Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Validation of material models for puncture of 7075-T651 aluminum plate

Plate puncture simulations are challenging computational tasks that require advanced material models including high strain rate and thermal-mechanical effects on both deformation and failure, plus finite element techniques capable of representing large deformations and material failure. The focus of this work is on the material issues, which require large sets of experiments, flexible material models and challenging calibration procedures. In this study, we consider the puncture of 12.7 mm thick, 7075-T651 aluminum alloy plates by a cylindrical punch with a hemispherical nose and diameter of 12.7 mm. The plasticity and ductile failure models were isotropic with calibration data obtained from uniaxial tension tests at different temperatures and strain rates plus quasi-static notched tension tests and shear-dominated tests described here. Sixteen puncture experiments were conducted to identify the threshold penetration energy, mode of puncture and punch acceleration during impact, The punch was mounted on a 139 kg mass and dropped on the plates with different impact speeds. Since the mass was the same in all tests, the quantity of interest was the impact speed. The axis and velocity of the punch were perpendicular to the plate surface. The mean threshold punch speed was 3.05 m/s, and the mode of failure was plugging by thermal-mechanical shear banding accompanied by scabbing fragments. Application of the material models in simulations of the tests yielded accurate estimates of the threshold puncture speed and of the mode of failure. Time histories of the punch acceleration compared well between simulation and test. Remarkably, the success of the simulations occurred in spite of even the smallest element used being larger than the width of the shear bands.

36 MATERIALS SCIENCE↗

Crystallographic texture and microstructural changes in fusion welds of recrystallized Zry-4 rolled plates

This study presents a detailed characterization of the microstructural and crystallographic texture changes observed in the transition region in a weld between two Zircaloy-4 cold rolled and recrystallized plates. The microstructural study was performed by optical microscopy under polarized light and scanning electron microscopy (SEM). Texture changes were characterized at different lengthscales: in the micrometric size, orientation imaging maps (OIM) were constructed by electron backscatter diffraction (EBSD), in the millimetre scale, high energy XRD experiments were done at the Advanced Photon Source (USA) and compared to neutron diffraction texture determinations performed in the HIPPO instrument at Los Alamos National Laboratory. In the heat affected zone (HAZ) we observed the development of Widmanstätten microstructures, typical of the α( hcp ) to β( bcc ) phase transformation. Associated with these changes a rotation of the c-poles is found in the HAZ and fusion zone. While the base material shows the typical texture of a cold rolled plate, with their c-poles pointing 35° apart from the normal direction of the plate in the normal-transversal line, in the HAZ, c-poles align along the transversal direction of the plate and then re-orient along different directions, all of these changes occurring within a lengthscale in the order of mm. The evolution of texture in this narrow region was captured by both OIM and XRD, and is consistent with previous measurements done by Neutron Diffraction in the HIPPO diffractometer at Los Alamos National Laboratory, USA. The microstructural and texture changes along the HAZ were interpreted as arising due to the effect of differences in the cooling rate and β grain size on the progress of the different α variants during transformation. Fast cooling rates and large β grains are associated to weak variant selection during the β–>α transformation, while slow cooling rates and fine β grains result in strong variant selection.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TiO{sub 2} nanotube, nanowire, and rhomboid-shaped particle thin films fixed on a titanium metal plate

Titanium dioxide thin films having various nanostructures could be formed by various treatments on sodium titanate nanotube thin films approximately 5 {mu}m thick fixed on titanium metal plates. Using an aqueous solution with a lower hydrochloric acid concentration (0.01 mol/L) and a higher reaction temperature (90 deg. C) than those previously employed, we obtained a hydrogen titanate nanotube thin film fixed onto a titanium metal plate by H{sup +} ion-exchange treatment of the sodium titanate nanotube thin film. Calcination of hydrogen titanate nanotube thin films yielded porous thin films consisting of anatase nanotubes, anatase nanowires, and anatase nanoparticles grown directly from the titanium metal plate. H{sup +} ion-exchange treatment of sodium titanate nanotube thin films at 140 deg. C resulted in porous thin films consisting of rhomboid-shaped anatase nanoparticles. - Graphical abstract: Titanium dioxide nanotube, nanowire, and rhombic particle thin films could be formed by various treatments on a sodium titanate nanotube thin film fixed on a titanium metal plate.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High strain-rate compression behavior of polymeric rod and plate Kelvin lattice structures

