Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

How to Educate Decision Makers on the Value and Necessity of Modal Testing and Model Correlation: Tips for Young Engineers

Engineers need to effectively communicate the justification and value of their modal testing and model correlation in terminology familiar to decision makers as it relates to the program’s risk tolerance. This communication must relate to the program’s risk tolerance and the metrics used to judge the performance of both the program and individual decision makers. The challenge is the terminologies familiar to engineers and decision makers are quite different and seemingly unrelated. The engineering profession has developed a specific terminology to solve highly technical issues, which are many times themselves unique to very specific engineering problems. It is all too easy for engineers to believe that everyone in their organization, including the decision makers, has an intrinsic understanding of what they do and the value it brings to the program’s success. This is especially true for young engineers who have recently spent the last four plus years in an academic engineering learning environment, which has a highly technical research oriented atmosphere. Effective communication with decision makers is increasingly important as the technical breadth and practical program and project experience level for up and coming decision makers diminishes. It is not unusual for the decision makers to have technical knowledge in a domain different from structural dynamics (e.g., electronics or systems). Competition among satellite manufactures has increased the focus on programmatic cost and ability to deliver on schedule. NASA programs are also seeing more restrictive programmatic cost and schedule constraints, which impact both analysis and testing. It should also be noted that a comprehensive suite of tests are required to verify a satellite’s design capability with some margin. These tests include static strength verification tests, shock, acoustic, and vibration tests (sine and random) of systems, subsystems, and components. Each of these verification tests provide opportunities for model correlation and risk reduction. It is important to recognize dynamic loads/modal test models may not include all of the flight hardware (i.e., harness, coax, waveguides, connectors, etc.) and the previously mentioned tests are still required for qualification/verification of the design. This paper provides tips to young engineers on how to bridge this communications gap, have a better understanding of the environment in which decision makers operate, and assist them to better support successful missions. While this paper primarily focuses on modal testing and model correlation as related to spacecraft missions, the concepts and recommendations presented here are equally applicable to other fields such as aeronautics, automotive, power generation, etc.

Decision Maker↗

Defining the mechanistic binding of viral particles to a multi‐modal anion exchange resin

A multi‐tiered approach to determine the binding mechanism of viral clearance utilizing a multi‐modal anion exchange resin was applied to a panel of four viral species that are typically used in validating viral clearance studies (i.e., X‐MuLV, MVM, REO3, and PrV). First, virus spiked buffer‐only experiments were conducted to evaluate the virus's affinity for single mode and multi‐modal chromatography resins under different buffer conditions in a chromatography column setting. From these results we hypothesize that the mechanisms of binding of the viruses involve binding to both the hydrophobic and anionic functional groups. This mechanistic view agreed with the general surface characteristics of the different virus species in terms of isoelectric point and relative hydrophobicity values. This hypothesized mechanistic binding was then tested with commercially relevant, in‐process materials, in which competitive binding occurred between the load components (e.g., viruses, target product, and impurities) and the resin. © 2018 American Institute of Chemical Engineers Biotechnol. Prog. , 34:1019–1026, 2018

Brown, Matthew R.↗

The small molecule survivin inhibitor YM155 may be an effective treatment modality for colon cancer through increasing apoptosis

Survivin has a known beneficial role in the survival of both cancer cells and normal cells. Therapies targeting survivin have been proposed as an alternative treatment modality for various tumors; however, finding the proper indication for this toxic therapy is critical for reducing unavoidable side effects. We recently observed that high survivin expression in CD133{sup +} cells is related to chemoresistance in Caco-2 colon cancer cells. However, the effect of survivin-targeted therapy on CD133{sup +} colon cancer is unknown. In this study, we investigated the roles of CD133 and survivin expression in colon cancer biology in vitro and comparatively analyzed the anticancer effects of survivin inhibitor on CD133{sup +} cells (ctrl-siRNA group) and small interfering RNA (siRNA)-induced CD133{sup −} cells (CD133-siRNA group) obtained from a single colon cancer cell line. CD133 knockdown via siRNA transfection did not change the tumorigenicity of cells, although in vitro survivin expression levels in CD133{sup +} cells were higher than those in siRNA-induced CD133{sup −} cells. The transfection procedure seemed to induce survivin expression. Notably, a significant number of CD133{sup −} cells (33.8%) was found in the cell colonies of the CD133-siRNA group. In the cell proliferation assay after treatment, YM155 and a combination of YM155 and 5-fluorouracil (5-FU) proved to be far more effective than 5-FU alone. A significantly increased level of apoptosis was observed with increasing doses of YM155 in all groups. However, significant differences in therapeutic effect and apoptosis among the mock, ctrl-siRNA, and CD133-siRNA groups were not detected. Survivin inhibitor is an effective treatment modality for colon cancer; however, the role of CD133 and the use of survivin expression as a biomarker for this targeted therapy must be verified.

