Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical data processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Machine Learning-Based Anomaly Detection for PMT Data Quality Monitoring in the SBN and DUNE

Maintaining high-quality detector data is essential for achieving the scientific objectives of the Short-Baseline Neutrino (SBN) Program at Fermilab. Current data quality monitoring (DQM) procedures rely primarily on threshold-based metrics and manual inspection of detector monitoring plots, making the detection of subtle or gradually developing anomalies both time-consuming and dependent on expert interpretation. This project developed and evaluated a machine-learning workflow for automatically identifying anomalous photomultiplier tube (PMT) channels in the Short-Baseline Near Detector (SBND) using optical-hit amplitude data. A Python-based analysis program was developed to process ROOT files, extract statistical features describing individual PMT amplitude distributions, and generate feature vectors for anomaly detection. These features were used to train an Isolation Forest model using data representing normal detector operation. The trained model was subsequently applied to independent detector runs to identify channels exhibiting statistically unusual behavior relative to the learned reference response. To support expert interpretation, the workflow generated complementary diagnostic products, including anomaly score distributions, normalized amplitude comparisons, decision-tree visualizations, and principal component analysis (PCA) projections. This project demonstrated the feasibility of integrating unsupervised machine learning into detector data-quality monitoring and developed a complete workflow for automated PMT performance assessment to aid expert-driven review. Beyond its technical contributions, the VFP appointment fostered a research collaboration between Aurora University and Fermilab and provided direct workforce development benefits by training the visiting faculty member in detector-scale machine-learning methods that are now being incorporated into undergraduate coursework and research. The methodology developed here provides a foundation for future applications to ProtoDUNE and other liquid argon time projection chamber (LArTPC) detectors, contributing to ongoing efforts to improve detector reliability, reduce manual monitoring requirements, and enable scalable data quality monitoring for future large-scale neutrino experiments, including the Deep Underground Neutrino Experiment (DUNE).

Colón Santana, Juan A. [Unlisted, US, IL]↗

EPCAPE-PT-LANL Measurements: Single Particle Soot Photometer

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Single Particle Soot Photometer (Droplet Measurements Technology) Data Notes: Contact us if you want additional data products from this instrument. Reported data is the black carbon (rBC) number and mass concentration with diagnostic flags. The SP2 measures incandescence from particles that is induced with a 1064 Nd-YAG laser. Particles that absorb the laser energy and then emit radiation is assumed to contain black carbon. The amount of intensity of radiation is related to the mass of absorbing material in the particle. Here, we calibrate the incandescence intensity to size selected Regal Black (Cabot) nebulized from solution. Data provided for the EPCAPE campaign used the combined broadband high-gain + low-gain channels (BHBL). Each channel has a lower threshold of detection equivalent to 2-s of the respective channel noise. Thresholding has been applied to select between the high-gain and low-gain channels. The detection limit is 80-540 nm (Deq) or 0.36- 55 fg. It is assumed that rBC is the only aerosol type that is in significant concentration in the sampled atmosphere that absorbs the laser energy. Particle data are integrated over 10 second windows to calculate a rBC number and mass concentration. QC/QA: • Diagnostic flags that impacted measured concentration: - Sample, Sheath, and Purge Flow Rates: Despite observing fluctuations in all flows, the rBC detection and mass quantification are generally observed to be stable, although large changes in sample flow rate did impact detection efficiency. A flag was implemented for sample flow deviations >12 cm3/min from the set point averaged over 30 seconds - Laser Power: Detection efficiency decreases with laser power and deviations in laser power also affect mass quantification. Flag for laser power is set for deviations in laser current from the set value >5 mA. - Primary Detector Threshold: Primary thresholding is the signal value which determines whether a “particle” is recorded. Thresholding errors occur when the threshold value is too HIGH and real particles are ignored. • Several periods without data: - 16-18 Nov: Ultra Zero Air generator failure, flows deviated significantly from set points. rBC # conc recovered but questionable. - 20-21 Nov: Offline for calibrations for several hours each day. - 25-27 Nov: Data is missing. - 30 Nov: Power outage 3 Dec: SP2 hard-drive full. - 3 Dec: Power Outage Header: - BHBL_NumbConc[#/cc]: Refers to the number concentration of refractory black carbon (rBC) measured from combined broadband high-gain and low-gain channels, expressed in particles per cubic centimeter. - BHBL_BCMass_Conc[ug/m3]: Refers to the mass concentration of refractory black carbon (rBC) measured from combined broadband high-gain and low-gain channels, expressed in micrograms per cubic meter. - NoData_Flag[bool]: A boolean flag that indicates whether no data was recorded during a measurement. - NoBC_Flag[bool]: A boolean flag indicating whether no black carbon particles were recorded during the measurement. - Laser_Flag[bool]: A boolean flag indicating deviations in laser current during the measurement. - SampleFlow_Flag[bool]: A boolean flag indicating deviations from the set sample flow rate during the measurement. - PrimThresh_Flag[bool]: A boolean flag indicating deviations from the set primary threshold during the measurement, potentially ignoring real particles. - Manual_Flag[bool]: A boolean flag indicating manual intervention or adjustments during the measurement. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active or inactive during the measurement.

