapsulants using a comprehensive spectral characterization. Based on these results, the IEC 62788-1-7 pass/fail criteria of 5% change in transmittance was confirmed to identify a known bad encapsulant.

durability↗

Simulation of local ion transport in lamellar block copolymer electrolytes based on electron micrographs

A method is presented in this paper to relate local morphology and ionic conductivity in a solid, lamellar block copolymer electrolyte for lithium batteries, by simulating conductivity through transmission electron micrographs. The electrolyte consists of polystyrene-block-poly(ethylene oxide) mixed with lithium bis(trifluoromethanesulfonyl) imide salt (SEO/LiTFSI), where the polystyrene phase is structural phase and the poly(ethylene oxide)/LiTFSI phase is ionically conductive. The electric potential distribution is simulated in binarized micrographs by solving the Laplace equation with constant potential boundary conditions. A morphology factor, f, is reported for each image by calculating the effective conductivity relative to a homogenous conductor. Images from two samples are examined, one annealed with large lamellar grains and one unannealed with small grains. The average value off is 0.45 ± 0.04 for the annealed sample, and 0.37 ± 0.03 for the unannealed sample, both close to the value predicted by effective medium theory, 1/2. Simulated conductivities are compared to published experimental conductivities. The value of f Unannealed /f Annealed is 0.82 for simulations and 6.2 for experiments. Simulation results correspond well to predictions by effective medium theory but do not explain the experimental measurements. Finally, observation of nanoscale morphology over length scales greater than the size of the micrographs (~1 μm) may be required to explain the experimental results.

36 MATERIALS SCIENCE↗

Self-Supplied Liquid Injection Field Desorption/Ionization Ion Source for an Orthogonal Time-of-Flight Instrument

A new implementation of a dedicated ion source for field ionization (FI), field desorption (FD), and liquid injection field desorption/ionization (LIFDI) for the JEOL AccuTOF GC series of orthogonal-acceleration time-of-flight instruments is presented. In contrast to existing implementations, this third-party LIFDI probe and source combination does not require the exchange of the entire ion source comprising ion source block and lens stack to switch from electron ionization (EI) to LIFDI. Rather, the methods may be swapped conveniently by only exchanging the ion source block for a mechanical probe guide and inserting the LIFDI probe in place of the standard direct insertion probe (DIP) via the vacuum lock. Further, this LIFDI setup does not require any changes of the electronics or software of the AccuTOF mass spectrometer because it is self-supplied in terms of power supply, observation optics, and computer control. The setup offers advanced FI/FD/LIFDI control features such as emission-controlled emitter heating current and emitter flash baking during elongated runs as required for gas chromatography-FI-mass spectrometry (MS). The LIFDI source and probe and its operation are reported in detail. FI spectra of the volatile analytes toluene, heptane, and pentafluoroiodobenzene are presented. LIFDI operation is demonstrated for the analysis of the saturated hydrocarbon dotriacontane and the low-mass hydrocarbon polymers polystyrene 484 and polystyrene 1050. Further, the air-sensitive 2nd-generation Hoveyda–Grubbs catalyst is analyzed by LIFDI-MS. For comparison with long-established LIFDI instrumentation, some of the spectra obtained with the new setup are also compared with those from a double-focusing magnetic sector instrument. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Molecular dynamics simulations of energy accommodation between gases and polymers for ultra-low thermal conductivity insulation

Determining the energy accommodation between gases and solids is essential to developing porous thermal insulation materials with ultra-low effective thermal conductivity that reduce energy use, greenhouse gas emissions, and fossil fuel consumption. The energy accommodation coefficients of most gases, however, have been rarely studied, especially with respect to solids that have relatively high thermal resistivity, e.g., polymers. Here, by using all-atom nonequilibrium molecular dynamics simulations, we reveal the accommodation coefficients of He, Ar, N 2 , and O 2 with polymers, mainly polystyrene. We find that their values are around 0.51, 0.72, 0.79, and 0.90, respectively, suggesting a critical reexamination of the commonly used theoretical maximum value of 1. We have also conducted experiments and validated the value for air, which is about 0.81. Such a change in accommodation coefficients can lead to a reduction of about 70%, 50%, 35%, and 20% in the thermal conductivity of He, Ar, N 2 , and O 2 gases in nano pores (below 100 nm) or at low pressures (below 1 millibar). With these new accommodation coefficients, we find that in a 10 nm pore with ambient pressure at 300 K, the gas thermal conductivity of He, Ar, N 2 , and O 2 in porous polystyrene can be as low as 9.7 × 10 –4 , 3.4 × 10 –4 , 7.3 × 10 –4 , and 8.5 × 10 –4 W·m –1 ·K –1 , respectively, which are two to three orders of magnitude lower than their bulk values, promising higher thermal resistivity of insulation materials. This work reveals the fundamental energy exchange between gases and polymers, providing important guidance for designing high-performance thermal insulation materials for various applications.

