Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OPERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

REDUCTION OF CONSTRAINTS FOR COUPLED OPERATIONS

The homogeneity constraint was implemented in the Defense Waste Processing Facility (DWPF) Product Composition Control System (PCCS) to help ensure that the current durability models would be applicable to the glass compositions being processed during DWPF operations. While the homogeneity constraint is typically an issue at lower waste loadings (WLs), it may impact the operating windows for DWPF operations, where the glass forming systems may be limited to lower waste loadings based on fissile or heat load limits. In the sludge batch 1b (SB1b) variability study, application of the homogeneity constraint at the measurement acceptability region (MAR) limit eliminated much of the potential operating window for DWPF. As a result, Edwards and Brown developed criteria that allowed DWPF to relax the homogeneity constraint from the MAR to the property acceptance region (PAR) criterion, which opened up the operating window for DWPF operations. These criteria are defined as: (1) use the alumina constraint as currently implemented in PCCS (Al{sub 2}O{sub 3} {ge} 3 wt%) and add a sum of alkali constraint with an upper limit of 19.3 wt% ({Sigma}M{sub 2}O < 19.3 wt%), or (2) adjust the lower limit on the Al{sub 2}O{sub 3} constraint to 4 wt% (Al{sub 2}O{sub 3} {ge} 4 wt%). Herman et al. previously demonstrated that these criteria could be used to replace the homogeneity constraint for future sludge-only batches. The compositional region encompassing coupled operations flowsheets could not be bounded as these flowsheets were unknown at the time. With the initiation of coupled operations at DWPF in 2008, the need to revisit the homogeneity constraint was realized. This constraint was specifically addressed through the variability study for SB5 where it was shown that the homogeneity constraint could be ignored if the alumina and alkali constraints were imposed. Additional benefit could be gained if the homogeneity constraint could be replaced by the Al{sub 2}O{sub 3} and sum of alkali constraint for future coupled operations processing based on projections from Revision 14 of the High Level Waste (HLW) System Plan. As with the first phase of testing for sludge-only operations, replacement of the homogeneity constraint with the alumina and sum of alkali constraints will ensure acceptable product durability over the compositional region evaluated. Although these study glasses only provide limited data in a large compositional region, the approach and results are consistent with previous studies that challenged the homogeneity constraint for sludge-only operations. That is, minimal benefit is gained by imposing the homogeneity constraint if the other PCCS constraints are satisfied. The normalized boron releases of all of the glasses are well below the Environmental Assessment (EA) glass results, regardless of thermal history. Although one of the glasses had a normalized boron release of approximately 10 g/L and was not predictable, the glass is still considered acceptable. This particular glass has a low Al{sub 2}O{sub 3} concentration, which may have attributed to the anomalous behavior. Given that poor durability has been previously observed in other glasses with low Al{sub 2}O{sub 3} and Fe{sub 2}O{sub 3} concentrations, including the sludge-only reduction of constraints study, further investigations appear to be warranted. Based on the results of this study, it is recommended that the homogeneity constraint (in its entirety with the associated low frit/high frit constraints) be eliminated for coupled operations as defined by Revision 14 of the HLW System Plan with up to 2 wt% TiO{sub 2}. The use of the alumina and sum of alkali constraints should be continued along with the variability study to determine the predictability of the current durability models and/or that the glasses are acceptable with respect to durability. The use of a variability study for each batch is consistent with the glass product control program and it will help to assess new streams or compositional changes. It is also recommended that the influence of alumina and alkali on durability be studied in greater detail. Limited data suggests that there may be a need to adjust the lower Al{sub 2}O{sub 3} limit and/or the upper alkali limit in order to prevent the fabrication of unacceptable glasses. An in-depth evaluation of all previous data as well as any new data would help to better define an alumina and alkali combination that would avoid potential phase separation and ensure glass durability.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Andra's strategy and approach for operational safety of French underground facility Cigeo - 15127