54 ENVIRONMENTAL SCIENCES↗

EPCAPE-PT-LANL Measurements: Wideband Integrated Bioaerosol Sensor

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Wideband Integrated Bioaerosol Sensor (Droplet Measurements Technology) Data Notes: The WIBS is an online single-particle measurement that detects FBAPs (within a size range of 0.5 - 30 microns in diameter) based on the excitation and emission wavelengths of the individual particles. Using two xenon lamps, the WIBS excites FBAPs at 280 nm and 370 nm. Their emission is detected across two wavebands of 310-400 nm and 420-650 nm. We classified the FBAPs into seven different categories (A, B, C, AB, BC, AC, and ABC) using the classification scheme in Perring et. al. (2015) [1]. Averaged number concentration of FBAPs (total and by category) and particles that non-fluorescent bioaerosols particles (NFBAPs). In separate files, we also present one-minute-averaged size distributions and the asymmetry factor (AF, a surrogate for shape) of all FBAPs and NFBAPs. The logarithmic bin width of the size bins are the same as the average bin width of the AOS's optical particle counter (OPC, Grimm) for the range of sizes in which they overlap (26 bins from 0.5 - 30 microns). AF of the particles ranges from 0-100 and is divided into five bins with a linear spacing at increments of 20. The smallest AF bin represents more spherical particles while the largest bin represents more rod-shaped particles. [1] Perring, A. E., et al. (2015), Airborne observations of regional variation in fluorescent aerosol across the United States, J. Geophys. Res. Atmos., 120, 1153–1170, doi:10.1002/2014JD022495. Abstract and description of the campaign can be found here : https://www.arm.gov/research/campaigns/amf2023epcape-pt-lanl. Files data_10min_WIBS_AFDist.csv Header: - FBAP_AFDist[/cm3]_Bin_1 to Bin_5: Concentration of fluorescent bioaerosol particles in the each of 5 AF bins, measured in particles per cubic centimeter. Each bin represents a specific range of particle AF, capturing the shapes of FBAPs detected during the measurement. - NFBAP_AFDist[/cm3]_Bin_1 to Bin_5: Concentration of non-fluorescent bioaerosol particles in the each of 5 AF bins, measured in particles per cubic centimeter. Each bin represents a specific range of particle AF, capturing the shapes of NFBAPs detected during the measurement. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement. AF Bins: • Bin 1: 0 – 20 [unitless] • Bin 2: 21 – 40 [unitless] • Bin 3: 41 – 60 [unitless] • Bin 4: 61 – 80 [unitless] • Bin 5: 81 – 100 [unitless] Files data_10min_WIBS_Conc.csv Header: - NumberConcentrationA[/cm3]: Number concentration of bioaerosol particles detected by fluorescence channel A, measured in particles per cubic centimeter. - NumberConcentrationB[/cm3]: Number concentration of bioaerosol particles detected by fluorescence channel B, measured in particles per cubic centimeter. - NumberConcentrationC[/cm3]: Number concentration of bioaerosol particles detected by fluorescence channel C, measured in particles per cubic centimeter. - NumberConcentrationAB[/cm3]: Combined number concentration of bioaerosol particles detected by both fluorescence channels A and B, measured in particles per cubic centimeter. - NumberConcentrationBC[/cm3]: Combined number concentration of bioaerosol particles detected by both fluorescence channels B and C, measured in particles per cubic centimeter. - NumberConcentrationAC[/cm3]: Combined number concentration of bioaerosol particles detected by both fluorescence channels A and C, measured in particles per cubic centimeter. - NumberConcentrationABC[/cm3]: Combined number concentration of bioaerosol particles detected by all three fluorescence channels A, B, and C, measured in particles per cubic centimeter. - NumberConcentrationNFBAP[/cm3]: Number concentration of non-fluorescent bioaerosol particles, measured in particles per cubic centimeter. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement. Files data_10min_WIBS_SizeDist.csv Header: - FBAP_SizeDist[/cm3]_Bin_1 to FBAP_SizeDist[/cm3]_Bin_26: Number concentrations of FBAP in each of 26 size bins, measured in particles per cubic centimeter. Each bin represents a specific range of particle sizes, capturing the size distribution of FBAPs detected during the measurement. - NFBAP_SizeDist[/cm3]_Bin_1 to NFBAP_SizeDist[/cm3]_Bin_26: Number concentrations of NFBAP in each of 26 size bins, measured in particles per cubic centimeter. Similar to FBAP, each bin covers a specific range of particle sizes, detailing the size distribution of NFBAPs detected. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement. Size Bins: • Bin 1: 0.48 to 0.57 μm • Bin 2: 0.57 to 0.67 μm • Bin 3: 0.67 to 0.79 μm • Bin 4: 0.79 to 0.93 μm • Bin 5: 0.93 to 1.1 μm • Bin 6: 1.1 to 1.29 μm • Bin 7: 1.29 to 1.52 μm • Bin 8: 1.52 to 1.8 μm • Bin 9: 1.8 to 2.11 μm • Bin 10: 2.11 to 2.5 μm • Bin 11: 2.5 to 2.94 μm • Bin 12: 2.94 to 3.46 μm • Bin 13: 3.46 to 4.08 μm • Bin 14: 4.08 to 4.81 μm • Bin 15: 4.81 to 5.67 μm • Bin 16: 5.67 to 6.68 μm • Bin 17: 6.68 to 7.88 μm • Bin 18: 7.88 to 9.29 μm • Bin 19: 9.29 to 10.96 μm • Bin 20: 10.96 to 12.92 μm • Bin 21: 12.92 to 15.23 μm • Bin 22: 15.23 to 17.96 μm • Bin 23: 17.96 to 21.17 μm • Bin 24: 21.17 to 24.96 μm • Bin 25: 24.96 to 29.43 μm • Bin 26: 29.43 to 34.70 μm