60 APPLIED LIFE SCIENCES↗

A combined salt–hard templating approach for synthesis of multi-modal porous carbons used for probing the simultaneous effects of porosity and electrode engineering on EDLC performance

A novel approach, based on a combination of salt and hard templating for producing multi-modal porous carbons is demonstrated. The hard template, silica nanoparticles, generate mesopores (~22 nm), and in some cases borderline-macropores (~64 nm), resulting in high pore volume (~3.9 cm 3 /g) while the salt template, zinc chloride, generates borderline-mesopores (~2 nm), thus imparting high surface area (~2100 m2/g). The versatility of the proposed synthesis technique is demonstrated using: (i) dual salt templates with hard template resulting in magnetic, nanostructured-clay embedded (~27% clay content), high surface area (~1527 m 2 /g) bimodal carbons (~2 and 70 nm pores), (ii) multiple hard templates with salt template resulting in tri-modal carbons (~2, 12 and 28 nm pores), (iii) low temperature (450 °C) synthesis of bimodal carbons afforded by the presence of hygroscopic salt template, (iv) easy coupling with physical activation approaches. A selected set of thus synthesized carbons were used to evaluate, for the first time, the simultaneous effects of carbon porosity and pressure applied during electrode fabrication on EDLC performance. Electrode pressing was discovered to be more favorable for carbons containing hard-templated mesopores (~87% capacitance retention at current density of 40 A/g) as compared to those without (~54% capacitance retention).

36 MATERIALS SCIENCE↗

Amorphous Ag 2-x Cu x S quantum dots: “all-in-one” theranostic nanomedicines for near-infrared fluorescence/photoacoustics dual-modal-imaging-guided photothermal therapy

Integrating dual-modal imaging and photothermal effect within a single nanosystem is an enormous challenge for current nanomedicine application. In this study, non-toxic amorphous Ag 2-x Cu x S quantum dots (QDs) possessing near-infrared fluorescence (NIRF), enhanced photothermal and photoacoustic (PA) performance, as “one-in-all” nanomedicines, are designed and obtained. Cu doping in amorphous Ag 2 S QDs causes red-shift of NIRF to the lowest tissue absorption wavelength in so called “first biowindow” (~820 nm) and improves photothermal conversion efficiency to 44.0% simultaneously. Density functional theory simulation results suggest the fluorescence red-shift and enhanced photothermal/photoacoustics properties can be attributed to the generation of intragap states introduced by Cu doping. The amorphous Ag 2-x Cu x S QDs exhibit high long-term biocompatibility. Under a single laser irradiation with relatively low power density, an effective tumor ablation induced by high photothermal effect of amorphous Ag 2-x Cu x S QDs is achieved in vivo. Simultaneously, the PTT process can be guided by high quality NIRF/PA dual-modal-imaging.

36 MATERIALS SCIENCE↗

Cone-Beam CT-Based Delineation of Stereotactic Lung Targets: The Influence of Image Modality and Target Size on Interobserver Variability

Purpose: It is generally agreed that the safe implementation of stereotactic body radiotherapy requires image guidance. The aim of this work was to assess interobserver variability in the delineation of lung lesions on cone-beam CT (CBCT) images compared with CT-based contouring for adaptive stereotactic body radiotherapy. The influence of target size was also evaluated. Methods and Materials: Eight radiation oncologists delineated gross tumor volumes in 12 patient cases (non-small cell lung cancer I-II or solitary metastasis) on planning CTs and on CBCTs. Cases were divided into two groups with tumor diameters of less than (Group A) or more than 2 cm (Group B). Comparison of mean volumes delineated by all observers and range and coefficient of variation were reported for each case and image modality. Interobserver variability was assessed by means of standard error of measurement, conformity index (CI), and its generalized observer-independent approach. The variance between single observers on CT and CBCT images was measured via interobserver reliability coefficient. Results: Interobserver variability on CT images was 17% with 0.79 reliability, compared with 21% variability on CBCT and 0.76 reliability. On both image modalities, values of the intraobserver reliability coefficient (0.99 for CT and 0.97 for CBCT) indicated high reproducibility of results. In general, lower interobserver agreement was observed for small lesions (CI{sub genA} = 0.62 {+-} 0.06 vs. CI{sub genB} = 0.70 {+-} 0.03, p < 0.05). The analysis of single patient cases revealed that presence of spicules, diffuse infiltrations, proximity of the tumors to the vessels and thoracic wall, and respiration motion artifacts presented the main sources of the variability. Conclusion: Interobserver variability for Stage I-II non-small cell lung cancer and lung metastasis was slightly higher on CBCT compared with CT. Absence of significant differences in interobserver variability suggests that CBCT imaging provides an effective tool for tumor localization, and image data could be also used for target volume delineation purposes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Influence of Radiation Modality and Lymph Node Dissection on Survival in Early-Stage Endometrial Cancer

