Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Notes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Note: X-ray streak camera sweep speed calibration

X-ray streak cameras are extensively used to study transient x-ray processes in experiments carried out on various laser facilities at the Research Center of Laser Fusion. Precise calibration and clear description of the sweep speed of the x-ray streak camera are vital for obtaining precise temporal information to understand the fast physics phenomena. An x-ray streak camera named wide-slit x-ray streak camera has been calibrated using a small-scale laser facility with pulse duration of 8 ps. Sweep speeds on most part of the output screen (charge coupled device) are obtained. These calibration results can be used to correct the nonlinearity of sweep speed in measurement of temporal processes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A simple dual polarity dual nanoelectrospray ionization source for ion/ion reactions

A continuously operated dual polarity dual nanoelectrospray ionization source has been constructed and tested. A commercial quadrupole ion trap mass spectrometer was modified to accumulate and trap ions of opposite charge. All changes to the commercial three-dimensional quadrupole ion trap have been made external to the instrument outside of the vacuum system. Few hardware modifications were required because the two emitters send ion beams through the same transmission guides. Computer controlled source voltage polarities are switched quickly and efficiently to transmit one of two continuously generated ion beams. With customized software, this design has proved simple to implement and to operate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Note: Rigid holder to host and bend a crystal for multiple volume reflection of a particle beam

A holder to lodge and bend a silicon crystal to excite multivolume reflection of a high-energy particle beam has been designed and fabricated. A mechanically robust and stable structure fastens a crystal at best condition for experiments. The holder has allowed the observation of 12-time repeated volume reflection with very high efficiency. We detail the most important features behind the construction of the holder together with the characterization of the crystal being bent by the holder.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: New design of a cryogenic linear radio frequency multipole trap

A new design of a cryogenic linear 22-pole ion trap has been constructed and tested. It is essentially a copper housing to which opposite inner walls two electrode sets are attached via sapphire insulators. These stainless steel electrodes are electroformed in one piece to guarantee good heat conduction. Connected to an external coil, they form an LC-circuit of about 19 MHz resonance frequency. This circuit is excited with a rf power supply made of a commercial digital synthesizer followed by a 10 W amplifier. Buffer gas-cooled H{sub 2}D{sup +} ions have been stored in this trap at a nominal trap temperature of 14 K. Spectroscopy of the ions confirmed that the kinetic (Doppler) temperature is in reasonable agreement with this value.

43 PARTICLE ACCELERATORS↗

Note: A modular and robust continuous supersonic expansion discharge source

A direct current discharge has been coupled with a continuous supersonic expansion to provide a source of rotationally cold molecular ions for gas phase spectroscopy. Constructed primarily of machinable ceramic and stainless steel, this source design is modular, customizable, and robust. Its performance has been assessed by recording transitions within the {nu}{sub 2} fundamental band of H{sub 3}{sup +} using cavity ringdown spectroscopy to determine the rotational temperature of ions produced in the free-jet expansion. Temperature and column density were recorded as a function of discharge current as the source was operated over a period of 200 h. Observed temperatures ranged between 50-110 K, and the ion column densities between 8x10{sup 10} and 2x10{sup 12} cm{sup -2}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Fixture for characterizing electrochemical devices in-operando in traditional vacuum systems

We describe a fixture that allows electrochemical devices to be studied under electrical bias in the type of vacuum systems commonly used in surface science. Three spring-loaded probes provide independent contacts for device operation and the characterization in vacuum or under in situ conditions with reactive gases. We document the robustness of the electrical contacts over large temperature changes and their reliability for conventional electrochemical measurements such as impedance spectroscopy. The optical access provided to the device enables the analysis by many techniques, as we demonstrate using x-ray photoelectron spectroscopy to measure local electrical potentials on a solid-oxide electrolyte device operating at high temperature in near-ambient pressure.