54 ENVIRONMENTAL SCIENCES↗

Laser interferometric measurement of ion electrode shape and charge exchange erosion

A projected fringe profilometry system was applied to surface contour measurements of an accelerator electrode from an ion thrustor. The system permitted noncontact, nondestructive evaluation of the fine and gross structure of the electrode. A 3-D surface map of a dished electrode was generated without altering the electrode surface. The same system was used to examine charge exchange erosion pits near the periphery of the electrode to determine the depth, location, and volume of material lost. This electro-optical measurement system allowed rapid, nondestructive, digital data acquisition coupled with automated computer data processing. In addition, variable sensitivity allowed both coarse and fine measurements of objects having various surface finishes.

Macrae, Gregory S.↗

The goldstone real-time connected element interferometer

Connected element interferometry (CEI) is a technique of observing a celestial radio source at two spatially separated antennas and then interfering the received signals to extract the relative phase of the signal at the two antennas. The high precision of the resulting phase delay data type can provide an accurate determination of the angular position of the radio source relative to the baseline vector between the two stations. This article describes a recently developed connected element interferometer on a 21-km baseline between two antennas at the Deep Space Network's Goldstone, California, tracking complex. Fiber-optic links are used to transmit the data to a common site for processing. The system incorporates a real-time correlator to process these data in real time. The architecture of the system is described, and observational data are presented to characterize the potential performance of such a system. The real-time processing capability offers potential advantages in terms of increased reliability and improved delivery of navigational data for time-critical operations. Angular accuracies of 50-100 nrad are achievable on this baseline.