Background: The appropriate uses of lymph node dissection (LND) and adjuvant radiation therapy (RT) for Stage I endometrial cancer are controversial. We explored the impact of specific RT modalities (whole pelvic RT [WPRT], vaginal brachytherapy [VB]) and LND status on survival. Materials and Methods: The Surveillance Epidemiology and End Results dataset was queried for all surgically treated International Federation of Gynecology and Obstetrics (FIGO) Stage I endometrial cancers; subjects were stratified into low, intermediate and high risk cohorts using modifications of Gynecologic Oncology Group (GOG) protocol 99 and PORTEC (Postoperative Radiation Therapy in Endometrial Cancer) trial criteria. Five-year overall survival was estimated, and comparisons were performed via the log-rank test. Results: A total of 56,360 patients were identified: 70.4% low, 26.2% intermediate, and 3.4% high risk. A total of 41.6% underwent LND and 17.6% adjuvant RT. In low-risk disease, LND was associated with higher survival (93.7 LND vs. 92.7% no LND, p < 0.001), whereas RT was not (91.6% RT vs. 92.9% no RT, p = 0.23). In intermediate-risk disease, LND (82.1% LND vs. 76.5% no LND, p < 0.001) and RT (80.6% RT vs. 74.9% no RT, p < 0.001) were associated with higher survival without differences between RT modalities. In high-risk disease, LND (68.8% LND vs. 54.1% no LND, p < 0.001) and RT (66.9% RT vs. 57.2% no RT, p < 0.001) were associated with increased survival; if LND was not performed, VB alone was inferior to WPRT (p = 0.01). Conclusion: Both WPRT and VB alone are associated with increased survival in the intermediate-risk group. In the high-risk group, in the absence of LND, only WPRT is associated with increased survival. LND was also associated with increased survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microstructure characterization and nano & micro hardness of tri-modal microstructure of titanium alloy under different hot working conditions

Highlights: • The contents and sizes of α{sub p} and α{sub l} are determined by the processing parameters of first and second step. • The morphology of α{sub s} embedded in β phase is determined by the accumulated distortional strain energy and dislocations. • α{sub p} becomes harder as the strain rate of the first step increases due to the constantly enhanced work hardening effect. • β{sub t} is always harder than α{sub p} and α{sub l} due to the interfacial-strengthening effect. • The hardness of α{sub l} makes the greatest contribution in the integrated hardness of tri-modal microstructure. - Abstract: In this work, the dependences of tri-modal microstructure parameters and corresponding nano & micro hardness on through-process processing parameters were quantitatively studied during the three-step thermo-mechanical processing of TA15 titanium alloy. It is found that the processing parameters of first step, especially for the deformation temperature and strain rate, mainly affect primary equiaxed α (α{sub p}) through the α → β phase transformation and the competition between dynamic recovery and dynamic recrystallization. The second processing step primarily affects the content and thickness of lamellar α (α{sub l}). In the third processing step, compared with low-temperature aging, normal annealing provides sufficient driving force for α{sub l} and secondary lamellar α (α{sub s}) growing, which leads to thicker α{sub l} and α{sub s}. As for the nano & micro hardness, in one sample undergoing different process, transformed β matrix (β{sub t}) is always harder than α{sub l} and α{sub s} due to the interfacial-strengthening effect. In addition, with increasing strain rate of the first step, α{sub p} becomes harder due to the constantly enhanced work hardening effect while the hardness of β{sub t} varies little because of the competition between interfacial strengthening and distribution disorder degree. However, the nano hardness of α{sub l} decreases firstly and then increases with strain rate, which presents the same trend with the micro hardness of integrated hardness at different processing conditions.