36 MATERIALS SCIENCE↗

Publisher's Note: ''The MaPLE device of Saha Institute of Nuclear Physics: Construction and its plasma aspects'' [Rev. Sci. Instrum. 81, 073507 (2010)]

The Magnetized Plasma Linear Experimental (MaPLE) device is a low cost laboratory plasma device at Saha Institute of Nuclear Physics fabricated in-house with the primary aim of studying basic plasma physics phenomena such as plasma instabilities, wave propagation, and their nonlinear behavior in magnetized plasma regime in a controlled manner. The machine is specially designed to be a versatile laboratory device that can provide a number of magnetic and electric scenario to facilitate such studies. A total of 36 number of 20-turn magnet coils, designed such as to allow easy handling, is capable of producing a uniform, dc magnetic field of about 0.35 T inside the plasma chamber of diameter 0.30 m. Support structure of the coils is planned in an innovative way facilitating straightforward fabrication and easy positioning of the coils. Further special feature lies in the arrangement of the spacers between the coils that can be maneuvered rather easily to create different magnetic configurations. Various methods of plasma production can be suitably utilized according to the experimental needs at either end of the vacuum vessel. In the present paper, characteristics of a steady state plasma generated by electron cyclotron resonance method using 2.45 GHz microwave power are presented. Scans using simple probe drives revealed that a uniform and long plasma column having electron density {approx} 3-5 Multiplication-Sign 1010 cm-3 and temperature {approx} 7-10 eV, is formed in the center of the plasma chamber which is suitable for wave launching experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Note: Tangential x-ray diagnosis for investigating fast MHD events in EAST tokamak

A tangential x-ray diagnosis has been installed in the experimental advanced superconducting tokamakvacuum vessel for the study of fast magnetohydrodynamics (MHD) events. This system is based on absolute x-ray ultraviolet detectors with a collimator which is processed by laser machine. The first experimental results have proved its ability to measure the small-scale and transient MHD perturbations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Light output enhanced fast response and low afterglow {sup 6}Li glass scintillator as potential down-scattered neutron diagnostics for inertial confinement fusion

The characteristics of an APLF80+3Ce scintillator are presented. Its sufficiently fast decay profile, low afterglow, and an improved light output compared to the recently developed APLF80+3Pr, were experimentally demonstrated. This scintillator material holds promise for applications in neutron imaging diagnostics at the energy regions of 0.27 MeV of DD fusion down-scattered neutron peak at the world's largest inertial confinement fusion facilities such as the National Ignition Facility and the Laser Megajoule.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Electrical resolution during conductive atomic force microscopy measurements under different environmental conditions and contact forces

Conductive atomic force microscopy experiments on gate dielectrics in air, nitrogen, and UHV have been compared to evaluate the impact of the environment on topography and electrical measurements. In current images, an increase of the lateral resolution and a reduction of the conductivity were observed in N{sub 2} and, especially, in UHV (where current depends also on the contact force). Both effects were related to the reduction/elimination of the water layer between the tip and the sample in N{sub 2}/UHV. Therefore, since current measurements are very sensitive to environmental conditions, these factors must be taken into consideration when comparisons between several experiments are performed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A robust low-cost high-sensitivity subangstrom bidirectional displacement sensor

The design of a simple, robust, low-cost, and bidirectional displacement sensor with subangstrom resolution is described. A small gold plate is attached to the object, whose displacement is to be measured, and a small gold tip is brought into contact with the plate, establishing a reference current between the two. Movements of the gold plate away from the tip lead to a change in the tip-plate current; the reference current is then re-established by moving the tip using a simple magnetic actuator. The resolution of the sensor has been calibrated using an interferometer and was shown to be as high as 0.3 A per system count. Potential applications of the sensor are numerous, including microbar air pressure measurement, motion and infrasound detection, thermal sensing, and gravitational field and relativistic gravity wave measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Note on Eccentricities within a Single n-Layered Obstacle and their Influence on Time Harmonic SH Waves

In this contribution some aspects of SH wave scattering due to a single eccentric n-layered obstacle are being looked at. Herewith, the basis solution is derived analytically for an elliptic inclusion as it occurs in civil engineering practice e. g. within textile reinforced concrete. Hence, (modified) MATHIEUfunctions have to be evaluated. Later on, the degenerate case of an eccentric circular obstacle is dealt with.

36 MATERIALS SCIENCE↗

Note: A helical velocity selector for continuous molecular beams

We report on a modern realization of the classic helical velocity selector for gas phase particle beams. The device operates stably under high vacuum conditions at rotational frequencies limited only by commercial dc motor capabilities. Tuning the rotational frequency allows selective scanning over a broad velocity band. The width of the selected velocity distributions at full-width-half-maximum is as narrow as a few percent of the selected mean velocity and independent of the rotational speed of the selector. The selector generates low vibrational noise amplitudes comparable to mechanically damped state-of-the-art turbo-molecular pumps and is therefore compatible with vibration sensitive experiments like molecule interferometry.

43 PARTICLE ACCELERATORS↗