Edwards, C., Jr.↗

Desirable features of an infrared imaging system for aerodynamic research

Advantage of non-intrusiveness, capability for field measurement, and increased availability of IR imaging systems have resulted in their wider use for aerodynamic research. However, certain difficulties persist while using currently available systems for such applications. A critical evaluation of the IR imaging systems is presented on the basis of the state-of-the-art of IR imaging technology and experiences in wind tunnel and flight testing at NASA's Langley Research Center. The requirements for using IR thermography as a measurement tool in aerodynamic research are examined in terms of range, sensitivity, and accuracy of temperature measurement, temporal and spatial resolution, and features of target. Deficiencies of present IR imaging systems are identified, and user precautions to avoid such problems by proper selection and operation of these units are suggested. Different aspects of imager performance such as imager optics, video capabilities, and environmental tolerance are discussed. Electronic data recording and image processing hardware and software requirements are evaluated. Slit response tests and spatial resolution are discussed with the objective of obtaining reliable, accurate, and meaningful information from IR thermography measurements for aerodynamic studies.

Wright, Robert E., Jr.↗

The Fundamental Physical Processes Producing and Controlling Stellar Coronal/ Transition-Region/Chromospheric Activity and Structure

Our LTSA grant supports a long-term collaborative investigation of stellar activity. The project involves current NASA spacecraft and supporting ground-based telescopes, will make use of future missions, and utilizes the extensive archives of IUE, ROSAT, HST, and EUVE. Our interests include observational work (with a nonnegligible groundbased component); specialized processing techniques for imaging and spectral data; and semiempirical modeling, ranging from optically-thin emission measure studies to simulations of optically-thick resonance lines. Collaborations with our cool-star colleagues here in Boulder (at JILA and the High Altitude Observatory) provide access to even broader expertise, particularly on the solar corona, convection, and magnetohydrodynamic phenomena (including "dynamo" theories). The broad-brush of our investigation include the following: (1) where do coronae occur in the Hertzsprung-Russell diagram? (2) the winds of coronal stars: hot, cool, or both? (3) age, activity, rotation relations; (4) atmospheric inhomogeneities; and (5) heating mechanisms, subcoronal flows and flares. Our observation task has been to map the global properties of chromospheres and coronae in the H-R diagram and conduct detailed studies of key objects.

Ayres, Thomas R.↗

Scientific Applications of Optical Instruments to Materials Research

Microgravity is a unique environment for materials and biotechnology processing. Microgravity minimizes or eliminates some of the effects that occur in one g. This can lead to the production of new materials or crystal structures. It is important to understand the processes that create these new materials. Thus, experiments are designed so that optical data collection can take place during the formation of the material. This presentation will discuss scientific application of optical instruments at MSFC. These instruments include a near-field scanning optical microscope, a miniaturized holographic system, and a phase-shifting interferometer.

Witherow, William K.↗

Analytical and Experimental Characterization of a Linear-Array Thermopile Scanning Radiometer for Geo-Synchronous Earth Radiation Budget Applications

The Thermal Radiation Group, a laboratory in the department of Mechanical Engineering at Virginia Polytechnic Institute and State University, is currently working towards the development of a new technology for cavity-based radiometers. The radiometer consists of a 256-element linear-array thermopile detector mounted on the wall of a mirrored wedgeshaped cavity. The objective of this research is to provide analytical and experimental characterization of the proposed radiometer. A dynamic end-to-end opto-electrothermal model is developed to simulate the performance of the radiometer. Experimental results for prototype thermopile detectors are included. Also presented is the concept of the discrete Green's function to characterize the optical scattering of radiant energy in the cavity, along with a data-processing algorithm to correct for the scattering. Finally, a parametric study of the sensitivity of the discrete Green's function to uncertainties in the surface properties of the cavity is presented.