The compressive high strain-rate behavior of polymeric Kelvin lattice structures with rod-based or plate-based unit cells was investigated through experimental techniques and finite element simulations. Polymeric lattice structures with 5x5x5 unit cell geometries were manufactured on the millimeter scale using vat polymerization additive manufacturing and tested at low (0.001/s) and high (1000/s) strain-rates. High strain-rate experiments were performed and validated for a viscoelastic split-Hopkinson (Kolsky) pressure bar system (SHPB) coupled with high-speed imaging and digital image correlation (DIC). Experimental results at both low and high strain-rates show the formation of a localized deformation band which was more prevalent in low relative density specimens and low strain-rate experiments. Strain-rate effects of lattice specimens strongly correlate with effects of the base polymer material; both bulk polymer and lattice specimen demonstrated strain-rate hardening, strain-rate stiffening, and decreased fracture strain under dynamic loading. Results show mechanical failure properties and energy absorption depended strongly on the relative density of the lattice specimen and exhibited distinct scaling between relative density and geometry type (rod, plate) and loading rate. High relative density plate-lattices demonstrated inferior mechanical properties to rod-lattices; however, there exists a critical relative density for a given mechanical property (17%- 28%) below which plate-lattices outperform rod-lattices of similar mass. As a result, high strain-rate explicit finite element simulations were performed and showed good agreement with the mechanical failure trends and deformation modes observed in the experiments.

36 MATERIALS SCIENCE↗

Electrochemo-mechanics unlocks hidden dynamics of lithium plating under stacking pressure

Understanding and mitigating lithium plating remains one of the most pressing challenges in advancing the safety and longevity of lithium-ion batteries (LIBs). Here, we present a novel integrative framework that combines in-operando swelling force measurements with a physics-based electro-chemo-mechanical model to uncover previously inaccessible insights into lithium plating dynamics under mechanical constraints. Unlike existing approaches that focus primarily on electrochemical signatures, our approach captures the coupled mechanical responses of commercial pouch cells during cycling, revealing how mechanical constraints fundamentally alter degradation pathways. We demonstrate that the use of a moderate stacking pressure suppresses lithium plating and enhances lithium stripping. This mechanically driven structural effect, coupled with the electrochemical process, significantly extends the linear aging regime in LIBs. Intriguingly, intermittent capacity recovery events that were observed during the battery cycling suggest dynamic lithium reactivation, a phenomenon rarely captured in real-time. This study pioneers a stress-aware methodology for diagnosing and managing lithium plating, establishing a new paradigm for real-time battery health monitoring. The findings offer transformative implications for the design of durable, high-performance LIB systems, opening new avenues for intelligent control strategies in battery management systems.

Bhowmick, Amit↗

Development of a versatile plate spectrometer for electron beam characterization

A new instrument for electron beam characterization has been developed, based on measuring the range of beam electrons in different thicknesses of aluminum, to determine both the current and energy of an electron beam traveling in open air. This instrument is referred to as a ‘plate spectrometer’ as the thickness of the spectrometer is adjusted by adding or removing aluminum plates. This spectrometer was assembled and then characterized at the Idaho Accelerator Center (IAC) with three different beam energies and with one beam energy at the University of Maryland Radiation Facilities. The plate spectrometer was able to match the median energies and provide a reasonable constraint to the beam distributions seen in the IAC magnetic spectrometer. Finally, in a separate experiment, the plate spectrometer was also seen to agree with a dosimetry characterization of the beam at the University of Maryland Radiation Facilities and improved upon the uncertainties of this measurement.