According to the French Act on radioactive waste of 28 June 2006, Andra shall design a reversible repository. In response to this demand, Andra is developing the industrial project namely 'Cigeo', a reversible geological disposal facility for HLW and ILW located in Meuse/Haute-Marne. The previous safety cases of 2005, 2009 and 2012 give a sound basis to assess Cigeo's safety both for the operational and post-closure periods. Regarding operational safety, in this new stage of the project, the challenging issues for the preparation of the safety case are the following: - To adapt the various regulatory frameworks (nuclear and non-nuclear) to the underground facility - To design the underground facility and handling equipment's to reduce at first risks in the underground facility as such radioactive particles release, gas explosion, fire and co-activity and limit their consequence. - To establish waste acceptance criteria to be fulfilled by waste producers in line with operational safety and design options. The objective of the paper is to present the experience of Andra in operation safety of the underground facility of Cigeo. Operational safety for Cigeo is assessed as much as possible according to the existing French regulations and guidance for nuclear facilities. Indeed, compared to existing nuclear facilities, a geological repository is a specific case due to the existence of underground facilities with particularities such as: - ventilation management in a large scale underground facility, - fire risk management. As an input for the industrial design of Cigeo for operation, Andra defined a fire guidance and a specific reference safety guidance, based on the adaptation of the French nuclear regulatory texts for and when feasible to mines and tunnels regulatory texts and on its own experience gained through safety operational reports since 2005 and their reviews by the Safety Authority. - underground co-activity of nuclear operation with construction works. According to the common 'defense-in depth' principle for nuclear facilities, these guidelines for the industrial design of Cigeo for operation consider the successive levels of defense of: - Preventing the risk and its spreading by design and construction; - Detecting incidents and early fighting by design and operation dispositions (detection and control systems, survey procedure); - Controlling incidents and limiting of their consequences by safeguarding systems, specific procedures. At that stage, design options for Cigeo constitute an adequate response to the operational safety functions and requirements: - Two levels of containment are set up: the first one is ensured by the waste package, the second one is ensured from the surface facility to the disposal vaults by the transfer cask during the transfer of waste packages in the disposal vaults by the disposal vault itself and a nuclear ventilation with HEPA filter; - Favorable options for fire risk prevention and mitigation: transport system minimizing heat load (cable car for the transfer from the surface, electric transfer engines), twin access tunnels to ease fire-fighting and evacuation...; - Permanent complete physical separation of nuclear zone and construction zone (including ventilation systems). In practice, operation safety assessment of Cigeo, designed following the aforesaid reference safety guidelines, follows a common risk analysis (internal aggressions such as auxiliary losses, chemical and toxic risks, fall or collision, fire, human factors and external aggressions such as earthquake, air traffic, flooding) with the following steps: - Identification of the major risks and the design basis scenarios that have to be considered for dimensioning of the installations and the safety devices; - On the basis of these different situations, those who will have to be quantified are identified; one or more representative and envelop situations are chosen in order to evaluate robustness of the installation. Quantitative evaluation of these situations permits to: - identify the consequences on man, environment and installation, and in particular to gain confidence in the maintaining of the safety functions; - identify or define the technic and/or organisational dispositions classified as 'important elements for protection' (IEP); - Situations beyond dimensioning permit to verify the robustness of the installation. They permit, on one hand to identify possible complementary material or organisational dispositions; on the other hand, to define the 'hard core' i.e. structures, systems and components that permit to maintain the confinement function of radioactive substance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Comparison of Pre‐Construction and Operational Wake Loss Estimates for Land‐Based Wind Plants

The overall bias between pre‐construction energy yield assessment (EYA) estimates of wind plant energy production and the achieved operational production is improving in the wind industry, but uncertainty remains high for individual wind plants. Wake effects within wind plants are one of the largest sources of energy loss considered in the EYA process, and previous work shows wake loss estimates to be a major source of disagreement among wind energy consultants who perform EYAs. To better understand the accuracy of wake loss predictions, we compare overall operational wake loss estimates based on supervisory control and data acquisition data to pre‐construction estimates provided by six wind energy consultants for five land‐based wind plants in North America. By augmenting existing approaches for quantifying operational wake losses, we estimate wake losses during the period of record for which operational data are available as well as the expected long‐term wake losses, based on historical reanalysis weather data, to which the EYA estimates are compared. To account for power variations at different turbine locations caused by terrain‐induced wind resource heterogeneity, we correct the operational wake loss estimates using predicted freestream wind speed variations from the Wind Systems Engineering Reynolds‐averaged Navier–Stokes (RANS) tool. We identify long‐term corrected operational wake losses between 1.9% and 6.4% for the five plants, with a mean loss of 4%. For the project deemed most acceptable for operational wake loss assessment, which is located in the simplest terrain and isolated from neighboring plants, the mean EYA wake loss estimate is within 0.7 percentage points of the operational value of 6.4%. For most of the remaining plants, results suggest that wake losses are generally overpredicted by 2.6–6.3 percentage points. However, operational wake losses may be underestimated for many of these projects because of spatial wind resource variations not captured by the RANS model, external wake effects that are unaccounted for in the estimation process, and wind plant blockage effects. To better understand factors that contribute to the observed wake losses, we investigate operational wake losses as a function of wind direction and wind speed. As expected, wake losses are generally concentrated near wind directions that are aligned with rows of closely spaced turbines and at below‐rated wind speeds; however, for some projects, the energy produced by the wind plant exceeds the estimated potential energy of the plant without wake interactions for certain wind directions and wind speeds, suggesting inaccurate assumptions in the wake loss estimation method for those plants. Lastly, we compare predicted and operational wake losses for individual wind turbines, finding that even when overall wake losses are predicted accurately, large uncertainty exists at the turbine level.