36 MATERIALS SCIENCE↗

Multi-modal imaging of a single mouse brain over five orders of magnitude of resolution

Mammalian neurons operate at length scales spanning six orders of magnitude; they project millimeters to centimeters across brain regions, are composed of micrometer-scale-diameter myelinated axons, and ultimately form nanometer scale synapses. Capturing these anatomical features across that breadth of scale has required imaging samples with multiple independent imaging modalities. Translating between the different modalities, however, requires imaging the same brain with each. Here, we imaged the same postmortem mouse brain over five orders of spatial resolution using MRI, whole brain micrometer-scale synchrotron x-ray tomography ($\mu$CT), and large volume automated serial electron microscopy. Using this pipeline, we can track individual myelinated axons previously relegated to axon bundles in diffusion tensor MRI or arbitrarily trace neurons and their processes brain-wide and identify individual synapses on them. This pipeline provides both an unprecedented look across a single brain's multi-scaled organization as well as a vehicle for studying the brain's multi-scale pathologies.

59 BASIC BIOLOGICAL SCIENCES↗

Anaerobic digestion of organic fraction of municipal solid waste combining two pretreatment modalities, high temperature microwave and hydrogen peroxide

Highlights: Black-Right-Pointing-Pointer Microwave and H{sub 2}O{sub 2} pretreatment were studied to enhance anaerobic digestion of organic waste. Black-Right-Pointing-Pointer The whole waste pretreated at 115 Degree-Sign C or 145 Degree-Sign C had the highest biogas production. Black-Right-Pointing-Pointer Biogas production of the whole waste decreased at 175 Degree-Sign C due to formation of refractory compounds. Black-Right-Pointing-Pointer Pretreatment to 145 Degree-Sign C and 175 Degree-Sign C were the best when considering only the free liquid fraction. Black-Right-Pointing-Pointer H{sub 2}O{sub 2} pretreatment had a lag phase and the biogas production was not higher than MW pretreated samples. - Abstract: In order to enhance anaerobic digestion (AD) of the organic fraction of municipal solid waste (OFMSW), pretreatment combining two modalities, microwave (MW) heating in presence or absence of hydrogen peroxide (H{sub 2}O{sub 2}) were investigated. The main pretreatment variables affecting the characteristics of the OFMSW were temperature (T) via MW irradiation and supplemental water additions of 20% and 30% (SWA20 and SW30). Subsequently, the focus of this study was to evaluate mesophilic batch AD performance in terms of biogas production, as well as changes in the characteristics of the OFMSW post digestion. A high MW induced temperature range (115-175 Degree-Sign C) was applied, using sealed vessels and a bench scale MW unit equipped with temperature and pressure controls. Biochemical methane potential (BMP) tests were conducted on the whole OFMSW as well as the liquid fractions. The whole OFMSW pretreated at 115 Degree-Sign C and 145 Degree-Sign C showed 4-7% improvement in biogas production over untreated OFMSW (control). When pretreated at 175 Degree-Sign C, biogas production decreased due to formation of refractory compounds, inhibiting the digestion. For the liquid fraction of OFMSW, the effect of pretreatment on the cumulative biogas production (CBP) was more pronounced for SWA20 at 145 Degree-Sign C, with a 26% increase in biogas production after 8 days of digestion, compared to the control. When considering the increased substrate availability in the liquid fraction after MW pretreatment, a 78% improvement in biogas production vs. the control was achieved. Combining MW and H{sub 2}O{sub 2} modalities did not have a positive impact on OFMSW stabilization and enhanced biogas production. In general, all samples pretreated with H{sub 2}O{sub 2} displayed a long lag phase and the CBP was usually lower than MW irradiated only samples. First order rate constant was calculated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Incorporation of sensing modalities into de novo designed fluorescence-activating proteins

Through the efforts of many groups, a wide range of fluorescent protein reporters and sensors based on green fluorescent protein and its relatives have been engineered in recent years. Here we explore the incorporation of sensing modalities into de novo designed fluorescence-activating proteins, called mini-fluorescence-activating proteins (mFAPs), that bind and stabilize the fluorescent cis -planar state of the fluorogenic compound DFHBI. We show through further design that the fluorescence intensity and specificity of mFAPs for different chromophores can be tuned, and the fluorescence made sensitive to pH and Ca 2+ for real-time fluorescence reporting. Bipartite split mFAPs enable real-time monitoring of protein–protein association and (unlike widely used split GFP reporter systems) are fully reversible, allowing direct readout of association and dissociation events. The relative ease with which sensing modalities can be incorporated and advantages in smaller size and photostability make de novo designed fluorescence-activating proteins attractive candidates for optical sensor engineering.