43 PARTICLE ACCELERATORS↗

Irradiation performance of a U-7Mo in Al-Si matrix dispersion full-size fuel plate assembly

The Korea Atomic Energy Research Institute (KAERI) is leading the Ki-Jang Research Reactor (KJRR) project with the intent to develop a new reactor for medical isotope production and other nuclear research purposes. The KJRR core is designed to use high density fuel system where uranium alloyed with 7 wt% molybdenum (U-7Mo) particles are dispersed in a matrix of aluminum alloyed with 5 wt% silicon (Al-5Si) and clad in aluminum alloy 6061 (Al-6061) to form fuel plates. KAERI developed a fabrication facility to construct KJRR fuel assemblies and partnered with the Idaho National Laboratory (INL) to irradiate a full-size fuel assembly, with 21 total fuel plates, in the Advanced Test Reactor (ATR). Irradiation testing and subsequent Post Irradiation Exam (PIE) campaigns were performed successfully over a multi-year project. Monte Carlo neutronic calculations, coupling with a depletion code, were performed based on ATR’s as-run power history which showed that the highest power plate (plate 20) reached 83.1 % end-of-life (EOL) local burnup based on initial 235 U content. Additionally, finite element thermal modeling was performed based as-run power history which showed a beginning-of-life (BOL) peak local heat flux of 184 W/cm 2 . No anomalous fuel performance was observed during the irradiation and target test conditions were achieved. PIE showed favorable performance of the fuel assembly regarding all important phenomena. This paper describes the KJRR fuel assembly irradiation conditions and PIE data to support the conclusion that it performed well, without evidence of unexpected or problematic fuel performance, within an irradiation test designed to bound the KJRR design environment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modeling of transverse stimulated Raman scattering in KDP/DKDP in large-aperture plates suitable for polarization control

Transverse stimulated Raman scattering (TSRS) in potassium dihydrogen phosphate (KDP) and deuterated potassium dihydrogen phosphate (DKDP) plates for large-aperture, inertial confinement fusion (ICF)-class laser systems is a well-recognized limitation giving rise to parasitic energy conversion and laser-induced damage. The onset of TSRS is manifested in plates exposed to the ultraviolet section of the beam. TSRS amplification is a coherent process that grows exponentially and is distributed nonuniformly in the crystal and at the crystal surfaces. To understand the growth and spatial distribution of TSRS energy in various configurations, a modeling approach has been developed to simulate the operational conditions relevant to ICF-class laser systems. Specific aspects explored in this work include (i) the behavior of TSRS in large-aperture crystal plates suitable for third-harmonic generation and use as wave plates for polarization control in current-generation ICF-class laser system configurations; (ii) methods, and their limitations, of TSRS suppression and (iii) optimal geometries to guide future designs.

47 OTHER INSTRUMENTATION↗

Electronic measurement of microchannel plate pulse height distributions

Microchannel plates are a central component of the x-ray framing cameras used as analog imagers in many plasma experiment diagnostic systems. The microchannel plate serves as an amplifying element, increasing the electronic signal from incident radiation by factors of 10{sup 3}-10{sup 5}, with a broad pulse-height distribution. Seeking to optimize the photon-to-electron conversion efficiency and noise distribution of x-ray cameras, we will characterize the pulse-height distribution of the electron output from a single microchannel plate. Replacing the framing camera's phosphor-coated fiber optic screen with a charge-collection plate and coupling to a low-noise multichannel analyzer, we quantified the distribution in the total charge generated per photon event. The electronically measured pulse height distribution is used to estimate the signal-to-noise ratio of radiographic images from framing cameras.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dependence of ion beam current on position of mobile plate tuner in multi-frequencies microwaves electron cyclotron resonance ion source