17 WIND ENERGY↗

Comprehensive Solutions for Integration of Solar Resources into Grid Operations

The need for proactive closed-loop integration of uncertainty information into system operations and probability-based controls is widely recognized, but rarely implemented in system operations. Proactive integration for this project means that the information concerning expected uncertainty ranges for net load and balancing requirements, including required balancing capacity, ramping and ramp duration characteristics, will be fed back into the generation commitment and dispatch algorithms to modify their performance so that potential shortages of these characteristics can be prevented. This basic, yet important, premise is the motivating factor for this project. The achieved project goal is to demonstrate the benefit of such a system. The project quantifies future uncertainties, predicts additional system balancing needs including the prediction intervals for capacity and ramping requirements of future dispatch intervals, evaluates the impacts of uncertainties on transmission including the risk of overloads and voltage problems, and explores opportunities for intra-hour generation adjustments helping to provide more flexibility for system operators. The resulting benefits culminate in more reliable grid operation in the face of increased system uncertainty and variability caused by solar power. The project identifies that solar power does not require special separate penetration level restrictions or penalization for its intermittency. Ultimately, the collective consideration of all sources of intermittency distributed over a wide area unified with the comprehensive evaluation of various elements of balancing process, i.e. capacity, ramping, and energy requirements, help system operators more robustly and effectively balance generation against load and interchange. This project showed that doing so can facilitate more solar and other renewable resources on the grid without compromising reliability and control performance. Efforts during the project included developing and integrating advanced probabilistic solar forecasts, including distributed PV forecasts, into closed –loop decision making processes. Additionally, new uncertainty quantifications methods and tools for the direct integration of uncertainty and variability information into grid operations at the transmission and distribution levels were developed and tested. During Phase 1, project work focused heavily on the design, development and demonstration of a set of processes and tools that could reliably and efficiently incorporate solar power into California’s grid operations. In Phase 2, connectivity between the ramping analysis tools and market applications software were completed, multiple dispatch scenarios demonstrated a successful reduction of overall uncertainty and an analysis to quantify increases in system operator reliability, and the transmission and distribution system uncertainty prediction tool was introduced to system operation engineers in a live webinar. The project met its goals, the experiments prove the advancements to methods and tools, when working together, are beneficial to not only the California Independent System Operator, but the benefits are transferable to other system operators in the United States.

14 SOLAR ENERGY↗

Cyber Conservative Operations

In an era of increasingly sophisticated and pervasive cyber threats, robust cyber resilience strategies are more critical than ever. This paper introduces the concept of Cyber Conservative Operations, a proactive approach designed to assist critical infrastructure owners and operators in managing risk and maintaining resilience in the face of imminent, yet not occurring, cyber events. By leveraging the principles of Cyber-Informed Engineering (CIE) and the energy sector’s practice of conservative operations, Cyber Conservative Operations offer a framework for planning and executing coordinated active defense and resilience-oriented actions ahead of cyber events. This approach aims to minimize the consequences of digitally-enabled hazards and ensure swift recovery from anticipated cyber threats. Cyber Conservative Operations enhance the ability of owners and operators to execute pre-planned defense and resilience actions, thereby reducing the impact of digitally-enabled hazards. These operations are crucial for addressing impacts that cannot be precisely quantified or forecasted and for preparing organizations for rapid recovery from imminent digital threats. The paper begins with a discussion of conservative operations as applied to the bulk power system (BPS), a current mechanism allowing BPS entities to enact defensive operating plans to mitigate impending grid unreliability. Building on this model, we present a concept for implementing cyber conservative operations at asset owner facilities. The paper concludes with two case studies of cyber conservative operations drawn from high-profile cyber events, illustrating the practical application and benefits of this proactive approach.

42 - ENGINEERING↗

In-situ Detection of Glovebox Glove Degradation Prior to Glove Failure; Effects on Safety, Waste, and Operational Costs - 20402