Sorensen, Ira J.↗

Lidar Observations of Tropospheric Aerosols Over Northeastern South Africa During the ARREX and SAFARI-2000 Dry Season Experiments

During the ARREX-1999 and SAFARI-2000 Dry Season experiments a micropulse lidar (523 nm) instrument was operated at the Skukuza Airport in northeastern South Africa. The Mar was collocated with a diverse array of passive radiometric equipment. For SAFARI-2000 the processed Mar data yields a daytime time-series of layer mean/derived aerosol optical properties, including extinction-to-backscatter ratios and vertical extinction cross-section profile. Combined with 523 run aerosol optical depth and spectral Angstrom exponent calculations from available CIMEL sun-photometer data and normalized broadband flux measurements the temporal evolution of the near surface aerosol layer optical properties is analyzed for climatological trends. For the densest smoke/haze events the extinction-to-backscatter ratio is found to be between 60-80/sr, and corresponding Angstrom exponent calculations near and above 1.75. The optical characteristics of an evolving smoke event from SAFARI-2000 are extensively detailed. The advecting smoke was embedded within two distinct stratified thermodynamic layers, causing the particulate mass to advect over the instrument array in an incoherent manner on the afternoon of its occurrence. Surface broadband flux forcing due to the smoke is calculated, as is the evolution in the vertical aerosol extinction profile as measured by the Han Finally, observations of persistent elevated aerosol during ARREX-1999 are presented and discussed. The lack of corroborating observations the following year makes these observation; both unique and noteworthy in the scope of regional aerosol transport over southern Africa.

Campbell, James R.↗

The Micro-Pulse Lidar Network (MPL-Net)

In the early 1990s, the first small, eye-safe, and autonomous lidar system was developed, the Micro-pulse Lidar (MPL). The MPL has proven to be useful in the field because it can be automated, runs continuously (day and night), is eye-safe, can easily be transported and set up, and has a small field-of-view which limits multiple scattering concerns. The MPL acquires signal profiles of backscattered laser light from aerosols and clouds. The signals are analyzed to yield multiple layer heights, optical depths of each layer, average extinction-to-backscatter ratio of each layer, and profiles of extinction in each layer. The MPL has been used in a wide variety of field studies over the past 10 years, leading to nearly 20 papers and many conference presentations. In 2000, a new project using MPL systems was started at NASA Goddard Space Flight Center. The MPL-Net project is currently working to establish a worldwide network of MPL systems, all co-located with NASA's AERONET sunphotometers for joint measurements of optical depth and sky radiance. Automated processing algorithms have been developed to produce data products on a next day basis for all sites and some field experiments. Initial results from the first several sites are shown, along with aerosol data collected during several major field campaigns. Measurements of the aerosol extinction-to-backscatter ratio at several different geographic regions, and for various aerosol types are shown. This information is used to improve the construction of look up tables of the ratio, needed to process aerosol profiles acquired with satellite based lidars.

Welton, Ellsworth J.↗

Total Ozone from the Ozone Monitoring System (OMI) using TOMS and DOAS Methods

The Ozone Monitoring Instrument (OMI) is the Dutch-Finnish contribution to NASA's EOS-Aura satellite scheduled for launch in January 2004. OMI is an imaging spectrometer that will measure the back-scattered Solar radiance in the wavelength range of 270 to 500 nm. The instrument provides near global coverage in one day with a spatial resolution of 13x24 square kilometers. OMI is a new instrument, with a heritage from TOMS, SBW, GOME, GOMOS and SCIAMACHY. OMI'S unique capabilities for measuring important trace gases and aerosols with a small footprint and daily global coverage, in conjunction with the other Aura instruments, will make a major contribution to our understanding of stratospheric and tropospheric chemistry and climate change. OMI will provide data continuity with the 23-year ozone record of TOMS. There are three ozone products planned for OMI: total column ozone, ozone profile and tropospheric column ozone. We are developing two different algorithms for total column ozone: one similar to the algorithm currently being used to process the TOMS data, and the other an improved version of the differential optical absorption spectroscopy (DOAS) method, which has been applied to GOME and SCIAMACHY data. The main reasons for starting with two algorithms for total ozone have to do with heritage and past experience; our long-term goal is to combine the two to develop a more accurate and reliable total ozone product for OMI. We will compare the performance of these two algorithms by applying both of them to the GOME data. We will examine where and how the results differ, and use the extensive TOMS-Dobson comparison studies to assess the performance of the DOAS algorithm.