36 MATERIALS SCIENCE↗

Bulk magnetization and 1H NMR spectra of magnetically heterogeneous model systems

Bulk magnetization and ¹H static and magic angle spinning (MAS) nuclear magnetic resonance (NMR) spectra of two magnetically heterogeneous model systems based on laponite (LAP) layered silicate or polystyrene (PS) with low and high proton concentration, respectively, and ferrimagnetic Fe₂O₃ nano- or micro-particles have been studied. In LAP+Fe₂O₃, a major contribution to the NMR signal broadening is due to the dipolar coupling between the magnetic moments of protons and magnetic particles. In PS+Fe₂O₃, due to the higher proton concentration in polystyrene and stronger proton–proton dipolar coupling, an additional broadening is observed, i.e. ¹H MAS NMR spectra of magnetically heterogeneous systems are sensitive to both proton–magnetic particles and proton–proton dipolar couplings. An increase of the volume magnetization by ~1 emu/cm³ affects the ¹H NMR signal width in a way that is similar to an increase of the proton concentration by ~2×10²²/cm³. ¹H MAS NMR spectra, along with bulk magnetization measurements, allow the accurate determination of the hydrogen concentration in magnetically heterogeneous systems.

Bulk magnetization↗

Quantifying the Influence of Size, Shape, and Density of Microplastics on Their Transport Modes: A Modeling Approach

Microplastics (MPs) pose significant risks to marine ecosystems and human health, necessitating accurate predictions of their distributions in aquatic environments for effective risk mitigation. However, understanding MP transport dynamics is challenging because of the inadequate representation of MP characteristics such as size, shape, and density in numerical models. Further, the accuracy of the MP vertical profiles in existing models has not been thoroughly validated. Thus, we developed an MP transport model within the Finite Volume Community Ocean Model framework (FVCOM-MP) by integrating MP characteristics. We validated FVCOM-MP against experimental and analytical data, focusing on various MP transport modes and transitions. FVCOM-MP successfully replicates MP profiles in different transport modes, including the bedload, surface-load, suspended-load, and mixed-load modes. Additionally, we introduce phase diagrams for classifying MP transport modes based on particle characteristics, enhancing our understanding of MP dynamics in aquatic systems. The transport modes for a number of real-world MP particles, including fishing line, plastic bag/bottle fragments, synthetic fibers, tire wear particles, polyvinyl chloride and expanded polystyrene pellets, were analyzed with these phase diagrams.

Microplastic transport, Settling velocity, Rising ↗

$\mathrm{ATR}$-$\mathrm{FTIR}$ spectroscopy as a probe for metal ion binding onto immobilized ligands

ATR-FTIR spectroscopy is shown to be useful in probing metal ion binding to ligands immobilized on polymer beads. Lu(III) is the metal ion, phosphinic and sulfonic acids are the immobilized ligands, and polystyrene beads crosslinked at low and high levels are the support. Analysis is based on ligand band positions and intensities before and after complexation as a function of time. ATR spectra of the phosphinic acid show two types of binding sites with different accessibilities: surface ligands that bind Lu(III) from solution and interior ligands that gain ions by diffusion from the surface. Initially bound Lu(III) ions are mobile within the solid phase and their movement is accompanied by the breaking of hydrogen bonds among the phosphinic acid ligands to form Lu(III) phosphinate complexes. Competition between hydrogen bonding and bond-making with Lu(III) contributes to slow sorption rates compared to results from the sulfonic acid ligand whose strong acidity and ionizability allows rapid Lu(III) sorption. Comparing ATR spectra of the phosphinic acid bound to lightly- and highly-crosslinked polystyrene shows how the extent of crosslinking affects the transport mechanism.

36 MATERIALS SCIENCE↗