Glovebox glove pressure decay leak testing and analysis of the data can greatly improve glovebox safety, minimize Transuranic (TRU) glove waste, and minimize operational cost. It is well known, the weakest point of containment on a glovebox is the glove. Mitigating unplanned openings in gloves is critical to minimizing operational and safety costs in glovebox operations. Mitigating unplanned glove openings due to glove failures will be discussed in this paper. The lack of an engineered solution to determine a gloves operational life in nuclear operations, has lead to use of theoretical and manual subjective methods to determine the life and safety of a glovebox glove. Whether the glove is inspected visually prior to use, or gloves are changed regularly to theoretically avoid failure, both the operators PPE and the room are being exposed to contamination, or un-necessary amounts of TRU glove waste are being generated. Millions of dollars yearly in operational costs are spent on glove failures due to loss of production, incident analysis, regulatory audits, clean up, and paperwork. In a nuclear application, a glove failure could contaminate an operator and laboratory, shut down the operation for weeks, potentially create a regulatory audit, and potentially create a media frenzy; the damages to the organization can be astronomical. Elimination of glove failures is possible by tracking glove material degradation and setting limits to allow glove change when it becomes necessary, prior to glove failure. Analytical pressure decay leak testing allows the detection of material degradation, and in turn the ability to limit operational glove failures. A German based company called MK Versuchsanlagen, e.K., has developed an advanced Glove Integrity Testing System. The system, with its use of proprietary RFID and special software technology, is unique in its capabilities. The system is capable to perform highly accurate regular glove testing on any size glovebox line in minimal time. The system records and can analyze a tremendous amount of system data that in turn can determine, for example, a safe glove change time prior to a glove material failure. This paper will show how an advanced Glove Integrity Testing System can detect glove material degradation and help determine a safe change point prior to glove failure. Pressure decay curves of new gloves and recorded effects of accelerated aging on the glove over time will be shown. The use of this technology in nuclear facilities can greatly improve glovebox operational safety, minimize glovebox glove TRU waste, and save organizations tremendous costs in downtime, clean up, documentation, and potential regulatory review. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Operating displays - new concept: high performance displays - 118

New control rooms in Nuclear Power Plants using digital Distributed Control System (DCS) operated with software displays, are providing thousands of signals to the operating crew. When an event happens, the Flood of information provided to operators could obscure the initiator event increasing the operator response time, work load and complicating the selection of the actions to be performed. There are some initiatives that are trying to minimize the 'avalanche effect' as the alarm engineering filtering and prioritization or diagnostic displays. Likewise, new control rooms are lost the availability to know the plant status just with a quick glance to the panel indicators. Regarding Small Modular Reactors, where in some cases four operators should monitor and control twelve reactors, these problems are even more significant. The challenge is to find a solution, based on current digital systems, that supply information to operators in order to prevent events and take early actions to minimize or avoid any unexpected incident. In order to minimize human errors, Tecnatom has developed a specific set of displays, called 'High Performance Displays' (HPD) based on objectives, work environment limitation, and non-anticipated events. These displays are being design following the HFE standards: applying the NUREG-0711 elements to identify the information that they have to content and the NUREG-0700 to design the interface. The function of these displays is monitoring the plant situation in a way that the operators are able to recognize any potential event at a simple glance but controlling thousands of signals through pattern recognition, symmetries, regular polygons and colors. The objective of the HPD is to provide an integrated function minimizing the tunnel effect and reduce the workload during the diagnosis phase. Moreover, HPD enhance operators to take the right actions to anticipate the response to any event, even avoiding it, if possible This paper analyzes how HPD's have been design as well as presents the results of a preliminary validation of their capabilities. The preliminary validation is a reduce validation in a full scope simulator running two representative scenarios of abnormal and emergency operation. The analysis is focused on the first stage of the event, i.e. the detection phase, HPD's have been installed in a generic full scope simulator of a nuclear power plant, digital controlled. Both scenarios have been performed by two different operator crews. The first operator shift has worked with the conventional human machine interface, that is, displays similar to the ones currently installed in existing nuclear power plant with digital control. The second crew, reproduce the same scenarios but with HPD available. The studio collects preliminary data in order to compare results, draw lesson learned from the experience to improve HPD design, and find solutions in terms of reducing human errors, human workload, and increase the availability of the plant. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental study on team coordination of NPP plant operators based on the simultaneous NIRS measurements - 266

One of the key features when dealing with severe situations far beyond the previous experiences and expectations is the coordination capability among operators with different roles. In this study, the feasibility of estimating coordination capability of nuclear plant operators has been examined based on the correlation analysis of brain activities among operators. The cognitive experiments have been performed in the full scope NPP simulator at BWR Operator Training Center Cooperation. Four experienced instructors participated in the experiments. They played different roles such as shift supervisor, turbine operator, reactor operator and auxiliary operator and were instructed to go through four training scenarios shown below with NIRS devices attached. The brain activity of each operator has been measured along with the progress of anomaly events and the correlation of brain activities for every pair of operators have been calculated. The correlations of brain activities have also analyzed focusing on the specific events along with the progress in the anomaly scenarios. It has been shown in the results that the higher correlation among all operators were observed when the global events occurred and the higher correlation among specific pair of operators related to the specific event were partially observed. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Model Study of Blast Furnace Operation with Central Coke Charging