We are constructing a tandem-type electron cyclotron resonance ion source (ECRIS). The first stage of this can supply 2.45 GHz and 11-13 GHz microwaves to plasma chamber individually and simultaneously. We optimize the beam current I{sub FC} by the mobile plate tuner. The I{sub FC} is affected by the position of the mobile plate tuner in the chamber as like a circular cavity resonator. We aim to clarify the relation between the I{sub FC} and the ion saturation current in the ECRIS against the position of the mobile plate tuner. We obtained the result that the variation of the plasma density contributes largely to the variation of the I{sub FC} when we change the position of the mobile plate tuner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental investigation on focusing characteristics of a He-Ne laser using circular Fresnel zone plate for high-precision alignment of linear accelerators

We experimentally investigate the focusing characteristics of a He-Ne laser at the focal region for the high-precision alignment of long-distance linear accelerators using a circular Fresnel zone plate. The laser wave passing through the Fresnel zone plate having a focal length of 66.7 m propagates for a 268-m-long distance at atmospheric pressure. A new laser-based alignment system using Fresnel zone plates as the alignment targets is discussed. The transverse displacement of the focused spot of the laser is measured as a function of the displacement of the target by a detector installed at the focal point. Systematic studies on the focusing characteristics and alignment precision have been successfully conducted in this experiment. The experimental results are in good agreement with theoretical calculations, and the alignment precision of the target is determined to be less than {+-}30 {mu}m. In this study, we perform a detailed experimental investigation on the laser propagation and focusing characteristics using the circular Fresnel zone plate at the focal region along with theoretical calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A nitrogen doped low-dislocation density free-standing single crystal diamond plate fabricated by a lift-off process

A nitrogen-doped single crystal diamond plate with a low dislocation density is fabricated by chemical vapor deposition (CVD) from a high pressure high temperature synthetic type IIa seed substrate by ion implantation and lift-off processes. To avoid sub-surface damage, the seed surface was subjected to deep ion beam etching. In addition, we introduced a nitrogen flow during the CVD step to grow low-strain diamond at a relatively high growth rate. This resulted in a plate with low birefringence and a dislocation density as low as 400 cm{sup −2}, which is the lowest reported value for a lift-off plate. Reproducing this lift-off process may allow mass-production of single crystal CVD diamond plates with low dislocation density and consistent quality.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Damage imaging in a laminated composite plate using an air-coupled time reversal mirror

We demonstrate the possibility of selectively imaging the features of a barely visible impact damage in a laminated composite plate by using an air-coupled time reversal mirror. The mirror consists of a number of piezoelectric transducers affixed to wedges of power law profiles, which act as unconventional matching layers. The transducers are enclosed in a hollow reverberant cavity with an opening to allow progressive emission of the ultrasonic wave field towards the composite plate. The principle of time reversal is used to focus elastic waves at each point of a scanning grid spanning the surface of the plate, thus allowing localized inspection at each of these points. The proposed device and signal processing removes the need to be in direct contact with the plate and reveals the same features as vibrothermography and more features than a C-scan. More importantly, this device can decouple the features of the defect according to their orientation, by selectively focusing vector components of motion into the object, through air. For instance, a delamination can be imaged in one experiment using out-of-plane focusing, whereas a crack can be imaged in a separate experiment using in-plane focusing. As a result, this capability, inherited from the principle of time reversal, cannot be found in conventional air-coupled transducers.

36 MATERIALS SCIENCE↗

Air-coupled method to investigate the lowest-order antisymmetric Lamb mode in stubbed and air-drilled phononic plates

In this work, we applied a robust and fully air-coupled method to investigate the propagation of the lowest-order antisymmetric Lamb (A{sub 0}) mode in both a stubbed and an air-drilled phononic-crystal (PC) plate. By measuring simply the radiative acoustic waves of A{sub 0} mode close to the plate surface, we observed the band gaps for the stubbed PC plate caused by either the local resonance or the Bragg scattering, in frequency ranges in good agreement with theoretical predictions. We measured then the complete band gap of A{sub 0} mode for the air-drilled PC plate, in good agreement with the band structures. Finally, we compared the measurements made using the air-coupled method with those obtained by the laser ultrasonic technique.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Image-plate sensitivity to x rays at 2 to 60 keV