Veefkind, J. P.↗

Maritime Aerosol Network as a Component of AERONET - First Results and Comparison with Global Aerosol Models and Satellite Retrievals

The Maritime Aerosol Network (MAN) has been collecting data over the oceans since November 2006. Over 80 cruises were completed through early 2010 with deployments continuing. Measurement areas included various parts of the Atlantic Ocean, the Northern and Southern Pacific Ocean, the South Indian Ocean, the Southern Ocean, the Arctic Ocean and inland seas. MAN deploys Microtops handheld sunphotometers and utilizes a calibration procedure and data processing traceable to AERONET. Data collection included areas that previously had no aerosol optical depth (AOD) coverage at all, particularly vast areas of the Southern Ocean. The MAN data archive provides a valuable resource for aerosol studies in maritime environments. In the current paper we present results of AOD measurements over the oceans, and make a comparison with satellite AOD retrievals and model simulations.

Smirnov, A.↗

Window obscuration sensors for mobile gas and chemical imaging cameras

An infrared (IR) imaging system for determining a concentration of a target species in an object is disclosed. The imaging system can include an optical system including a focal plane array (FPA) unit behind an optical window. The optical system can have components defining at least two optical channels thereof, said at least two optical channels being spatially and spectrally different from one another. Each of the at least two optical channels can be positioned to transfer IR radiation incident on the optical system towards the optical FPA. The system can include a processing unit containing a processor that can be configured to acquire multispectral optical data representing said target species from the IR radiation received at the optical FPA. One or more of the optical channels may be used in detecting objects on or near the optical window, to avoid false detections of said target species.

Mallery, Ryan↗

Window obscuration sensors for mobile gas and chemical imaging cameras

An infrared (IR) imaging system for determining a concentration of a target species in an object is disclosed. The imaging system can include an optical system including a focal plane array (FPA) unit behind an optical window. The optical system can have components defining at least two optical channels thereof, said at least two optical channels being spatially and spectrally different from one another. Each of the at least two optical channels can be positioned to transfer IR radiation incident on the optical system towards the optical FPA. The system can include a processing unit containing a processor that can be configured to acquire multispectral optical data representing said target species from the IR radiation received at the optical FPA. One or more of the optical channels may be used in detecting objects on or near the optical window, to avoid false detections of said target species.

Mallery, Ryan↗

Window obscuration sensors for mobile gas and chemical imaging cameras

An infrared (IR) imaging system for determining a concentration of a target species in an object is disclosed. The imaging system can include an optical system including a focal plane array (FPA) unit behind an optical window. The optical system can have components defining at least two optical channels thereof, said at least two optical channels being spatially and spectrally different from one another. Each of the at least two optical channels can be positioned to transfer IR radiation incident on the optical system towards the optical FPA. The system can include a processing unit containing a processor that can be configured to acquire multispectral optical data representing said target species from the IR radiation received at the optical FPA. One or more of the optical channels may be used in detecting objects on or near the optical window, to avoid false detections of said target species.

Mallery, Ryan↗

Window obscuration sensors for mobile gas and chemical imaging cameras

An infrared (IR) imaging system for determining a concentration of a target species in an object is disclosed. The imaging system can include an optical system including a focal plane array (FPA) unit behind an optical window. The optical system can have components defining at least two optical channels thereof, said at least two optical channels being spatially and spectrally different from one another. Each of the at least two optical channels can be positioned to transfer IR radiation incident on the optical system towards the optical FPA. The system can include a processing unit containing a processor that can be configured to acquire multispectral optical data representing said target species from the IR radiation received at the optical FPA. One or more of the optical channels may be used in detecting objects on or near the optical window, to avoid false detections of said target species.

Mallery, Ryan↗

Window obscuration sensors for mobile gas and chemical imaging cameras

An infrared (IR) imaging system for determining a concentration of a target species in an object is disclosed. The imaging system can include an optical system including a focal plane array (FPA) unit behind an optical window. The optical system can have components defining at least two optical channels thereof, said at least two optical channels being spatially and spectrally different from one another. Each of the at least two optical channels can be positioned to transfer IR radiation incident on the optical system towards the optical FPA. The system can include a processing unit containing a processor that can be configured to acquire multispectral optical data representing said target species from the IR radiation received at the optical FPA. One or more of the optical channels may be used in detecting objects on or near the optical window, to avoid false detections of said target species.

Mallery, Ryan↗