Blast furnace (BF) remains the dominant ironmaking process worldwide. Central coke charging (CCC) operation is a promising technology for stabilizing BF operations, but it needs reliable and quantified process design and control. In this work, a multi-fluid BF model is further developed for quantitatively investigating flow-thermal-chemical phenomena of a BF under CCC operation. This model features the respective chemical reactions in the respective coke and ore layers, and a specific sub-model of layer profile for the burden structure for the CCC operation. The simulation results confirm that the gas flow patterns and cohesive zone’s shape and location under the CCC operation are quite different from the non-CCC operation. Under the CCC operation, the heat is overloaded at the furnace center while the reduction load is much heavier at the periphery regions; the profiles of top gas temperature and gas utilization show bell-shape and inverse-bell-shape patterns, respectively. More importantly, these differences are characterized quantitatively. In this given case, when the CCC opening radius at the throat is 0.35 m, the cohesive zone top opening radius is around 0.50 m, and the isotherms of CCC operation become much steeper (~ 80 deg) than those of non-CCC operation (~ 60 deg) near BF central regions. In addition, it is confirmed that carbon solution-loss reaction rate can be decreased significantly at BF central regions under CCC operation. The model helps to understand CCC operation and provides a cost-effective method for optimizing BF practice.

36 MATERIALS SCIENCE↗

Automated Electric Vehicle Fleet Operations for On-Demand Service: Challenges and Opportunities

Automated/autonomous vehicle fleet operations within automated mobility districts have been studied over the past five years by the National Renewable Energy Laboratory, a US Department of Energy federally funded research and development center. This paper extends the analysis in this third phase of research underway to include considerations for electric vehicle operations and charging within a fleet of right-sized automated vehicles providing on-demand public mobility services. The current focus of research is on the operational complexities and associated challenges for automated/autonomous vehicles employing electric drivetrains and the resultant need for an efficient battery charging process while vehicles are operating in an "on-demand" mode of service. The blossoming of microtransit with shared-ride and point-to-point dispatching of each vehicle instills complex operations, with multiple mobility-on-demand transit operating sites being deployed, studied, and analyzed across North America. As a starting point, the authors' experience over the past 20 years with the analysis of automated transit network systems operating on and within dedicated and protected transitways provides initial insights into the system-level operational implications for maintaining a sufficient battery charge for a fleet of automated vehicles. Lessons learned through the prior analyses of automated transit network systems operating in on-demand service are identified, along with the capital cost implications for the requisite operating fleet size and charging station infrastructure for various approaches. These costs are summarized in juxtaposition with the benefits of realizing the higher goals of reducing environmental impacts and energy use within automated mobility districts as automated/autonomous vehicle technology matures. Finally, the discussion addresses key aspects of battery-electric propulsion for managed fleets in fully automated operation that will be studied as the third phase of research continues.

ADVANCED PROPULSION SYSTEMS↗

Progress in preparing scenarios for operation of the International Thermonuclear Experimental Reactor