59 BASIC BIOLOGICAL SCIENCES↗

Imaging 3D chemistry at 1 nm resolution with fused multi-modal electron tomography

Measuring the three-dimensional (3D) distribution of chemistry in nanoscale matter is a longstanding challenge for metrological science. The inelastic scattering events required for 3D chemical imaging are too rare, requiring high beam exposure that destroys the specimen before an experiment is completed. Even larger doses are required to achieve high resolution. Thus, chemical mapping in 3D has been unachievable except at lower resolution with the most radiation-hard materials. Here, high-resolution 3D chemical imaging is achieved near or below one-nanometer resolution in an Au-Fe 3 O 4 metamaterial within an organic ligand matrix, Co 3 O 4 -Mn 3 O 4 core-shell nanocrystals, and ZnS-Cu 0.64 S 0.36 nanomaterial using fused multi-modal electron tomography. Multi-modal data fusion enables high-resolution chemical tomography often with 99% less dose by linking information encoded within both elastic (HAADF) and inelastic (EDX/EELS) signals. We thus demonstrate that sub-nanometer 3D resolution of chemistry is measurable for a broad class of geometrically and compositionally complex materials.

36 MATERIALS SCIENCE↗

Imaging atomic-scale chemistry from fused multi-modal electron microscopy

Efforts to map atomic-scale chemistry at low doses with minimal noise using electron microscopes are fundamentally limited by inelastic interactions. Here, fused multi-modal electron microscopy offers high signal-to-noise ratio (SNR) recovery of material chemistry at nano- and atomic-resolution by coupling correlated information encoded within both elastic scattering (high-angle annular dark-field (HAADF)) and inelastic spectroscopic signals (electron energy loss (EELS) or energy-dispersive x-ray (EDX)). By linking these simultaneously acquired signals, or modalities, the chemical distribution within nanomaterials can be imaged at significantly lower doses with existing detector hardware. In many cases, the dose requirements can be reduced by over one order of magnitude. This high SNR recovery of chemistry is tested against simulated and experimental atomic resolution data of heterogeneous nanomaterials.

36 MATERIALS SCIENCE↗

Robust surface coating for a fast, facile fluorine-18 labeling of iron oxide nanoparticles for PET/MR dual-modality imaging

Grafting a robust organic shell around inorganic nanoparticles can optimize their colloidal features to dramatically improve their physicochemical properties. Here, we have developed a polymer coating procedure for providing colloidal stability to the nanoparticles and, more importantly, for applying a fast, facile fluorine-18 labeling of iron oxide nanoparticles (IONPs) for positron emission tomography (PET)/magnetic resonance (MR) dual-modality imaging. The structure of the amphiphilic polymer is based on a backbone of polyacrylic acid, conjugated with multiple oleylamines to form a comb-like branched structure. The dense polymer shell provides high colloidal stability to the IONPs against harsh conditions such as high temperature, low pH value, and high ion strength. By incorporating a 1,4,7-triazacyclononane (NOTA) chelator to the comb-like amphiphilic polymer for the chelation of aluminum fluoride ions, we applied a one-step radiolabeling approach for a fast, facile radiofluorination of magnetic nanoparticles. The new strategy can significantly reduce the procedure time and radiation exposure. In conclusion, the PET/MR dual modality imaging was successfully achieved in living subjects by using 18 F labeled magnetic nanoparticles.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A multi-modal sweat sensing patch for cross-verification of sweat rate, total ionic charge, and Na + concentration