The sensitivity of Fuji SR and MS image plates (IPs) used in x-ray spectrometers on OMEGA and the National Ignition Facility has been measured using two techniques. A set of radioisotopes has been used to constrain image-plate sensitivity between 6 and 60 keV, while a Manson source has been used to expose image plates to x rays at energies between 1.5 and 8 keV. These data have shown variation in sensitivity on the order of 5% for a given IP type and scanner settings. The radioisotope technique has also been used to assess IP fading properties for MS-type plates over long times. IP sensitivity as a function of scanner settings and pixel size has been systematically examined, showing variations of up to a factor of 2 depending on IP type. Furthermore cross-calibration of IP scanners at different facilities is necessary to produce a consistent absolute sensitivity curve spanning the energy range of 2 to 60 keV.

47 OTHER INSTRUMENTATION↗

Multi-plate interceptive electron beam energy diagnostic—Implementation and validation

A previous publication [P. D. McChesney, “Multi-plate interceptive electron beam energy diagnostic—Theoretical design,” AIP Adv. (submitted)] reported a new interceptive electron beam kinetic energy measurement technique based on the beam penetration depth within a stack of conductive plates and gave results on the theoretical design of such a device. This paper expands on this and gives further results on the actual implementation of the diagnostic. The device geometry and measurement electronics system are described in detail. A prototype version of the multi-plate diagnostic was fabricated and tested using an electron linear accelerator at the Idaho Accelerator Center (IAC). A high-precision magnetic spectrometer system was designed and built for the purpose of validating the multi-plate diagnostic’s energy measurement capabilities. It was found that the diagnostic provides electron beam energy estimates that are accurate to better than the 10% level.

43 PARTICLE ACCELERATORS↗

Numerical Simulations of Flow-Induced Deflections in MITR LEU Fuel Plate Due to Channel Size Disparity

The hydromechanical stability of the fuel plates in parallel coolant channels of a Materials Testing Reactor (MTR) fuel element design is of great importance to the safety of research and test reactors. Previous analytical, experimental, and numerical efforts focused on parallel channels with the same or similar size; also, in the prior numerical simulations, the fuel plate was often assumed to be perfectly flat. This work presents the results of a fluid-structure interaction simulation performed to evaluate the flow-induced deflections of the fuel plates in the low-enriched uranium (LEU, <20 wt% 235 U) fuel element design for the conversion (from highly enriched uranium) of the Massachusetts Institute of Technology Reactor (MITR-II, also referred to as MITR). Various manufacturing and assembly tolerances of the MITR LEU elements are considered in the analysis, and the effects of channel size disparity, nonideal plate shape, and flow rate uncertainty are investigated. Results show that, for all cases analyzed, the deflection occurs toward the larger channel, and the change in any channel stripe remains small (less than 0.021 mm) compared to fabrication tolerances. In addition to simulation work, a hydraulic performance test of the MITR LEU fuel element is currently planned to support conversion to the use of LEU fuel.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Influence of Microstructure on the Absorption of Tritium into Gold-Plated 316 Stainless Steel

The interaction of tritium with metal surfaces is the initial step in the overall absorption of tritium by the substrate metal. As a result, limiting the adsorption of tritium to the surface may effectively reduce the quantity of tritium absorbed by a metal when it is in contact with tritium gas. To limit tritium adsorption, many tritium users electroplate gold onto the substrate metal. The gold layer is expected to reduce tritium adsorption, and subsequently absorption, by reducing water adsorption. The present work shows a comparison between tritium inventories in nonplated 316 stainless steel to the inventories in 316 stainless-steel samples electroplated with gold by various commercial vendors and laboratories. Of the various gold-plated samples, only one type of plating shows ~25% reduction in tritium inventory, relative to non-plated steel samples. The degree of tritium absorption appears to be significantly influenced by the porosity, texture, and completeness of the gold layer. Incomplete and/or porous layers lead to increased absorption, while gold layers with smaller surface features lead to similar tritium inventories as non-plated samples. Furthermore, reduced tritium absorption was observed only for complete gold layers with small surface features.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