The development of operating scenarios is one of the key issues in the research for ITER which aims to achieve a fusion gain (Q) of ∼10, while producing 500 MW of fusion power for ≥300 s. The ITER Research plan proposes a success oriented schedule starting in hydrogen and helium, to be followed by a nuclear operation phase with a rapid development towards Q ∼ 10 in deuterium/tritium. The Integrated Operation Scenarios Topical Group of the International Tokamak Physics Activity initiates joint activities among worldwide institutions and experiments to prepare ITER operation. Plasma formation studies report robust plasma breakdown in devices with metal walls over a wide range of conditions, while other experiments use an inclined EC launch angle at plasma formation to mimic the conditions in ITER. Simulations of the plasma burn-through predict that at least 4 MW of Electron Cyclotron heating (EC) assist would be required in ITER. For H-modes at q{sub 95} ∼ 3, many experiments have demonstrated operation with scaled parameters for the ITER baseline scenario at n{sub e}/n{sub GW} ∼ 0.85. Most experiments, however, obtain stable discharges at H{sub 98(y,2)} ∼ 1.0 only for β{sub N} = 2.0–2.2. For the rampup in ITER, early X-point formation is recommended, allowing auxiliary heating to reduce the flux consumption. A range of plasma inductance (l{sub i}(3)) can be obtained from 0.65 to 1.0, with the lowest values obtained in H-mode operation. For the rampdown, the plasma should stay diverted maintaining H-mode together with a reduction of the elongation from 1.85 to 1.4. Simulations show that the proposed rampup and rampdown schemes developed since 2007 are compatible with the present ITER design for the poloidal field coils. At 13–15 MA and densities down to n{sub e}/n{sub GW} ∼ 0.5, long pulse operation (>1000 s) in ITER is possible at Q ∼ 5, useful to provide neutron fluence for Test Blanket Module assessments. ITER scenario preparation in hydrogen and helium requires high input power (>50 MW). H-mode operation in helium may be possible at input powers above 35 MW at a toroidal field of 2.65 T, for studying H-modes and ELM mitigation. In hydrogen, H-mode operation is expected to be marginal, even at 2.65 T with 60 MW of input power. Simulation code benchmark studies using hybrid and steady state scenario parameters have proved to be a very challenging and lengthy task of testing suites of codes, consisting of tens of sophisticated modules. Nevertheless, the general basis of the modelling appears sound, with substantial consistency among codes developed by different groups. For a hybrid scenario at 12 MA, the code simulations give a range for Q = 6.5–8.3, using 30 MW neutral beam injection and 20 MW ICRH. For non-inductive operation at 7–9 MA, the simulation results show more variation. At high edge pedestal pressure (T{sub ped} ∼ 7 keV), the codes predict Q = 3.3–3.8 using 33 MW NB, 20 MW EC, and 20 MW ion cyclotron to demonstrate the feasibility of steady-state operation with the day-1 heating systems in ITER. Simulations using a lower edge pedestal temperature (∼3 keV) but improved core confinement obtain Q = 5–6.5, when ECCD is concentrated at mid-radius and ∼20 MW off-axis current drive (ECCD or LHCD) is added. Several issues remain to be studied, including plasmas with dominant electron heating, mitigation of transient heat loads integrated in scenario demonstrations and (burn) control simulations in ITER scenarios.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of GDI PM during Vehicle Start-Stop Operation

As the fuel economy regulations increase in stringency, many manufacturers are implementing start-stop operation to enhance vehicle fuel economy. During start-stop operation, the engine shuts off when the vehicle is stationary for more than a few seconds. When the brake is released by the driver, the engine restarts. Depending on traffic conditions, start-stop operation can result in fuel savings from a few percent to close to 10%. Gasoline direct injection (GDI) engines are also increasingly available on light-duty vehicles. While GDI engines offer fuel economy advantages over port fuel injected (PFI) engines, they also tend to have higher PM emissions, particularly during start-up transients. Thus, there is interest in evaluating the effect of start-stop operation on PM emissions. In this study, a 2.5L GDI vehicle was operated over the FTP75 drive cycle. Runs containing cold starts (FTP-75 cycle Phases 1 & 2) and multiple runs containing hot starts (FTP-75 cycle Phases 3 & 4) were performed each day. Note that the FTP-75 Phases 3 & 4 are identical to Phases 1 & 2 except that the engine is warmed up. Three fuels were evaluated: an 87 AKI gasoline (E0), a 21% splash blend of ethanol and the 87 AKI gasoline (E21), and a 12% splash blend of iso-butanol and the 87 AKI gasoline (iBu12). PM mass, transient particle number concentration and size distribution, and soot mass concentration were evaluated for both start-stop operation and no start-stop operation on each fuel. Three Phase 1 & 2 cycles and as many as 27 Phase 3 & 4 cycles were performed for each fuel-mode combination. Composite FTP mass emissions for E0 and iBu12 showed increased total PM emissions with start-stop operation, but E21 showed no difference. Statistical analysis of the effects of start-stop on PM number and soot emissions showed different trends for different fuels. For example, when E0 is used with start-stop operation, the particle number decreased but the soot mass tended to increase. The results of this study have implications for hybrid vehicle operation as well because the internal combustion engine in hybrid vehicles must stop and re-start during normal operation.