Sweat sensors introduced in recent years have targeted a variety of sweat features and biomarkers for non-invasive health monitoring. Amongst these targets, reliable monitoring of sweat rate is crucial due to its modulation of sweat analyte concentrations and its intrinsic significance to numerous medical and physiological health conditions. In this paper, we present a sweat rate sensor structure comprising of electrodes with interdigitated fingers in a microfluidic channel. Each time the accumulating sweat impinges on an electrode finger, the sensor reports a jump in admittance that can be simply and efficiently counted to estimate sweat rate, overcoming selectivity limitations of previously reported sweat rate sensors. We further integrate an impedimetric sensor for measuring total ionic charge concentration and an electrochemical Na + sensor, together creating a multi-modal system for analyzing fluid and electrolyte secretion. We demonstrate how low analyte diffusion rates through this microfluidic device allow for multi-purpose sensor function, including utilizing the sweat rate sensor signal to corroborate total ionic sensor measurements. This cross-verification capability ensures data integrity in real time, satisfying a vital consideration for personalized healthcare technologies. We use the presented patch for continuous analysis of sweat rate, total ionic charge concentration, and Na + concentration during exercise, while demonstrating how multi-modal cross-verification brings new trust to sensor readings.

47 OTHER INSTRUMENTATION↗

Efficient Full-Field Vibration Measurements and Operational Modal Analysis Using Neuromorphic Event-Based Imaging

Traditional vibration measurement typically requires physically attached sensors, such as accelerometers and strain gauges. However, these discrete-point sensors provide only low spatial resolution vibration measurements, potentially foregoing valuable structural information such as localized damage. Noncontact optical measurement methods such as laser vibrometers can achieve high spatial resolution vibration measurements but only through time-consuming sequential measurements and are not cost-effective. As an alternative to traditional vibration measurement methods, digital video cameras are relatively low-cost, agile, and offer noncontact, simultaneous high spatial resolution measurements where every pixel on the structure becomes a measurement point. However, regular digital video cameras are frame-based where each pixel simultaneously performs temporally uniform (synchronous) measurements containing large amounts of redundant (background) data, which consumes considerable resources for video data measurement, management, and processing. To alleviate such a challenge, this work explores the use of event-based neuromorphic imagers, specifically silicon retinas, an efficient alternative to traditional frame-based video cameras, to perform full-field vibration measurements and operational modal analysis. By imitating biological vision, each silicon retina pixel independently and asynchronously records only intensity change events that contain structural motion information while excluding redundant (background) information. Such an asynchronous event-based data measurement mechanism allows for structural motion to be captured on the microsecond scale in an extremely data-efficient manner, which could benefit real-time vibration measurement and control applications. This study takes the first step toward these applications by formulating an existing video frame-based full-field operational modal analysis technique in the event-based, asynchronous silicon retina measurement framework. Specifically, local phase-based motion extraction and blind source separation are used to automatically and efficiently extract full-field vibration and dynamics parameters from silicon retina measurements. The developed method is validated by laboratory experiments on a bench-scale cantilever beam.

42 ENGINEERING↗

Epi-detected quadruple-modal nonlinear optical microscopy for label-free imaging of the tooth

We present an epi-detected quadruple-modal nonlinear optical microscopic imaging technique (i.e., coherent anti-Stokes Raman scattering (CARS), second-harmonic generation (SHG), third-harmonic generation (THG), and two-photon excited fluorescence (TPEF)) based on a picosecond (ps) laser-pumped optical parametric oscillator system for label-free imaging of the tooth. We demonstrate that high contrast ps-CARS images covering both the fingerprint (500–1800 cm{sup −1}) and high-wavenumber (2500–3800 cm{sup −1}) regions can be acquired to uncover the distributions of mineral and organic biomaterials in the tooth, while high quality TPEF, SHG, and THG images of the tooth can also be acquired under ps laser excitation without damaging the samples. The quadruple-modal nonlinear microscopic images (CARS/SHG/THG/TPEF) acquired provide better understanding of morphological structures and biochemical/biomolecular distributions in the dentin, enamel, and the dentin-enamel junction of the tooth without labeling, facilitating optical diagnosis and characterization of the tooth in dentistry.

60 APPLIED LIFE SCIENCES↗

Fine structure of modal focusing effect in a three dimensional plasma-sheath-lens formed by disk electrodes

Modal and discrete focusing effects associated with three-dimensional plasma-sheath-lenses show promising potential for applications in ion beam extraction, mass spectrometry, plasma diagnostics and for basic studies of plasma sheath. The ion focusing properties can be adjusted by controlling the geometrical structure of the plasma-sheath-lens and plasma parameters. The positive and negative ion kinetics within the plasma-sheath-lens are investigated both experimentally and theoretically and a modal focusing ring is identified on the surface of disk electrodes. The focusing ring is very sensitive to the sheath thickness and can be used to monitor very small changes in plasma parameters. Three dimensional simulations are found to be in very good agreement with experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