Storey, John↗

AVESTAR Center for Operational Excellence of Electricity Generation Plants

To address industry challenges in attaining operational excellence for electricity generation plants, the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) has launched a world-class facility for Advanced Virtual Energy Simulation Training and Research (AVESTARTM). This presentation will highlight the AVESTARTM Center simulators, facilities, and comprehensive training, education, and research programs focused on the operation and control of high-efficiency, near-zero-emission electricity generation plants. The AVESTAR Center brings together state-of-the-art, real-time, high-fidelity dynamic simulators with full-scope operator training systems (OTSs) and 3D virtual immersive training systems (ITSs) into an integrated energy plant and control room environment. AVESTAR’s initial offering combines--for the first time--a “gasification with CO2 capture” process simulator with a “combined-cycle” power simulator together in a single OTS/ITS solution for an integrated gasification combined cycle (IGCC) power plant with carbon dioxide (CO2) capture. IGCC systems are an attractive technology option for power generation, especially when capturing and storing CO2 is necessary to satisfy emission targets. The AVESTAR training program offers a variety of courses that merge classroom learning, simulator-based OTS learning in a control-room operations environment, and immersive learning in the interactive 3D virtual plant environment or ITS. All of the courses introduce trainees to base-load plant operation, control, startups, and shutdowns. Advanced courses require participants to become familiar with coordinated control, fuel switching, power-demand load shedding, and load following, as well as to problem solve equipment and process malfunctions. Designed to ensure work force development, training is offered for control room and plant field operators, as well as engineers and managers. Such comprehensive simulator-based instruction allows for realistic training without compromising worker, equipment, and environmental safety. It also better prepares operators and engineers to manage the plant closer to economic constraints while minimizing or avoiding the impact of any potentially harmful, wasteful, or inefficient events. The AVESTAR Center is also used to augment graduate and undergraduate engineering education in the areas of process simulation, dynamics, control, and safety. Students and researchers gain hands-on simulator-based training experience and learn how the commercial-scale power plants respond dynamically to changes in manipulated inputs, such as coal feed flow rate and power demand. Students also analyze how the regulatory control system impacts power plant performance and stability. In addition, students practice start-up, shutdown, and malfunction scenarios. The 3D virtual ITSs are used for plant familiarization, walk-through, equipment animations, and safety scenarios. To further leverage the AVESTAR facilities and simulators, NETL and its university partners are pursuing an innovative and collaborative R&D program. In the area of process control, AVESTAR researchers are developing enhanced strategies for regulatory control and coordinated plant-wide control, including gasifier and gas turbine lead, as well as advanced process control using model predictive control (MPC) techniques. Other AVESTAR R&D focus areas include high-fidelity equipment modeling using partial differential equations, dynamic reduced order modeling, optimal sensor placement, 3D virtual plant simulation, and modern grid. NETL and its partners plan to continue building the AVESTAR portfolio of dynamic simulators, immersive training systems, and advanced research capabilities to satisfy industry’s growing need for training and experience with the operation and control of clean energy plants. Future dynamic simulators under development include natural gas combined cycle (NGCC) and supercritical pulverized coal (SCPC) plants with post-combustion CO2 capture. These dynamic simulators are targeted for use in establishing a Virtual Carbon Capture Center (VCCC), similar in concept to the DOE’s National Carbon Capture Center for slipstream testing. The VCCC will enable developers of CO2 capture technologies to integrate, test, and optimize the operation of their dynamic capture models within the context of baseline power plant dynamic models. The objective is to provide hands-on, simulator-based “learn-by-operating” test platforms to accelerate the scale-up and deployment of CO2 capture technologies. Future AVESTAR plans also include pursuing R&D on the dynamics, operation, and control of integrated electricity generation and storage systems for the modern grid era. Special emphasis will be given to combining load-following energy plants with renewable and distributed generating supplies and fast-ramping energy storage systems to provide near constant baseload power.

97 MATHEMATICS AND COMPUTING↗

Implementing a micro-operation cache with compaction

Systems, apparatuses, and methods for compacting multiple groups of micro-operations into individual cache lines of a micro-operation cache are disclosed. A processor includes at least a decode unit and a micro-operation cache. When a new group of micro-operations is decoded and ready to be written to the micro-operation cache, the micro-operation cache determines which set is targeted by the new group of micro-operations. If there is a way in this set that can store the new group without evicting any existing group already stored in the way, then the new group is stored into the way with the existing group(s) of micro-operations. Metadata is then updated to indicate that the new group of micro-operations has been written to the way. Additionally, the micro-operation cache manages eviction and replacement policy at the granularity of micro-operation groups rather than at the granularity of cache lines.

Kotra, Jagadish B.↗

Hybrid electric vehicle and method of operating engine of the same

A hybrid electric vehicle (HEV) for multiple operation modes includes: a gasoline diffusion flame (GDF) combustion engine configured to perform gasoline diffusion flame combustion; a motor-generator operatively connected to the GDF combustion engine and configured to selectively drive the HEV with electric power of a battery or generate electric power to charge the battery; and a multi-mode controller including a processor and configured to receive operating conditions of the GDF combustion engine and the motor-generator and define a plurality of mode operating regions based on the received operating conditions. In particular, the plurality of mode operating regions includes: an electric vehicle (EV) only mode operating region, a GDF mode operating region where the GDF combustion engine operates and drives the HEV while the motor-generator stops, and a GDF+EV mode operating region where the motor-generator assists the operation of the GDF combustion engine to drive the HEV.

Bourcier, Mark↗

Automation Toward Tether-less Robotic Operations in Nuclear Facilities - 17474

Automation capabilities that enable communication-denied nuclear robotic operations have come of age. These layer over tethered operation or enable un-tethered systems for some operations. Tele-operated, tethered devices are traditionally preferred for nuclear remote systems. Tethers provide comm, power, and a means for mechanical extraction. They also restrict mobility and create additional failure points, and in some cases, circumstances preclude mechanical recovery by tether. Tethering has superb advantages where it is viable, but a subset of nuclear EM challenges compel mobile remote systems that forgo tethering. Tethering was essential at a time when autonomy or wireless comm could not accomplish viable operations, but now an emerging class of un-tethered exploration and service robots are compelling for situations where tethers compound waste and exposure, or are not viable. Technical advances in localization, modeling, planning, autonomy, integration and reliability have made it possible to augment tethered operations or operate altogether without tether in selective operations. Tether preclusion technologies include localization, perception, navigation, safeguarding and task prescription. These effectively accomplish tasks like way-point following, wall-following, coverage patterning, navigate-to-goal, next-best view and many others. Although these are not yet general for the broad agenda of the nuclear complex, these are already useful for many operations. These provide a foundational base that can be built upon over time for more complex operations yet to come. As a context and analog study, the technologies are exhibited by robotically (without tether) modeling a coal mine with tracks and train cars. This is analogous to technology and operation that might apply for inspection of waste storage at WIPP or the PUREX tunnels. Autonomous exploration of this nature is within state-of-art and possible with or without tether. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Groundwater remediation at the Fernald preserve, Cincinnati, Ohio modeling and resulting 2014 well field operational changes - 15324

The Fernald Preserve became a US DOE Office of Legacy Management site in November 2006, for long-term surveillance and maintenance following completion (with the exception of completing groundwater cleanup) of the Comprehensive Environmental Response, Compensation, and Liability Act; environmental remediation; and site restoration. When the site was turned over to the Office of Legacy Management, approximately 76 hectares (189 acres) of the Great Miami Aquifer (GMA) remained contaminated with uranium above the final remediation level of 30 micrograms per liter. Uranium contamination is being removed from groundwater in the GMA through a pump-and-treat operation that is predicted by groundwater modeling to continue until 2033. Certifying that cleanup objectives have been met and removing the remediation infrastructure after pump-and-treat (P and T) operations are complete will require a minimum of 3 additional years. The current P and T remedy has operated well. From August 1993 through December 2013 the remedy has been used to remove 5,345 kg (11,784 lb) of uranium from the GMA. A variety of metrics are used to track how the P and T operation is progressing and are reported each year in the Site Environmental Report for the Fernald site. The metrics show that the effectiveness of uranium removal is slowly decreasing (a common observation for P and T remedies) and that operational changes needed to be considered. Several different operational changes were modeled to determine if model-predicted cleanup dates could be shortened and if the effectiveness of the groundwater remediation could be improved. With the concurrence and support of US EPA, Ohio EPA, and site stakeholders, operational changes were agreed upon and implemented in 2014 that are predicted to increase the effectiveness of the ongoing operation and shorten cleanup times for a portion of the aquifer. Although the overall predicted length of the remediation was not shortened, modeling predicts that key areas of the uranium plume will be re-mediated sooner. This paper provides a status of the groundwater remediation under way at the Fernald Preserve near Cincinnati, presents the operational changes that were implemented in 2014, and summarizes the groundwater modeling that supported the changes. This paper also illustrates the potential benefits that can be gained by pro-actively managing a pump-and-treat operation and looking for innovative ways to adjust the operation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analytical solutions for quantum walks on 1D chain with different shift operators

In this paper, we study the discrete-time quantum walks on 1D Chain with the moving and swapping shift operators. We derive analytical solutions for the eigenvalues and eigenstates of the evolution operator U{sup -hat} using the Chebyshev polynomial technique, and calculate the long-time averaged probabilities for the two different shift operators respectively. It is found that the probability distributions for the moving and swapping shift operators display completely different characteristics. For the moving shift operator, the probability distribution exhibits high symmetry where the probabilities at mirror positions are equal. The probabilities are inversely proportional to the system size N and approach to zero as N→∞. On the contrary, for the swapping shift operator, the probability distribution is not symmetric, the probability distribution approaches to a power-law stationary distribution as N→∞ under certain coin parameter condition. We show that such power-law stationary distribution is determined by the eigenstates of the eigenvalues ±1 and calculate the intrinsic probability for different starting positions. Our findings suggest that the eigenstates corresponding to eigenvalues ±1 play an important role for the swapping shift operator. - Highlights: • QWs on 1D chain with the moving and swapping operators are studied for the first time. • We derive analytical results for the probability distribution for the two operators. •We compare the dynamics of QWs with two different shift operators. • We find the particular eigenvalues ±1 play an important role for the dynamics. • We use the Chebyshev technique to treat the problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